首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The very long baseline interferometry (VLBI) Intensive sessions are typically 1-h and single-baseline VLBI sessions, specifically designed to yield low-latency estimates of UT1-UTC. In this work, we investigate what accuracy is obtained from these sessions and how it can be improved. In particular, we study the modeling of the troposphere in the data analysis. The impact of including external information on the zenith wet delays (ZWD) and tropospheric gradients from GPS or numerical weather prediction models is studied. Additionally, we test estimating tropospheric gradients in the data analysis, which is normally not done. To evaluate the results, we compared the UT1-UTC values from the Intensives to those from simultaneous 24-h VLBI session. Furthermore, we calculated length of day (LOD) estimates using the UT1-UTC values from consecutive Intensives and compared these to the LOD estimated by GPS. We find that there is not much benefit in using external ZWD; however, including external information on the gradients improves the agreement with the reference data. If gradients are estimated in the data analysis, and appropriate constraints are applied, the WRMS difference w.r.t. UT1-UTC from 24-h sessions is reduced by 5% and the WRMS difference w.r.t. the LOD from GPS by up to 12%. The best agreement between Intensives and the reference time series is obtained when using both external gradients from GPS and additionally estimating gradients in the data analysis.  相似文献   

2.
We present earth rotation results from the ultra-rapid operations during the continuous VLBI campaigns CONT11 and CONT14. The baseline Onsala–Tsukuba, i.e., using two out of the 13 and 17 stations contributing to CONT11 and CONT14, respectively, was used to derive UT1-UTC in ultra-rapid mode during the ongoing campaigns. The latency between a new observation and a new UT1-UTC result was less than 10 min for more than 95% of the observations. The accuracy of the derived ultra-rapid UT1-UTC results is approximately a factor of three worse than results from optimized one-baseline sessions and/or complete analysis of large VLBI networks. This is, however, due to that the one-baseline picked from the CONT campaigns is not optimized for earth rotation determination. Our results prove that the 24/7 operation mode planned for VGOS, the next-generation VLBI system, is possible already today. However, further improvements in data connectivity of stations and correlators as well in the automated analysis are necessary to realize the ambitious VGOS plans.  相似文献   

3.
One-baseline 1-h Very Long Baseline Interferometry (VLBI) Intensive sessions are carried out every day to determine Universal Time (UT1). Azimuthal asymmetry of tropospheric delays around the stations is usually ignored and not estimated because of the small number of observations. In this study we use external information about the asymmetry for the Intensive sessions between Tsukuba (Japan) and Wettzell (Germany), which are carried out on Saturdays and Sundays (1) from direct ray-tracing for each observation at Tsukuba and (2) in the form of linear horizontal north and east gradients every 6 h at both stations. The change of the UT1 estimates is at the 10 μs level with maximum differences of up to 50 μs, which is clearly above the formal uncertainties of the UT1 estimates (between 5 and 20 μs). Spectral analysis reveals that delays from direct ray-tracing for the station Tsukuba add significant power at short periods (1–2 weeks) w.r.t. the state-of-the-art approach, and comparisons with length-of-day (LOD) estimates from Global Positioning System (GPS) indicate that these ray-traced delays slightly improve the UT1 estimates from Intensive sessions.  相似文献   

4.
Modeling path delays in the neutral atmosphere for the analysis of Very Long Baseline Interferometry (VLBI) observations has been improved significantly in recent years by the use of elevation-dependent mapping functions based on data from numerical weather models. In this paper, we present a fast way of extracting both, hydrostatic and wet, linear horizontal gradients for the troposphere from data of the European Centre for Medium-range Weather Forecasts (ECMWF) model, as it is realized at the Vienna University of Technology on a routine basis for all stations of the International GNSS (Global Navigation Satellite Systems) Service (IGS) and International VLBI Service for Geodesy and Astrometry (IVS) stations. This approach only uses information about the refractivity gradients at the site vertical, but no information from the line-of-sight. VLBI analysis of the CONT02 and CONT05 campaigns, as well as all IVS-R1 and IVS-R4 sessions in the first half of 2006, shows that fixing these a priori gradients improves the repeatability for 74% (40 out of 54) of the VLBI baseline lengths compared to fixing zero or constant a priori gradients, and improves the repeatability for the majority of baselines compared to estimating 24-h offsets for the gradients. Only if 6-h offsets are estimated, the baseline length repeatabilities significantly improve, no matter which a priori gradients are used.  相似文献   

