This paper presents the main results of the evaluation of residual inter‐story drift demands in typical moment‐resisting steel buildings designed accordingly to the Mexican design practice when subjected to narrow‐band earthquake ground motions. Analytical 2D‐framed models representative of the study‐case buildings were subjected to a set of 30 narrow‐band earthquake ground motions recorded on stations placed in soft‐soil sites of Mexico City, where most significant structural damage was found in buildings as a consequence of the 1985 Michoacan earthquake, and scaled to reach several levels of intensity to perform incremental dynamic analyses. Thus, results were statistically processed to obtain hazard curves of peak (maximum) and residual drift demands for each frame model. It is shown that the study‐case frames might exhibit maximum residual inter‐story drift demands in excess of 0.5%, which is perceptible for building's occupants and could cause human discomfort, for a mean annual rate of exceedance associated to peak inter‐story drift demands of about 3%, which is the limiting drift to avoid collapse prescribed in the 2004 Mexico City Seismic Design Provisions. The influence of a member's post‐yield stiffness ratio and material overstrength in the evaluation of maximum residual inter‐story drift demands is also discussed. Finally, this study introduces response transformation factors, Tp, that allow establishing residual drift limits compatible with the same mean annual rate of exceedance of peak inter‐story drift limits for future seismic design/evaluation criteria that take into account both drift demands for assessing a building's seismic performance. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
Nowadays, one of the most important methodologies to reduce the destructive effects of severe earthquakes on structures is the use of energy dissipation devices (EDDs). In this paper, a new configuration of special truss moment frame (STMF) systems including EDDs is theoretically proposed to improve their seismic performance. Such an improvement is achieved by provision of bending performance in these frames. For this purpose, the devices called buckling resistant braces (BRBs) are located at the side of beam‐column connections as the top and bottom members of truss‐girders. In this context, a five‐bay nine‐story STMF is designed using the damage and energy concepts recently proposed in the literature. To show the effectiveness of the proposed system with respect to the similar recently presented STMFs, this frame is then subjected to non‐linear static and non‐linear time‐history analyses under several ground motion records in order to survey on its seismic performance. Subsequently, such engineering demand parameters as lateral displacement, inter‐story drift ratio, overturning moment and shearing forces of stories, residual deformations and maximum time‐history displacement at roof level, as well as the process of plastic hinges formation are investigated. The results show the effectiveness of proposed configuration of EDDs used to improve the seismic safety of STMFs. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
A structure that has a permanent offset from a true vertical line is commonly referred to as being ‘out‐of‐plumb’. Out‐of‐plumb may result from construction tolerances or post‐earthquake permanent deformations in steel buildings. This paper quantifies the displacements of buildings with out‐of‐plumb in subsequent seismic events by means of inelastic dynamic time history analysis. Structures considered have different structural heights, force design reduction factors (R), and target inter‐story drifts. It is shown that buildings with greater out of plumb and force design reduction factor have larger normalized peak inter‐story drift ratio and ratio of residual‐to‐peak drift. Also, the ratio of residual‐to‐peak drift was not strongly dependent on structural height or design drift. A design procedure and example provided, based on the results obtained, show how peak and residual inter‐story drift ratio can be estimated. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
Given their excellent self‐centering and energy‐dissipating capabilities, superelastic shape memory alloys (SMAs) become an emerging structural material in the field of earthquake engineering. This paper presents experimental and numerical studies on a scaled self‐centering steel frame with novel SMA braces (SMAB), which utilize superelastic Ni–Ti wires. The braces were fabricated and cyclically characterized before their installation in a two‐story one‐bay steel frame. The equivalent viscous damping ratio and ‘post‐yield’ stiffness ratio of the tested braces are around 5% and 0.15, respectively. In particular, the frame was seismically designed with nearly all pin connections, including the pinned column bases. To assess the seismic performance of the SMA braced frame (SMABF), a series of shake table tests were conducted, in which the SMABF was subjected to ground motions with incremental seismic intensity levels. No repair or replacement of structural members was performed during the entire series of tests. Experimental results showed that the SMAB could withstand several strong earthquakes with very limited capacity degradation. Thanks to the self‐centering capacity and pin‐connection design, the steel frame was subjected to limited damage and zero residual deformation even if the peak interstory drift ratio exceeded 2%. Good agreement was found between the experimental results and numerical simulations. The current study validates the prospect of using SMAB as a standalone seismic‐resisting component in critical building structures when high seismic performance or earthquake resilience is desirable under moderate and strong earthquakes. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
