首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
基于MODIS的安徽省代表城市热岛效应时空特征   总被引:2,自引:0,他引:2       下载免费PDF全文
利用2001—2010年覆盖安徽省的MODIS数据,选取在气候、地理、城市化等方面具有代表性的合肥、芜湖、阜阳作为研究对象,并结合GIS技术,分析地表温度的日变化及季节变化特征,得到安徽省代表城市热岛效应的时空分布。结果表明:安徽省省会合肥的热岛效应最为显著,安徽省南部代表城市芜湖的热岛效应强于北部代表城市阜阳, 同时具有显著的日变化和季节变化特征。近10年来,安徽代表城市热岛面积和热岛强度均呈增加趋势,但合肥热岛强度大于3 ℃的极端热岛效应有一定缓解。白天大片水体对缓解城市的热岛效应作用明显,而夜晚则不明显,甚至成为地表温度的高值中心。夏季地表温度与归一化植被指数的负相关最显著,即提高城市植被覆盖度对降低地表温度和缓解城市热岛效应有重要影响。  相似文献   

2.
In this study, the urban heat island of Toronto was characterized and estimated in order to examine the impact of the selection of rural sites on the estimation of urban heat island (UHI) intensity (?T u-r). Three rural stations, King Smoke Tree (KST), Albion Hill, and Millgrove, were used for the analysis of UHI intensity for two urban stations, Toronto downtown (Toronto) and Toronto Pearson (Pearson) using data from 1970 to 2000. The UHI intensity was characterized as winter dominating and summer dominating, depending on the choice of the rural station. The analyses of annual and seasonal trends of ?T u-r suggested that urban heat island clearly appears in winter at both Toronto and Pearson. However, due to the mitigating effect on temperature from Lake Ontario, the estimated trend of UHI intensity was found to be less at Toronto compared to that at Pearson which has no direct lake effect. In terms of the impacts of the rural stations, for both KST and Millgrove, the trends in UHI intensity were found to be statistically significant and also were in good agreement with the estimates of UHI intensities reported for other large cities in the USA. Depending on the choice of the rural station, the estimated trend for the UHI intensity at Toronto ranges from 0.01°C/decade to 0.02°C/decade, and that at Pearson ranges from 0.03°C/decade to 0.035°C/decade during 1970–2000. From the analysis of the seasonal distribution of ?T u-r, the UHI intensity was found to be higher at Toronto in winter than that at Pearson for all three rural stations. This was likely accounted for by the lower amount of anthropogenic heat flux at Pearson. Considering the results from the statistical analysis with respect to the geographic and surface features for each rural station, KST was suggested to be a better choice to estimate UHI intensity at Toronto compared to the other rural stations. The analysis from the current study suggests that the selection of a unique urban–rural pair to estimate UHI intensity for a city like Toronto is a critical task, as it will be for any city, and it is imperative to consider some key features such as the physiography, surface characteristics of the urban and rural stations, the climatology such as the trends in annual and seasonal variation of UHI with respect to the physical characteristics of the stations, and also more importantly the objectives of a particular study in the context of UHI effect.  相似文献   

3.
The Advanced Regional Prediction System (ARPS) is coupled with the tropical town energy budget (tTEB) scheme to analyze the effects of the urban canopy circulation over the metropolitan area of São Paulo and its interactions with the sea breeze and mountain-valley circulation in the eastern state of São Paulo, Brazil. Two experiments are carried out for the typical sea-breeze event occurring on 22 August 2014 under weak synoptic forcing and clear-sky conditions: (a) a control run with the default semi-desert surface parametrization and; (b) a tTEB run for the urban canopy of São Paulo. A realistic land-use database over the south-eastern domain of Brazil is used in the downscaling simulation to a horizontal grid resolution of 3 km. Our results indicate that ARPS effectively simulates features of the nighttime and early morning land-breeze circulation, which is affected by the surrounding hills and the nocturnal heat island of São Paulo. By early afternoon, the south-eastern sea-breeze circulation moves inland perpendicular to the upslope of the Serra do Mar scarp, which generates a line of moisture convergence and updrafts further inland. Later, the convergence line reaches São Paulo and interacts with the circulation arising from the urban heat island (UHI), which increases the moisture convergence and strength of updrafts. The surface energy balance indicates that the UHI is caused by large sensible heat storage within the urban canopy during the day, which is later released in the afternoon and at night. The simulations are verified with available radiosonde and surface weather station data, land-surface-temperature estimates from the moderate resolution imaging spectroradiometer, as well as the National Center for Atmospheric Research reanalysis databases. The three-dimensional geometry of the urban canyons within the tTEB scheme consistently improves the thermodynamically-induced circulation over São Paulo.  相似文献   