5.
CONT08 was a 15 days campaign of continuous Very Long Baseline Interferometry (VLBI) sessions during the second half of August 2008 carried out by the International VLBI Service for Geodesy and Astrometry (IVS). In this study, VLBI estimates of troposphere zenith total delays (ZTD) and gradients during CONT08 were compared with those derived from observations with the Global Positioning System (GPS), Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS), and water vapor radiometers (WVR) co-located with the VLBI radio telescopes. Similar geophysical models were used for the analysis of the space geodetic data, whereas the parameterization for the least-squares adjustment of the space geodetic techniques was optimized for each technique. In addition to space geodetic techniques and WVR, ZTD and gradients from numerical weather models (NWM) were used from the European Centre for Medium-Range Weather Forecasts (ECMWF) (all sites), the Japan Meteorological Agency (JMA) and Cloud Resolving Storm Simulator (CReSS) (Tsukuba), and the High Resolution Limited Area Model (HIRLAM) (European sites). Biases, standard deviations, and correlation coefficients were computed between the troposphere estimates of the various techniques for all eleven CONT08 co-located sites. ZTD from space geodetic techniques generally agree at the sub-centimetre level during CONT08, and??as expected??the best agreement is found for intra-technique comparisons: between the Vienna VLBI Software and the combined IVS solutions as well as between the Center for Orbit Determination (CODE) solution and an IGS PPP time series; both intra-technique comparisons are with standard deviations of about 3?C6?mm. The best inter space geodetic technique agreement of ZTD during CONT08 is found between the combined IVS and the IGS solutions with a mean standard deviation of about 6?mm over all sites, whereas the agreement with numerical weather models is between 6 and 20?mm. The standard deviations are generally larger at low latitude sites because of higher humidity, and the latter is also the reason why the standard deviations are larger at northern hemisphere stations during CONT08 in comparison to CONT02 which was observed in October 2002. The assessment of the troposphere gradients from the different techniques is not as clear because of different time intervals, different estimation properties, or different observables. However, the best inter-technique agreement is found between the IVS combined gradients and the GPS solutions with standard deviations between 0.2 and 0.7?mm.  相似文献   

6.
The earth’s phase of rotation, expressed as Universal Time UT1, is the most variable component of the earth’s rotation. Continuous monitoring of this quantity is realised through daily single-baseline VLBI observations which are interleaved with VLBI network observations. The accuracy of these single-baseline observations is established mainly through statistically determined standard deviations of the adjustment process although the results of these measurements are prone to systematic errors. The two major effects are caused by inaccuracies in the polar motion and nutation angles introduced as a priori values which propagate into the UT1 results. In this paper, we analyse the transfer of these components into UT1 depending on the two VLBI baselines being used for short duration UT1 monitoring. We develop transfer functions of the errors in polar motion and nutation into the UT1 estimates. Maximum values reach 30 [μs per milliarcsecond] which is quite large considering that observations of nutation offsets w.r.t. the state-of-the-art nutation model show deviations of as much as one milliarcsecond.  相似文献   

7.
Continuous, very long baseline interferometry (VLBI) campaigns over 2 weeks have been carried out repeatedly, i.e., CONT02 in October 2002, CONT05 in September 2005, CONT08 in August 2008, and CONT11 in September 2011, to demonstrate the highest accuracy the current VLBI was capable at that time. In this study, we have compared zenith total delays (ZTD) and troposphere gradients as consistently estimated from the observations of VLBI, Global Navigation Satellite Systems (GNSS), and Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS) at VLBI sites participating in the CONT campaigns. We analyzed the CONT campaigns using the state-of-the-art software following common processing strategies as closely as possible. In parallel, ZTD and gradients were derived from numerical weather models, i.e., from the global European Centre for Medium-Range Weather Forecasts (ECMWF) analysis fields, the High Resolution Limited Area Model (European sites), the Japan Meteorological Agency-Operational Meso-Analysis Field (MANAL, over Japan), and the Cloud Resolving Storm Simulator (Tsukuba, Japan). Finally, zenith wet delays were estimated from the observations of water vapor radiometers (WVR) at sites where the WVR observables are available during the CONT sessions. The best ZTD agreement, interpreted as the smallest standard deviation, was found between GNSS and VLBI techniques to be about 5–6 mm at most of the co-located sites and CONT campaigns. We did not detect any significant improvement in the ZTD agreement between various techniques over time, except for DORIS and MANAL. On the other hand, the agreement and thus the accuracy of the troposphere parameters mainly depend on the amount of humidity in the atmosphere.  相似文献   

