The organic matter of the surface horizons of soils developed below scrub vegetation in a Mediterranean semi-arid area of great environmental interest (Cabo de Gata-Níjar Natural Park, SE Spain) has been studied. The study mainly concentrates on examining the influence of two vegetation types, one evolved (according to its successional stage), and the other clearly degraded as a result of prior removal of vegetation. In spite of the homogeneity in the results obtained from the analysis of the organic matter from the soils studied, a relationship may be established between vegetation biotype and characteristics and evolution of the soil organic matter. The evolved vegetation results in the presence in the soil of a somewhat more evolved and stable organic matter (demonstrated by certain chemical and microbiological aspects), resulting in a greater degree of humification, thus favouring the protection of the soil and the ecosystem as a whole. Hence, the presence of degraded vegetation might lead to soil degradation, something that is unsustainable in semi-arid areas that are particularly fragile in nature. 相似文献
The study area is located in the south-eastern part of the Crati valley (Northern Calabria, Italy), which is a graben bordered by N–S trending normal faults and crossed by NW–SE normal left-lateral faults. Numerous severe crustal earthquakes have affected the area in historical time. Present-day seismic activity is mainly related to the N–S faults located along the eastern border of the graben. In this area, much seismically induced deep-seated deformation has also been recognised.In the present paper, radon concentrations in soil gas have been measured and compared with (a) lithology, (b) Quaternary faults, (c) historical and instrumental seismicity, and (d) deep-seated deformation.The results highlight the following:
(a) There is no evidence of a strong correlation between lithology and the radon anomalies.
(b) A clear correlation between the N–S geometry of radon anomalies and the orientation of main fault systems has been recognised, except in the southernmost part of the area, where the radon concentrations are strongly affected by the superposition of the N–S and the NW–SE fault systems.
(c) Epicentral zones of instrumental and historical earthquakes correspond to the highest values of radon concentrations, probably indicating recent activated fault segments. In particular, high radon values occur in the zones struck by earthquakes in 1835, 1854, and 1870.
(d) Deep-seated gravitational deformation generally coincides with zones characterised by low radon concentrations.
In the studied area, the anisotropic distribution of radon concentrations is congruent with the presence of neotectonic features and deep-seated gravitational phenomena. The method used in this study could profitably contribute towards either seismic risk or deep-seated gravitational deformation analyses. 相似文献
Flood stories in the Hebrew Bible and the Koran appear to be derived from earlier flood stories like those in the Gilgamesh Epic and still earlier in the Atrahasis. All would have their source from floods of the Tigris and Euphrates rivers.
The Gilgamesh Epic magnifies the catastrophe by having the flood begin with winds, lightning, and a shattering of the earth, or earthquake. Elsewhere in Gilgamesh, an earthquake can be shown to have produced pits and chasms along with gushing of water. It is commonly observed that earthquake shaking causes water to gush from the ground and leaves pits and open fissures. The process is known as soil liquefaction. Earthquake is also a possible explanation for the verse “all the fountains of the great deep (were) broken up” that began the Flood in Genesis. Traditionally, the “great deep” was the ocean bottom. A more recent translation substitutes “burst” for “broken up” in describing the fountains, suggesting that they erupted at the ground surface and were caused by an earthquake with soil liquefaction. Another relation between soil liquefaction and the Flood is found in the Koran where the Flood starts when “water gushed forth from the oven”. Soil liquefaction observed erupting preferentially into houses during an earthquake provides a logical interpretation if the oven is seen as a tiny house. A case can be made that earthquakes with soil liquefaction are embedded in all of these flood stories. 相似文献
Numerous studies have been conducted with electrochemical removal of heavy metals from spiked kaolinite. Meanwhile, when moving from kaolinite to real soils, new factors must be taken into account—factors influencing, e.g., the buffering capacity of the soil against acidification and the adsorption/desorption processes of the heavy metals. The present study gives some examples where it is necessary to use an enhancement solution to aid desorption of Cu, Zn and Pb during electrodialytic treatment. Dependent on the composition of the pollution, different choices can be made. In the case of a Cu-polluted calcareous soil, ammonia may be used as enhancement solution, due to the formation of charged complexes between ammonia and Cu. Thus, Cu is mobile at high pH when ammonia is added and Cu can be removed without dissolving the calcareous parts. Zn is also mobilized by ammonia, but to a lesser extent than Cu. In the case of Cu, Zn and Pb at the same time, alkaline ammonium citrate may be a solution. It was shown that this enhancement solution could mobilize these three pollutants, but optimization of concentration and pH of the ammonium citrate is still needed. When choosing a remediation scheme for electrochemical treatment of an actual industrially polluted soil, this scheme must be chosen on basis of characterization of soil and pollution combination. 相似文献