4.
This paper aims to map the thermal field in the metropolitan region of Rio de Janeiro (MARJ) considering the atmospheric characteristics and the land use that contribute to understanding the urban heat island. Three thermal maps are defined through the use of Landsat5-TM satellite images for three winter events chosen for the decades of 1980, 1990, and 2000, respectively. The results reveal a concentration of warmer cores in urban central areas as well as some local warmer areas in suburban region. Sites with lower temperatures correspond to vegetated areas which are away from the central part of the MARJ, including points of suburban areas. This work emphasizes the importance of the combined analysis of surface temperature with land use and atmospheric conditions, depicting a distinct pattern of heat islands for tropical climate.  相似文献   

5.
In this study, urban climate in Nanjing of eastern China is simulated using 1-km resolution Weather Research and Forecasting (WRF) model coupled with a single-layer Urban Canopy Model. Based on the 10-summer simulation results from 2000 to 2009 we find that the WRF model is capable of capturing the high-resolution features of urban climate over Nanjing area. Although WRF underestimates the total precipitation amount, the model performs well in simulating the surface air temperature, relative humidity, and precipitation frequency and inter-annual variability. We find that extremely hot events occur most frequently in urban area, with daily maximum (minimum) temperature exceeding 36°C (28°C) in around 40% (32%) of days. Urban Heat Island (UHI) effect at surface is more evident during nighttime than daytime, with 20% of cases the UHI intensity above 2.5°C at night. However, The UHI affects the vertical structure of Planet Boundary Layer (PBL) more deeply during daytime than nighttime. Net gain for latent heat and net radiation is larger over urban than rural surface during daytime. Correspondingly, net loss of sensible heat and ground heat are larger over urban surface resulting from warmer urban skin. Because of different diurnal characteristics of urban-rural differences in the latent heat, ground heat and other energy fluxes, the near surface UHI intensity exhibits a very complex diurnal feature. UHI effect is stronger in days with less cloud or lower wind speed. Model results reveal a larger precipitation frequency over urban area, mainly contributed by the light rain events (< 10 mm d?1). Consistent with satellite dataset, around 10?C20% more precipitation occurs in urban than rural area at afternoon induced by more unstable urban PBL, which induces a strong vertical atmospheric mixing and upward moisture transport. A significant enhancement of precipitation is found in the downwind region of urban in our simulations in the afternoon.  相似文献   

6.
北京"城市热岛"效应现状及特征   总被引:37,自引:16,他引:21  
利用2002年北京自动气象站资料,对北京“城市热岛”效应现状进行了分析。为了与20世纪70年代的结果相比较,选择城区代表站为天安门广场站,城郊代表站为朝阳气象站站。与20世纪70年代相比,目前北京的“城市热岛”表现出一些新特点:1)利用城区与城郊日均温差表示的“城市热岛”强度的统计结果表明,现在北京的“城市热岛”效应在夏季最强,秋、冬季次之,春季最弱,2)除夏季“城市热岛”整天存在(午后的平均强度在2℃左右)以外,其他季节的午后,天安门广场地区经常出现“城市冷岛”现象。3)北京“城市热岛”消失的极限风速没有发生系统性变化,当风速>3级时,北京“城市热岛”基本上消失。作者还研究了北京“城市热岛”形成和消失的日变化特征,以及“城市热岛”强度对风速等气象要素变化的响应特征。值得指出的是,对强“城市热岛”的个案分析显示,冬季夜晚“城市热岛”强度经常表现出较大的波动性,与此相伴随,城郊地面风出现风向突变和风速的阵性现象。  相似文献   