8.
In October 2002, 15 continuous days of Very Long Baseline Interferometry (VLBI) data were observed in the Continuous VLBI 2002 (CONT02) campaign. All eight radio telescopes involved in CONT02 were co-located with at least one other space-geodetic technique, and three of them also with a Water Vapor Radiometer (WVR). The goal of this paper is to compare the tropospheric zenith delays observed during CONT02 by VLBI, Global Positioning System (GPS), Doppler Orbitography Radiopositioning Integrated by Satellite (DORIS) and WVR and to compare them also with operational pressure level data from the European Centre for Medium-Range Weather Forecasts (ECMWF). We show that the tropospheric zenith delays from VLBI and GPS are in good agreement at the 3–7 mm level. However, while only small biases can be found for most of the stations, at Kokee Park (Hawaii, USA) and Westford (Massachusetts, USA) the zenith delays derived by GPS are larger by more than 5 mm than those from VLBI. At three of the four DORIS stations, there is also a fairly good agreement with GPS and VLBI (about 10 mm), but at Kokee Park the agreement is only at about 30 mm standard deviation, probably due to the much older installation and type of DORIS equipment. This comparison also allows testing of different DORIS analysis strategies with respect to their real impact on the precision of the derived tropospheric parameters. Ground truth information about the zenith delays can also be obtained from the ECMWF numerical weather model and at three sites using WVR measurements, allowing for comparisons with results from the space-geodetic techniques. While there is a good agreement (with some problems mentioned above about DORIS) among the space-geodetic techniques, the comparison with WVR and ECMWF is at a lower accuracy level. The complete CONT02 data set is sufficient to derive a good estimate of the actual precision and accuracy of each geodetic technique for applications in meteorology.  相似文献   

9.
The combination of tropospheric parameters derived from different space-geodetic techniques has not been of large interest in geodesy so far. However, due to the high correlation between station coordinates and tropospheric parameters, the latter should not be neglected in combinations. This paper deals with the comparison and combination of tropospheric parameters derived from global positioning system (GPS) and very long baseline interferometry (VLBI) observations stemming from a 15-day campaign of continuous VLBI observations in 2002 (CONT02). The observation data of both techniques were processed homogeneously to avoid systematic differences between the solutions. We compared the tropospheric estimates of GPS and VLBI at eight co-location sites and found a very good agreement in the temporal behavior of the tropospheric zenith path delays (ZPD), reflected by correlation factors up to 0.98. Following this, a combination of the tropospheric parameters was performed. We demonstrate that the combination of tropospheric parameters leads to a stabilization of combined station networks. This becomes visible in the improvement of the repeatabilities of the station height components. Furthermore, the potential use of independent data from water vapor radiometers (WVRs) to validate space-technique-derived tropospheric parameters was investigated. Correlation coefficients of 0.95 or better were estimated between the tropospheric parameters of WVR and GPS or VLBI. Additionally, the utility of the tropospheric parameters for validation of local tie vectors was investigated. Both tropospheric zenith delays and tropospheric gradients were found to be very suitable to validate the height component and the horizontal components of the local tie, respectively.  相似文献   

