首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
This study focuses on the response of seismic isolated bridges subjected to near-field ground motions with distinct pulse type behavior in terms of maximum isolator displacements (MIDs) and maximum isolator forces (MIFs) transferred to the substructure. The employed isolation systems are composed of lead rubber bearings (LRBs) with bi-linear force-deformation relations that consider cycle-to-cycle deterioration in the yield strength of the LRBs due to heating of the lead core. MIDs and MIFs with due consideration of cycle-to-cycle deterioration are compared with that of non-deteriorating ones. Bounding analyses are also performed for comparison purposes. Nonlinear response history analyses are conducted with two bins of ground motions recorded at different soil conditions to investigate the effect of ground motion characteristics. Results indicate that MIDs are overestimated by lower bound analyses when seismic isolated bridges are subjected to near-field motions with high velocity pulses especially for the bearings with higher Q/W ratios.  相似文献   

2.
In this paper, the effect of lead core heating and associated strength deterioration on the seismic response of bridges isolated with lead rubber bearings (LRB) is investigated as a function of the characteristics of the isolator and near fault ground motions with forward rupture directivity effect. Furthermore, the ability of bounding analyses to provide a design envelope for maximum isolator force and maximum isolator displacement is verified. For this purpose, a series of nonlinear dynamic analyses are conducted for LRB isolated bridges where both deteriorating and non‐deteriorating force‐deformation relationship of LRB were employed. The analyses are performed for both simulated and recorded ground motions. It is found that while the temperature rise in the lead core generally increases with increasing magnitude and number of near fault ground motion velocity pulses, it decreases with larger distances from the fault. It is also found that bounding analysis method provides conservative (envelope) estimates of maximum isolator displacement and maximum isolator force for design purposes that fulfill its intended purpose. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
铅芯橡胶支座(lead-rubber bearing,LRB)是目前应用最为广泛的减隔震装置,普遍应用于建筑、桥梁、储罐和核电站等结构,其抗震性能已在屡次地震中得以验证。当LRB承受大幅值的往复变形时,其力学性能受内部铅芯发热的影响而发生显著变化,主要表现在滞回耗能、特征强度和刚度的降低等方面。首先,总结了铅芯橡胶支座及其结构在以往地震中的震害情况,介绍了预测LRB内部铅芯变形发热和温度升高的理论及近似求解方法,以及基于试验和有限元的验证方法及注意事项;其次,概述了LRB因内部铅芯变形发热导致其强度退化的分析模型和强度退化对结构地震反应的影响;最后,归纳了隔震结构在进行模型试验时,铅芯橡胶支座的相似理论和缩尺问题。  相似文献   

4.
在近断层地震动下桥梁结构将发生较大反应,减隔震设计是减轻地震损伤的重要手段。提出了在桥梁双柱墩横桥向设置防屈曲支撑(BRB),在纵桥向设置铅芯橡胶支座(LRB)的双向减隔震体系。利用Midas Civil软件建立3种不同减隔震方式的桥梁结构模型:LRB仅单向,LRB双向与LRB联合BRB,运用非线性时程分析方法计算了桥墩反应(墩顶侧移角、残余位移角和曲率延性)、LRB支座变形和BRB的耗能特性等。结果表明:在近断层地震动输入下联合设置LRB和BRB的双向减隔震桥梁减震效果明显,相比其它2种方式,能有效降低墩柱的塑性变形及起到保护桥墩的作用。在横桥向,桥墩最大侧移角、残余位移角和最大曲率延性系数都显著降低。  相似文献   