A mountainous terrain, the eastern Pontide tectonic belt, located in northeastern Turkey, contains more than 60 known volcanogenic massive sulfide (VMS) deposits that differ in reserves (0.1–30 million tonnes) and grades. Soil geochemistry is conventionally used in exploration programs to discover concealed VMS deposits in the region. In the present study, Pb and As element pair were used as pathfinder elements to investigate the relationship of their anomalies to a completely delineated ore deposit (Killik VMS deposit) in an orientation survey that served as a natural physical model. Two hundred forty soil samples were analyzed in the present study. The two elements, which represent the opposite ends of the mobility range, revealed high contrast and overlapped each other at the location of the ore deposit due to enhancement of the anomalies by hydromorphic dispersion, which is an indication that soil samples would produce reliable results. The successful delineation of the deposit is remarkable considering the rough topography and the climatic limitations. Previously the extremely moist and temperate climate was thought to cause excessive leaching of the trace element pathfinders from the ore deposits to produce extensive anomalies usually extending away from the mineralization thus, leading to erroneous results and/or extensive anomalous areas. But the present research has shown that the method can be used effectively if the sampling and data evaluation is carefully conducted. 相似文献
A multi-layered aquifer, typical of riverbank alluvial deposits in Korea, was studied to determine the hydrologic properties.
The geologic logging showed that the subsurface of the study site was comprised of four distinctive hydrogeologic units: silt,
sand, highly weathered and fresh bedrock layers. The electrical resistivity survey supplied information on lateral extension
of hydrogeologic strata only partially identified by a limited number of the geologic loggings. The laboratory column tracer
test for the recovered core of the sand layer resulted in a hydraulic conductivity of 5.00×10−2 cm/s. The slug tests performed in the weathered rock layer yielded hydraulic conductivities of 4.32–7.72×10−4 cm/s. Hydraulic conductivities for the sand layer calculated from the breakthrough curves of bromide ranged between 2.08×10−3 and 2.44×10−2 cm/s with a geometric mean of 6.89×10−3 cm/s, which is 7 times smaller than that from the laboratory column experiment. The trend of increasing hydraulic conductivity
with an increase in tracer travel length is likely a result of the increased likelihood of encountering a high conductivity
zone as more of the aquifer is tested. The combined hydrogeologic site characterization using hydraulic tests, tracer tests,
and column test with geologic loggings and geophysical survey greatly enhanced the understanding of the hydrologic properties
of the multi-layered alluvial aquifer. 相似文献
The factors of safety for stationkeeping systems in current standards (ISO, API) are not derived or validated using reliability analyses. As the oil and gas exploration and production is breaking new boundaries, deploying new floating systems and moving into regions with harsher environments, it is of paramount importance to understand what level of reliability these new marine structures are achieving. This paper presents a reliability analysis of the mooring system of a Floating LNG (FLNG) vessel permanently moored and permanently manned offshore North West Australia in a tropical cyclone environment. The reliability analysis addresses both the mooring chain and the pile foundation. The analysis accounts for the long term characteristics of the environment, including the short term variability, in response to a given sea state and the variability and uncertainty in strength of the mooring chain and the pile. The stationkeeping system was analysed using detailed time domain simulations, capturing system non-linearities and low frequency oscillations as well as wave frequency responses and, thereby, reducing modelling uncertainties to a minimum.It is found that for the conditions modelled, neither the chain nor the pile meet a target reliability of 10−4/annum using the factors of safety commonly used in design following current ISO and API standards. New factors of safety are proposed to achieve this target reliability. For the pile design, one complicating factor is that current design standards do not explicitly define the exceedance probability that should be associated with the characteristic value of the undrained shear strength to be used in the design. It is demonstrated that the required factor of safety is crucially dependent on the definition of this characteristic value and on the level and the type of uncertainty in the soil strength profile. A recommendation is made regarding the definition of this characteristic value and the associated factor of safety. Furthermore, it is found that designing the mooring system to an environmental condition with a return period of 10,000 yr (as an Abnormal Limit State event), and setting the factor of safety to unity, meets the target reliability of 10−4/annum for the pile, if the characteristic undrained shear strength is a lower bound, defined in this paper by the 10th percentile value. For the chain however, this target reliability is not achieved. 相似文献