首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Data on thirty-four minor and trace elements including all rare earth elements (REE) are reported for two kimberlitic international reference materials (SARM-39, MINTEK, RSA and MY-4, IGEM, Russia) by inductively coupled plasma-mass spectrometry (ICP-MS), some of them for the first time. Four digestion techniques (open acid, closed vessel acid, microwave and lithium metaborate fusion digestion) were used for the decomposition of samples for analysis by ICP-MS. Three other reference materials (USGS BHVO-1, CRPG BR-1 and ANRT UB-N) were analysed simultaneously using the same analytical methodology to assess the precision and accuracy of the determinations. The data obtained in this study compare well with working values wherever such values are available for comparison. Though open acid digestion was found to be very rapid, effective and convenient for the determination of several trace elements in kimberlitic samples, recoveries for heavy rare earth elements (HREE) were lower than the respective recoveries obtained by the other decomposition techniques used. The precision obtained was better than ± 6% RSD in the majority of cases with comparable accuracy. Chondrite-normalised plots of each RM for all the digestion techniques were smooth. The new data reported on the two kimberlitic reference materials make these samples useful for future geochemical studies of kimberlitic rocks.  相似文献   

2.
Trace elements in the Geological Survey of Japan carbonate reference materials Coral JCp-1 and Giant Clam JCt-1 were determined by inductively coupled plasma-mass spectrometry after digestion with 2% v/v HNO3. A standard addition method was adopted in this determination in order to neutralise the Ca matrix effect. In addition, Sc, Y, In and Bi were used as internal standards to control the matrix effect and correct instrumental drift. Of the eighteen elements measured in JCp-1, precisions for fourteen elements, including Cu, Cd and Ba, were better than 10% RSD and concentrations ranged from 0.002 μg g-1 (Cs) to 8.02 μg g-1 (Ba). The concentrations of measured trace elements in JCt-1, except for Cu, were lower than those in JCp-1. Precisions for all elements with concentrations higher than 0.04 μg g-1 in JCt-1 were also better than 10% RSD and concentrations were found to be between 0.001 μg g-1 (Cs) and 4.84 μg g-1 (Ba). The concentrations of more than fifteen trace elements in the aragonite reference materials are reported here for the first time. Both reference materials are suitable for use in geochemical studies of environmental reconstruction based upon biogenic carbonate materials.  相似文献   

3.
We present new reference values for nineteen USGS, GSJ and GIT‐IWG rock reference materials that belong to the most accessed samples of the GeoReM database. The determination of the reference values and their uncertainties at the 95% confidence level follows as closely as possible ISO guidelines and the Certification Protocol of the International Association of Geoanalysts. We used analytical data obtained by the state‐of‐the‐art techniques published mainly in the last 20 years and available in GeoReM. The data are grouped into four categories of different levels of metrological confidence, starting with isotope dilution mass spectrometry as a primary method. Data quality was checked by careful investigation of analytical procedures and by the application of the Horwitz function. As a result, we assign a new and more reliable set of reference values and respective uncertainties for major, minor and a large group of trace elements of the nineteen investigated rock reference materials.  相似文献   

4.
Development of new techniques, enabling simultaneous determination of large numbers of elements in environmental samples, can force analysts to use certified reference materials that do not contain all the elements of interest. In this paper, the mass fractions of forty‐six major and trace elements, including rare earth elements (REE), are presented in one soil (NCS DC 77302 also known as GBW 07410) and five sediment (Metranal‐1, IAEA 405, MESS‐3, NCS DC 73309 also known as GBW 07311 and NCS DC 75301 also known as GBW 07314) certified reference materials determined by high resolution inductively coupled plasma‐mass spectrometry. The selected certified materials represent a spectrum of geological matrices often analysed in environmental studies. Measured elements include certified elements, elements listed with information values as well as new elements absent from certificates, including REEs and some other elements. REE + Y mass fractions in the river sediment reference material Metranal‐1 are reported for the first time. The results obtained are in agreement with available certified or information values.  相似文献   

5.
Data are reported for rare earth elements (REE), Y, Th, Zr, Hf, Nb and Ta in four geological reference materials using sodium peroxide (Na2O2) sintering and inductively coupled plasma-mass spectrometry. The described procedure was used by students during their thesis work. A compilation of their reference material data acquired over one year of laboratory work demonstrates the ease and reliability of the method and the high reproducibility of the analytical results. Relative standard deviations of up to thirty six measurements of one reference material were lower than 5% for Y and the REE. Reproduciblities of Zr, Hf, Nb, Ta and Th were higher at between 5% and 10%, and can be attributed to the inhomogeneous distribution of zircon and other trace mineral phases and uncorrected drift effects. The concentration data are compared to reference and literature values and demonstrate that the procedure is also accurate. New data on G-3 show some systematic deviations from G-2, which are statistically significant.  相似文献   

