1.
The rolling motion of mutually orthogonal rollers respectively sandwiched between two bearing plates in which one or both have V‐shaped sloping surfaces makes the sloped rolling‐type isolation device have an excellent in‐plane seismic isolation performance. In this study, the sloped rolling type isolation device in which a single roller moves between two V‐shaped sloping surfaces along each principle horizontal direction is refined by incorporating multi‐roller, built‐in damping, and pounding prevention mechanisms. The associated dynamic behavior is further clarified, and a simplified twin‐flag hysteretic model, which can be easily applied in most commercial computational tools is then proposed. Seismic simulation tests on the refined isolation devices (i.e. the sloped multi‐roller isolation devices) with different design parameters such as sloping angles of bearing plates and built‐in damping capabilities, together with a raised floor system by employing the sloped multi‐roller isolation devices, were conducted. Not only is the efficiency of the sloped multi‐roller isolation devices in seismically protecting the important objects, but also the practicability and accuracy of the proposed simplified numerical model in predicting the seismic responses of the sloped multi‐roller isolation devices is experimentally verified. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
Floor isolation is an alternative to base isolation for protecting a specific group of equipment installed on a single floor or room in a fixed‐base structure. The acceleration of the isolated floor should be mitigated to protect the equipment, and the displacement needs to be suppressed, especially under long‐period motions, to save more space for the floor to place equipment. To design floor isolation systems that reduce acceleration and displacement for both short‐period and long‐period motions, semi‐active control with a newly proposed method using the linear quadratic regulator (LQR) control with frequency‐dependent scheduled gain (LQRSG) is adopted. The LQRSG method is developed to account for the frequency characteristics of the input motion. It updates the control gain calculated by the LQR control based on the relationship between the control gain and dominant frequency of the input motion. The dominant frequency is detected in real time using a window method. To verify the effectiveness of the LQRSG method, a series of shake table tests is performed for a semi‐active floor isolation system with rolling pendulum isolators and a magnetic‐rheological damper. The test results show that the LQRSG method is significantly more effective than the LQR control over a range of short‐period and long‐period motions. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
In order to use rocking as a seismic response modification strategy along both directions of seismic excitation, a three‐dimensional (3D) rocking model should be developed. Since stepping or rolling rocking structural members out of their initial position is not a desirable performance, a rocking design should not involve these modes of motion. To this end, a model that takes the aforementioned constraint into account needs to be developed. This paper examines the 3D motion of a bounded rigid cylinder that is allowed to uplift and sustain rocking and wobbling (unsteady rolling) motion without sliding or rolling out of its initial position (i.e., a 3D inverted pendulum). Thus, the cylinder is constrained to zero residual displacement at the end of its 3D motion. This 3D dynamic model of the rocking rigid cylinder has two DOFs (three when damping is included), making it the simplest 3D extension of Housner's classical two‐dimensional (2D) rocking model. The development of models with and without damping is presented first. They are simple enough to perform extensive parametric analyses. Modes of motion of the cylinder are identified and presented. Then, 3D rocking and wobbling earthquake response spectra are constructed and compared with the classical 2D rocking earthquake response spectra. The 3D bounded rocking earthquake response spectra for the ground motions considered seem to have a very simple linear form. Finally, it is shown that the use of a 2D rocking model may lead to unacceptably unconservative estimates of the 3D rocking and wobbling seismic response. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

4.
Three analytical studies of base‐isolated structures are carried out. First, six pairs of near‐fault motions oriented in directions parallel and normal to the fault were considered, and the average of the response spectra of these earthquake records was obtained. This study shows that in addition to pulse‐type displacements, these motions contain significant energy at high frequencies and that the real and pseudo‐velocity spectra are quite different. The second analysis modelled the response of a model of an isolated structure with a flexible superstructure to study the effect of isolation damping on the performance of different isolation systems under near‐fault motion. The results show that there exists a value of isolation system damping for which the superstructure acceleration for a given structural system attains a minimum value under near‐fault motion. Therefore, although increasing the bearing damping beyond a certain value may decrease the bearing displacement, it may transmit higher accelerations into the superstructure. Finally, the behaviour of four isolation systems subjected to the normal component of each of the near‐fault motions were studied, showing that EDF type isolation systems may be the optimum choice for the design of isolated structures in near‐fault locations. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

