首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   15篇
  免费   1篇
  国内免费   10篇
地球物理   2篇
地质学   21篇
海洋学   2篇
综合类   1篇
  2021年   1篇
  2019年   1篇
  2017年   1篇
  2016年   1篇
  2014年   2篇
  2013年   1篇
  2011年   2篇
  2010年   1篇
  2007年   3篇
  2006年   2篇
  2005年   2篇
  2003年   1篇
  2000年   2篇
  1999年   2篇
  1998年   1篇
  1997年   1篇
  1993年   1篇
  1986年   1篇
排序方式: 共有26条查询结果,搜索用时 15 毫秒
1.
A series of hand-picked vitrinite samples from the Lower Kittanning Seam, Pennsylvania have been examined using quantitative pyrolysis-gas chromatography. These vitrinites ranged in rank from 0.59 to 1.71% reflectance, a rank range from high volatile C bituminous to low volatile bituminous. High molecular weight pyrolysis products included alkyl aromatic and phenolic compounds. Attempts have been made to correlate the pyrolysis product composition to rank parameters including vitrinite reflectance, volatile matter yield, carbon content, atomic H/C ratio and Rock-Eval determined Tmax. Total yield of phenols was found to be strongly and inversely rank related. A clear relationship between C8 alkyl-benzene yield and rank was not found for the sample set.  相似文献   
2.
沉积物14 C的年龄测定一直是第四纪年代学研究的热点。文章对中国干旱、半干旱地区的内蒙古库伦泥炭剖面的泥炭全样、植物残体和孢粉浓缩物进行了AMS 14 C测年比较研究。从泥炭沉积物中提取用于AMS 14 C测年的孢粉浓缩物的关键步骤包括:过筛(125μm,63μm和10μm),重液浮选(比重1.9)及在180倍的体视显微镜下进行手工挑选。测年结果表明:孢粉浓缩物的测年值比同一层位的泥炭沉积物全样或植物残体的测年值老225~340年; 植物残体与孢粉浓缩物的测年结果较为接近。但是,距地表24~27cm处孢粉浓缩物给出了610~780A.D.的年龄值,远老于其下样点的年龄,而泥炭全样为现代样品,二者相差1255年,这可能与该样品孢粉纯度较低、掺杂有一些老碳物质燃烧后形成的微粒杂质有关。因此,提高孢粉纯度对孢粉浓缩物14 C测年至关重要。  相似文献   
3.
采用《测量不确定度评定与表示指南》,以火焰原子吸收光谱法测定铜精矿中的银含量为例,对测量结果进行不确定度评定。分析了不确定度的重要来源,包括称样质量、标准工作溶液、工作曲线拟合、试液定容体积及测量重复性等引入的不确定度分量组成。对各不确定度分量进行分析计算,求得标准不确定度为1.56,扩展不确定度为3.12。  相似文献   
4.
燕娜  赵生国  赵伟  郑红文 《岩矿测试》2014,33(2):197-202
准确快速测定铜精矿中7种稀有金属元素(镓铟锗硒碲铊镧)的分布情况对于铜精矿的综合利用及减少技术性贸易壁垒等方面具有重要意义,因锗和铊等目标元素含量低至10-7级,要求分析方法具有高灵敏度。本文应用微波消解-电感耦合等离子体质谱方法实现了7种稀有金属元素的快速准确测定。以盐酸-硝酸混合酸(体积比3:2)作为样品的微波消解试剂,选取合适的分析质量、调谐仪器及数学校正方程等三种方式消除质谱干扰。在优化的实验条件下,目标元素加标回收率为80.2%~123.3%,相对标准偏差小于13.4%。硒的检出限为1.3 mg/kg,另外6种目标元素的检出限均低于0.08 mg/kg。本法目标元素的检出限均低于电感耦合等离子体发射光谱或原子吸收光谱法测定相应元素的检出限。该方法降低了试剂空白,简化了操作流程,提高了分析灵敏度,实现了铜精矿目标元素的同时分析。  相似文献   
5.