7.
Li  Mengmeng  Wang  Tijian  Xie  Min  Zhuang  Bingliang  Li  Shu  Han  Yong  Cheng  Nianliang 《Theoretical and Applied Climatology》2017,128(3-4):999-1013

Through regulating the land–atmosphere energy balance, urbanization plays an important role in modifying local circulations and cross-border transport of air pollutants. The Beijing–Tianjin–Hebei (BTH) metropolitan area in northern China is frequently influenced by complex atmospheric thermal circulations due to its special topography and geographic position. In this study, the Weather Research and Forecasting (WRF) model combined with remote sensing is used to explore the urbanization impacts on local circulations in the BTH region. The urban heat island (UHI) effect generated around Beijing and Tianjin shows complex interactions with local thermal circulations. Due to the combined effects of UHI and topography, the UHI circulation around Beijing and valley breeze at the southern slopes of Yan Mountain are coupled together to reinforce each other. At the coastal cities, the increased land/sea temperature gradient considerably accelerates the sea breeze along Bohai Bay and moves the sea breeze front further inland to reach as far as Beijing. This study may lay a foundation for the better understanding of air pollutant dispersion on complex terrain.

  相似文献   

8.
The study underlines the characteristics of the urban heat island of Ia?i (Ia?i’s UHI) on the basis of 3 years of air temperature measurements obtained by fixed-point observations. We focus on the identification of UHI development and intensity as it is expressed by the temperature differences between the city centre and the rural surroundings. Annual, seasonal and daily characteristics of Ia?i’s UHI are investigated at the level of the classical weather observation. In brief, an intensity of 0.8 °C of UHI and a spatial extension which corresponds to the densely built area of the city were delineated. The Ia?i UHI is stronger during summer calm nights—when the inner city is warmer with 2.5–3 °C than the surroundings—and is weaker during windy spring days. The specific features of Ia?i’s UHI bear a profound connection to the specificity of the urban structure, the high atmospheric stability in the region and the local topography. Also, the effects of Ia?i’s UHI upon some environmental aspects are presented as study cases. For instance, under the direct influence of UHI, we have observed that in the city centre, the apricot tree blossoms earlier (with up to 4 days) and the depth of the snow cover is significantly lower (with up to 10 cm for a rural snow depth of 30 cm) than in the surrounding areas.  相似文献   

9.
Air temperature was monitored at 13 sites across the urban perimeter of a Brazilian midsize city in winter 2011. In this study, we show that the urban heat island (UHI) develops only at night and under certain weather conditions, and its intensity depends not only on the site's land cover but also on the meteorological setting. The urban heat island intensity was largest (6.6 °C) under lingering high-pressure conditions, milder (3.0 °C) under cold anticyclones and almost vanished (1.0 °C) during the passage of cold fronts. The cooling rates were calculated to monitor the growth and decay of the UHI over each specific synoptic setting. Over four contiguous days under the effect of a lingering high-pressure event, we observed that the onset of cooling was always at about 2 h before sunset. The reference site attained mean cooling rate of ?2.6 °C h?1 at sunset, whilst the maximum urban rate was ?1.2 °C h?1. Under a 3-day cold anticyclone episode, cooling also started about 2 h before sunset, and the difference between maximum rural (?2.0 °C h?1) and urban (?1.0 °C h?1) cooling rates diminished. Under cold-front conditions, the cooling rate was homogeneous for all sites and swang about zero throughout the day. The air temperature has a memory effect under lingering high-pressure conditions which intensified the UHI, in addition to the larger heat storage in the urban area. Cold anticyclone conditions promoted the development of the UHI; however, the cold air pool and relatively light winds smoothed out its intensity. Under the influence of cold fronts, the urban fabric had little effect on the city's air temperature field, and the UHI was imperceptible.  相似文献   