Passive energy dissipation devices are increasingly implemented in frame structures to improve their performance under seismic loading. Most guidelines for designing this type of system retain the requirements applicable to frames without dampers, and this hinders taking full advantage of the benefits of implementing dampers. Further, assessing the extent of damage suffered by the frame and by the dampers for different levels of seismic hazard is of paramount importance in the framework of performance‐based design. This paper presents an experimental investigation whose objectives are to provide empirical data on the response of reinforced concrete (RC) frames equipped with hysteretic dampers (dynamic response and damage) and to evaluate the need for the frame to form a strong column‐weak beam mechanism and dissipate large amounts of plastic strain energy. To this end, shake‐table tests were conducted on a 2/5‐scale RC frame with hysteretic dampers. The frame was designed only for gravitational loads. The dampers provided lateral strength and stiffness, respectively, three and 12 times greater than those of the frame. The test structure was subjected to a sequence of seismic simulations that represented different levels of seismic hazard. The RC frame showed a performance level of ‘immediate occupancy’, with maximum rotation demands below 20% of the ultimate capacity. The dampers dissipated most of the energy input by the earthquake. It is shown that combining hysteretic dampers with flexible reinforced concrete frames leads to structures with improved seismic performance and that requirements of conventional RC frames (without dampers) can be relieved. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
The seismic performance of conventional wood‐frame structures in south‐western British Columbia is analytically investigated through incremental dynamic analysis by utilizing available UBC‐SAWS models, which were calibrated based on experimental test results. To define an adequate target response spectrum that is consistent with information from national seismic hazard maps, record selection/scaling based on the conditional mean spectrum (CMS) is implemented. Furthermore, to reflect complex seismic hazard contributions from different earthquake sources (i.e. crustal events, interface events, and inslab events), we construct CMS for three earthquake types, and use them to select and scale an adequate set of ground motion records for the seismic performance evaluation. We focus on the impacts of adopting different record selection criteria and of using different shear‐wall types (Houses 1–4; in terms of seismic resistance, House 1>House 2>House 3>House 4) on the nonlinear structural response. The results indicate that the record selection procedures have significant influence on the probabilistic relationship between spectral acceleration at the fundamental vibration period and maximum inter‐story drift ratio, highlighting the importance of taking into account response spectral shapes in selecting and scaling ground motion records. Subjected to ground motions corresponding to the return period of 2500 years, House 1 is expected to experience very limited extent of damage; Houses 2 and 3 may be disturbed by minor damage; whereas House 4 may suffer from major damage occasionally. Finally, we develop statistical models of the maximum inter‐story drift ratio conditioned on a seismic intensity level for wood‐frame houses, which is useful for seismic vulnerability assessment. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
The linked column frame (LCF) system is proposed as a seismic load resisting system that uses conventional components to limit seismic damage to relatively easily replaced elements. The LCF features a primary lateral system, denoted the linked column, which is made up of dual columns connected with replaceable links, and a secondary flexible moment frame system with beams having fully restrained connections at one end and simple connections at the other. The linked columns are designed to limit seismic forces and provide energy dissipation via link yielding, while preventing damage to the moment frame under certain earthquake hazard levels. A design procedure is proposed that ensures plastic hinges develop in the links of the linked columns at a significantly lower story drift than when plastic hinges develop in the moment frame beams. The large drift difference helps enable design of this system for two distinct performance states: rapid return to occupancy, where only link damage occurs and relatively simple link replacement is possible, and collapse prevention, where both the links and the beams of the moment frame may be damaged. A series of 3‐story, 6‐story, and 9‐story prototype LCF buildings were designed using the proposed design approach. Nonlinear models were developed for the designs with the link models validated using recent experimental results. The seismic response of these systems was investigated for ground motions representing various seismic hazard levels. Results show that the LCF system not only provides collapse prevention, but also has the capability of limiting economic loss by reducing structural damage and allowing for rapid return to occupancy following earthquakes with shorter return periods. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