5.
Viscous and other damping devices are often used as elements of seismic isolation systems. Despite the widespread application of nonlinear viscous systems particularly in Japan (with fewer applications in the USA and Taiwan), the application of viscous damping devices in isolation systems in the USA progressed intentionally toward the use of supplementary linear viscous devices due to the advantages offered by these devices. This paper presents experimental results on the behavior of seismically isolated structures with low damping elastomeric (LDE) and single friction pendulum (SFP) bearings with and without linear and nonlinear viscous dampers. The isolation systems are tested within a six‐story structure configured as moment frame and then again as braced frame. Emphasis is placed both on the acquisition of data related to the structural system (drifts, story shear forces, and isolator displacements) and on non‐structural systems (floor accelerations, floor spectral accelerations, and floor velocities). Moreover, the accuracy of analytical prediction of response is investigated based on the results of a total of 227 experiments, using 14 historic ground motions of far‐fault and near‐fault characteristics, on flexible moment frame and stiff braced frame structures isolated with LDE or SFP bearings and linear or nonlinear viscous dampers. It is concluded that when damping is needed to reduce displacement demands in the isolation system, linear viscous damping results in the least detrimental effect on the isolated structure. Moreover, the study concludes that the analytical prediction of peak floor accelerations and floor response spectra may contain errors that need to be considered when designing secondary systems. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
Recent studies have indicated uncertainty about the performance limit states of seismically isolated buildings in very large earthquakes, especially if the isolator displacement demands exceed the seismic gap and induce pounding. Previous research has shown the benefit of providing phased supplemental damping that does not affect the isolation system response in a design event. A phased passive control device, or gap damper, was designed, fabricated, and experimentally evaluated during shake table testing of a quarter scale base‐isolated three‐story steel frame building. Identical input motions were applied to system configurations without a gap damper and with a gap damper, to directly assess the influence of the gap damper on displacement and acceleration demands. The gap damper was observed to reduce displacement demands by up to 15% relative to the isolated system without the gap damper. Superstructure floor accelerations increased substantially because of damper activation, but were limited to a peak of about 1.18 g. The gap damper reduces displacement most effectively if the ground motion contains one or more of the following characteristics: the spectral displacement increases with increasing period near the effective period of the isolation system, the motion is dominated by a single large pulse rather than multiple cycles at a consistent intensity, and the motion has a dominant component aligned with a major axis of the structure. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

7.
This paper evaluates the ability of simplified superstructure models, including two shear frame models and a single-story model, in predicting global responses of a full-scale five-story steel moment-frame buildings isolated by triple friction pendulum bearings subjected to earthquake motions. The investigated responses include displacement of the isolation system, roof drift, story drift, and floor acceleration. Mechanical properties of the simplified superstructure models were derived from the modal information of a verified full 3-D model. The comparison between the analytical responses and experimental responses shows that the simplified models can well predict the displacement of the isolation system. Furthermore, the shear-frame models are adequate for predicting floor acceleration when the specimen is subjected to horizontal ground motions. However, when the specimen is subjected to 3-D motions, the shear-frame models un-conservatively predict floor acceleration. The full 3-D model improves the prediction of story drift compared with the simplified models for both horizontal and 3-D motions.  相似文献   

8.
This paper proposes an online test technique that employs mixed control of displacement and force. Two types of mixed control, ‘displacement–force combined control’ and ‘displacement–force switching control’ are proposed. In displacement–force combined control, one jack is operated by displacement‐control, and another is operated by force‐control. Validity of the combined control technique is demonstrated by a series of online tests applied to a base‐isolated structure subjected to horizontal and vertical ground motions simultaneously. The substructuring technique is employed in the tests, and the base‐isolation layer is tested, with the rest of the structure modeled in the computer. Displacement‐control and force‐control were adopted for simulating the horizontal and vertical response, respectively. Both displacement‐ and force‐control were implemented successfully despite interference between the two jacks. Earthquake responses of the base‐isolated structure involving the effects of varying axial forces on the horizontal hysteretic behavior of the base‐isolation layer were simulated. In the displacement–force switching control, the jack was operated by displacement‐control when the test specimen was flexible but switched to force‐control once the specimen became stiff. Validity of the switching control technique was also checked by a series of online tests applied to the base‐isolated structure subjected to vertical ground motions. Switching between displacement‐control and force‐control was achieved when the axial force applied to the base‐isolation layer changed from tension to compression or from compression to tension. Both the displacement‐ and force‐control were successful even with many rounds of switching. The test revealed that large accelerations occurred on the floor immediately above the base‐isolation layer at the instants when the axial force of the base‐isolation layer changed from tension to compression. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

