1.
Performance-Based Seismic Design is now widely recognized as the pre-eminent seismic design and assessment methodology for building structures. In recognition of this, seismic codes may require that buildings achieve multiple performance objectives such as withstanding moderate, yet frequently occurring earthquakes with minimal structural and non-structural damage, while withstanding severe, but rare earthquakes without collapse and loss of life. These objectives are presumed to be satisfied by some codes if the force-based design procedures are followed. This paper investigates the efficacy of the Eurocode 8 force-based design provisions with respect to RC frame building design and expected seismic performance. Four, eight, and 16-storey moment frame buildings were designed and analyzed using the code modal response spectrum analysis provisions. Non-linear time-history analyses were subsequently performed to determine the simulated seismic response of the structures and to validate the Eurocode 8 force-based designs. The results indicate the design of flexural members in medium-to-long period structures is not significantly influenced by the choice of effective member stiffness; however, calculated interstorey drift demands are significantly affected. This finding was primarily attributed to the code’s enforcement of a minimum spectral ordinate on the design spectrum. Furthermore, design storey forces and interstorey drift demand estimates (and therefore damage), obtained by application of the code force-based design procedure varied substantially from those found through non-linear time-history analysis. Overall, the results suggest that though the Eurocode 8 may yield life-safe designs, the seismic performance of frame buildings of the same type and ductility class can be highly non-uniform.  相似文献   

2.
耗能梁段作为偏心支撑结构的耗能元件,在大震作用下通过弹塑性变形吸收地震能量,保护主体结构处于弹性受力状态。现行规范基于强度的设计理论,为了保证耗能梁段进入塑性或破坏,梁柱构件需要进行放大内力设计,导致截面过大,而且基于强度的设计方法很难保证结构的整体破坏状态。目前,抗震设计越来越重视基于性能的设计思想,该方法能够评估结构的弹塑性反应。对于高强钢组合偏心支撑,其中耗能梁段和支撑采用Q345钢,框架梁柱采用Q460或者Q690高强度钢材,高强钢不仅带来良好的经济效益,而且能够推广高强钢在抗震设防区的应用。利用基于性能设计方法设计了4种不同形式的高强钢组合偏心支撑钢框架,包括K形、Y形、V形和D形,考虑4层、8层、12层和16层的影响。通过Pushover分析和非线性时程分析评估该结构的抗震性能,研究结果表明:4种形式的高强钢组合偏心支撑钢框架具有类似的抗震性能,在罕遇地震作用下,几乎所有耗能梁段均参与耗能,而且层间侧移与耗能梁段转角沿高度分布较为均匀。其中:D形偏心支撑具有最大的抗侧刚度,但延性较差,而Y形偏心支撑的抗侧刚度最弱,但延性最佳。  相似文献   

3.
A method is presented to quantify the inelastic seismic resistance of reinforced concrete stack-like structures by non-linear earthquake analysis. The deformed configuration of stack is idealized as an assemblage of beam elements and actual stress–strain relationships of concrete and reinforcing steel are used to evaluate element matrices. Repeated non-linear analyses are performed by gradually increasing the intensity of acceleration time histories to a level where collapse of the stack is observed in primary stresses. The set of time histories thus obtained are then used to define the ultimate intensity of ground motion that the stack can sustain if inelastic deformations are permitted. A procedure is presented to quantify the difference between inelastic seismic resistance and elastic seismic resistance in terms of displacement ductility capacity factors. For seismic design using available inelastic resistance, values of curvature ductility factor demand for the cross-sections of stacks are also presented. © 1997 by John Wiley & Sons, Ltd.  相似文献   

4.
为研究核心筒抗震性能水准及其指标限值,完成了3个核心筒拟静力试验,记录了损伤过程及对应的层间位移角。在现有核心筒研究成果及国内外规范的基础上,将核心筒的抗震性能水准划分为4个等级,并给出了相应的宏观描述。通过总结相关试验研究结果,发现《建筑抗震设计规范》(GB50011-2010)对层间位移角限制过于严格,考虑到结构带裂缝工作,层间位移角限制过严会增加建筑成本,并导致结构自重增加而不利于抗震,故建议适当放宽核心筒的层间位移角限值,分别给出框架-核心筒及筒中筒结构最大层间位移角建议值。  相似文献   