8.
A series of pseudo‐dynamic tests (PDTs) of a full‐scale 3‐story 3‐bay buckling‐restrained braced frame (BRBF) using concrete‐filled tube columns was tested in the Taiwan National Center for Research on Earthquake Engineering using networked PDT techniques in October 2003. During the tests, real‐time experimental responses and video were webcasted to Internet viewers. The input ground motions adopted for the PDTs were chosen from the 1999 Chi‐Chi and the 1989 Loma Prieta earthquakes and scaled to represent three seismic hazard levels. This paper is in two parts, focusing on the investigations of the overall structure and the local members. This paper constitutes Part I and discusses the design, analytical investigations, and key experimental results of the specimen frame, such as the buckling of the brace‐to‐gusset joints. Part II of the paper, the companion paper, describes the gusset stiffening schemes and detailed experimental behavior of the BRBs and their connections. Experimental peak inter‐story drifts of 0.019 and 0.023 radians, prescribed for the design basis and the maximum credible earthquakes, respectively, are within the target design limits of 0.020 and 0.025 radians. These tests confirmed that the PISA3D and OpenSees nonlinear structural analysis computer programs can simulate the experimental peak shears and floor displacements well. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

9.
Inter‐story drift displacement data can provide useful information for story damage assessment. The authors' research group has developed photonic‐based sensors for the direct measurement of inter‐story drift displacements. This paper proposes a scheme for evaluating the degree of damage in a building structure based on drift displacement sensing. The scheme requires only measured inter‐story drift displacements without any additional finite element analysis. A method for estimating yield drift deformation is proposed, and then, the degree of beam end damage is evaluated based on the plastic deformation ratios derived with the yield drift deformation values estimated by the proposed method. The validity and effectiveness of the presented scheme are demonstrated via experimental data from a large‐scale shaking table test of a one‐third‐scale model of an 18‐story steel building structure conducted at E‐Defense. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
Reinforced concrete waffle‐flat plate (WFP) structures present 2 important drawbacks for use as a main seismic resisting system: low lateral stiffness and limited ductility. Yet the former can serve a positive purpose when, in parallel, the flexible WFP structure is combined with a stiff system lending high‐energy dissipation capacity, to form a “flexible‐stiff mixed structure.” This paper experimentally investigates the seismic performance of WFP structures (flexible system) equipped with hysteretic dampers (stiff system) through shake‐table tests conducted on a 2/5‐scale test specimen. The WFP structure was designed only for gravitational loads. The lateral strength and stiffness provided by the dampers at each story were, respectively, about 3 and 7 times greater than those of the bare WFP structure. The mixed system was subjected to a sequence of seismic simulations representing frequent to very rare ground motions. Under the seismic simulations associated with earthquakes having return periods ranging from 93 to 1894 years, the WFP structure performed in the level of “immediate occupancy,” with maximum interstory drifts up to about 1%. The dampers dissipated most (75%) of the energy input by the earthquake.  相似文献   

11.
A new floor connecting system developed for low‐damage seismic‐resistant building structures is described herein. The system, termed Inertial Force‐Limiting Floor Anchorage System (IFAS), is intended to limit the lateral forces in buildings during an earthquake. This objective is accomplished by providing limited‐strength deformable connections between the floor system and the primary elements of the lateral force‐resisting system. The connections transform the seismic demands from inertial forces into relative displacements between the floors and lateral force‐resisting system. This paper presents the IFAS performance in a shake‐table testing program that provides a direct comparison with an equivalent conventional rigidly anchored‐floor structure. The test structure is a half‐scale, 4‐story reinforced concrete flat‐plate shear wall structure. Precast hybrid rocking walls and special precast columns were used for test repeatability in a 22‐input strong ground‐motion sequence. The structure was purposely designed with an eccentric wall layout to examine the performance of the system in coupled translational‐torsional response. The test results indicated a seismic demand reduction in the lateral force‐resisting system of the IFAS structure relative to the conventional structure, including reduced shear wall base rotation, shear wall and column inter‐story drift, and, in some cases, floor accelerations. These results indicate the potential for the IFAS to minimize damage to the primary structural and non‐structural components during earthquakes.  相似文献   