9.
To reduce floor acceleration of base‐isolated structures under earthquakes, a tuned mass damper (TMD) system installed on the roof is studied. The optimal tuning parameters of the TMD are analyzed for linear base isolation under a generalized ground motion, and the performance of the TMD is validated using a suite of recorded ground motions. The simulation shows that a TMD tuned to the second mode of a base‐isolated structure reduces roof acceleration more effectively than a TMD tuned to the first mode. The reduction ratio, defined as the maximum roof acceleration with the TMD relative to that without the TMD, is approximately 0.9 with the second‐mode TMD. The higher effectiveness of the second‐mode TMD relative to the first‐mode TMD is attributed primarily to the unique characteristics of base isolation, ie, the relatively long first‐mode period and high base damping. The modal acceleration of the second mode is close to or even higher than that of the first mode in base‐isolated structures. The larger TMD mass ratio and lower modal damping ratio of the second‐mode TMD compared to the first‐mode TMD increases its effect on modal acceleration reduction. The reduction ratio with the second‐mode TMD improves to 0.8 for bilinear base isolation. Because of the detuning effect caused by the change in the first‐mode period in bilinear isolation, the first‐mode TMD is ineffective in reducing roof acceleration. Additionally, the displacement experienced by the second‐mode TMD is considerably smaller than that of the first‐mode TMD, thereby reducing the installation space for the TMD.  相似文献   

10.
A new response spectrum method, which is named complex multiple-support response spectrum (CMSRS) method in this article, is developed for seismic analysis of non-classically damped linear system subjected to spatially varying multiple-supported ground motion. The CMSRS method is based on fundamental principles of random vibration theory and properly accounts for the effect of correlation between the support motions as well as between the modal displacement and velocity responses of structure, and provides an reasonable and acceptable estimate of the peak response in term of peak seismic ground motions and response spectra at the support points and the coherency function. Meanwhile, three new cross-correlation coefficients or cross covariance especially for the non-classically damped linear structures with multiple-supports excitations are derived under the same assumptions of the MSRS method of classically damped system. The CMSRS method is examined and compared to the results of time history analyses in two numerical examples of non-classically damped structures in consideration of the coherences of spatially variable ground motion. The results show that for non-classically damped structure, the cross terms representing the cross covariance between the pseudo-static and dynamic component are also quite small just as same as classically damped system. In addition, it is found that the usual way of neglecting all the off-diagonal elements in transformed damping matrix in modal coordinates in order to make the concerned non-classically damped structure to become remaining proportional damping property will bring some errors in the case of subjected to spatially excited inhomogeneous ground motion.  相似文献   

11.
The Rolling‐Ball Rubber‐Layer (RBRL) system was developed to enable seismic isolation of lightweight structures, such as special equipment or works of art, and is very versatile, a great range of equivalent natural frequencies and coefficients of damping being achievable through choice of the system parameters. The necessity to have a simple and effective design procedure has led to a new parametric experimentation at Tun Abdul Razak Research Centre (TARRC) on the rolling behaviour of the RBRL system and load–deflection behaviour of the recentering springs. The experimental results, together with theories for the rolling resistance of a loaded steel ball on a thin rubber layer and the lateral load–deflection behaviour of cylindrical rubber springs, are used to develop a general design method for the RBRL system, which allows the system to be tailored to the specific application. Sinusoidal test results are presented for the small‐deflection behaviour of the system, influenced by the presence of a viscoelastic depression on the rubber tracks beneath each ball, and an amplitude‐dependent time‐domain model is proposed, based on these results and on the steady‐state behaviour of the system. The model is validated through comparison with previously performed shaking‐table tests. Attention is here restricted to uniaxial behaviour. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
The step-by-step modal time history integration methods are developed for dynamic analysis of non-classically damped linear structures subjected to earthquake-induced ground motions. Both the mode displacement and mode acceleration-based algorithms are presented for the calculation of member and acceleration responses. The complex-valued eigenvectors are used to effect the modal decoupling of the equations of motion. However, the recursive step-by-step algorithms are still in terms of real quantities. The numerical results for the acceleration response and floor response spectra, obtained with these approaches, are presented. The mode acceleration approach is observed to be decidedly better than the mode displacement approach in as much as it alleviates the so-called missing mass effect, caused by the truncation of modes, very effectively. The utilization of the mode acceleration-based algorithms is, thus, recommended in all dynamic analyses for earthquake-induced ground motions.  相似文献   