5.
This paper presents a procedure for seismic design of reinforced concrete structures, in which performance objectives are formulated in terms of maximum accepted mean annual frequency (MAF) of exceedance, for multiple limit states. The procedure is explicitly probabilistic and uses Cornell's like closed‐form equations for the MAFs. A gradient‐based constrained optimization technique is used for obtaining values of structural design variables (members' section size and reinforcement) satisfying multiple objectives in terms of risk levels. The method is practically feasible even for real‐sized structures thanks to the adoption of adaptive equivalent linear models where element‐by‐element stiffness reduction is performed (2 linear analyses per intensity level). General geometric and capacity design constraints are duly accounted for. The procedure is applied to a 15‐storey plane frame building, and validation is conducted against results in terms of drift profiles and MAF of exceedance, obtained by multiple‐stripe analysis with records selected to match conditional spectra. Results show that the method is suitable for performance‐based seismic design of RC structures with explicit targets in terms of desired risk levels.  相似文献   

6.
剪切型结构的抗震强度折减系数研究   总被引:1,自引:0,他引:1  
为了研究剪切型结构抗震强度需求的变化规律,本文基于单自由度体系的非线性时程分析,研究了不同场地条件下延性折减系数与位移延性系数和结构自振周期的关系;采用修正等效单自由度体系位移延性折减系数的方法,研究了剪切型多自由度体系的延性折减系数;以基于中国建筑抗震规范设计的代表不同抗震能力要求的RC框架结构为分析对象,通过静力弹塑性分析,研究了RC框架结构的体系超强能力。分析结果表明场地类别、位移延性水准和结构振动周期对单自由度体系的延性折减系数有显著的影响;多自由度体系的抗震延性折减系数明显比其相应的等效单自由度体系的抗震延性折减系数小;RC框架结构的超强系数一般随结构楼层数的增加而减小,随抗震设防烈度的增大而减小,内框架的超强系数比边框架的超强系数大。  相似文献   

7.
混凝土小砌块约束砌体结构,由于加入芯柱、构造柱、圈梁,使结构整体性提高,因此具有较好的抗震性能和发展前景。通过整理94个混凝土小砌块约束砌体墙片试验数据,考虑权重,统计了混凝土小砌块约束砌体墙片延性系数,给出了延性系数与高度、延性系数比与高宽的关系,同时给出了层间开裂位移角、层间极限位移角公式,以及接近倒塌时混凝土小砌块约束砌体结构层间位移的计算公式,并与一个八层混凝土小砌块约束砌体结构的动力时程分析结果进行了对比,结果显示,最大误差在顶层,为17.7%,因此,所提层间位移计算公式是可以满足工程精度需要的,为混凝土小砌块约束砌体结构基于性态的抗震分析提供参考。  相似文献   

8.
非线性黏滞阻尼减震结构基于位移的设计方法   总被引:1,自引:0,他引:1  
结合我国抗震设计规范,提出非线性黏滞阻尼减震结构基于位移的设计方法.根据减震结构的特点,将其性能划分为使用良好、人身安全和防止倒塌3个水平,并用层间位移角限值予以量化;以简化的方法计算非线性黏滞阻尼器的等效阻尼比.在此基础上将结构转化为等效单自由度体系,利用基于位移的设计方法对非线性黏滞阻尼减震结构进行设计,通过算例,介绍用该方法对框架结构进行非线性黏滞阻尼减震设计的设计过程.实例分析表明,提出的非线性黏滞阻尼减震结构基于位移的设计方法是可行的,并且与时程分析得出的平均结果吻合较好,而且该方法简单实用,便于操作,能够控制减震结构在不同强度水准地震作用下的性能.  相似文献   