10.
Real-time orbit determination and interplanetary navigation require accurate predictions of the orientation of the Earth in the celestial reference frame and in particular that for Universal Time UT1. Much of the UT1 variations over periods ranging from hours to a couple of years are due to the global atmospheric circulation. Therefore, the axial atmospheric angular momentum (AAM) forecast series may be used as a proxy index to predict UT1. Our approach taking advantage of this fact is based on an adaptive procedure. It involves incorporating integrations of AAM estimates into UT1 series. The procedure runs on a routine basis using AAM forecasts that are based on the two meteorological series, from the US National Centers for Environmental Prediction and the Japan Meteorological Agency. It is pertinent to test the prediction method for the period that includes the special CONT08 campaign over which we expect a significant improvement in UT1 accuracy. The studies we carried out were aimed both to compare atmospheric forecasts and analyses, as well as to compare the skills of the UT1 forecasts based on the method with atmospheric forecasts and that using current statistical processes, as applied to the C04 Earth orientation parameters series derived by the International Earth rotation and Reference Systems service (IERS). Here we neglect the oceanic sub-diurnal and diurnal variations, as these signals are expected to be smaller than the UT1-equivalent of 100 μs, when averaged over a few days. The prediction performances for a 2-day forecast are similar, but at a forecast horizon of a week, the AAM-based forecast is roughly twice as skillful as the statistically based one.  相似文献   

11.
CONT campaigns are 2-week campaigns of continuous VLBI observations. The IERS working group on combination at the observation level uses these campaigns to study such combinations. In this work, combinations of DORIS, GPS, SLR, and VLBI technique measurements are studied during CONT08. We present different results concerning the use of common zenith tropospheric delay (ZTD) during the combination. We compare the ZTD obtained separately using each individual technique data processing, the combined ZTD, and the ZTD derived from a meteorological model. This resulted in a high level of consistency between each of these ZTD at a sub-centimeter level, a consistency which especially depends on the number of observations per estimated ZTD and the humidity level in the troposphere. We noted that GPS provides the main information about the combined ZTD, the other techniques providing complementary information when a lack of GPS observations occurs.  相似文献   

12.
The correction of tropospheric influences via so-called path delays is critical for the analysis of observations from space geodetic techniques like the very long baseline interferometry (VLBI). In standard VLBI analysis, the a priori slant path delays are determined using the concept of zenith delays, mapping functions and gradients. The a priori use of ray-traced delays, i.e., tropospheric slant path delays determined with the technique of ray-tracing through the meteorological data of numerical weather models (NWM), serves as an alternative way of correcting the influences of the troposphere on the VLBI observations within the analysis. In the presented research, the application of ray-traced delays to the VLBI analysis of sessions in a time span of 16.5 years is investigated. Ray-traced delays have been determined with program RADIATE (see Hofmeister in Ph.D. thesis, Department of Geodesy and Geophysics, Faculty of Mathematics and Geoinformation, Technische Universität Wien. http://resolver.obvsg.at/urn:nbn:at:at-ubtuw:1-3444, 2016) utilizing meteorological data provided by NWM of the European Centre for Medium-Range Weather Forecasts (ECMWF). In comparison with a standard VLBI analysis, which includes the tropospheric gradient estimation, the application of the ray-traced delays to an analysis, which uses the same parameterization except for the a priori slant path delay handling and the used wet mapping factors for the zenith wet delay (ZWD) estimation, improves the baseline length repeatability (BLR) at 55.9% of the baselines at sub-mm level. If no tropospheric gradients are estimated within the compared analyses, 90.6% of all baselines benefit from the application of the ray-traced delays, which leads to an average improvement of the BLR of 1 mm. The effects of the ray-traced delays on the terrestrial reference frame are also investigated. A separate assessment of the RADIATE ray-traced delays is carried out by comparison to the ray-traced delays from the National Aeronautics and Space Administration Goddard Space Flight Center (NASA GSFC) (Eriksson and MacMillan in http://lacerta.gsfc.nasa.gov/tropodelays, 2016) with respect to the analysis performances in terms of BLR results. If tropospheric gradient estimation is included in the analysis, 51.3% of the baselines benefit from the RADIATE ray-traced delays at sub-mm difference level. If no tropospheric gradients are estimated within the analysis, the RADIATE ray-traced delays deliver a better BLR at 63% of the baselines compared to the NASA GSFC ray-traced delays.  相似文献   

