The effect of a base geogrid layer below the geocell mattress in sand, sand overlying soft clay, and soft clay foundation beds has been studied using a series of laboratory scale load tests. A rigid circular model footing was used to apply static monotonic loading on the foundation beds with and without geocell reinforcement. The model test results show that the provision of an additional layer of planar geogrid at the base of the geocell mattress further increases the performance of the footing in terms of bearing capacity and reduction in surface heave of the foundation bed. It is also observed that the beneficial effect of the base geogrid layer becomes negligible with increasing height of the geocell mattress beyond the influence of the depth of the footing. Strain measurements in the base geogrid layer indicate that it is more effective with the limited heights of the geocell mattress. The earth pressure cells embedded in the subgrade soil provide evidence that when the base geogrid is provided below the geocell mattress, the footing pressure is distributed more uniformly over an extended area.  相似文献   

2.
The pull-out resistance of reinforcing elements is one of the most significant factors in increasing the bearing capacity of geosynthetic reinforced soils. In this research a new reinforcing element that includes elements (anchors) attached to ordinary geogrid for increasing the pull-out resistance of reinforcements is introduced. Reinforcement therefore consists of geogrid and anchors with cubic elements that attached to the geogrid, named (by the authors) Grid-Anchor. A total of 45 load tests were performed to investigate the bearing capacity of square footing on sand reinforced with this system. The effect of depth of the first reinforcement layer, the vertical spacing, the number and width of reinforcement layers, the distance that anchors are effective, effect of relative density, low strain stiffness and stiffness after local shear were investigated. Laboratory tests showed that when a single layer of reinforcement is used there is an optimum reinforcement embedment depth for which the bearing capacity is the greatest. There also appeared to be an optimum vertical spacing of reinforcing layers for multi-layer reinforced sand. The bearing capacity was also found to increase with increasing number of reinforcement layer, if the reinforcement were placed within a range of effective depth. The effect of soil density also is investigated. Finally the results were compared with the bearing capacity of footings on non-reinforced sand and sand reinforced with ordinary geogrid and the advantages of the Grid-Anchor were highlighted. Test results indicated that the use of Grid-Anchor to reinforce the sand increased the ultimate bearing capacity of shallow square footing by a factor of 3.0 and 1.8 times compared to that for un-reinforced soil and soil reinforced with ordinary geogrid, respectively.  相似文献   

3.
In the present study, an approximate method has been suggested to calculate the ultimate bearing capacity of a square footing resting on reinforced layered soil. The soil is reinforced with horizontal layers of reinforcement in the top layer of soil only. The pre requisite to the method is the ultimate bearing capacity of unreinforced layered soil, which can be determined from the methods already available in literature. The results have been validated with the model tests conducted on two layered soil compacted at different densities and the top layer reinforced with horizontal layers of geogrid reinforcement.  相似文献   

4.
郑刚  于晓旋  杜娟  尹鑫  周海祚  杨新煜 《岩土力学》2018,39(10):3812-3820
建筑物或构筑物基础临近边坡置放的情况在实际工程中十分普遍,但目前对于临近边坡基础的地基承载力及破坏模式尚缺乏深入研究。采用不连续布局优化(DLO)极限分析法建立数值模型,分析边坡几何尺寸、土体参数和基础位置对临坡条形基础的极限承载力和边坡破坏模式的影响,并对国内外现行规范推荐的计算方法进行评价。结果表明:极限承载力随边坡高度和边坡倾斜角的增大而减小,当坡高超过临界高度后,极限承载力将不受其影响;极限承载力随土体黏聚力和内摩擦角的增大而提高,滑动面随黏聚力的增大而变浅,随内摩擦角的增大而变深;极限承载力随基础与坡肩相对距离的增大而提高,当基础置放位置超过某临界距离后极限承载力不受边坡影响。在土体强度高、坡角较大时,《建筑地基基础设计规范》规定的临坡基础最小置放距离偏于危险,设计时仍需考虑边坡对承载力的减损作用;在土体强度较低、坡角较小时,规范规定值偏于保守。美国AASHTO规范对边坡地基极限承载力的取值在砂土边坡时较为可靠,但其仅适用于坡面破坏模式的情况;饱和黏土边坡的承载力曲线有悖于理论解,对临界距离的规定同样存在低估。  相似文献   