9.
Post-earthquake surveys indicate that losses come from non-structural damage more than from structural damage. Current performance-based design would prevent excessive non-structural damage as well, but the effectiveness of relevant code provisions has not been assessed in depth. This study investigates the drift-sensitive non-structural damage to reinforced concrete frame buildings complying with the European seismic code. Damage to non-structural unreinforced masonry infill walls in contact with the frame is quantified in terms of numerical fragility curves with the same quantities considered in the design: the peak ground acceleration measures the seismic intensity; the peak value of the interstorey drift ratio is the damage index. The methodology for the fragility computation is described in detail. Peculiar is the use of probabilistic parameters of the drift capacity coupled to the fuzziness in the damage state. The drift demand is estimated by member-by-member modelling of typical frame structures and non-linear time–history analyses under spectrum-compatible artificial accelerograms. The kind of the infills and their modelling, the number of storeys, the ground type, and the ductility class are covered. Modelling the infills results to be essential. Any code-compliant verification is on the safe side, but the margin appears to be inconsistent among the frames under consideration. Furthermore, there is one case where occupancy appears to be not ensured despite the code verification is satisfied. The effect of the number of storeys may be misrepresented. The ductility class may be unimportant, however the damage seems to be correlated with the likely strength.  相似文献   

10.
An Erratum has been published for this article in Earthquake Engineering and Structural Dynamics 2003; 32:1795. The recently developed modal pushover analysis (MPA) has been shown to be a significant improvement over the pushover analysis procedures currently used in structural engineering practice. None of the current invariant force distributions accounts for the contribution of higher modes—higher than the fundamental mode—to the response or for redistribution of inertial forces because of structural yielding. By including the contributions of a sufficient number of modes of vibration (generally two to three), the height‐wise distribution of responses estimated by MPA is generally similar to the ‘exact’ results from non‐linear response history analysis (RHA). Although the results of the previous research were extremely promising, only a few buildings were evaluated. The results presented below evaluate the accuracy of MPA for a wide range of buildings and ground motion ensembles. The selected structures are idealized frames of six different heights: 3, 6, 9, 12, 15, and 18 stories and five strength levels corresponding to SDF‐system ductility factor of 1, 1.5, 2, 4, and 6; each frame is analysed for 20 ground motions. Comparing the median values of storey‐drift demands determined by MPA to those obtained from non‐linear RHA shows that the MPA predicts reasonably well the changing height‐wise variation of demand with building height and SDF‐system ductility factor. Median and dispersion values of the ratios of storey‐drift demands determined by MPA and non‐linear‐RHA procedures were computed to measure the bias and dispersion of MPA estimates with the following results: (1) the bias and dispersion in the MPA procedure tend to increase for longer‐period frames and larger SDF‐system ductility factors (although these trends are not perfect); (2) the bias and dispersion in MPA estimates of seismic demands for inelastic frames are usually larger than for elastic systems; (3) the well‐known response spectrum analysis (RSA), which is equivalent to the MPA for elastic systems, consistently underestimates the response of elastic structures, e.g. up to 18% in the upper‐storey drifts of 18‐storey frames. Finally, the MPA procedure is simplified to facilitate its implementation in engineering practice—where the earthquake hazard is usually defined in terms of a median (or some other percentile) design spectrum for elastic systems—and the accuracy of this simplified procedure is documented. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