6.
X射线荧光光谱用人工标准物质的研制   总被引:4,自引:3,他引:1  
使用高纯物质人工合成的方法,成功研制了4个人工标准物质。该系列标准物质涵盖了钛、钒、锰、铬、钴、镍、铜、锌、砷、铅、铋、铷、锶、钇、锆、铌、钼、钨、钕、钽、铪、镱、锡、钡、铯、镓、锗、镧、铈等29个元素,不同分析元素的含量范围可扩大到0.00x%~8%。该系列标准物质不仅可以补充自然标准的不足,扩展校准曲线含量范围,而且能够修正干扰系数,解决了准确计算分析元素之间的干扰和仪器校正带来的实际困难。用4个人工标准物质取代单元素人工标准的配制方法,减少标准数量,节约了资源以及标准配制的时间,避免了X射线荧光光谱分析工作者的重复劳动,提高了工作效率。研制的4个标准物质经检验均匀性和稳定性良好,量值准确可靠,已被国家质量监督检验检疫总局批准为国家一级标准物质。  相似文献   

7.
New data for 21 trace elements including eight rare-earths, determined by neutron activation analysis (NAA) in two rook reference samples (Granite G-2, Andesite AGV-1), are compared with the preferred values previously proposed. Using compiled data published in 1969 and in 1972, further comparisons are made with the preferred means calculated for different methods of trace analysis. NAA data compiled in 1969 and in 1972 and new results published since then are assembled in two tables for the 21 elements. These 1976 NAA data lead us to suggest slight revisions of the preferred values for five to ton elements in each sample.  相似文献   

8.
The concentrations of fifty trace elements, including relatively volatile elements and transition metal elements, in fused glasses of Geological Survey of Japan rock reference materials GSJ JR-2, JA-1, JA-2, JB-1a, JB-3, JGb-1 and JF-1 were determined by particle (proton) induced X-ray emission (PIXE) and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). The fused glasses were prepared by rapid fusion and subsequent quenching in welded platinum capsules and were found to be homogeneous for major elements and for trace elements with concentrations of more than 1 μg g-1 within the observed precision (± 10% mean) on a 70 μm sampling scale. The values obtained by PIXE and LA-ICP-MS for the transition elements (Cr, Mn, Fe, Ni and Cu), the relatively volatile elements (Zn, Ga, Rb and Pb) and the refractory elements (Y, Zr, Nb and Th) with concentrations greater than a few μg g-1 showed good agreement (within 10 % relative difference). The values for almost all the elements detected at concentrations higher than 1 μg g-1 as determined by LA-ICP-MS also agreed well with the reference values (mean relative difference < ± 10%), except for B and Cu. The good agreement confirmed the appropriateness of the NIST SRM 600 series glass calibration reference material for LA-ICP-MS analysis of glasses with variable major-element compositions for almost all elements. The concentrations of Cu in all the samples were lower than the reference values, which was attributed to adsorption of the transition metals onto the platinum capsule during preparation.  相似文献   

9.
The USGS reference glasses GSA-1G, GSC-1G, GSD-1G, GSE-1G, BCR-2G, BHVO-2G and BIR-1G were investigated by different analytical techniques. All these materials have a geological (basaltic) matrix and are therefore useful in igneous geochemistry as matrix-matched reference materials for microanalytical techniques. The new GS glasses have trace elements in groups at concentration levels of about < 0.01, 5, 50 and 500 μg g-1. Their major element compositions have been determined by EPMA, and trace elements have been analysed by LA-ICP-MS and two isotope dilution techniques using TIMS and ICP-MS. EPMA and LA-ICP-MS analyses indicated that the USGS reference glasses are homogeneous at the μm to mm scale with respect to major (variations < 1-2%) and most trace elements (variations 1-4%). Trace element data obtained from the different analytical techniques agreed within an uncertainty of 1-5%, indicating that between method results are comparable. Therefore, the preliminary working values for the four USGS GS glasses calculated from these data have a low level of uncertainty.  相似文献   