5.
The nuclear accident at Fukushima Daiichi in March 2011 has led the nuclear community to consider seismic isolation for new large light water and small modular reactors to withstand the effects of beyond design basis loadings, including extreme earthquakes. The United States Nuclear Regulatory Commission is sponsoring a research project that will quantify the response of low damping rubber (LDR) and lead rubber (LR) bearings under loadings associated with extreme earthquakes. Under design basis loadings, the response of an elastomeric bearing is not expected to deviate from well‐established numerical models, and bearings are not expected to experience net tension. However, under extended or beyond design basis shaking, elastomer shear strains may exceed 300% in regions of high seismic hazard, bearings may experience net tension, the compression and tension stiffness will be affected by isolator lateral displacement, and the properties of the lead core in LR bearings will degrade in the short‐term because of substantial energy dissipation. New mathematical models of LDR and LR bearings are presented for the analysis of base isolated structures under design and beyond design basis shaking, explicitly considering both the effects of lateral displacement and cyclic vertical and horizontal loading. These mathematical models extend the available formulations in shear and compression. Phenomenological models are presented to describe the behavior of elastomeric isolation bearings in tension, including the cavitation and post‐cavitation behavior. The elastic mechanical properties make use of the two‐spring model. Strength degradation of LR bearing under cyclic shear loading due to heating of lead core is incorporated. The bilinear area reduction method is used to include variation of critical buckling load capacity with lateral displacement. The numerical models are coded in OpenSees, and the results of numerical analysis are compared with test data. The effect of different parameters on the response is investigated through a series of analyses. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
Simplified methods of analysis described in codes and specifications for seismically isolated structures are always used either directly in special cases or for checking the results of nonlinear response history analysis (RHA). In this study, the maximum isolator displacements and base shears determined by nonlinear RHA are compared with those determined by the equivalent lateral force (ELF) procedure in order to assess the accuracy of the simplified method in the case of earthquakes with near field characteristics. Features of this study are that the ground motions used in analysis are selected and scaled using contemporary concepts and that the ground excitation is considered bi-directional. It is shown that the simplified method provides acceptably accurate predictions of shear isolator displacements and shear forces for a range of isolator properties and ground motions representative of stiff and soft soil conditions.  相似文献   

7.
A procedure for developing equations that estimate the isolator displacement due to strong ground motion is applied to buildings isolated with the friction pendulum system. The resulting design equations, based on rigorous non‐linear analysis, offer an alternative to the iterative equivalent‐linear methods used by current U.S. building codes. The governing equations of the system are reduced to a form such that the median normalized displacement of the system due to an ensemble of ground motions is found to depend on only the isolation period—a function of the curvature of the isolator—and the friction force at incipient slip normalized by peak ground velocity. The normalization is effective in minimizing the dispersion of the normalized displacement for an ensemble of ground motions, implying that the median normalized displacement is a reliable estimate of response. The design equations reflect the significant (20 to 38%) increase in displacement when the excitation includes two lateral components of ground motion instead of just one component. Equivalent‐linear methods are shown to underestimate by up to 30% the exact median displacement determined by non‐linear response history analysis for one component of ground motion, and building codes include at most a 4.4% increase for a second component. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

8.
以HDR隔震梁桥多自由度(MDOF)模型和等效双线性单自由度(SDOF)模型为研究对象,以典型近场地震动作为输入,研究HDR支座双向耦合效应对HDR隔震梁桥地震响应的影响。研究结果表明:不考虑双向耦合效应的HDR支座滞回曲线呈典型双线性;考虑双向耦合效应的HDR支座滞回曲线面积小于不考虑双向耦合效应的HDR支座滞回曲线面积。不考虑双向耦合效应的顺桥向HDR支座位移峰值db大于考虑双向耦合效应时,但横桥向的结果相反。近场地震作用下,对梁桥进行HDR支座隔震设计时,忽略双向耦合效应计算得到的墩底剪力峰值和弯矩峰值均偏于保守。可忽略HDR支座双向耦合效应对HDR隔震梁桥近场地震能量的影响。  相似文献   

9.
The Friction Pendulum System (FPS) isolator is commonly used as a base isolation system in buildings. In this paper, a new tunable FPS (TFPS) isolator is proposed and developed to act as a semi‐active control system by combining the traditional FPS and semi‐active control concept. Theoretical analysis and physical tests were carried out to investigate the behavior of the proposed TFPS isolator. The experimental and theoretical results were in good agreement, both suggesting that the friction force of the TFPS isolator can be tuned to achieve seismic isolation of the structure. A series of numerical simulations of a base‐isolated structure equipped with the proposed TFPS isolator and subjected to earthquake ground motions were also conducted. In the analyses, the linear quadratic regulator (LQR) method was adopted to control the friction force of the proposed TFPS, and the applicability and effectiveness of the TFPS in controlling the structure's seismic responses were investigated. The simulation results showed that the TFPS can reduce the displacement of the isolation layer without significantly increasing the floor acceleration and inter‐story displacement of the superstructure, confirming that the TFPS can effectively control a base‐isolated structure under earthquake ground motions.  相似文献   