10.
城市热岛效应的研究进展与展望   总被引:24,自引:1,他引:23  
寿亦萱  张大林 《气象学报》2012,70(3):338-353
随着世界各国城市化的进展,城市热岛效应已经成为一个跨学科领域的问题,受到包括大气环境、区域气候、水文和生态等多学科科学家的关注。在过去半个多世纪中,城市热岛问题的研究获得了相当丰富的研究成果,通过对这些成果的综合分析,归纳出城市热岛研究中采用的3类主要方法——观测(外场试验和遥感技术)、数值模拟以及实验室仿真法。系统地回顾了城市热岛效应的研究历史,重点对与城市热岛关系最密切的城市边界层、热岛环流与复杂地形的相互作用以及能量平衡研究所取得的成果进行了总结和评述。最后对城市热岛问题未来8个可能的研究方向进行了探讨,其中,包括沿海和复杂地形附近的城市热岛问题、城市群间热岛环流的相互作用、城市化与空气污染问题、城市热岛效应对平均降水的影响、城市化对雾和闪电的影响、城市天气预报的精细化、城市气候变化预测以及城市热岛效应减缓方案的制定,并对其发展前景进行了粗略的展望。  相似文献   

11.
The public health implications of a warming urban environment mean that appropriate action by planners, designers and health workers will be necessary to minimise risk under future climate scenarios. Data at an appropriate spatial scale are required by user groups in order to identify key areas of vulnerability. Thermal mapping of a UK urban conurbation was carried out during the summers of 2007 and 2008 with the aim of providing high spatial resolution temperature data. The air temperature results showed an average daytime (night time) urban?Crural thermal contrast of 3°C (5°C) on summer days (nights) with ideal urban heat island (UHI) conditions. The intensity of the daytime surface temperature heat island was found to exceed 10°C. The measured data were used to derive an empirical model of spatial temperature patterns based upon characteristics of land use, distance from urban centre and building geometry. This model can be used to provide sub-kilometre resolution temperature data which are required by decision makers and can provide a mechanism for downscaling climate model output.  相似文献   

12.
In this paper, several methods of incorporating anthropogenic heat release into the boundary layer are compared. The best scheme was one that included anthropogenic heat release in both the surface energy balance equation and the thermodynamic equations. In addition, it included diurnal variations and a distribution of heat based on building concentrations. We further investigated the influence of anthropogenic heat release on urban boundary layer structure and the urban heat island, and found that the contribution of anthropogenic heat release to the urban heat island is greatest in the evening and at night, and least at noon. The daily average contribution ratio of anthropogenic heat to urban heat island intensity in the winter is 54.5%, compared with just 43.6% in the summer. Anthropogenic heat strengthens the vertical movement of urban surface air flow, changing the urban heat island circulation. It also makes the urban boundary layer more turbulent and unstable, especially in the morning and evening. The degree of influence of anthropogenic heat release on local boundary layer structure depends on its importance to the surface energy budget.  相似文献   

13.
The Anatolian Peninsula is located at the confluence of Europe, Asia, and Africa and houses 81 cities of which 79 of them have population over 100,000. We employed some criteria to select the cities from the 81 cities. After accomplishing all the criteria, eight cities were remaining for the study. Nonparametric Mann–Kendall test procedure was employed for the urban and rural stations of these cities to detect the long-term change in temperature trends. Statistical analysis of daily minimum temperatures for the period between 1965 and 2006 suggest that there is no statistically significant increase in rural areas. In contrast to the findings of the previous studies, however, all the urban sites and difference between urban and rural pairs show significant increase in temperatures, a strong indication for the existence of urban heat island (UHI) affect over the region. Regional Climate Model was also utilized to assess the changes in temperature by the end of century for the region. The findings suggest that an increase of up to 5°C is possible. Climate change effects enforced with UHI have the potential to cause serious problems for the entire region and hence needs to be studied thoroughly.  相似文献   