10.
We report new data for thirty seven elements determined in twenty six Chinese geochemistry reference materials using inductively coupled plasma-mass spectrometry and a reliable and simple dissolution technique. One hundred milligrams of sample were digested with 1 ml of HF and 0.5 ml of HNO3 in PTFE-lined stainless steel bombs heated to 200 °C for 12 hours. Insoluble residues were dissolved using 6 ml of 40% v/v HNO3 heated to 140 C for 3 hours. Analytical calibration was accomplished using aqueous standard solutions. Rhodium was used as an internal standard to correct for matrix effects and instrument drift. Precisions were typically better than 5% RSD. Most of the data presented here agree well with the published certified values. For the elements Zr, Hf and most other trace elements, the measured values were less than 10% in error when compared to certified values.  相似文献   

11.
Trace element data compiled on, geoshemical reference samples present invariably skewed distributions. It is proposed to treat such data as lognormally distributed and to compute geometric means (Xgm) as probable values. As examples, the Xgm values derived for some trace elements in some rock reference samples are compared with the "recommended" values and with the "gamma" values of Christie.  相似文献   

12.
The United States Geological Survey granitic and granodioritic reference materials G‐2 and GSP‐2 were decomposed in high‐pressure bombs using both HF‐HNO3 and HF‐HNO3‐HClO4 in order to evaluate the feasibility of characterising the entire suite of geologically relevant trace elements through direct analysis with a high‐resolution inductively coupled plasma‐mass spectrometer (HR‐ICP‐MS). The digested samples were diluted to the appropriate levels and analysed at low, medium and high resolution depending on the required sensitivity and potential interferences for each element. Memory effects during analysis of the high field strength elements (HFSE) were negligible when analysed using an all‐Teflon, uncooled sample introduction system and combined with adequate wash times with 4% v/v aqua regia + 0.5% v/v HF between samples. The concentration of the remaining lithophile elements was determined with a conventional, cooled, Scott‐type spray chamber using a wash solution of 1% v/v HNO3. Total procedural blanks contributed between 0.01 to 0.5% to final sample concentrations and blank subtractions were typically unnecessary. Abundances for Li, Hf, Ba, Zr, Ga, Rb, Sr, La, Ce, Th and U were systematically higher, while those for the heavy rare earth elements (HREEs), Cu and Y were systematically lower in this study compared to USGS values for G‐2 and GSP‐2. This is likely to be related to, respectively, higher recoveries from more efficient digestion of refractory phases (i.e., zircon, tourmaline), and better resolution of interferences when using a HR‐ICP‐MS. Sample digestion experiments also showed that perchloric acid digestion in high pressure bombs resulted in superior recoveries and better precision for the bulk of the trace elements analysed. The concentration of the remaining elements overlapped within uncertainty with recommended reference values and with values determined in other studies using isotope‐dilution TIMS, ICP‐MS and XRF. Concentrations for the elements Cd, Sn, Sb, Ta, Bi, Tb, Ni and Mo are also reported for G‐2 and GSP‐2 reference materials. Our study shows therefore that it is feasible to determine thirty‐nine geologically relevant trace elements accurately and directly in granitoid sample digests when using a HR‐ICP‐MS, thereby negating the need for ion exchange or isotopic spiking.  相似文献   

13.
Microanalytical trace element techniques (such as ion probe or laser ablation ICP-MS) are hampered by a lack of well characterized, homogeneous standards. Two silicate glass reference materials produced by National Institute of Standards and Technology (NIST), NIST SRM 610 and NIST SRM 612, have been shown to be homogeneous and are spiked with up to sixty one trace elements at nominal concentrations of 500 μg g-1 and 50 μg g-1 respectively. These samples (supplied as 3 mm wafers) are equivalent to NIST SRM 611 and NIST SRM 613 respectively (which are supplied as 1 mm wafers) and are becoming more widely used as potential microanalytical reference materials. NIST however, only certifies up to eight elements in these glasses. Here we have compiled concentration data from approximately sixty published works for both glasses, and have produced new analyses from our laboratories. Compilations are presented for the matrix composition of these glasses and for fifty eight trace elements. The trace element data includes all available new and published data, and summaries present the overall average and standard deviation, the range, median, geometric mean and a preferred average (which excludes all data outside ± one standard deviation of the overall average). For the elements which have been certified, there is a good agreement between the compiled averages and the NIST data. This compilation is designed to provide useful new working values for these reference materials.  相似文献   

14.
Granite GS-N and Potash Feldspar FK-N are two ANRT reference samples prepared in 1973 in 960 and 567 kg, respectively. All data reported since 1973 are compiled in this report. GS-N and FK-N are now well characterized for major and minor elements. As for trace elements, working values have been assigned for 36 elements in GS-N and for 30 elements in FK-N. We need much more data on trace elements for characterizing them better. As GS-N and FK-N are still available in large quantities and are certain to remain so for two or three decades to come, a plea is made for contribution of more data on trace elements.  相似文献   

