首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 562 毫秒
1.
A series of numerical experiments on the performance of different base isolation systems for a non-uniform shear beam structure is carried out. Several base isolation systems are considered and the peak relative displacements and the maximum absolute accelerations of the base-isolated structure and its base raft under a variety of conditions are evaluated. Several sensitivity analyses for variations in properties of the base isolator and the structure are carried out. A number of different earthquake excitations are also used in the study. The results show that performances of the base isolation systems are not sensitive to small variations in their natural period, damping or friction coefficient. The presence of a frictional element in the isolators reduces their sensitivity to severe variations in frequency content and amplitude of the ground acceleration. In particular, the resilient-friction base isolators with or without sliding upper plate perform reasonably well under a variety of loading conditions. The rubber bearing type, however, leads to the lowest peak transmitted accelerations for moderate intensity earthquakes.  相似文献   

2.
Hysteretic models for sliding bearings with varying frictional force   总被引:2,自引:1,他引:1  
The friction pendulum system is a sliding seismic isolator with self‐centering capabilities. Under severe earthquakes, the movement may be excessive enough to cause the pendulum to hit the side rim of the isolator, which is provided to restrain the sliding. The biaxial behavior of a single friction pendulum, in which the slider contacts the restrainer, is developed using a smooth hysteretic model with nonlinear kinematic hardening. This model is extended to simulate the biaxial response of double and triple friction pendulums with multiple sliding surfaces. The model of a triple friction pendulum is based on the interaction between four sliding interfaces, which in turn is dependent upon the force and displacement conditions prevailing at these interfaces. Each of these surfaces are modeled as nonlinear biaxial springs suitable for a single friction pendulum, using the yield surface, based on the principles of the classical theory of plasticity, and amended for varying frictional yield force, due to variation in vertical load and/or velocity‐dependent friction coefficient. The participation of the nonlinear springs is governed by stick‐slip conditions, dictated by equilibrium and kinematics. The model can simulate the overall force‐deformation behavior, track the displacements in individual sliding surfaces, and account for the ultimate condition when the sliders are in contact with their restrainers. The results of this model are verified by comparison to theoretical calculations and to experiments. The model has been implemented in programs IDARC2D and 3D‐BASIS, and the analytical results are compared with shake table experimental results. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
本文在已有摩擦阻尼器的基础上,设计可应用于装配式剪力墙竖向接缝的阻尼器。通过改变摩擦材料、高强螺栓预紧力等参数,对阻尼器工作性能参数(起滑力、起滑位移、等效初始刚度等)进行对比分析。研究结果表明,当摩擦材料为黄铜板、铝板及碳纤维板时,2个受力方向的起滑力相差不大,而当摩擦材料为橡胶板时,由于橡胶自身强度较低,2个受力方向的起滑力差异较大,工作性能相对较差;4种材料起滑位移及等效初始刚度在不同预紧力下按照一定规律变化,表现出较好的工作性能。在实际应用中,应设置碟形垫片以保证预紧力的稳定,使阻尼器工作性能良好。  相似文献   

4.
This paper studies the stochastic responses of secondary systems in base-isolated shear beam structures. A number of base isolation systems such as the laminated rubber bearing (LRB), the resilient-friction base isolator (R-FBI) with or without sliding upper plate, and the EDF system are considered. The stochastic models for the El Centro 1940 and the Mexico City 1985 earthquakes which preserve the non-stationary evolutions of amplitude and frequency content of ground accelerations are used as earthquake excitations. The technique of equivalent linearization is utilized and the mean-square response statistics of secondary systems and primary structure are evaluated. The accuracy of the linearization scheme is verified by comparison with the Monte Carlo simulation results. Statistically estimated peak responses of the secondary system are evaluated and the results are compared with the response spectra for actual earthquake accelerograms. It is shown that the use of base isolation systems, generally, provides considerable protection for structural contents. In particular, the LRB system is remarkably effective in reducing responses of secondary systems. Results for the Mexico City earthquake show that the base-isolated structures are sensitive to long period ground excitations.  相似文献   

5.
方形多铅芯橡胶支座力学性能研究   总被引:7,自引:0,他引:7  
本文通过对方形多铅芯橡胶支座竖向压缩性能试验,水平剪切性能试验以及其等效刚度、屈服强度、屈服后刚度、等效阻尼比等水平特征参数与水平剪切应变和竖向压应力的关系,特别是对其在不同方向上压缩剪切变形状态下的性能试验,分析了这种隔震支座各种水平特征参数在不同方向上变化的相关规律。得出在这种类型橡胶隔震支座在双向水平荷载同时作用下,竖向性能和水平性能较为稳定,是较为理想的桥梁结构的减隔震装置。  相似文献   