5.
Experimental and numerical investigations into the bearing capacity of circular footing on geogrid-reinforced compacted granular fill layer overlying on natural clay deposit have been conducted in this study. A total of 8 field tests were carried out using circular model rigid footing with a diameter of 0.30 m. 3D numerical analyses were performed to simulate soil behavior using finite element program Plaxis 3D Foundation. The results from the FE analysis are in very good agreement with the experimental observations. It is shown that the degree of improvement depends on thickness of granular fill layer and properties and configuration of geogrid layers. Parameters of the experimental and numerical analyses include depth of first reinforcement, vertical spacing of reinforcement layers. The results indicate that the use of geogrid-reinforced granular fill layers over natural clay soils has considerable effects on the bearing capacity and significantly reduces the lateral displacement and vertical displacement of the footing.  相似文献   

6.
A series of axi-symmetry models using finite element analyses were performed to investigate the behavior of circular footings over reinforced sand under static and dynamic loading. Geogrid was modeled as an elastic element and the soil was modeled using hardening soil model which use an elasto-plastic hyperbolic stress–strain relation. Several parameters including number of geogrid layers, depth to the first geogrid layer, spacing between layers and load amplitude of dynamic loading are selected in this paper to investigate the influence of these parameters on the performance of reinforced systems under both static and dynamic loads. The numerical studies demonstrated that the presence of geogrid in sand makes the relationship between contact pressure and settlement of reinforced system nearly linear until reaching the failure stage. The rate of footing settlement decreases as the number of loading cycles increases and the optimum values of the depth of first geogrid layer and spacing between layers is found 20% of the footing diameter. Some significant observations on the performance of footing-geogrid systems with change of the values of parametric study are presented in this paper.  相似文献   

7.
In this paper, an effort is made to evaluate the seismic bearing capacity of shallow strip footing resting on c–ф soil. The formulation is developed to get a single coefficient of bearing capacity for simultaneous resistance of weight, surcharge and cohesion. Limit equilibrium method in Pseudo-static approach with Coulomb mechanism is applied here to evaluate the seismic bearing capacity. The seismic bearing capacity of footing (quE) is expressed in terms of single coefficient NγE. The effect of various parameters viz. angle of internal friction of soil (ф), angle of wall friction (δ), cohesion (c), ratio of depth to width of footing (df/B0), seismic acceleration (kh, kv) are studied on the variation of seismic bearing capacity co-efficients.  相似文献   

8.
软基路堤桩-网复合地基试验研究   总被引:9,自引:0,他引:9  
徐林荣  牛建东  吕大伟  顾绍付  陈涛 《岩土力学》2007,28(10):2149-2154
桩-网复合地基是近些年发展起来的一种有效的软土地基加固方法,它集复合地基中水平向增强体与竖向增强体两种"单一型"复合地基之长,桩-加筋垫层-桩间土三者协同作用,共同承担上部荷载,其相互作用机理复杂。通过京沪高速铁路试验段中桩-网复合地基处理段进行的路基现场试验,对桩-网复合地基中基底土压力、土工格栅应力应变、桩和土的沉降及地基侧向位移等进行观测测试,分析了桩土应力分担比的变化过程、土工格栅的受力特点、沉降及侧向位移规律,有助于桩-网复合地基各组成部分的承载机理和应力传递机理的深入研究及网垫层对沉降控制的研究,并为提出桩-网复合地基的设计新方法提供一定的依据。  相似文献   

9.
Current studies of bearing capacity for shallow foundations tend to rely on the hypothesis of an isolated footing. In practice a footing is never isolated; it is mostly in interaction with other footings. This paper focuses on a numerical study using the finite-difference code Fast Lagrangian Analysis of Continua (FLAC), to evaluate the bearing capacity for two interfering strip footings, subjected to centered vertical loads with smooth and rough interfaces. The soil is modeled by an elasto-plastic model with a Mohr–Coulomb yield criterion and associative flow rule. The interference effect is estimated by efficiency factors, defined as the ratio of the bearing capacity for a single footing in the presence of the other footing to that of the single isolated footing. The efficiency factors have been computed individually to estimate the effects of cohesion, surcharge, and soil weight using Terzaghi’s equation, both in a frictional soil with surcharge pressures and in a cohesive-frictional soil with surcharge pressures. The results have been compared with those available in the literature.  相似文献   

10.
土工格栅加筋土地基平板载荷试验研究   总被引:2,自引:0,他引:2  
徐超  胡荣  贾斌 《岩土力学》2013,34(9):2515-2520
在近年来的岩土工程实践中,土工合成材料加筋土技术得到越来越广泛的应用。采用平板载荷板试验方法,进行了多组加筋砂土地基模型试验,监测和分析了不同加筋材料(双向格栅与四向格栅)和加筋层数对土工格栅加筋土地基承载特性的影响。研究结果表明:土工格栅加筋土地基与无筋地基相比,承载性能得到改善,双层加筋明显优于单层加筋;土工格栅加筋限制了浅层地基的侧向变形,相同荷载下地基沉降减小,可恢复变形增大;模型试验中测得加筋材料应变和拉力很小,与土工格栅强度相比,拉伸模量对加筋土地基承载力的贡献更大。  相似文献   