15.
地球化学与环境样品分析标准物质和GeoReM数据库   总被引:7,自引:5,他引:2  
在地球化学和环境样品分析中,标准物质发挥着越来越重要的作用。尽管通常要求分析者必须提供量值溯源的测量过程的信息;但大多数论著都未给出标准物质的数据。文章强调标准物质在地球化学分析工作中的重要性,同时将地球化学与环境样品分析标准物质数据库GeoReM介绍给中国的地质分析工作者。GeoReM数据库收录了1880个地球化学和环境样品分析标准物质的定值数据、汇编数据、分析数据及其他相关信息,其中包括156个由中国制备的标准物质的数据。GeoReM数据库还给出了所收录标准物质推荐使用的首选值及其不确定度。尽管这些首选值大多都不是按照国际标准化组织的有关规定而确定的,但是它们的置信度高,因而被广泛应用于仪器校准和分析数据的质量监控。文章还指出要将中国研制的、发表在中文期刊上的标准物质也收录到GeoReM数据库中,这对于促进中国的相关研究,增加国际认可度具有重要意义。  相似文献   

16.
Analytical data for five GSJ (Geological Survey of Japan) reference samples, the "Instrumental analysis series" received by October 1998, are compiled. The data reported in publications and personal communications were evaluated statistically, taking into account the analytical method and sample preparation. Based on the selected available data, recommended and preferred values for fourteen major and fifty one minor and trace elements are proposed.  相似文献   

17.
随着我国对生态文明建设的重视,自然资源综合调查势在必行,对生物标准物质亦提出了新的需求。当前相关调研工作已经大面积开展,自然资源综合调查、农产品与食品安全评价都需要对生物样品元素组成进行准确测试,需要以生物标准物质作为生物成分测试量值比对和溯源的基础,因此对生物基体标准物质的需求量大幅增加。大米作为主要粮食之一,其食品安全日益受到重视,对大米中的化学成分进行准确的分析测试具有重要的现实意义,因而对大米标准物质的需求量尤为突出,但目前大米成分分析标准物质已供不应求。本文严格按照《标准物质定值的通用原则及统计学原理》(JJF 1343—2012)和《地质分析标准物质的研制》(JJF 1646—2017)等相关规范要求,开展了GBW10010a大米成分分析标准物质的复(研)制工作,包括样品采集、加工制备、均匀性检验、稳定性检验、多家实验室协作定值测试及不确定度评定等关键环节。结果表明:本次复(研)制的大米标准物质定值成分多样、量值准确可靠,符合国家一级标准物质的要求。GBW10010a共定值54项主微量元素,包括Ag、Al、As、B、Ba、Be、Bi、Ca、Cd、Ce、Co、Cr、Cs、Cu、Dy、Er、Eu、Fe、Gd、Ge、Hg、Ho、K、La、Li、Ho、Mg、Mn、Mo、N、Na、Nb、Nd、Ni、P、Pb、Pr、Rb、S、Sb、Sc、Se、Si、Sm、Sr、Tb、Th、Tl、Tm、U、V、Y、Yb、Zn,其中的39项元素给出了标准值及不确定度,包括Ag、Al、As、B、Ba、Ca、Cd、Ce、Co、Cs、Cu、Dy、Er、Fe、Hg、K、Li、Mg、Mn、Mo、N、Na、Nd、Ni、P、Pb、Pr、Rb、S、Sb、Se、Si、Sm、Sr、Tb、Tl、Y、Yb、Zn;15项元素提供参考值,包括Be、Bi、Cr、Eu、Gd、Ge、Ho、Ho、La、Nb、Sc、Th、Tm、U、V。与原有GBW10010大米标准物质相比较,GBW10010a中As、Cd、Co、Cr、Cu、Hg、Mn、Mo、Ni、Zn等重金属元素含量显著下降,其中Cd、Cu、Zn降幅较大,分别下降约39%、43%、38.7%,一定程度上反映了农田生态环境的改善。本批标准物质定值元素总数量增加了6项,新增定值元素Ag、Nb(Nb给出参考值),并且各项元素不确定度范围整体上有所缩小,如Al、Cd、Cu、Fe、K、Mg、Mo、Na、P、Pb、Se、Zn等对生物易有影响的重要元素,表明了地质分析测试方法技术的进步及定值水平的提高。本批标准物质定值元素涵盖了具有生物效应的大部分主微量元素,适用于农业生态环境地球化学调查与评价、生物样品测试、农产品质量与食品安全评价样品测试时的分析仪器校正、分析方法评价和分析质量监控等多个领域。  相似文献   