11.
Post‐tensioned (PT) self‐centering moment‐resisting frames (MRFs) have recently been developed as an alternative to welded moment frames. The first generation of these systems incorporated yielding energy dissipation mechanisms, whereas more recently, PT self‐centering friction damped (SCFR) moment‐resistant connections have been proposed and experimentally validated. Although all of these systems exhibited good stiffness, strength and ductility properties and stable dissipation of energy under cyclic loading, questions concerning their ultimate response still remained and a complete design methodology to allow engineers to conceive structures using these systems was also needed. In this paper, the mechanics of SCFR frames are first described and a comprehensive design procedure that accounts for the frame behavior and the nonlinear dynamics of self‐centering frames is then elaborated. A strategy for the response of these systems at ultimate deformation stages is then proposed and detailing requirements on the beams in order to achieve this response are outlined. The proposed procedure aims to achieve designs where the interstory drifts for SCFR frames are similar to those of special steel welded moment‐resisting frames (WMRFs). Furthermore, this procedure is adapted from current seismic design practices and can be extended to any other PT self‐centering steel frame system. A six‐story building incorporating WMRFs was designed and a similar building incorporating SCFR frames were re‐designed by the proposed seismic design procedure. Time‐history analyses showed that the maximum interstory drifts and maximum floor accelerations of the SCFR frame were similar to those of the WMRF but that almost zero residual drifts were observed for the SCFR frame. The results obtained from the analyses confirmed the validity of the proposed seismic design procedure, since the peak drift values were similar to those prescribed by the seismic design codes and the SCFR frames achieved the intended performance level under both design and maximum considerable levels of seismic loading. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
Equivalent viscous damping for steel concentrically braced frame structures   总被引:1,自引:1,他引:0  
The direct displacement based seismic design procedure utilises equivalent viscous damping expressions to represent the effect of energy dissipation of a structural system. Various expressions for the equivalent viscous damping of different structural systems are available in the literature, but the structural systems examined in the past have not included concentrically braced frame structures. Thus, this study describes the development of an equivalent viscous damping equation for concentrically braced frame structures based on the hysteretic response of 15 different single storey models. Initially, equivalent viscous damping is calculated based on the area based approach and then corrected for the earthquake excitation. An iterative procedure is adopted to calibrate the equivalent viscous damping expression to the results of inelastic time history analyses using a number of spectrum-compatible real accelerograms. From the results of this research, a new damping expression is developed as a function of the ductility and the non dimensional slenderness ratio.  相似文献   

13.
当前国家对建筑结构的抗震性能和震后功能恢复能力提出了更高要求。基于短剪切型消能梁段的受剪屈服特性和剪切扩孔型螺栓连接的受剪滑移性能,提出一种新型扩孔螺栓连接型消能梁段,可有效增大消能梁段的延性和耗能能力并同时减小消能梁段的损伤,使带扩孔螺栓连接型消能梁段的新型Y形偏心支撑结构更好地适应当前要求。采用有限元方法详细分析扩孔螺栓连接型消能梁段的滞回性能、破坏模式和耗能机理,由此得到其骨架曲线和力学模型,并阐述其力学模型的影响参数,为相应偏心支撑结构的设计和分析提供理论依据。  相似文献   

14.
The response of multi‐storey structures can be controlled under earthquake actions by installing seismic isolators at various storey levels. By vertically distributing isolation devices at various elevations, the designer is provided with numerous options to appropriately adjust the seismic performance of a building. However, introducing seismic isolators at various storey levels is not a straightforward task, as it may lead to favourable or unfavourable structural behaviour depending on a large number of factors. As a consequence, a rather chaotic decision space of seismic isolation configurations arises, within which a favourable solution needs to be located. The search for favourable isolators' configurations is formulated in this work as a single‐objective optimization task. The aim of the optimization process is to minimize the maximum floor acceleration of the building under consideration, while constraints are specified to control the maximum interstorey drift, the maximum base displacement and the total seismic isolation cost. A genetic algorithm is implemented to perform this optimization task, which selectively introduces seismic isolators at various elevations, in order to identify the optimal configuration for the isolators satisfying the pre‐specified constraints. This way, optimized earthquake response of multi‐storey buildings can be obtained. The effectiveness of the proposed optimization procedure in the design of a seismically isolated structure is demonstrated in a numerical study using time‐history analyses of a typical six‐storey building. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
This paper investigates the non-linear seismic behavior of structures such as slender unreinforced masonry shear walls or precast post-tensioned reinforced concrete elements, which have little hysteretic energy dissipation capacity. Even if this type of seismic response may be associated with significant deformation capacity, it is usually not considered as an efficient mechanism to withstand strong earthquakes. The objective of the investigations is to propose values of strength reduction factors for seismic analysis of such structures. The first part of the study is focused on non-linear single-degree-of-freedom (SDOF) systems. A parametric study is performed by computing the displacement ductility demand of non-linear SDOF systems for a set of 164 recorded ground motions selected from the European Strong Motion Database. The parameters investigated are the natural frequency, the strength reduction factor, the post-yield stiffness ratio, the hysteretic energy dissipation capacity and the hysteretic behavior model (four different hysteretic models: bilinear self-centring, with limited or without energy dissipation capacity, modified Takeda and Elastoplastic). Results confirm that the natural frequency has little influence on the displacement ductility demand if it is below a frequency limit and vice versa. The frequency limit is found to be around 2 Hz for all hysteretic models. Moreover, they show that the other parameters, especially the hysteretic behavior model, have little influence on the displacement ductility demand. New relationships between the displacement ductility demand and the strength reduction factor for structures having little hysteretic energy dissipation capacity are proposed. These relationships are an improvement of the equal displacement rule for the considered hysteretic models. In the second part of the investigation, the parametric study is extended to multi-degree-of-freedom (MDOF) systems. The investigation shows that the results obtained for SDOF systems are also valid for MDOF systems. However, the SDOF system overestimates the displacement ductility demand in comparison to the corresponding MDOF system by approximately 15%.  相似文献   