14.
Summary This paper deals with variability in the air temperature field of an urban area during thermal advection, associated with frontal zones, and its interaction with an urban heat island (UHI). Thermal changes experienced in Wrocław, Poland form the basis of this case study analysis. The discussion also contributes to questions concerning the definition of the UHI and ways to select UHI episodes from existing data sets. It is shown that changes in temperature generated during periods of advection are of short duration, only a few hours at most, but thermal contrasts between various parts of a city at such times are sometimes large, reaching an intensity of 5–6 K, even as large as 9 K. Thus, their intensity is comparable with that of the UHI occurring on cloudless and windless nights. The thermal influence of advection is often greater than that due to urban factors; it is only on occasions with less dynamic advection, that a concentric temperature field is formed due to the modified physical properties of the city. In the majority of cases, the thermal field is non-concentric and this is linked with the location of a frontal zone at any given time. The thermal effects of advection recorded in a data set might easily be viewed as episodes of UHI existence, especially if analysis is conducted based on the data derived from just two stations – one urban the other rural. On occasions when such ‘quasi-UHI’ occur the role of the location of the rural, reference station is also evaluated. Precise definition of the urban heat island can be of significance when conducting comparative studies of the UHI in cities located in different geographical zones and when making an urban climate synthesis.  相似文献   

15.
High temperatures and heatwaves can cause large societal impacts by increasing health risks, mortality rates, and personal discomfort. These impacts are exacerbated in cities because of the Urban Heat Island (UHI) effect, and the high and increasing concentrations of people, assets and economic activities. Risks from high temperatures are now widely recognised but motivation and implementation of proportionate policy responses is inhibited by inadequate quantification of the benefits of adaptation options, and associated uncertainties. This study utilises high spatial resolution probabilistic projections of urban temperatures along with projections of demographic change, to provide a probabilistic risk assessment of heat impacts on urban society. The study focuses on Greater London and the surrounding region, assessing mortality risk, thermal discomfort in residential buildings, and adaptation options within an integrated framework. Climate change is projected to increase future heat-related mortality and residential discomfort. However, adjusting the temperature response function by 1–2 °C, to simulate adaptation and acclimatisation, reduced annual heat related mortality by 32–69 % across the scenarios tested, relative to a no adaptation scenario. Similar benefits of adaptation were seen for residential discomfort. The study also highlights additional benefits in terms of reduced mortality and residential discomfort that mitigating the urban heat island, by reducing albedo and anthropogenic heat emissions, could have.  相似文献   

16.
The study has analyzed influence of an atmospheric circulation on urban heat island (UHI) and urban cold island (UCI) in Poznań. Analysis was conducted on the basis of temperature data from two measurement points situated in the city center and in the ?awica airport (reference station) and the data concerning the air circulation (Nied?wied?’s calendar of circulation types and reanalysis of National Centers for Environmental Prediction (NCEP)/National Center for Atmospheric Research (NCAR)). The cases with UHI constitute about 85 % of all data, and UCI phenomena appear with a frequency of 14 % a year. The intensity of UHI phenomenon is higher in the anticyclonic circulation types. During the year in anticyclonic circulation, intensity of UHI is 1.2 °C on average while in cyclonic is only 0.8 °C. The occurring of UHI phenomena is possible throughout all seasons of the year in all hours of the day usually in anticyclonic circulation types. The cases with highest UHI intensity are related mostly to nighttime. The cases of UCI phenomena occurred almost ever on the daytime and the most frequently in colder part of the year together with cyclonic circulation. Study based on reanalysis data indicates that days with large intensity of UHI (above 4, 5, and 6 °C) are related to anticyclonic circulation. Anticyclonic circulation is also promoting the formation of the strongest UCI. Results based on both reanalysis and the atmospheric circulation data (Nied?wied?’s circulation type) confirm that cases with the strongest UHI and UCI during the same day occur in strong high-pressure system with the center situated above Poland or central Europe.  相似文献   

17.
苏州—无锡—常州城市带热岛效应个例研究   总被引:2,自引:1,他引:1       下载免费PDF全文
应用WRF(weather research and forecasting)及其耦合的多层城市冠层模式BEP(building energy parameterization),对2013年8月13日长江三角洲地区一次高温天气过程进行了模拟。此次过程盛行东南风,风向与苏州—无锡—常州城市带走向一致。模拟结果表明:苏州—无锡—常州城市带热岛效应明显,热岛强度向下游城市逐渐增加;在东南风作用下,三座城市的热岛连成一片,形成了一个更强大的热岛环流。夜晚,边界层逐渐趋于稳定,热岛环流减弱,有利于热岛温度向下游地区输送。热岛效应导致城市边界层高度明显上升。白天太湖产生强盛的湖风对其周边城市影响显著,来自太湖的冷气团导致无锡和常州边界层内热岛强度明显下降,抑制城市热岛向上发展,削弱了无锡与常州两城市热岛间的联系。白天太湖使得无锡和常州边界层高度明显下降。  相似文献   