10.
Seismic pounding of base‐isolated buildings has been mostly studied in the past assuming unidirectional excitation. Therefore, in this study, the effects of seismic pounding on the response of base‐isolated reinforced concrete buildings under bidirectional excitation are investigated. For this purpose, a three‐dimensional finite element model of a code‐compliant four‐story building is considered, where a newly developed contact element that accounts for friction and is capable of simulating pounding with retaining walls at the base, is used. Nonlinear behavior of the superstructure as well as the isolation system is considered. The performance of the building is evaluated separately for far‐fault non‐pulse‐like ground motions and near‐fault pulse‐like ground motions, which are weighted scaled to represent two levels of shaking viz. the design earthquake (DE) level and the risk‐targeted maximum considered earthquake (MCER) level. Nonlinear time‐history analyses are carried out considering lower bound as well as upper bound properties of isolators. The influence of separation distance between the building and the retaining walls at the base is also investigated. It is found that if pounding is avoided, the performance of the building is satisfactory in terms of limiting structural and nonstructural damage, under DE‐level motions and MCER‐level far‐fault motions, whereas unacceptably large demands are imposed by MCER‐level near‐fault motions. In the case of seismic pounding, MCER‐level near‐fault motions are found to be detrimental, where the effect of pounding is mostly concentrated at the first story. In addition, it is determined that considering unidirectional excitation instead of bidirectional excitation for MCER‐level near‐fault motions provides highly unconservative estimates of superstructure demands. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
We present a vertical vibration isolator having a piecewise‐constant restoring force, which belongs to a class of passive and nonlinear vibration isolators. In vertical vibration isolation, direct use of low‐stiffness elements leads to unacceptably large deformations due to self‐weight. To overcome the difficulty, we apply a combination of constant‐force springs, each of which sustains a constant load regardless of its stretch. By arranging the constant‐force springs, so that the isolator has a piecewise‐constant restoring force, we alleviate the problem of the excessive deformation caused by self‐weight, provide stability at the static equilibrium state along with the self‐centering capability, and realize a large stroke while keeping the mechanism simple and compact. Further, we attempt to limit the response acceleration within a tolerance regardless of the frequency spectrum and the magnitude of earthquake ground motions. We demonstrate the effectiveness of the present isolator through shaking table tests and numerical simulations. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
A comprehensive approach is developed to estimate relevant design quantities—lateral deformations and axial forces—in isolation systems composed of lead–rubber bearings. The approach, applicable to symmetric and asymmetric‐plan systems, includes the effects of bidirectional excitation, rocking, and torsion; and is the culmination of previous work on this topic. The approach is based on nonlinear response history analysis of an isolated block using an advanced bearing model that incorporates the interaction between axial force and lateral response of the bearing, known as axial‐load effects. The rocking response of the system and peak axial forces are shown to depend on the isolation period, the normalized strength—or yield strength normalized by peak ground velocity, the ratios of rocking frequency about each horizontal axis to vertical frequency, and the normalized stiffness eccentricity. In an attempt to develop results widely applicable to asymmetric‐plan systems, eccentricity is introduced by varying the stiffnesses and strengths of individual bearings in an idealized, rectangular plan. This idealized system approach is shown to have limited success; when applied to actual asymmetric‐plan systems the design equations to estimate response are accurate for lateral deformations but err by up to 25% for axial forces. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

13.
This paper presents a passive vertical quasi‐zero‐stiffness vibration isolator intended for relatively small objects. The present isolator has features of compactness, long stroke, and adjustability to various load capabilities. To realize these features, we use constant‐force springs, which sustain constant load regardless of their elongation, and propose a variable ellipse curve mechanism that is inspired by the principle of ellipsographs. The variable ellipse curve mechanism can convert the restoring force of the horizontally placed constant‐force springs to the vertical restoring force of the vibration isolator. At the same time as converting the direction, the vertical restoring force can be adjusted by changing the ratio of the semi‐minor axis to the semi‐major one of the ellipse. In this study, a prototype of a class of quasi‐zero‐stiffness vibration isolator with the proposed variable ellipse curve mechanism is created. Shaking table tests are performed to demonstrate the efficacy of the present mechanism, where the prototype is subjected to various sinusoidal and earthquake ground motions. It is demonstrated through the shaking table tests that the prototype can reduce the response acceleration within the same specified tolerance even when the mass of the vibration isolated object is changed. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

