首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The dynamic response of tall civil structures due to earthquakes is very important to civil engineers. Structures exposed to earthquakes experience vibrations that are detrimental to their structural components. Structural pounding is an additional problem that occurs when buildings experience earthquake excitation. This phenomena occurs when adjacent structures collide from their out‐of‐phase vibrations. Many energy dissipation devices are presently being used to reduce the system response. Tuned mass dampers (TMD) are commonly used to improve the response of structures. The stiffness and damping properties of the TMD are designed to be a function of the natural frequency of the building to which it is connected. This research involves attaching adjacent structures with a shared tuned mass damper (STMD) to reduce both the structures vibration and probability of pounding. Because the STMD is connected to both buildings, the problem of tuning the STMD stiffness and damping parameters becomes an issue. A design procedure utilizing a performance function is used to obtain the STMD parameters to result in the best overall system response. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

2.
The seismic performance of tuned mass dampers (TMDs) on structures undergoing inelastic deformations may largely depend on the ground motion intensity. By estimating the impact of each seismic intensity on the overall cost of future seismic damages, lifecycle cost (LCC) proves a rational metric for evaluating the benefits of TMDs on inelastic structures. However, no incorporation of this metric into an optimization framework is reported yet. This paper presents a methodology for the LCC‐optimal design of TMDs on inelastic structures, which minimizes the total seismic LCC of the combined building‐TMD system. Its distinctive features are the assumption of a mass‐proportional TMD cost model, the adoption of an iterative suboptimization procedure, and the initialization of the TMD frequency and damping ratios according to a conventional linear TMD design technique. The methodology is applied to the seismic improvement of the SAC‐LA benchmark buildings, taken as representative of standard steel moment‐resisting frame office buildings in LA, California. Results show that, despite their limited performance at the highest intensity levels, LCC‐optimal TMDs considerably reduce the total LCC, to an extent that depends on both the building vulnerability and the TMD unit cost. They systematically present large mass ratios (around 10%) and frequency and damping ratios close to their respective linearly designed optima. Simulations reveal the effectiveness of the proposed design methodology and the importance of adopting a nonlinear model to correctly evaluate the cost‐effectiveness of TMDs on ordinary structures in highly seismic areas.  相似文献   

3.
For super high-rise buildings,the vibration period of the basic mode is several seconds,and it is very close to the period of the fluctuating wind.The damping of super high-rise buildings is low,so super high-rise buildings are very sensitive to fluctuating wind.The wind load is one of the key loads in the design of super high-rise buildings.It is known that only the basic mode is needed in the wind-response analysis of tall buildings.However,for super high-rise buildings,especially for the acceleration response,because of the frequency amplification of the high modes,the high modes and the mode coupling may need to be considered.Three typical super high-rise projects with the SMPSS in wind tunnel tests and the random vibration theory method were used to analyze the effect of high modes on the wind-induced response.The conclusions can be drawn as follows.First,for the displacement response,the basic mode is dominant,and the high modes can be neglected.Second,for the acceleration response,the high modes and the mode coupling should be considered.Lastly,the strain energy of modes can only give the vibration energy distribution of the high-rise building,and it cannot describe the local wind-induced vibration of high-rise buildings,especially for the top acceleration response.  相似文献   

4.
Floor isolation system (FIS) achieving very small floor accelerations has been used to ensure human comfortability or protect important equipments in buildings. Tuned mass damper (TMD) with large mass ratios has been demonstrated to be robust with respect to the changes in structural properties. This paper presents the concept of a TMD floor vibration control system, which takes advantages of both the FIS and TMD. Such a system is called ‘TMD floor system’ herein. The TMD floor system (TMDFS) in which building floors serve as TMDs can achieve large mass ratio without additional masses. Furthermore, multiple TMD floors installed in a building can control multimode vibrations. Then, an optimal design process, where the objective function is set as the maximum magnitude of the frequency response functions of inter‐storey drifts, is proposed to determine the TMD floor parameters. Additionally, the multimode approach is applied to determine the optimal locations of TMD floors if not all of the floors in a building can serve as TMDs. In addition to the numerical simulations, a scaled model shaking table experiment is also conducted. Both the numerical and experimental results show that the absolute accelerations of the TMD floors are smaller than those of the main structural storeys, which indicates the TMDFS maintains the merit of FIS while greatly reducing seismic responses of main structures. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
The optimum parameters of tuned mass dampers (TMD) that result in considerable reduction in the response of structures to seismic loading are presented. The criterion used to obtain the optimum parameters is to select, for a given mass ratio, the frequency (tuning) and damping ratios that would result in equal and large modal damping in the first two modes of vibration. The parameters are used to compute the response of several single and multi-degree-of-freedom structures with TMDs to different earthquake excitations. The results indicate that the use of the proposed parameters reduces the displacement and acceleration responses significantly. The method can also be used in vibration control of tall buildings using the so-called ‘mega-substructure configuration’, where substructures serve as vibration absorbers for the main structure. It is shown that by selecting the optimum TMD parameters as proposed in this paper, significant reduction in the response of tall buildings can be achieved. © 1997 John Wiley & Sons, Ltd.  相似文献   