12.
This paper proposes a novel implementation of buckling‐restrained braces (BRB) in new reinforced concrete (RC) frame construction. Seismic design and analysis methods for using a proposed steel cast‐in anchor bracket (CAB) to transfer normal and shear forces between the BRB and RC members are investigated. A full‐scale two‐story RC frame with BRBs (BRB‐RCF) is tested using hybrid and cyclic loading test procedures. The BRBs were arranged in a zigzag configuration and designed to resist 70% of the story shear. The gusset design incorporates the BRB axial and RCF actions, while the beam and column members comply with ACI 318‐14 seismic design provisions. Test results confirm that the BRBs enhanced the RCF stiffness, strength, and ductility. The hysteresis energy dissipation ratios in the four hybrid tests range from 60% to 94% in the two stories, indicating that BRBs can effectively dissipate seismic input energy. When the inter‐story drift ratio for both stories reached 3.5% in the cyclic loading test, the overall lateral force versus deformation response was still very stable. No failure of the proposed steel CABs and RC discontinuity regions was observed. This study demonstrates that the proposed design and construction methods for the CABs are effective and practical for real applications. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
This paper experimentally investigates the application of damage avoidance design (DAD) philosophy to moment‐resisting frames with particular emphasis on detailing of rocking interfaces. An 80% scale three‐dimensional rocking beam–column joint sub‐assembly designed and detailed based on damage avoidance principles is constructed and tested. Incremental dynamic analysis is used for selecting ground motion records to be applied to the sub‐assembly for conducting a multi‐level seismic performance assessment (MSPA). Analyses are conducted to obtain displacement demands due to the selected near‐ and medium‐field ground motions that represent different levels of seismic hazard. Thus, predicted displacement time histories are applied to the sub‐assembly for conducting quasi‐earthquake displacement tests. The sub‐assembly performed well reaching drifts up to 4.7% with only minor spalling occurring at rocking beam interfaces and minor flexural cracks in beams. Yielding of post‐tensioning threaded bars occurred, but the sub‐assembly did not collapse. The externally attached energy dissipators provided large hysteretic dissipation during large drift cycles. The sub‐assembly satisfied all three seismic performance requirements, thereby verifying the superior performance of the DAD philosophy. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

14.
The corner gusset plates in a steel braced frame can be subjected to forces not only from the brace but also from the effects of the frame actions. In this study, several finite element models are constructed to analyze the gusset‐to‐beam and gusset‐to‐column interface forces. It is found that the frame actions affect the gusset interface force distributions significantly. A simplified strut model to represent the gusset plate is adopted to evaluate the frame action forces. In addition, the generalized uniform force method is adopted as it provides more freedom for designers to configure the gusset plate shapes than using the uniform force method. In this paper, a performance‐based design method is proposed. The gusset interface force demands take into account the combined effect of the brace maximum axial force capacity and the peak beam shear possibly developed in the frame. The specimen design and key results of a series of full‐scale three‐story buckling‐restrained braced frame (BRBF) hybrid tests are discussed. The gusset interface cracks observed at inter‐story drift greater than 0.03 radians can be well predicted by using the proposed design method. The BRBF tests and analyses confirm that the proposed design method is reasonable. The effectiveness of varying the width of gusset edge stiffeners in reducing the gusset tip stress concentrations is also investigated. This paper concludes with recommendations for the seismic design of BRBF corner gusset plates. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
Post‐earthquake safety evaluation of steel moment‐resisting frames mainly relies on the inspection of seismic damage to beam–column connections. Recently, in order to evaluate seismic damage of steel connections in a prompt and precise manner, a local damage evaluation method based on dynamic strain responses has been proposed and receives attention. In the evaluation method where strain responses are measured by piezoelectric strain sensors, a strain‐based damage index has been developed for evaluating individual seismic beam damage in a steel frame. However, for a steel frame suffering multiple beam damages, the damage index deteriorates its performance in identifying small damages with the presence of neighboring severe damages because of the moment redistributions induced by larger damages. This paper presents a decoupling algorithm that removes the issue of damage interaction and improves the performance of the damage index. The decoupling algorithm was derived on the basis of damage‐induced moment release and redistribution mechanism. The effectiveness of the decoupling algorithm was numerically and experimentally investigated using a nine‐story steel frame model and a large scale five‐story steel frame testbed that can simulate multiple fractures at beam ends. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