14.
This paper reports on an investigation of the seismic response of base-isolated reinforced concrete buildings, which considers various isolation system parameters under bidirectional near-fault and far-fault motions. Three-dimensional models of 4-, 8-, and 12-story base-isolated buildings with nonlinear effects in the isolation system and the superstructure are investigated, and nonlinear response history analysis is carried out. The bounding values of isolation system properties that incorporate the aging effect of isolators are also taken into account, as is the current state of practice in the design and analysis of base-isolated buildings. The response indicators of the buildings are studied for near-fault and far-fault motions weight-scaled to represent the design earthquake (DE) level and the risk-targeted maximum considered earthquake (MCER) level. Results of the nonlinear response history analyses indicate no structural damage under DE-level motions for near-fault and far-fault motions and for MCER-level far-fault motions, whereas minor structural damage is observed under MCER-level near-fault motions. Results of the base-isolated buildings are compared with their fixed-base counterparts. Significant reduction of the superstructure response of the 12-story base-isolated building compared to the fixed-base condition indicates that base isolation can be effectively used in taller buildings to enhance performance. Additionally, the applicability of a rigid superstructure to predict the isolator displacement demand is also investigated. It is found that the isolator displacements can be estimated accurately using a rigid body model for the superstructure for the buildings considered.  相似文献   

15.
Structural impact between adjacent buildings may induce local and, in some extreme cases, severe damage, especially in the case of seismically isolated buildings. This study parametrically investigates in the three‐dimensional domain the effect of pounding on the peak response of base‐isolated buildings, which are simulated as nonlinear three‐dimensional multi‐degree‐of‐freedom systems. Firstly, it is shown that considering unidirectional, instead of bidirectional, excitations may lead to underestimation of the base drift demands. Subsequently, the peak responses of seismically isolated buildings utilizing lead rubber bearings are studied while varying important parameters, such as the incidence angle of seismic excitations, the available seismic clearance, and mass eccentricities, under the action of bidirectional horizontal excitations. A large number of numerical simulations are performed using a specially developed software that implements an efficient approach to model impacts, taking into account arbitrary locations of contact points. It is found that the peak interstory drift ratio is significantly influenced by the directionality of the ground motion. Therefore, the seismic performance of structures should ideally be assessed examining the peak structural response while bidirectional ground motions are imposed at various incident angles. Furthermore, it is also observed that the interstory drift ratios increase while decreasing the available gap size, up to a certain value. Finally, the parametric analyses indicate that the effects of impact are more severe for structures with mass eccentricities, and in which case, the estimation of the critical incidence angle becomes more laborious. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

16.
方形多铅芯橡胶支座力学性能研究   总被引:7,自引:0,他引:7  
本文通过对方形多铅芯橡胶支座竖向压缩性能试验,水平剪切性能试验以及其等效刚度、屈服强度、屈服后刚度、等效阻尼比等水平特征参数与水平剪切应变和竖向压应力的关系,特别是对其在不同方向上压缩剪切变形状态下的性能试验,分析了这种隔震支座各种水平特征参数在不同方向上变化的相关规律。得出在这种类型橡胶隔震支座在双向水平荷载同时作用下,竖向性能和水平性能较为稳定,是较为理想的桥梁结构的减隔震装置。  相似文献   