6.
The friction developed between a steel base plate and a mortar base contributes shear resistance to the building system during a seismic event. In order to investigate the possible sliding behavior between the base plate and the mortar, a shake table study is undertaken using a large rigid mass supported by steel contact elements which rest on mortar surfaces connected to the shake table. Horizontal input accelerations are considered at various magnitudes and frequencies. The results provide a constant friction coefficient during sliding with an average value of approximately 0.78. A theoretical formulation of the friction behavior is also undertaken. The theoretical equations show that the sliding behavior is dependent on the ratio of the friction force to the input force. The addition of vertical accelerations to the system further complicates the sliding behavior as a result of the varying normal force. This results in a variable friction resistance which is a function of the amplitude, phase, and frequency of the horizontal and vertical input motions. In general, this study showed a consistent and reliable sliding behavior between steel and mortar. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
The Friction Pendulum System (FPS) isolator is commonly used as a base isolation system in buildings. In this paper, a new tunable FPS (TFPS) isolator is proposed and developed to act as a semi‐active control system by combining the traditional FPS and semi‐active control concept. Theoretical analysis and physical tests were carried out to investigate the behavior of the proposed TFPS isolator. The experimental and theoretical results were in good agreement, both suggesting that the friction force of the TFPS isolator can be tuned to achieve seismic isolation of the structure. A series of numerical simulations of a base‐isolated structure equipped with the proposed TFPS isolator and subjected to earthquake ground motions were also conducted. In the analyses, the linear quadratic regulator (LQR) method was adopted to control the friction force of the proposed TFPS, and the applicability and effectiveness of the TFPS in controlling the structure's seismic responses were investigated. The simulation results showed that the TFPS can reduce the displacement of the isolation layer without significantly increasing the floor acceleration and inter‐story displacement of the superstructure, confirming that the TFPS can effectively control a base‐isolated structure under earthquake ground motions.  相似文献   

8.
Conventional steel-based rubber bearings are being replaced by fiber reinforced elastomeric isolators (FREI) due to their high weight and manufacturing cost. Compared to existing rubber bearings, FREIs have superior performance and as a result can control the seismic response of structures more efficiently. This study aims to simulate the performance of rectangular carbon FREIs (C-FREIs) produced through a simple and cost-effective manufacturing process. Additionally, the effect of different factors including the number and the thickness of rubber layers, as well as the thickness of carbon fiber reinforced sheets are investigated on the performance of C-FREIs through sensitivity analyses based on the results obtained from finite element simulations. The results show that by increasing the number and thickness of rubber layers, the efficiency of C-FREIs degrades in terms of vertical strength and damping capacity, however, the performance improves in terms of lateral flexibility. Another important observation is that the increasing thickness of fiber-reinforced layers can increase the vertical rigidity of the base isolator. The vertical stiffness has the most sensitivity to the thickness of elastomeric layers and the thickness of CFR sheets while, when the number of rubber layers increases, the effective lateral stiffness is mostly affected.  相似文献   

9.
采用有限元模拟的方式,对板式橡胶支座摩擦滑移特性进行分析,并与常温试验中获得的支座摩擦滑移滞回曲线、等效黏滞阻尼比等进行了对比。在获得可靠模型的基础上,分析环境温度对板式橡胶支座摩擦滑移特性的影响,研究了温度与支座摩擦滑移耗能、等效黏滞阻尼比和滑动起始距离的关系。结果表明:(1)板式橡胶支座的有限元模型可以较好地实现支座在水平荷载作用下的摩擦滑移特性;(2)在±25℃温度范围内,温度越低,板式橡胶支座在摩擦滑移过程中耗能越多,最大相差37.5%。在寒冷地区,支座将更早的进入滑移状态,对采用板式橡胶支座的桥梁更应注意控制桥梁上部结构的支承长度;(3)板式橡胶支座的黏滞阻尼比随着形状系数的减小而增大,而支座的起始滑移距离则随之减小。  相似文献   

10.
The effects of damping in various laminated rubber bearings (LRB) on the seismic response of a ?‐scale isolated test structure are investigated by shaking table tests and seismic response analyses. A series of shaking table tests of the structure were performed for a fixed base design and for a base isolation design. Two different types of LRB were used: natural rubber bearings (NRB) and lead rubber bearings (LLRB). Three different designs for the LLRB were tested; each design had a different diameter of lead plug, and thus, different damping values. Artificial time histories of peak ground acceleration 0.4g were used in both the tests and the analyses. In both shaking table tests and analyses, as expected, the acceleration responses of the seismically isolated test structure were considerably reduced. However, the shear displacement at the isolators was increased. To reduce the shear displacement in the isolators, the diameter of the lead plug in the LLRB had to be enlarged to increase isolator damping by more than 24%. This caused the isolator stiffness to increase, and resulted in amplifying the floor acceleration response spectra of the isolated test structure in the higher frequency ranges with a monotonic reduction of isolator shear displacement. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