6.
当前震后建筑经济损失评估模型得到的震后建筑经济损失评估精确度、效率低,针对单一神经网络易产生局部极值等问题,对神经网络方法进行了改进,提出LM-BP神经网络在震后建筑损失评估模型中的应用。输入样本要素为影响震后建筑经济损失的5项因素,输出样本是震后建筑经济损失评估结果,在此基础上采用LM-BP神经网络将训练转化成最小二乘问题,结合LM算法重新定义隐含层节点数量,构建基于LM-BP的神经网络震后经济损失评估模型,采用该模型获取最优震后建筑经济损失评估结果。仿真实验结果表明,所设计的评估模型最小评估误差为0.1%,相比同类模型具有高精确度的优势,是一种可靠的震后建筑经济损失评估模型。  相似文献   

7.
大连国贸大厦高层水箱风振控制研究及应用   总被引:3,自引:1,他引:2  
本文针对一实际工程结构———大连国贸大厦,研究了风荷载作用下调液阻尼器的减振控制作用。首先建立了该结构的简化计算模型,利用Davenport谱给出了模拟风荷载。在大厦所处位置进行多次测量,得到实际风速样本。选取其中风速较大、过程平稳的样本,对实测样本和模拟样本的频谱进行比较,验证了模拟风荷载的合理性。文中将大厦顶层的生活水箱设计成可减小结构位移及加速度反应的控制装置TLD(tuned liqu id damper),根据不同工况进行数值计算,选出最佳方案,设计出可实际应用、并达到一定减振效果的减振水箱,以提高大厦在风荷载作用下的舒适度。  相似文献   

8.
The neuro‐controller training algorithm based on cost function is applied to a multi‐degree‐of‐freedom system; and a sensitivity evaluation algorithm replacing the emulator neural network is proposed. In conventional methods, the emulator neural network is used to evaluate the sensitivity of structural response to the control signal. To use the emulator, it should be trained to predict the dynamic response of the structure. Much of the time is usually spent on training of the emulator. In the proposed algorithm, however, it takes only one sampling time to obtain the sensitivity. Therefore, training time for the emulator is eliminated. As a result, only one neural network is used for the neuro‐control system. In the numerical example, the three‐storey building structure with linear and non‐linear stiffness is controlled by the trained neural network. The actuator dynamics and control time delay are considered in the simulation. Numerical examples show that the proposed control algorithm is valid in structural control. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

9.
One widespread problem in damping estimation of high-rise buildings is the neglect of structural modal directions, which may induce beating in measured dynamic responses along building geometric axes and thereby induce errors in damping estimations to some extent. Based on a proposed two degrees of freedom (2-DOF) simulation model, the effects of neglecting the modal directions on damping estimate are systematically investigated. The results show that the angular differences between the modal directions and the building geometric axes, as well as the frequency difference between the involved modes, both have significant effects on the damping estimate of high-rise buildings. This paper proposes a spectral method to determine the modal directions of high-rise buildings and further validate this method by an analysis of full-scale measurements from four skyscrapers. The damping ratios estimated based on the responses along the identified modal directions are more accurate than those based on those measured along the building geometric axes. Furthermore, an empirical prediction model for damping ratio of high-rise buildings with heights over 200 m is proposed based on the field measured damping results of several buildings with consideration of the modal directions. The objective of this study is to improve the accuracy of damping estimation of high-rise buildings and therefore provide useful information for the structural design of future skyscrapers.  相似文献   

