首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The effect of collision between adjacent reinforced concrete building frames under multiple earthquakes is investigated in this paper. The four planar frames and the nine different pairs of adjacent reinforced concrete structures of the first companion paper are also examined here, under five real seismic sequences. Such a sequence of earthquakes results in a significant damage accumulation in a structure because any rehabilitation action between any two successive seismic motions cannot be practically materialised because of lack of time. Various parameters are investigated, such as the maximum horizontal displacement of top floor, ductility of columns, permanent displacements and so on. Furthermore, four different separation gaps between the building frames are considered to determine their influence on the behaviour of these frames. It is concluded that in most of the cases, the seismic sequences appear to be detrimental in comparison with the single seismic events. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
This paper examines the seismic response of self-centering prestressed concrete moment resisting frames (SCPC-MRFs) with web friction devices. Nonlinear dynamic analyses under ground motion ensembles corresponding to two seismic hazard levels are performed. The results of SCPC-MRFs are compared with those of monolithic reinforced concrete (RC) MRFs in terms of global and local responses. Seismic analyses results show that SCPC-MRFs generally experience similar peak story drifts, less beam end rotations, and much smaller residual deformations as compared with those of RC-MRFs. However, it is also found that SCPC-MRFs sustained larger column plastic rotations than RC-MRFs and are more sensitive to the formation of a soft story. In general, the 8-story SCPC-MRFs show better seismic performances than the 4-story ones. Mainshock–aftershock analyses show that the incremental effect of aftershock on damage extent is much smaller for the SCPC-MRFs than for the RC-MRFs.  相似文献   

3.
Near‐fault ground motions with forward directivity are characterized by a large pulse. This pulse‐like motion may cause a highly non‐uniform distribution of story ductility demands for code‐compliant frame structures, with maximum demands that may considerably exceed the level of code expectations. Strengthening techniques for multi‐story frame structures are explored with the objective of reducing maximum drift demands. One option is to modify the code‐based SRSS distribution of story shear strength over the height by strengthening of the lower stories of the frame. The modified distribution reduces the maximum story ductility demand, particularly for weak and flexible structures. However, this strengthening technique is less effective for stiff structures, and is almost ineffective in cases in which the maximum demand occurs in the upper stories, i.e. strong and flexible structures. As an alternative, the benefits of strengthening frames with elastic and inelastic walls are evaluated. The effects of adding walls that are either fixed or hinged at the base are investigated. It is demonstrated that strengthening with hinged walls is very effective in reducing drift demands for structures with a wide range of periods and at various performance levels. Wall inelastic behavior only slightly reduces the benefits of strengthening with hinged walls.Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

4.
5.
剪切型结构的抗震强度折减系数研究   总被引:1,自引:0,他引:1  
为了研究剪切型结构抗震强度需求的变化规律,本文基于单自由度体系的非线性时程分析,研究了不同场地条件下延性折减系数与位移延性系数和结构自振周期的关系;采用修正等效单自由度体系位移延性折减系数的方法,研究了剪切型多自由度体系的延性折减系数;以基于中国建筑抗震规范设计的代表不同抗震能力要求的RC框架结构为分析对象,通过静力弹塑性分析,研究了RC框架结构的体系超强能力。分析结果表明场地类别、位移延性水准和结构振动周期对单自由度体系的延性折减系数有显著的影响;多自由度体系的抗震延性折减系数明显比其相应的等效单自由度体系的抗震延性折减系数小;RC框架结构的超强系数一般随结构楼层数的增加而减小,随抗震设防烈度的增大而减小,内框架的超强系数比边框架的超强系数大。  相似文献   

6.
Nonlinear behaviour of RC frames under repeated strong ground motions   总被引:1,自引:0,他引:1  
This paper presents an extensive parametric study on the inelastic response of eight reinforced concrete (RC) planar frames which are subjected to forty five sequential ground motions. Two families of regular and vertically irregular (with setbacks) frames are examined. The first family has been designed for seismic and vertical loads according to European codes while the second one only for vertical loads, to study structures which have been constructed before the introduction of adequate seismic design code provisions. The whole range of frames is subjected to five real seismic sequences which are recorded by the same station, in the same direction and in a short period of time, up to three days. In such cases, there is a significant damage accumulation as a result of multiplicity of earthquakes, and due to lack of time, any rehabilitation action is impractical. Furthermore, the examined frames are also subjected to forty artificial seismic sequences. Comprehensive analysis of the created response databank is employed in order to derive important conclusions. It is found that the sequences of ground motions have a significant effect on the response and, hence, on the design of reinforced concrete frames. Furthermore, it is concluded that the ductility demands of the sequential ground motions can be accurately estimated using appropriate combinations of the corresponding demands of single ground motions.  相似文献   