13.
Minimal detectable biases of GPS data   总被引:4,自引:1,他引:3  
In this contribution closed-form expressions are given for the minimal detectable biases of single- and dual-frequency pseudo-range and carrier-phase data. They are given for three different single-baseline models. These are the geometry-free model and two variants of the geometry-based model, namely the roving and stationary variants. The baselines are considered to be sufficiently short such that orbital uncertainties in the fixed orbits and residual ionospheric and tropospheric delays can be assumed absent. The stochastic model used is one that permits cross-correlation and the use of different variances for individual GPS observables, including the possibility to weigh the observables in dependence on which satellite is tracked. Received: 23 April 1997 / Accepted: 27 October 1997  相似文献   

14.
为提高电离层总电子含量(total electronic content,TEC)扰动探测参考背景值的预测精度,提出了多尺度自回归移动平均(autoregressive moving average,ARMA)残差修正模型。通过对比该方法、ARMA模型、四分位距法(inter quartile range,IQR)及滑动时窗法对TEC背景值的预测精度,结果显示修正模型预测的TEC背景值平均相对精度为89.78%,分别比ARMA模型、IQR及滑动时窗法高5.18%、1.41%和1.42%,且预测值的残差绝对值小于等于3.0 TECU的百分比为91.67%,明显优于其他3种方法,说明修正模型探测震前TEC异常是可行的。利用该方法探测2013-04-20芦山县Mw7.0级地震震前电离层TEC扰动情况,验证了该方法的有效性。实验结果表明,震前第9天和第13天电离层明显的正异常和震前第1~4天明显的负异常极可能是孕育地震引起的,且正异常主要出现在08:00-10:00 UT,而负异常主要集中在0:00-14:00 UT。  相似文献   

15.
The impact of celestial pole offset modelling on VLBI UT1 intensive results   总被引:1,自引:1,他引:0  
Very Long Baseline Interferometry (VLBI) Intensive sessions are scheduled to provide operational Universal Time (UT1) determinations with low latency. UT1 estimates obtained from these observations heavily depend on the model of the celestial pole motion used during data processing. However, even the most accurate precession- nutation model, IAU 2000/2006, is not accurate enough to realize the full potential of VLBI observations. To achieve the highest possible accuracy in UT1 estimates, a celestial pole offset (CPO), which is the difference between the actual and modelled precession-nutation angles, should be applied. Three CPO models are currently available for users. In this paper, these models have been tested and the differences between UT1 estimates obtained with those models are investigated. It has been shown that neglecting CPO modelling during VLBI UT1 Intensive processing causes systematic errors in UT1 series of up to 20 μas. It has been also found that using different CPO models causes the differences in UT1 estimates reaching 10 μas. Obtained results are applicable to the satellite data processing as well.  相似文献   

16.
Due to the temporal resolution of available numerical weather analyses, the effect of the atmosphere on Earth rotation at daily and sub-daily periods is usually investigated using 6-hourly atmospheric angular momentum (AAM) functions. During the period of CONT08, however, atmospheric analysis data were provided by the European Centre for Medium-Range Weather Forecasts (ECMWF) also on an hourly basis. In this paper, we, therefore, determine two sets of AAM functions from ECMWF data—one for CONT08 with hourly resolution and one for the year 2008 with 6-hourly resolution. The comparisons of the AAM functions to high-resolution Earth rotation parameters (ERP) from VLBI and GPS observations are carried out in the frequency domain. Special attention is paid to the preparation of the high-resolution data sets for the geodetic purposes, as there are jump discontinuities at 12 h intervals. Hence, the hourly AAM functions need to be concatenated. The revised functions yield much smaller amplitudes than their 6-hourly counterparts, as can be seen from the equatorial and the axial frequency spectra of atmospheric excitation in Earth rotation. This decrease of spectral power in the hourly AAM functions is found to be associated with a strong counteraction of pressure and wind terms, which originates from atmospheric circulation on short time scales. The results are compared to previous findings published by Brzeziński and Petrov (IERS Tech Note 28:53–60, 2000) based on the data from the U.S. National Centers for Environmental Prediction (NCEP).  相似文献   