18.
Urban heat island intensities (UHI) have been assessed based on in situ measurements and satellite-derived observations for the megacity Delhi during a selected period in March 2010. A network of micrometeorological observational stations was set up across the city. Site selection for stations was based on dominant land use–land cover (LULC) classification. Observed UHI intensities could be classified into high, medium and low categories which overall correlated well with the LULC categories viz. dense built-up, medium dense built-up and green/open areas, respectively. Dense urban areas and highly commercial areas were observed to have highest UHI with maximum hourly magnitude peaking up to 10.7 °C and average daily maximum UHI reaching 8.3 °C. UHI obtained in the study was also compared with satellite-derived land surface temperatures (LST). UHI based on in situ ambient temperatures and satellite-derived land surface temperatures show reasonable comparison during nighttime in terms of UHI magnitude and hotspots. However, the relation was found to be poor during daytime. Further, MODIS-derived LSTs showed overestimation during daytime and underestimation during nighttime when compared with in situ skin temperature measurements. Impact of LULC was also reflected in the difference between ambient temperature and skin temperature at the observation stations as built-up canopies reported largest gradient between air and skin temperature. Also, a comparison of intra-city spatial temperature variations based UHI vis-à-vis a reference rural site temperature-based UHI indicated that UHI can be computed with respect to the station measuring lowest temperature within the urban area in the absence of a reference station in the rural area close to the study area. Comparison with maximum and average UHI of other cities of the world revealed that UHI in Delhi is comparable to other major cities of the world such as London, Tokyo and Beijing and calls for mitigation action plans.  相似文献   

19.
利用MODIS地表温度数据,计算城市热岛强度指数,分析近15年广州市城市热岛的时空分布特征及演变规律,并结合气象观测数据、社会统计数据定性分析其主要影响因素。结果表明:广州市城市热岛的空间分布受地形地貌影响明显,负热岛区主要分布于森林密集的北部山区,无热岛区主要分布于中部低山丘陵区域,热岛区主要分布于高度城市化的中南部平原区。关于城市热岛的日变化规律,白天热岛区、负热岛区面积均小于夜间,但白天热岛区强度、负热岛区强度大于夜间。关于城市热岛的季节变化规律,冬季热岛区面积最大,热岛强度最小,夏季热岛区面积最小,热岛强度最大;冬季负热岛区面积最小,负热岛强度最小,夏季负热岛区面积最大,负热岛强度最大。对于城市热岛的年际变化规律,近15年来广州市的热岛区、负热岛区占全市总面积的百分比呈上升趋势,无热岛区所占百分比呈下降趋势,人为热排放在城市中心区域的持续增长,加上区内建筑物密度大、植被覆盖度低,导致了热岛区的增加,而北部山区至中部丘陵山区的植被的持续好转,加上地理特征限制了该区域的城市化发展,导致了负热岛区的增加。   相似文献   

20.
The July urban heat island of Bucharest as derived from modis images   总被引:2,自引:1,他引:1  
The urban heat island (UHI) of the city of Bucharest (Romania) is analyzed in terms of its extension, geometry, and magnitude using the surface thermal data provided by the moderate resolution imaging spectroradiometer (MODIS) sensors. An objective method is developed that allows to delineate the UHI. The study focuses on the months of July from the 2000–2006 time interval. The average surface temperatures obtained for each pixel (1 km resolution) were analyzed on cross-profiles that helped us to determine the outline of the UHI. The shifting points identified by the Rodionov test in the temperature series of each profile were considered as possible limits of the UHI. Seemingly, the land cover has a major influence on the extension and the geometry of the Bucharest UHI in July. The magnitude of the heat island was calculated by comparing the average temperature inside its limits and the average temperature of the 5 km (a) and of the 10 km (b) buffers around it. The thermal difference between the UHI and the surrounding area of Bucharest is higher and more variable during the daytime, and is noticeably related to the land cover.  相似文献   