7.
Results from an investigation aimed at assessing seismic behavior of transfer story connections for high‐rise building consisting of steel‐reinforced concrete (SRC) frame and reinforced concrete (RC) core tube are presented. Two types of transfer story connections were experimentally evaluated for adequate strength, ductility and energy dissipation. For each type of connection, two large‐scale subassembly tests were carried out under monotonic and cyclic lateral displacement, respectively. Detailed observations and behavior responses were obtained to contrast the differences between monotonic and cyclic performance of the connections. Test results showed that the SRC column failed before connection collapse and that loading types have little effect on the strength but greatly affect the failure modes and the ductility of the connections. All specimens exhibited good properties for earthquake resistance since they all kept a stable inelastic behavior up to the interstory drift demand suggested by the AISC Seismic Provisions. Based on test observations, support stiffeners with appropriate width‐to‐thickness ratio and mechanical connectors connecting bars with the steel plate are recommended for design purposes in order to achieve more ductile and reliable seismic behavior of transfer story connections. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
以线性粘滞阻尼器加固剪切型规则框架结构为研究对象,基于能量原理提出附加阻尼系数正比于层间位移平方的分配方式。以六层和十二层钢筋混凝土框架为例,以确保结构在中震时保持弹性状态为设计目标,分别采用附加阻尼系数正比于层间位移平方的分配方式以及现有的分配方式,对结构进行消能减震设计。计算结果表明:有控结构均满足中震不坏的要求,层间位移角限值均未超过1/550,减震效果良好;附加阻尼系数正比于层间位移平方的分配方式得出的总阻尼系数最小,为最经济的设计结果。  相似文献   

9.
The effect of stiffness degradation in reinforced concrete structural members on the inelastic response of multistorey buildings to earthquakes is investigated. In particular, the following question is examined. How do the ductility requirements for multistorey systems with degrading stiffness behaviour compare with those for structures with ordinary bilinear hysteretic property? Inelastic dynamic responses of two idealized multistorey buildings, one having a long and the other a relatively short fundamental period, to an ensemble of twenty simulated earthquakes representative of moderately intense ground motions in California at moderate epicentral distances on firm ground, are analysed for ordinary bilinear hysteretic behaviour and for bilinear hysteretic behaviour with stiffness degradation property. The conclusions deduced from the results of this investigation include the following (1) It is, in general, not possible to predict the maximum response of a degrading stiffness system from results for the corresponding ordinary bilinear system (2) The differences in ductility requirements due to stiffness degradation are generally smaller than those associated with probabilistic variability from one ground motion to another (3) Stiffness degradation has little influence on the ductility requirements for flexible buildings, but it leads to increased ductility requirements for stiff buildings.  相似文献   

10.
The inelastic seismic torsional response of simple structures is examined by means of shear‐beam type models as well as with plastic hinge idealization of one‐story buildings. Using mean values of ductility factors, obtained for groups of ten earthquake motions, as the basic index of post‐elastic response, the following topics are examined with the shear‐beam type model: mass eccentric versus stiffness eccentric systems, effects of different types of motions and effects of double eccentricities. Subsequently, comparisons are made with results obtained using a more realistic, plastic hinge type model of single‐story reinforced concrete frame buildings designed according to a modern Code. The consequences of designing for different levels of accidental eccentricity are also examined for the aforementioned frame buildings. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

11.
Qu  Zhe  Gong  Ting  Li  Qiqi  Wang  Tao 《地震工程与工程振动(英文版)》2019,18(2):315-330
The fishbone model is a simplified numerical model for moment-resisting frames that is capable of modelling the effects of column-beam strength and stiffness ratios. The applicability of the fishbone model in simulating the seismic responses of reinforced concrete moment-resisting frames of different sets of column-beam strength and stiffness ratios are evaluated through nonlinear static, dynamic and incremental dynamic analysis on six prototype buildings of 4-, 8-and 12-stories. The results show that the fishbone model is practically accurate enough for reinforced concrete frames, although the assumption of equal joint rotation does not hold in all cases. In addition to the ground motion characteristics and the number of stories in the structures, the accuracy of the model also varies with the column-beam stiffness and strength ratios. The model performs better for strong column-weak beam frames, in which the lateral drift patterns are better controlled by the continuous stiffness provided by the strong columns. When the inelastic deformation is large, the accuracy of the model may be subjected to large record-to-record variability. This is especially the case for frames of weak columns.  相似文献   