11.
Curved surface sliding bearings, which are usually called as friction pendulum system (FPS) are commonly used for base isolation of liquid storage tanks since the period of the isolation system is independent of the storage level. However the restoring force and the damping at the isolation system are functions of axial load which changes during an earthquake excitation. This change might be in appreciable amounts especially for the tanks with high aspect ratios. The present paper focuses on earthquake performances of both broad and slender tanks base isolated by FPS bearings. The effects of overturning moment and vertical acceleration on axial load variation at the bearings are considered. The efficiency of the isolation system is investigated by analyzing the effects of various parameters such as; (i) isolation period, (ii) tank aspect ratio and (iii) coefficient of friction. The Haroun and Housner's three-degrees-of-freedom lumped mass model was used to solve the governing equations of motion in which convective, impulsive and rigid masses were included. A number of selected ground motions were considered and the results were compared to those of non-isolated cases.As a result, base isolation was found to be effective in reducing the base shear values for both broad and slender tanks without significantly affecting the sloshing displacements of the broad ones. The efficiency was even more pronounced for slender tanks subjected to near fault ground motions for isolation periods above 3 s. This specific value of isolation period also eliminated possible design problems arising from under-estimation of base shear values (up to 40%) due to ignoring the effects of axial load variation in lower isolation periods. Overturning effects should not be ignored especially for tanks with high aspect ratios (S) and being subjected to near fault ground motion.  相似文献   

12.
Because a conventional isolation system with constant isolation frequency is usually a long‐period dynamic system, its seismic response is likely to be amplified in earthquakes with strong long‐period wave components, such as near‐fault ground motions. Seismic isolators with variable mechanical properties may provide a promising solution to alleviate this problem. To this end, in this work sliding isolators with variable curvature (SIVC) were studied experimentally. An SIVC isolator is similar to a friction pendulum system (FPS) isolator, except that its sliding surface has variable curvature rather being spherical. As a result, the SIVC's isolation stiffness that is proportional to the curvature becomes a function of the isolator displacement. By appropriately designing the geometry of the sliding surface, the SIVC is able to possess favorable hysteretic behavior. In order to prove the applicability of the SIVC concept, several prototype SIVC isolators, whose sliding surfaces are defined by a sixth‐order polynomial function, were fabricated and tested in this study. A cyclic element test on the prototype SIVC isolators and a shaking table test on an SIVC isolated steel frame were all conducted. The results of both tests have verified that the prototype SIVC isolators do indeed have the hysteretic property of variable stiffness as prescribed by the derived formulas in this study. Moreover, it is also demonstrated that the proposed SIVC is able to effectively reduce the isolator drift in a near‐fault earthquake with strong long‐period components, as compared with that of an FPS system with the same friction coefficient. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

13.
基于神经网络的滑移隔震结构智能半主动控制   总被引:1,自引:1,他引:0  
考虑上部结构的刚度和阻尼,使用神经网络控制算法计算基底摩擦力的大小,研究了滑移隔震结构的半主动控制。对计算实例的分析表明,通过半主动控制的滑移隔震结构不但具有较好的隔震效果,且能有效地减小基底的最大滑移量及残余位移。为对比各种控制方法的控制效果,文中还利用Bang-Bang控制和瞬时最优控制算法对滑移隔震结构进行了半主动控制。对比分析表明,基于神经网络控制算法的控制效果优于其它控制算法,具有反馈量少,稳健性强等特点。  相似文献   

14.
基于动力学基本原理,建立非规则桥梁的多自由度动力简化模型,根据拉格朗日方程推导简化模型的动力方程,结合龙格—库塔方法,采用自编程序研究行波激励下非规则桥梁综合考虑支座摩擦滑移、结构碰撞等非线性因素作用时的抗震性能。结果表明,行波效应和碰撞效应的共同作用可使矮墩的弯矩需求增大;行波激励可使板式橡胶支座位移增大,地震波最后到达的桥墩其上方支座位移峰值增加最为明显;相比高墩,地震作用下矮墩上部的板式橡胶支座易发生滑动。因此非规则桥梁进行防碰撞设计时应考虑行波激励及支座摩擦,找出相邻结构的最大碰撞力,以指导设计。  相似文献   