16.
A series of hybrid and cyclic loading tests were conducted on a three‐story single‐bay full‐scale buckling‐restrained braced frame (BRBF) at the Taiwan National Center for Research on Earthquake Engineering in 2010. Six buckling‐restrained braces (BRBs) including two thin BRBs and four end‐slotted BRBs, all using welded end connection details, were installed in the frame specimen. The BRBF was designed to sustain a design basis earthquake in Los Angeles. In the first hybrid test, the maximum inter‐story drift reached nearly 0.030 rad in the second story and one of the thin BRBs in the first story locally bulged and fractured subsequently before the test ended. After replacing the BRBs in the first story with a new pair, a second hybrid test with the same but reversed direction ground motion was applied. The maximum inter‐story drifts reached more than 0.030 rad and some cracks were found on the gusset welds in the second story. The frame responses were satisfactorily predicted by both OpenSees and PISA3D analytical models. The cyclic loading test with triangular lateral force distribution was conducted right after the second hybrid test. The maximum inter‐story drift reached 0.032, 0.031, and 0.008 rad for the first to the third story, respectively. This paper then presents the findings on the local bulging failure of the steel casing by using cyclic test results of two thin BRB specimens. It is found that the steel casing bulging resistance can be computed from an equivalent beam model constructed from the steel core plate width and restraining concrete thickness. This paper concludes with the recommendations on the seismic design of thin BRB steel casings against local bulging failure. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
The bidirectional response of a portion of a reinforced concrete (RC) waffle-flat plate (WFP) structure subjected to far-field ground motions is studied through shake table tests. The test specimen is a scaled portion of a prototype structure designed under current building codes and located in a region of moderate seismicity of the Mediterranean area. The specimen was subjected to a sequence of tests of increasing acceleration amplitude that respectively represented very frequent, frequent, design, and very rare earthquakes at the site. The test structure performed well (basically in the elastic domain) under very frequent and frequent earthquakes, approached the boundary between the performance levels of life safety and near collapse under the design earthquake, and collapsed under the very rare earthquake. Damage concentrated at column bases and at the transverse beams of the exterior plate-to-column connection. Columns dissipated about 10% of the total energy that contributes to damage, and the rest was dissipated by the exterior plate-column connection. The total energy input on the structure until collapse under the bidirectional seismic action was very close to the value obtained in previous studies on a similar specimen tested under unidirectional ground motions. The capacity curve estimated from the experimental base shear vs top displacement relationship suggests it is best to use a behavior factor of at most q = 2 when designing WFP structures with the reduced-spectrum force-based approach.  相似文献   

18.
The replaceable coupling beam (RCB) is an innovative structural component developed to increase the seismic resilience of reinforced concrete (RC) shear wall structures. In this study, two 1/5‐scale 5‐story 3‐dimensional RC shear wall structures—one with conventional RC coupling beams and the other with RCBs—were designed, constructed, and tested on a shaking table. The failure pattern, dynamic properties, and structural responses, including the acceleration, displacement, story force, and strain responses, of the 2 structures are compared under earthquake excitations. The test results demonstrate that the seismic performance of the structure with RCBs was improved when RCBs were working compared with the structure with conventional RC coupling beams. In addition, the replaceable devices suffering the severe damage during an earthquake can be conveniently replaced after the earthquake. However, after the sudden failure of RCBs during the severe earthquakes, the inter‐story drift and floor acceleration of the structure with RCBs became larger. The design and manufacture quality of RCBs should be improved to avoid the sudden failure. Then, numerical models for the test structures were established using the commercial software PERFORM‐3D. Numerical simulations of the tests were conducted. The simulation results correspond well with the experimental results, thus verifying the accuracy of the numerical models. The RC shear wall structure installed with RCBs can be applied as a new type of earthquake‐resilient structure in engineering practice.  相似文献   

19.
为研究某海底隧道风塔及下部结构体系在塑性阶段的损伤破坏形态及特点,探讨在多重荷载作用下弹塑性静动力响应对结构的影响,建立了沉管隧道风塔及下部结构的大型三维有限元模型。采用基于能量原理的混凝土塑性及损伤本构模型,借助大型有限元软件ANSYS及ABAQUS分别对结构进行不同地震条件下的动力时程分析,对比分析振型、层间位移角及较为完整的塑性损伤破坏系数曲线。结果表明:不同设防地震下,结构整体性良好,振型及层间位移角满足规范要求;不同罕遇地震下,该结构的混凝土塑性拉压损伤最大时刻均发生在20 s,主要破坏区域在风塔与人防井及下部立柱的接触位置,且拉伸破坏系数明显高于压缩破坏。本文的研究成果可以为类似近海沉管隧道工程抗震设计提供一定的依据与指导。  相似文献   

20.
The seismic damages commonly observed on beam–column joints of old reinforced concrete structures, built with plain bars and without proper detailing, justifies the need to further study the behaviour of this type of structures. The response of these structures when loaded cyclically, as occurs during the earthquakes, is partially controlled by the bond properties between the reinforcing bars and the surrounding concrete. This paper presents the results of an experimental campaign of unidirectional cyclic tests carried out on six full‐scale beam–column joints built with plain bars. These joint specimens are representative of existing reinforced concrete structures, that is, built without adequate reinforcement detailing for seismic demands. For comparison, an additional specimen is built with deformed bars and tested. The seven specimens are designed and detailed to allow the investigation of the influence of bond properties, lapping of the longitudinal bars in columns and beams, bent‐up bars in the beams, slab contribution and concrete strength. The lateral force–drift relationships, global dissipated energy evolution, contribution of the joint, beams and columns to the global dissipated energy, ductility, equivalent damping, final damage observed, homogenized reinforced concrete damage index, displacement components, curvature evolutions and Eurocode requirements are presented and discussed. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   