17.
Improved UT1 predictions through low-latency VLBI observations   总被引:2,自引:2,他引:0  
The quality of predictions of Earth orientation parameters (EOPs) in general, and of Universal Time (UT1) in particular, depends strongly on the time delay between the last observation available and the first prediction. Since 30 September 2007 (MJD 54373), the latency of UT1 results from a subset of single baseline VLBI observations running once per week (Mondays) has been decreased from 2 to 3 days to about 8 h. This was achieved by transmitting the raw VLBI data of 1-h duration from the observing sites in Tsukuba (Japan), Wettzell (Germany) and Ny-Ålesund (Norway) to the correlator of the Max-Planck-Institute for Radio Astronomy and the German Federal Agency of Cartography and Geodesy at Bonn, Germany, by high-speed Internet connections (e-Transfer). The reduced latency of the observations has improved the accuracy of the combined International Earth Rotation and Reference Systems Service (IERS) Rapid Service/Prediction Center (RS/PC) UT1-UTC solution by roughly 50% on the days when the data are available. Because this combination is an input to the UT1-UTC prediction process, the improved latency is also responsible for a roughly 21% improvement in the accuracy of short-term IERS RS/PC UT1-UTC predictions on the days where the data are available.  相似文献   

18.
VLBI-derived troposphere parameters during CONT08   总被引:2,自引:2,他引:0  
Time-series of zenith wet and total troposphere delays as well as north and east gradients are compared, and zenith total delays (ZTD) are combined on the level of parameter estimates. Input data sets are provided by ten Analysis Centers (ACs) of the International VLBI Service for Geodesy and Astrometry (IVS) for the CONT08 campaign (12?C26 August 2008). The inconsistent usage of meteorological data and models, such as mapping functions, causes systematics among the ACs, and differing parameterizations and constraints add noise to the troposphere parameter estimates. The empirical standard deviation of ZTD among the ACs with regard to an unweighted mean is 4.6?mm. The ratio of the analysis noise to the observation noise assessed by the operator/software impact (OSI) model is about 2.5. These and other effects have to be accounted for to improve the intra-technique combination of VLBI-derived troposphere parameters. While the largest systematics caused by inconsistent usage of meteorological data can be avoided and the application of different mapping functions can be considered by applying empirical corrections, the noise has to be modeled in the stochastic model of intra-technique combination. The application of different stochastic models shows no significant effects on the combined parameters but results in different mean formal errors: the mean formal errors of the combined ZTD are 2.3?mm (unweighted), 4.4?mm (diagonal), 8.6?mm [variance component (VC) estimation], and 8.6?mm (operator/software impact, OSI). On the one hand, the OSI model, i.e. the inclusion of off-diagonal elements in the cofactor-matrix, considers the reapplication of observations yielding a factor of about two for mean formal errors as compared to the diagonal approach. On the other hand, the combination based on VC estimation shows large differences among the VCs and exhibits a comparable scaling of formal errors. Thus, for the combination of troposphere parameters a combination of the two extensions of the stochastic model is recommended.  相似文献   

19.
利用PANDA软件解算2016年第61~91天的MGEX(Multi-GNSS Experiment)服务站的北斗数据,获得地球自转参数(ERP)。利用VieVS2.2软件处理了同时段的甚长基线干涉测量(VLBI)数据。采用基于IERS 08C04序列的定权方法对BDS和VLBI的解算结果进行加权平均,得到综合的ERP值。结果表明,与IERS比较,极移在X方向差值的RMS为0.249 mas,Y方向差值的RMS为0.296 mas,UT1-UTC差值的RMS为0.053 ms.利用BDS与VLBI数据对ERP参数进行联合解算,弥补了BDS解算结果不稳定和VLBI观测不连续的缺陷,使解算结果的稳定性和可靠性均有所提高。   相似文献   

20.
在国际甚长基线干涉测量(very long baseline interferometry, VLBI)大地测量与天体测量服务组织协调下,首次利用隶属于VLBI全球观测系统(VLBI global observing system, VGOS)的美国Kokee和德国Wettzell观测站及并置的传统VLBI观测站开展了世界时(universal time, UT1)联合测量试验,观测数据在上海VLBI中心进行了干涉处理。结果表明,VGOS超宽带观测系统的UT1测量精度约为7 μs,并置基线的传统S/X双频系统测量精度约为14 μs,VGOS系统的UT1解算结果优于S/X系统。通过试验建立了从相关处理、相关后处理到UT1参数解算的完整数据处理流程,验证了上海VLBI相关处理机的VGOS数据处理能力,为承担国内和国际VGOS观测数据的相关处理任务奠定了基础。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号