15.
Sliding isolators with curved surface are effective base isolation systems incorporating isolation, energy dissipation and restoring mechanism in one unit. However, practical utility of these systems, such as friction pendulum system (FPS) has limitations due to constant isolator period and restoring force characteristics. A new isolator called the variable frequency pendulum isolator (VFPI) that overcomes these limitations while retaining all the advantages has been described in this paper. VFPI has oscillation frequency decreasing with sliding displacement, and the restoring force has an upper bound so that the force transmitted to the structure is limited. The mathematical formulations for the response of a SDOF structure and energy balance are also described. Parametric studies have been carried out to critically examine the behaviour of structures isolated with VFPI, FPS and PF system. From these investigations, it is concluded that the VFPI combines the advantages of both FPS and PF system, without their undesirable properties. The VFPI performance is also found to be stable during low‐intensity excitations, and fail‐safe during high‐intensity excitations. VFPI is found to exhibit robust performance for a wide range of structure, isolator and ground motion characteristics clearly demonstrating its advantages. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

16.
采用大型通用有限元程序,对低硬度大直径橡胶隔震支座在竖向荷载作用下的基本性能进行了精细有限元分析。分析了在竖向荷载作用下支座上下封板、内部钢板的各种应力分布,以及支座顶部是否施加竖向同位移约束、支座孔径比、橡胶材料G值、内部单层橡胶厚度与内部单层钢板厚度之比对支座内钢板受力的影响。结果表明,内部钢板最大Mises应力、最大径向水平正应力约为支座竖向压力的4倍、2.5倍;支座顶部是否施加竖向同位移约束对支座用钢板内力影响较大,特别是支座上封板;橡胶G值的变化对内部钢板受力基本没影响;支座孔径比对靠近孔边缘部分内部钢板应力不均匀性分布影响较大;内部单层橡胶厚度与内部单层钢板厚度的比值对内部钢板的Mises应力、径向正应力、环向正应力影响较大,但对其竖向正应力基本没影响。  相似文献   

17.
The use of base isolation in developed countries including the U.S. and Japan has already been recognized as a very effective method for upgrading the seismic resistance of structures. In this study, an advanced base‐isolation system called the multiple friction pendulum system (MFPS) is investigated to understand its performance on seismic mitigation through full‐scale component and shaking table tests. The component tests of the advanced Teflon composite coated on the sliding surface show that the friction coefficient of the lubricant material is a function of the sliding velocity in the range of 0.03–0.12. The experimental results also indicate that there were no signs of degradation of the sliding interface observed after 2000 cycles of sliding displacements. A full‐scale MFPS isolator under a vertically compressive load of 8830 KN (900 tf) and horizontally cyclic displacements was tested in order to assess the feasibility of the MFPS isolator for its practical use. After 248 cycles of horizontal displacement reversals, the behaviour of the base isolator was almost identical to its behaviour during the first few cycles. The experimental results of the shaking table tests of a full‐scale steel structure isolated with MFPS isolators show that the MFPS device can isolate seismic transmitted energy effectively under soft‐soil‐deposit site earthquakes with long predominant periods as well as strong ground motions with short predominant periods. These test results demonstrate that the MFPS isolator possesses excellent durability and outstanding earthquake‐proof capability. Furthermore, the numerical results show that the mathematical model proposed in this study can well predict the seismic responses of a structure isolated with MFPS isolators. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

18.
利用接触摩擦单元建立了滑动摩擦隔震桥梁支座在竖向地震动作用下的有限元模型,通过算例讨论了竖向地震动对不同支座摩擦系数和不同刚度(墩径)滑动摩擦隔震桥梁地震反应的影响,初步探讨了竖向地震动的激励方向对分析结果的影响,分析结果表明,竖向地震动对滑动摩擦隔震桥梁结构的地震反应有较大的影响,在竖向地震动较为明显地区的滑动摩擦隔震桥梁结构设计时,应予以考虑。  相似文献   

19.
本文通过对不同参数的橡胶支座在压缩剪切变形状态下的竖向变形量进行了试验,分析了在压缩剪切变形状态下竖向变形量的特点。得出对RB支座,由剪切和弯曲产生的竖向变形随剪切应变增加而增大较快;对LRB支座,在达到一定剪切应变时,竖向变形量的增加缓慢。  相似文献   

20.
This paper presents an experimental research aimed at developing a new rubber‐based seismic isolator called ‘Ball Rubber Bearing (BRB)’. The BRB is composed of a conventional steel‐reinforced multi‐layered rubber bearing with its central hole filled with small diameter steel balls that are used to provide energy dissipation capacity through friction. A large set of BRBs with different geometrical and material properties are manufactured and tested under reversed cyclic horizontal loading at different vertical compressive load levels. Extensive test results indicate that steel balls do not only increase the energy dissipation capacity of the elastomeric bearing (EB), but also increase its horizontal and vertical stiffness. It is also observed that the energy dissipation capacity of a BRB does not degrade as the number of loading cycles increases. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   