13.
基于双线性和三线性的力-位移滞回线假设,导出了钢梁阻尼器隔震系统等效阻尼比与阻尼器延性率的关系;为了获得大阻尼比隔震系统,以尽量减小隔震系统的地震反应,求得了使系统阻尼比为最大的阻尼器相应延性率(即最佳延性率)所需满足的条件;给出了在给定地震地面运动输入条件下,使系统阻尼器变形位移达到最佳延性率的阻尼器初始刚度和屈服位移的确定方法。  相似文献   

14.
在近断层地震动下桥梁结构将发生较大反应,减隔震设计是减轻地震损伤的重要手段。提出了在桥梁双柱墩横桥向设置防屈曲支撑(BRB),在纵桥向设置铅芯橡胶支座(LRB)的双向减隔震体系。利用Midas Civil软件建立3种不同减隔震方式的桥梁结构模型:LRB仅单向,LRB双向与LRB联合BRB,运用非线性时程分析方法计算了桥墩反应(墩顶侧移角、残余位移角和曲率延性)、LRB支座变形和BRB的耗能特性等。结果表明:在近断层地震动输入下联合设置LRB和BRB的双向减隔震桥梁减震效果明显,相比其它2种方式,能有效降低墩柱的塑性变形及起到保护桥墩的作用。在横桥向,桥墩最大侧移角、残余位移角和最大曲率延性系数都显著降低。  相似文献   

15.
双向地震动作用的拟等延性系数谱   总被引:1,自引:0,他引:1  
首先建立了以强度折减系数表述的恢复力特性满足二维屈服面模型的理想弹塑性单质点系统(它在2个相互垂直的主轴方向上分别具有水平平动自由度)在双向地震动作用下的归一化运动方程。然后引入单向地震动作用下等延性系数的强度折减系数谱,给出了双向地震动作用的拟等延性系数谱(定义为系统分别承受双向和单向地震动作用,在同一主轴方向上的最大位移反应之比)最后通过硬土场地10组双向地震动记录拟等延性系数谱的统计平均结果,分析了结构周期、位移延性系数和阻尼等因素对谱值及结构双向地震反应的影响。结果表明,双向地震动作用与单向地震动作用相比主要增加结构较长周期方向的最大位移反应。若在基于位移的抗震设计中降低结构较短周期方向的设计位移延性系数,可在一定程度上降低双向地震动的不利影响。因定义的谱为比值形式,阻尼对其影响不大。  相似文献   

16.
The Friction Pendulum System (FPS) isolator is commonly used as a base isolation system in buildings. In this paper, a new tunable FPS (TFPS) isolator is proposed and developed to act as a semi‐active control system by combining the traditional FPS and semi‐active control concept. Theoretical analysis and physical tests were carried out to investigate the behavior of the proposed TFPS isolator. The experimental and theoretical results were in good agreement, both suggesting that the friction force of the TFPS isolator can be tuned to achieve seismic isolation of the structure. A series of numerical simulations of a base‐isolated structure equipped with the proposed TFPS isolator and subjected to earthquake ground motions were also conducted. In the analyses, the linear quadratic regulator (LQR) method was adopted to control the friction force of the proposed TFPS, and the applicability and effectiveness of the TFPS in controlling the structure's seismic responses were investigated. The simulation results showed that the TFPS can reduce the displacement of the isolation layer without significantly increasing the floor acceleration and inter‐story displacement of the superstructure, confirming that the TFPS can effectively control a base‐isolated structure under earthquake ground motions.  相似文献   