17.
With the launch of the high‐speed train project in California, the seismic risk is a crucial concern to the stakeholders. To investigate the seismic behavior of future California High‐Speed Rail (CHSR) bridge structures, a 3D nonlinear finite‐element model of a CHSR prototype bridge is developed. Soil‐structure and track‐structure interactions are accounted for in this comprehensive numerical model used to simulate the seismic response of the bridge and track system. This paper focuses on examining potential benefits and possible drawbacks of the a priori promising application of seismic isolation in CHSR bridges. Nonlinear time history analyses are performed for this prototype bridge subjected to two bidirectional horizontal historical earthquake ground motions each scaled to two different seismic hazard levels. The effect of seismic isolation on the seismic performance of the bridge is investigated through a detailed comparison of the seismic response of the bridge with and without seismic isolation. It is found that seismic isolation significantly reduces the deck acceleration and the force demand in the bridge substructure (i.e., piers and foundations), especially for high‐intensity earthquakes. However, seismic isolation increases the deck displacement (relative to the pile cap) and the stresses in the rails. These findings imply that seismic isolation can be promisingly applied to CHSR bridges with due consideration of balancing its beneficial and detrimental effects through using appropriate isolators design. The optimum seismic isolator properties can be sought by solving a performance‐based optimum seismic design problem using the nonlinear finite‐element model presented herein. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

18.
This paper investigates numerically the seismic response of six seismically base‐isolated (BI) 20‐story reinforced concrete buildings and compares their response to that of a fixed‐base (FB) building with a similar structural system above ground. Located in Berkeley, California, 2 km from the Hayward fault, the buildings are designed with a core wall that provides most of the lateral force resistance above ground. For the BI buildings, the following are investigated: two isolation systems (both implemented below a three‐story basement), isolation periods equal to 4, 5, and 6 s, and two levels of flexural strength of the wall. The first isolation system combines tension‐resistant friction pendulum bearings and nonlinear fluid viscous dampers (NFVDs); the second combines low‐friction tension‐resistant crosslinear bearings, lead‐rubber bearings, and NFVDs. The designs of all buildings satisfy ASCE 7‐10 requirements, except that one component of horizontal excitation, is used in the 2D nonlinear response history analysis. Analysis is performed for a set of ground motions scaled to the design earthquake and to the maximum considered earthquake (MCE). At both the design earthquake and the MCE, the FB building develops large inelastic deformations and shear forces in the wall and large floor accelerations. At the MCE, four of the BI buildings experience nominally elastic response of the wall, with floor accelerations and shear forces being 0.25 to 0.55 times those experienced by the FB building. The response of the FB and four of the BI buildings to four unscaled historical pulse‐like near‐fault ground motions is also studied. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
Results of an analytical study aimed at evaluating residual displacement ratios, Cr, which allow the estimation of residual displacement demands from maximum elastic displacement demands is presented. Residual displacement ratios were computed using response time‐history analyses of single‐degree‐of‐freedom systems having 6 levels of relative lateral strength when subjected to an ensemble of 240 earthquake ground motions recorded in stations placed on firm sites. The results were statistically organized to evaluate the influence of the following parameters: period of vibration, level of relative lateral strength, site conditions, earthquake magnitude, and distance to the source. In addition, the influence of post‐yield stiffness ratio in bilinear systems and of the unloading stiffness in stiffness‐degrading systems was also investigated. A special emphasis is given to the uncertainty of these ratios. From this study, it is concluded that mean residual displacement ratios are more sensitive to changes in local site conditions, earthquake magnitude, distance to the source range and hysteretic behaviour than mean inelastic displacement ratios. In particular, residual displacement ratios exhibit large levels of record‐to‐record variability and, therefore, this dispersion should be taken into account when estimating residual displacements. A simplified expression is presented to estimate mean residual displacements ratios for elastoplastic systems during the evaluation of existing structures built on firm soil sites. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

20.
In this study, closed form equations as functions of the isolator, bridge and ground motion properties are formulated to calculate the optimum characteristic strength, Qd and post-elastic stiffness, kd, of the isolator to minimize the maximum isolator displacement (MID) and force (MIF) for seismic isolated bridges (SIBs). For this purpose, first, sensitivity analyses are conducted to identify the bridge, isolator and ground motion parameters that affect the optimum values of Qd and kd. Next, for the identified parameters, nonlinear time history analyses of typical SIBs are conducted to determine the optimum values of Qd and kd for a wide range of values of the parameters. Next, nonlinear regression analyses of the available data are conducted to obtain closed form equations for the optimum values of Qd and kd, to minimize the MID and MIF. The equations are then simplified for various site soil conditions. It is observed that the optimum Qd and kd are highly dependent on the site soil condition. Furthermore, the optimum Qd is found to be a linear function of the peak ground acceleration.  相似文献   