10.
In this paper, the effectiveness of different design solutions for tuned mass dampers (TMD) applied to high‐rise cross‐laminated (X‐Lam) timber buildings as a means to reduce the seismic accelerations was investigated. A seven‐storey full‐scale structure previously tested on shaking table was used as a reference. The optimal design parameters of the TMDs, i.e. damping and frequency ratios, were determined by using a genetic algorithm on a simplified model of the reference structure, composed by seven masses each representing one storey. The optimal solutions for the TMDs were then applied to a detailed finite element model of the seven‐storey building, where the timber panels were modelled with shell elements and the steel connectors with linear spring. By comparing the numerical results of the building with and without multiple TMDs, the improvement in seismic response was assessed. Dynamic time‐history analyses were carried out for a set of seven natural records, selected in accordance with Eurocode 8, on the simplified model, and for Kobe earthquake ground motion on the detailed model. Results in terms of acceleration reduction for different TMD configurations show that the behaviour of the seven‐storey timber building can be significantly improved, especially at the upper storeys. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
地震应急信息的高效处理为地震应急救援工作提供了重要支撑。本文根据地震应急信息分类的需求,构建了一种高效便捷的地震信息分类处理方法。以震前、震时、震后为时间主线,将地震应急信息分为震前基础背景信息、地震震情灾情信息及震后应急救援信息,并采用“关键词分类”的方法,在计算机语言的支持下,将多渠道汇集的应急信息进行自动分类,在一定程度上缩短了应急信息加工处理与服务的时间,能快速高效地为应急指挥提供信息服务。  相似文献   

12.
The paper deals with an application of neural networks for detection of natural periods of vibrations of prefabricated, medium height buildings. The neural network technique is also used to simulate the dynamic response at selected floor of one of the analysed buildings subject to seismic loading induced by explosives in a nearby quarry. Both the training and testing patterns were formulated on the basis of measurements performed on actual structures. The results of neural network identification of natural periods of the considered buildings obtained with different soil, geometrical and stiffness parameters are compared with the results of experiments. The application of back-propagation neural networks enables us to identify the natural periods of the buildings with accuracy quite satisfactory for engineering practice. The experimental and generated data of vibration displacements are compared and much clearer comparison is given on the phase plane: displacements versus velocities. It was stated that a good generalization takes place both with respect to displacements and velocities.  相似文献   

13.
As high‐rise buildings are built taller and more slender, their dynamic behavior becomes an increasingly critical design consideration. Wind‐induced vibrations cause an increase in the lateral wind design loads, but more importantly, they can be perceived by building occupants, creating levels of discomfort ranging from minor annoyance to severe motion sickness. The current techniques to address wind vibration perception include stiffening the lateral load‐resisting system, adding mass to the building, reducing the number of stories, or incorporating a vibration absorber at the top of the building; each solution has significant economic consequences for builders. Significant distributed damage is also expected in tall buildings under severe seismic loading, as a result of the ductile seismic design philosophy that is widely used for such structures. In this paper, the viscoelastic coupling damper (VCD) that was developed at the University of Toronto to increase the level of inherent damping of tall coupled shear wall buildings to control wind‐induced and earthquake‐induced dynamic vibrations is introduced. Damping is provided by incorporating VCDs in lieu of coupling beams in common structural configurations and therefore does not occupy any valuable architectural space, while mitigating building tenant vibration perception problems and reducing both the wind and earthquake responses of the structure. This paper provides an overview of this newly proposed system, its development, and its performance benefits as well as the overall seismic and wind design philosophy that it encompasses. Two tall building case studies incorporating VCDs are presented to demonstrate how the system results in more efficient designs. In the examples that are presented, the focus is on the wind and moderate earthquake responses that often govern the design of such tall slender structures while reference is made to other studies where the response of the system under severe seismic loading conditions is examined in more detail and where results from tests conducted on the viscoelastic material and the VCDs in full‐scale are presented. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
地震作用下钢框架高层结构的抗震性能研究   总被引:1,自引:0,他引:1       下载免费PDF全文
邢磊  贾宝新  邢锐 《地震工程学报》2019,41(6):1482-1487
钢框架高层建筑结构是当前高层建筑设计中使用最为广泛的技术,为提升其抗震性能,本文研究将调谐质量阻尼器安装在钢框架高层建筑结构顶部,考虑到建筑空间需求、防止集中荷载和提升控制效果等因素,在相同楼层或同顶部接近楼层中设置数个较小的、频率一致的子控制装置,通过设置调谐质量阻尼器受控结构等效阻尼比求极值的方法,获取最优刚度与最优阻尼系数;将获取的结果在有限元软件中进行模态分析获取模态质量,实现钢框架高层建筑结构扭转振动的减振控制。实验结果表明,地震荷载下,该方法使得建筑结构顶层角位移峰值和角加速度峰值分别降低50%和30%左右,建筑结构响应下降19%~26%,提高了高层建筑结构的稳定性。  相似文献   

15.
为解决建筑物震害信息提取自动化程度不高的问题,本文将全卷积神经网络应用于建筑物震害遥感信息提取。以玉树地震后获取的玉树县城区0.2m分辨率航空影像作为建筑物震害信息提取试验数据源,将试验区地物划分为倒塌建筑物、未倒塌建筑物和背景3类。对427个500×500像素的子影像进行人工分类与标注,选取393个组成训练样本集,34个用于验证。利用训练样本集对全卷积神经网络进行训练,采用训练后的网络对验证样本进行建筑物震害信息提取及精度评价。研究结果表明:建筑物震害遥感信息提取总体分类精度为82.3%,全卷积神经网络方法能提高信息提取自动化程度,具有较好的建筑物震害信息提取能力。  相似文献   