17.
In this paper the question of possible adverse effects of damping in seismic isolation because of higher mode response is investigated by means of simple models with a few degrees of freedom (DOF). In particular the second mode response of a 2 DOF system is examined in detail for both viscous and hysteretic (e.g. friction or elastoplastic) damping devices. Qualitative and approximate quantitative estimates are obtained by neglecting the influence of the modal coupling terms, due to viscous damping or friction forces, on the first mode response. It is shown that additional viscous damping has a diminishing effect on base displacement, storey shear force and floor spectra values in the vicinity of the first mode resonance. However, a significant amplification of the floor spectra values near the higher mode frequencies may occur. In accordance with the results of previous works, compared with the viscous damping case, hysteretic damping amplifies moderately the first storey shear force and significantly the upper storeys shear force. It also results, in a much more pronounced amplification of the floor spectral values than viscous damping, in the vicinity of the higher eigenfrequencies. However, the higher modes' response is milder if a realistic velocity dependence of the friction coefficient is taken into account. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

18.
为了研究铅芯橡胶隔震支座的阻尼分布对平扭耦联隔震体系隔震效果的影响,本文对一个三层两跨钢框架,通过调整上部结构负重块位置及下部铅芯橡胶隔震支座的分布位置,进行不同偏心工况下平扭耦联隔震体系地震模拟振动台试验,获得了不同偏心工况、不同阻尼分布情况下结构位移和加速度的时程曲线。试验和分析表明:隔震层阻尼中心与上部结构的质心位置接近,或者增大隔震层的阻尼半径,可显著地降低上部结构的扭转反应。  相似文献   

19.
A roller seismic isolation bearing is proposed for use in highway bridges. The bearing utilizes a rolling mechanism to achieve seismic isolation and has a zero post‐elastic stiffness under horizontal ground motions, a self‐centering capability, and unique friction devices for supplemental energy dissipation. The objectives of this research are to investigate the seismic behavior of the proposed bearing using parametric studies (1) with nonlinear response history analysis and (2) with equivalent linear analysis according to the AASHTO guide specifications, and by comparing the results from both analysis methods (3) to evaluate the accuracy of the AASHTO equivalent linear method for predicting the peak displacement of the proposed bearing during an earthquake. Twenty‐eight ground motions are used in the studies. The parameters examined are the sloping angle of the intermediate plate of the bearing, the amount of friction force for supplemental energy dissipation, and the peak ground acceleration levels of the ground motions. The peak displacement and base shear of the bearing are calculated. Results of the studies show that a larger sloping angle does not reduce the peak displacement for most of the parametric combinations without friction devices. However, for parametric combinations with friction devices, it allows for the use of a higher friction force, which effectively reduces the peak displacement, while keeping a self‐centering capability. The AASHTO equivalent linear method may underestimate the peak displacement by as much as 40%. Vertical ground motions have little effect on the peak displacement, but significantly increase the peak base shear. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
The effects of damping in various laminated rubber bearings (LRB) on the seismic response of a ?‐scale isolated test structure are investigated by shaking table tests and seismic response analyses. A series of shaking table tests of the structure were performed for a fixed base design and for a base isolation design. Two different types of LRB were used: natural rubber bearings (NRB) and lead rubber bearings (LLRB). Three different designs for the LLRB were tested; each design had a different diameter of lead plug, and thus, different damping values. Artificial time histories of peak ground acceleration 0.4g were used in both the tests and the analyses. In both shaking table tests and analyses, as expected, the acceleration responses of the seismically isolated test structure were considerably reduced. However, the shear displacement at the isolators was increased. To reduce the shear displacement in the isolators, the diameter of the lead plug in the LLRB had to be enlarged to increase isolator damping by more than 24%. This caused the isolator stiffness to increase, and resulted in amplifying the floor acceleration response spectra of the isolated test structure in the higher frequency ranges with a monotonic reduction of isolator shear displacement. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   