18.
Inductively coupled plasma-mass spectrometry is well suited for the precise, accurate and rapid determination of rare earth elements in most geological samples. However, determination of rare earth elements in certain mantle-derived materials, without applying preconcentration techniques, remains problematical due to low natural concentrations (generally < 1 ng g−1). Consequently, USGS reference materials DTS-1 (a dunite) and PCC-1 (a partially serpentinized harzburgite) have only suggested rather than recommended values for the rare earth elements in reference material compilations. We compared results obtained using two ICP-MS instruments: a U-5000AT ultrasonic nebuliser coupled to a PQ2+ quadrupole ICP-MS and an ELEMENT sector field ICP-MS equipped with a MCN-6000 microconcentric desolvating nebuliser, with the suggested literature values for these two reference materials. Precision and accuracy of analytical methods employed by both instruments were demonstrated by excellent relative standard deviations (< 2%) and inter-laboratory agreement (< 5%) for numerous analyses of BHVO-1 and BIR-1, which are well established with rare earth elements contents at the μg g−1 level. Repeat analyses of DTS-1 and PCC-1 at each laboratory indicate that each method is generally precise to better than 5% at sub-g g−1 levels. Furthermore, values from both instruments generally agree to within 10%. Our DTS-1 and PCC-1 values agree reasonably well with selected data reported in the literature (except for Ce and Sm in DTS-1) but exhibit poorer agreement with reported compilation values. With the demonstrated level of precision and accuracy, we contend that these new values for DTS-1 and PCC-1, generated by two different instruments, are the best estimates of the true whole-rock composition of these samples reported to date.  相似文献   

19.
矽线石成分分析标准物质研制   总被引:1,自引:0,他引:1  
随着矽线石应用领域的逐步拓展,英国、南非和日本等国家已研制了4种矽线石标准物质,而我国仅有一种矽线石国家二级标准物质,无论从组分的浓度梯度范围还是定值指标等方面,均难以满足我国研究需求。本文针对我国矽线石的分布情况,在黑龙江林口县和河南内乡县采集典型矽线石原矿2种,在黑龙江林口县采集矽线石精矿1种,按照国家一级标准物质研制标准和规范要求,研制了3种矽线石成分分析国家一级标准物质(批准编号为GBW07843、GBW07844、GBW07845)。均匀性检验结果表明,除个别指标(Y-1的TFe_2O_3、Cu和J-1的Mn O等)外,3种标准物质检测指标的F值均小于临界值F0.05(24,25)=1.96,组内和组间无明显差异;Y-1的TFe_2O_3、Cu和J-1的MnO等指标的组内和组间差异主要来源于分析方法误差,由此表明此批标准物质均匀性良好。在14个月考察期内,3种标准物质计算得到的拟合直线斜率b1均不显著,表明3种标准物质有较好的稳定性。经我国10家实验室使用多种分析方法对矿石中的主量元素、痕量元素和矽线石含量(硅铝,SAl_2O_3)等共计39种组分联合定值,各组分的相对扩展不确定度处于0.60%~29.9%区间,3种矽线石标准物质主量成分Al_2O_3的含量分别为25.85%、28.16%和55.06%。该系列矽线石标准物质可满足地质、环境等研究领域相关样品分析质量监控工作的需求。  相似文献   

20.
Iron formations (IFs) typically contain low mass fractions of most trace elements, including the rare earth elements (REE), and few publications describe analytical methods dedicated to this matrix. In this study, we used bomb and table‐top acid dissolution procedures and ICP‐MS to determine the mass fractions of trace elements in IF reference materials FER‐1, FER‐2, FER‐3, FER‐4 and IF‐G. The full digestion of the IF samples with the bomb procedure required the addition of a small amount of water together with the acids. The results obtained by this method mostly agreed statistically with published values. The most remarkable exception was the higher values obtained for the heavy REE in FER‐3. The recoveries of the REE obtained with the table‐top procedure were slightly higher than those of the bomb digestion, except for the values of the heavy REE in FER‐3 and FER‐4, which were up to 30% lower than published values. Sintering of the samples with sodium peroxide was performed to determine the REE, but the results tended to be lower than those derived following acid digestion. On the whole, the recoveries showed dependence on the conditions of digestion, but subtle differences in trace mineral composition between samples also exerted influence on the analytical results for trace elements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号