11.
Ring footings can be more effective and economical than circular footings. In spite of similarities between circular and ring footings, their behaviors are different in some respects such as bearing pressure distribution under the footing and settlement. But no exclusive theoretical prediction of ultimate bearing capacity has been reported for ring footings. In the present study, stress characteristics method is employed for coding the bearing capacity of ring footing with horizontal ground surface. In the calculations, friction at the contact between the soil and foundation is considered. In this research, the soil obeys the Mohr–Coulomb yield criterion and that is cohesive–frictional-weighted with applied surcharge pressure. The bearing capacity factors Nγ, Nq and Nc for ring footings were calculated by a written code based on the method of characteristics. Bearing capacity was determined for different conditions of soil and different ratio of radii in comparison with the principle of superposition results. The findings show that the principle of superposition is effective for determining the bearing capacity of a ring footing.  相似文献   

12.
In the last decades a few attention was given to the evaluation of the bearing capacity of embedded footing under inclined loads on a frictional soil. This paper focuses on a numerical study using the finite-difference code Fast Lagrangian Analysis of Continua (FLAC), to evaluate the bearing capacity of embedded strip footing on a frictional soil. The soil is modeled by an elasto-plastic model with a Mohr–Coulomb yield criterion and associative flow rule; the effect of non-associativity of the soil on the bearing capacity is also investigated. The effect of the embedment is estimated though a depth factor, defined as a ratio of the bearing capacity of a strip footing at a depth D to that of a strip footing at the ground surface. The inclination effect is estimated by inclination factors, defined as the ratio of the limit vertical load for a footing under inclined loading to that of the vertically loaded footing. Both swipe and probe analyses were carried out to identify the vertical force–horizontal force (V–H) failure envelope. The results have been compared with those available in the literature.  相似文献   

13.
This paper numerically examines the bearing capacity and failure mechanism of a shallow strip foundation constructed above twin voids. The voids may refer to caves, caverns, underground aqueduct or tunnels due to water seepage, chemical reaction or deliberately excavated in soil deposit. The ability of numerical model to accurately predict the system behavior is evaluated by performing verification analyses on existing researches. Subsequently, a parametric study carried out to reveal the influence of size of footing/voids and their location (i.e. depth, spacing, eccentricity) on the bearing capacity of footing. To clarify the failure mechanism, the distribution of shear strain in the soil for different scenarios is assessed. The parametric study provided a new framework to determine the bearing capacity and the mode of failure for footings on voids. Based on the results, a criterion can be issued to avoid collapse of footing/voids regarding the shape, location and size of voids. The results can also be used to design construction of a footing on existing voids while the acquired failure mechanisms can be appointed to develop analytical solutions for this problem. Results demonstrated that a critical depth for voids and a critical distance between them exist where the influence on the ultimate bearing capacity of footing disappears.  相似文献   

14.
The bearing capacity of footing has been studied by both conventional and numerical methods by many researchers. However, degradation of the microstructure of material, that is, a change in the microstructure of the soil, has not been adequately taken into account. Degradation of microstructure causes strain softening of materials and it leads to strain localization such as shear bands and slip bands. From an engineering point of view the strain localization is crucial because it is a precursor of failure. In the present study, finite element analyses of the bearing capacity of a shallow foundation on homogeneous and inhomogeneous saturated clay strata have been conducted using an elasto-viscoplastic soil constitutive model of microstructure change. A series of analyses of footing on clay deposit with different microstructure parameters have been carried out. Numerical results show that strain localization can be predicted during the loading of rigid footing on highly structured soil and strain localization affects the footing–soil interaction. The effects of footing roughness on the failure mechanism are also discussed in the study.  相似文献   

15.
The ultimate bearing capacity of two closely spaced strip footings, placed on a cohesionless medium and loaded simultaneously to failure at the same magnitude of failure load, was determined by using an upper bound limit analysis. A logarithmic spiral radial shear zone, comprising of a number of triangular rigid blocks, was assumed to exist around each footing edge. The equations of the logarithmic spiral arcs were based on angles φL and φR rather than soil friction angle φ; the values of φL and φR were gradually varied in between 0 and φ. The ultimate bearing capacity was found to become maximum corresponding to a certain critical spacing between the footings. For spacing greater than the critical, the bearing capacity was found to decrease continuously with increase in the spacing. The extent of the spacing corresponding to which the ultimate bearing capacity becomes either maximum or equal to that of a single isolated footing increases with increase in φ. The results compare reasonably well with the available theoretical and experimental data.  相似文献   