12.
A new isolation interface is proposed in this study to retrofit existing buildings with inadequate soft stories as well as new structures to be constructed with soft first story intended for architectural or functional purposes. The seismic interface is an assembly of bearings set in parallel on the top of the first story columns: the multiple‐slider bearings and rubber bearings. The multiple‐slider bearing is a simple sliding device consisting of one horizontal and two inclined plane sliding surfaces based on polytetrafluoroethylene and highly polished stainless steel interface at both ends set in series. A numerical example of a five‐story reinforced concrete shear frame with soft first story is considered and analyzed to demonstrate the efficiency of the proposed isolation system in reducing the ductility demand and damage in the structure while maintaining the superstructure above the bearings to behave nearly in the elastic range with controlled bearing displacement. Comparative study with the conventional system as well as various isolation systems such as rubber bearing interface and resilient sliding isolation is carried out. Moreover, an optimum design procedure for the multiple‐slider bearing is proposed through the trade‐off between the maximum bearing displacement and the first story ductility demand ratio. The results of extensive numerical analysis verify the effectiveness of the multiple‐slider bearing in minimizing the damage from earthquake and protecting the soft first story from excessively large ductility demand. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
Performance-based earthquake engineering is a recent focus of research that has resulted in widely developed design methodologies due to its ability to realistically simulate structural response characteristics.Precise prediction of seismic demands is a key component of performance-based design methodologies.This paper presents a seismic demand evaluation of reinforced concrete moment frames with medium ductility.The accuracy of utilizing simplified nonlinear static analysis is assessed by comparison against the results of time history analysis on a number of frames.Displacement profiles,drift demand and maximum plastic rotation were computed to assess seismic demands.Estimated seismic demands were compared to acceptance criteria in FEMA 356.The results indicate that these frames have sufficient capacity to resist interstory drifts that are greater than the limit value.  相似文献   

14.
In this study life‐cycle cost (LCC) assessment of structural frames is performed. Two different materials, reinforced concrete (RC) and reinforced engineered cementitious composites (ECC), with different response characteristics are used to model the frames. ECC is characterized by high tensile ductility and energy absorption and reduced crack widths when compared to conventional concrete. However, the material is more expensive than conventional concrete; therefore, in order to quantify the potential benefits that could be obtained by replacing concrete with ECC, the life‐cycle performance is evaluated in an optimization framework. Three different structural frames are considered: an RC only frame, an ECC only frame and a multi‐material (MX) frame in which ECC is selectively applied at the potential plastic hinge locations while the remainder of the frame is made of RC. The structural capacity and earthquake demand are evaluated using rigorous analysis methods to capitalize on different characteristics of concrete and ECC, and both aleatory and epistemic uncertainties are incorporated into the LCC formulation. It is found that both the initial and LCC of frames that use ECC are lower due to savings in material and labor cost of transverse reinforcement for the former and due to increased capacity and reduced demand for the latter. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
Damage to buildings observed in recent earthquakes suggests that many old reinforced concrete structures may be vulnerable to the effects of severe earthquakes. One suitable seismic retrofit solution is the installation of steel braces to increase the strength and ductility of a building. Steel bracings have some compelling advantages such as their comparatively low weight, their suitability for prefabrication, and the possibility of openings for utilities, access, and light. The braces are typically connected to steel frames that are fixed to the concrete structure using post‐installed concrete anchors along the perimeter. However, these framed steel braces are not without some disadvantages such as heavier steel usage and greater difficulties during the installation. Therefore, braces without steel frames appear to be an attractive alternative. In this study, braces were connected to gussets furnished with anchor brackets, which were fixed by means of a few post‐installed concrete anchors. The clear structural system and the increased utilization of the anchors allowed the anchorage to be designed precisely and economically. The use of buckling‐restrained braces (BRBs) provides additional benefits in comparison with conventional braces. BRBs improve the energy dissipation efficiency and allow the limitation of the brace force to be taken up by the highly stressed anchorage. Cyclic loading tests were conducted to investigate the seismic performance of BRBs connected with post‐installed anchors used to retrofit reinforced concrete frames. The tests showed that the proposed design method is feasible and increases strength as well as ductility to an adequate seismic performance level. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
Fragility functions are derived for low-rise code compliant & non-compliant special moment resisting frames (SMRFs). Non-compliant SMRFs those built in low strength concrete and lacking confining ties in joint panel zones, commonly found in developing countries. Shake table tests were performed on single-storey and two-storey 1:3 reduced scale representative frames to understand the damage mechanism and develop deformation-based damage scale. The non-compliant SMRF experienced column flexure cracking, longitudinal bar-slip in beam and observed with cover concrete spalling from the joint panels. The code compliant SMRF experienced flexure cracks in beam/column, and experienced joint cracking under extreme shaking. Numerical modeling technique is developed for inelastic modeling of reinforced concrete frame with beam bar-slip and joint damageability using SeismoStruct. Natural accelerograms were used to analyze the considered frames through incremental dynamic analyses in SeismoStruct. A probabilistic based approach was used to derive fragility functions for the considered frames. An example case study is presented for damageability evaluation of structures for earthquakes of various return periods (43, 72, 475, 2475 years).  相似文献   