16.
介绍了第3代结构风振控制基准问题的定义。通过观测部分楼层加速度和控制力输出,建立了模糊神经网络控制器,解决了传统控制中有限的传感器数目对系统振动状态估计的困难;利用模糊神经网络预测结构的控制行为,消除了闭环控制系统中存在的时滞;通过模糊神经网络控制器的学习功能,解决了土木工程复杂结构模糊控制中难以依据专家的主观经验来确定模糊控制规则和语言变量隶属函数等困难。以风振控制的基准问题为研究对象,编制了程序对受控系统进行数值仿真分析。分析表明,模糊神经网络控制策略能有效地抑制高层建筑的风振反应。  相似文献   

17.
Buildings are continually subject to dynamic loads, such as wind load, seismic ground motion, and even the load from internal utility machines. The recent trend of constructing more flexible high‐rise buildings underscores the importance of including viscoelastic dampers in building designs. Viscoelastic dampers are used to control the dynamic response of a building. If the seismic design is based only on the linear response spectrum, considerable error may occur when calculating the seismic response of a building; rubber viscoelastic dampers show non‐linear hysteretic damping that is quite different from viscous damping. This study generated a non‐linear response spectrum using a non‐linear oscillator model to simulate a building with viscoelastic dampers installed. The parameters used in the non‐linear damper model were obtained experimentally from dynamic loading tests. The results show that viscoelastic dampers effectively reduce the seismic displacement response of a structure, but transmit more seismic force to the structure, which essentially increases its seismic acceleration response. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

18.
研究了应用主动锚索控制装置控制相邻建筑地震响应的有效性。首先,建立了主动锚索-相邻建筑系统的运动方程;然后应用广义振型分析方法,寻求了主动锚索联结的相邻建筑的力学特性,特别是振型阻尼比;最后,在频率域内应用广义振型分析与虚拟激励相结合的方法,建立了主动锚索控制装置联结相邻建筑的随机地震响应的分析方法。应用本文建立的公式,我们编制了计算机程序,进行了广泛的参数研究,以评价控制装置的有效性,并确定最优传感器类型及控制装置参数。研究表明,如果应用速度传感器,并能适当地选择主动锚索控制器的参数,则可以显著地提高系统的振型阻尼比,减小两个结构的地震响应。  相似文献   

19.
A new method to design multiple tuned mass dampers (multiple TMDs) for minimizing excessive vibration of structures has been developed using a numerical optimizer. It is a very powerful method by which a large number of design variables can be effectively handled without imposing any restriction before the analysis. Its framework is highly flexible and can be easily extended to general structures with different combinations of loading conditions and target controlled quantities. The method has been used to design multiple TMDs for SDOF structures subjected to wide‐band excitation. Some novel results have been obtained. To reduce displacement response of the structure, the optimally designed multiple TMDs have distributed natural frequencies and distinct damping ratios at low damping level. The obtained optimal configuration of TMDs was different from the earlier analytical solutions and was proved to be the most effective. A robustness design of multiple TMDs has also been presented. Robustness is defined as the ability of TMDs to function properly despite the presence of uncertainties in the parameters of the system. Numerical examples of minimizing acceleration structural response have been given where the system parameters are uncertain and are modeled as independent normal variates. It was found that, in case of uncertainties in the structural properties, increasing the TMD damping ratios along with expanding the TMD frequency range make the system more robust. Meanwhile, if TMD parameters themselves are uncertain, it is necessary to design TMDs for higher damping ratios and a narrower frequency range. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

20.
Modal properties of tuned mass damper (TMD)-structure two-degree-of-freedom (2DOF) linear systems are studied employing a perturbation technique. Using the perturbation solutions, formulas relevant to designing the TMD for various types of loading are obtained; they are expressed as a function of mass ratio, tuning ratio, damping ratio of the TMD and damping ratio of the structure. Equivalent additional dampings of the structure due to the TMD are derived for random and harmonic forces. Matched expressions of equivalent damping, which are valid for detuned, i.e. non-optimal, conditions are also presented. The stability boundary of TMD-structure systems subject to linear self-excited forces is derived in a closed form. Using the perturbation solutions, procedures for optimizing the TMD parameters for various types of loading are explained and the optimal values are derived. The formulas obtained in this study can be used with good accuracy for mass ratios less than 0.02.  相似文献   