16.
Reliability analysis of bearing capacity of a strip footing at the crest of a simple slope with cohesive soil was carried out using the random finite element method (RFEM). Analyses showed that the coefficient of variation and the spatial correlation length of soil cohesion can have a large influence on footing bearing capacity, particularly for slopes with large height to footing width ratios. The paper demonstrates cases where a footing satisfies a deterministic design factor of safety of 3 but the probability of design failure is unacceptably high. Isotropic and anisotropic spatial variability of the soil strength was also considered.  相似文献   

17.
A rigorous lower bound solution, with the usage of the finite elements limit analysis, has been obtained for finding the ultimate bearing capacity of two interfering strip footings placed on a sandy medium. Smooth as well as rough footing–soil interfaces are considered in the analysis. The failure load for an interfering footing becomes always greater than that for a single isolated footing. The effect of the interference on the failure load (i) for rough footings becomes greater than that for smooth footings, (ii) increases with an increase in ?, and (iii) becomes almost negligible beyond S/B > 3. Compared with various theoretical and experimental results reported in literature, the present analysis generally provides the lowest magnitude of the collapse load. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

18.
By using the upper bound finite‐elements limit analysis, with an inclusion of single and two horizontal layers of reinforcements, the ultimate bearing capacity has been computed for a rigid strip footing placed over (i) fully granular, (ii) cohesive‐frictional, and (iii) fully cohesive soils. It is assumed that (i) the reinforcements are structurally strong so that no axial tension failure can occur, (ii) the reinforcement sheets have negligible resistance to bending, and (iii) the shear failure can take place between the reinforcement and soil mass. It is expected that the different approximations on which the analysis has been based would generally remain applicable for reinforcements in the form of geogrid sheets. A method has been proposed to incorporate the effect of the reinforcement in the analysis. The efficiency factors, ηc and ηγ, to be multiplied with Nc and Nγ , for finding the bearing capacity of reinforced foundations, have been established. The results have been obtained (i) for different values of ? in case of fully granular and cohesive‐frictional soils, and (ii) for different rates at which the cohesion increases with depth for a fully cohesive soil. The optimum positions of the reinforcements' layers have also been determined. The effect of the reinforcements' length on the results has also been analyzed. As compared to cohesive soils, the granular soils, especially with higher values of ?, cause a much greater increase in the bearing capacity. The results compare reasonably well with the available theoretical and experimental data from literature. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
在水平-垂直加筋体系研究的基础上,对单向土工格栅设置了加强肋,使其具备立体加筋效果。通过大量的拉拔试验,研究了带加强肋土工格栅加筋的筋-土界面特性。通过对汇总得到的36组拉拔试验数据进行分析,探讨了肋间距与肋厚对极限拉拔阻力的影响情况。试验结果表明:在相同法向应力作用下,带加强肋土工格栅的极限拉拔阻力明显高于普通土工格栅,其极限拉拔阻力随着加强肋肋厚的增加而显著增加,并随着加强肋肋距的增加而逐渐减小。在试验基础上,进一步分析了带加强肋土工格栅与砂土的相互作用机制,探讨了极限拉拔阻力的影响因素,建立了拉拔阻力理论公式,并将试验结果与理论值比较,二者基本吻合。  相似文献   

20.
The stability of eccentrically loaded strip footings on slopes was investigated using the method of finite element analysis based on the theory of elasto-plasticity. The analysis was done for two different soils involving three levels of slope angle, six footing locations, and two levels of load eccentricity plus central vertical loading. The strip footing analysed was a 3-ft (0.9 m) wide reinforced concrete footing embedded to a depth of 3 ft (0.9 m). The analysis focused on footing settlement, plastic yielding of soil, and ultimate bearing capacity. The results of analysis show that the influence of load eccentricity on footing pressure vs. footing centre settlement is negligibly small. However, the progressive soil yielding and ultimate bearing capacity are greatly affected by load eccentricity. Furthermore, the effect of load eccentricity differs considerably with the load location relative to the footing centre and slope crest. The ultimate bearing capacity for the eccentric load located on the slope side is significantly greater than that for the load located on the other side of the footing centre. For a 2(H): 1(V) slope in silty clay, the effect of slope on footing stability decreases with increasing footing location from slope crest as would be expected, and diminishes when the footing is located from the crest at about 5-times the footing width.  相似文献   