17.
Seismic codes estimate the maximum displacements of building structures under the design-basis earthquakes by amplifying the elastic displacements under the reduced seismic design forces with a deflection amplification factor(DAF). The value of DAF is often estimated as ρ× R, where R is the force reduction factor and ρ is the inelastic displacement ratio that accounts for the inelastic action of the structure according to the definition presented by FEMA P695. The purpose of this study is to estimate the ρ-ratio of moment resisting steel frames(MRSFs) designed according to the Egyptian code. This is achieved by conducting a series of elastic and inelastic time-history analyses by two sets of earthquakes on four MRSFs designed according to the Egyptian code and having 2, 4, 8 and 12 stories. The earthquakes are scaled to produce maximum story drift ratios(MSDRs) of 1.0%, 1.5%, 2.0% and 2.5%. The mean values of the ρ-ratio are calculated based on the displacement responses of the investigated frames. The results obtained in this study indicate that the consideration of ρ for both the roof drift ratios(RDRs) and the MSDRs equal to 1.0 is a reasonable estimation for MRSFs designed according to the Egyptian code.  相似文献   

18.
A method is presented to quantify the inelastic seismic resistance of reinforced concrete stack-like structures by non-linear earthquake analysis. The deformed configuration of stack is idealized as an assemblage of beam elements and actual stress–strain relationships of concrete and reinforcing steel are used to evaluate element matrices. Repeated non-linear analyses are performed by gradually increasing the intensity of acceleration time histories to a level where collapse of the stack is observed in primary stresses. The set of time histories thus obtained are then used to define the ultimate intensity of ground motion that the stack can sustain if inelastic deformations are permitted. A procedure is presented to quantify the difference between inelastic seismic resistance and elastic seismic resistance in terms of displacement ductility capacity factors. For seismic design using available inelastic resistance, values of curvature ductility factor demand for the cross-sections of stacks are also presented. © 1997 by John Wiley & Sons, Ltd.  相似文献   

19.
The inelastic earthquake response of eccentric, multistorey, frame‐type, reinforced concrete buildings is investigated using three‐ and five‐storey models, subjected to a set of 10, two‐component, semi‐artificial motions, generated to match the design spectrum. Buildings designed according to the EC8 as well as the UBC‐97 code were included in the investigation. It is found that contrary to what the simplified one‐storey, typical, shear‐beam models predict, the so‐called ‘flexible’ side frames exhibit higher ductility demands than the ‘stiff’ side frames. The substantial differences in such demands between the two sides suggest a need for reassessment of the pertinent code provisions. This investigation constitutes one of the first attempts to study the problem of inelastic torsion by means of realistic, multistorey inelastic building models. Additional studies with similar or even more refined idealizations will certainly be required to arrive at definite results and recommendations for possible code revisions. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

20.
This paper assesses the influence of cyclic and in‐cycle degradation on seismic drift demands in moment‐resisting steel frames (MRF) designed to Eurocode 8. The structural characteristics, ground motion frequency content, and level of inelasticity are the primary parameters considered. A set of single‐degree‐of‐freedom (SDOF) systems, subjected to varying levels of inelastic demands, is initially investigated followed by an extensive study on multi‐storey frames. The latter comprises a large number of incremental dynamic analyses (IDA) on 12 frames modelled with or without consideration of degradation effects. A suite of 56 far‐field ground motion records, appropriately scaled to simulate 4 levels of inelastic demand, is employed for the IDA. Characteristic results from a detailed parametric investigation show that maximum response in terms of global and inter‐storey drifts is notably affected by degradation phenomena, in addition to the earthquake frequency content and the scaled inelastic demands. Consistently, both SDOF and frame systems with fundamental periods shorter than the mean period of ground motion can experience higher lateral strength demands and seismic drifts than those of non‐degrading counterparts in the same period range. Also, degrading multi‐storey frames can exhibit distinctly different plastic mechanisms with concentration of drifts at lower levels. Importantly, degrading systems might reach a “near‐collapse” limit state at ductility demand levels comparable to or lower than the assumed design behaviour factor, a result with direct consequences on optimised design situations where over‐strength would be minimal. Finally, the implications of the findings with respect to design‐level limit states are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