17 samples were collected from aeolian and lacustrine profiles within the environment sensitive zone of the Loess Plateau, and an experimental method was established which is suitable for pollen extraction from aeolian sediment. A comparative study of pollen dating was carried out using the accelerator mass spectrometry (AMS)14C dating of known age samples, and then an experiment with the pollen concentrates was performed. The results indicate that pollen that has been deposited simultaneously with sediment in a stable environment can provide reliable ages. This technique will provide a way of improving the chronological framework for the Loess Plateau since the late Pleistocene. TheI4c dating was combined with field investigations, and from the geological record within this zone, evidence was extracted of four major monsoon precipitation changes during the transition from the late Pleistocene to Holocene. Project supported by the National Natural Science Foundation of China (Grant Nos. 49894170, 49725308), Chinese Academy of Sciences (Nos. KZ-951-A1-402& KZ-952-S1-419), and State Committee of Science and Technology of China.  相似文献   
6.
锌精矿氧压酸浸液中铟的提取研究   总被引:2,自引:0,他引:2  
对锌精矿氧压酸浸液中铟的提取进行了研究,在1.0m o l/L的H2SO4介质中,铟可被P204定量萃取,当萃取相比为O/A=1/4,进行三级萃取,平衡时间为3m in时,In萃取率达97%以上;对负载有机相用3m o l/L的HC l进行三级反萃,O/A=5/1,平衡时间为3m in,In反萃率为99.62%。  相似文献   
7.
冷原子吸收法测定铜,铅和锌的精矿中的汞   总被引:3,自引:0,他引:3  
孙龄高  陈凯 《岩矿测试》1997,16(2):153-154158
试验了用冷原子吸收法测定铜精矿、铅精矿和锌精矿中微量Hg的适宜条件,拟定出适于3种精矿中3 ̄500μg/gHg的测定方法。方法的RSD(n=11)〈10%,回收率为90% ̄102%,与双硫腙光度法测定结果吻合。  相似文献   
8.
我国铜工业发展面临的问题与对策   总被引:6,自引:1,他引:6       下载免费PDF全文
目前,我国精铜消费水平飞速提升,国内产量快速增长,进口贸易空前壮大。企业竞争能力在增强,但同时铜工业也面临许多问题。需要制订一些行业对策,加快铜矿业的发展,认真在国际市场建立长期稳定的原料供应渠道,充分发挥我国巨大铜消费市场优势,企业联合统一进口原料,减少价损。加快铜工业结构调整,使之能持续、稳定、健康发展。  相似文献   
9.
华明 《岩矿测试》2013,32(2):235-239
在高氯酸-硫脲介质中用原子吸收光谱法同时测定地质及选冶样品中银和铜已有文献报道;但在王水-硫脲介质中存在铜对银的测定干扰.本文采用盐酸-氢氟酸-硝酸-高氯酸四酸溶矿,王水提取、硫脲络合,用火焰原子吸收光谱法对银精矿中铜、银进行连续测定.通过筛选不同的样品消解方法,试验了硫脲介质浓度的影响,对共存元素的干扰进行消除.结果表明:四酸溶矿效果最好;通过加入过量的硫脲并控制其浓度在20 g/L以内,使溶液中银的白色沉淀与硫脲生成可溶的Ag[SC(NH2)2]3+配离子,消除了铜对银测定的干扰.该方法用于样品分析,相对标准偏差RSD(n =6)铜为1.20%~2.11%,银为0.61% ~1.18%;加标回收率铜为96.5% ~ 107.0%,银为97.3% ~ 104.7%.测定值与碘量法、火试金法结果相符.本法具有简单、实用、成本低等优点,可满足银精矿选矿工艺生产的需要.  相似文献   
10.
船舶稳性事故的后果非常严重。造成稳性减小的原因很复杂,归纳起来有积载不当,产生自倾角或大风浪中引起货物移位;精矿粉含水量过高等。为了防止船舶因稳性问题而发生海损事故,最根本最有效的措施是,加强工作责任心,作好配积载计划,严格把关,密切配合等。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号