16.
A process is outlined and evaluated for the estimation of seismic roof and storey drift demands for frame structures from the spectral displacement demand at the first mode period of the structure. The spectral displacement demand is related to the roof drift demand for the multi‐degree‐of‐freedom (MDOF) structure using three modification factors, accounting for MDOF effects, inelasticity effects, and P‐delta effects. Median values and measures of dispersion for the factors are obtained from elastic and inelastic time history analyses of nine steel moment resisting frame structures subjected to sets of ground motions representative of different hazard levels. The roof drift demand is related to the storey drift demands, with the results being strongly dependent on the number of stories and the ground motion characteristics. The relationships proposed in this paper should prove useful in the conceptual design phase, in estimating deformation demands for performance assessment, and in improving basic understanding of seismic behaviour. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

17.
Inelastic deformations of structures subjected to strong earthquakes are commonly accepted by Aseismic Codes; some discrepancies exist in the different procedures proposed to design a structure for which the ductility demand is to be limited within acceptable values. To have a better insight into the seismic behaviour of multi-degree-of-freedom structures beyond the elastic range, the dynamic elasto-plastic response of a ten-storey shear system under two sets of artificial and recorded accelerograms is studied considering different stiffness-strength distributions and constitutive laws. Statistics of the results are presented, demonstrating the dependence of the overall and storey ductility values and of their ratio on the characteristics of the structure and excitation.  相似文献   

18.
Among the resisting systems suitable for the design of ductile steel structures, Eurocode 8 proposes MRFs and EBFs. The formers are considered more efficient in terms of ductility, but they suffer a strong weakness in the lateral stiffness, with following cumbersome design procedures to avoid excessive lateral displacements maintaining a quite high ductile behaviour under seismic actions. Often, the design process leads to not optimized structural members, oversized with respect to the minimum seismic requirements due to lateral deformation limitations. EBFs combine high lateral stiffness, due to bracing elements, and high dissipative capacities, provided by the plastic hinges developed in links. Eurocode 8 proposes a design procedure for EBF structures in which iterative checks are required to design links with a defined level resistance dependent on all the other links’ strength. The present paper investigates the seismic behaviour of EBFs using Incremental Dynamic Analyses (IDA) to explore their mechanical response under increasing seismic action. IDAs are executed considering the influence of variability of steel mechanical properties on the behaviour of EBFs, using seven artificial accelerograms according to Eurocode 8. The aims of IDAs are the probabilistic assessment of the response of the system with respect to the variability of the material properties, the analysis of structural safety and the ability of the structures to internally redistribute plastic phenomena during the earthquake. Structural safety conditions will be defined according to a multi-level performance approach. The paper presents also some final suggestions for possible improvements and design simplifications.  相似文献   

19.
Unstiffened steel plate shear walls (SPSWs) are used as lateral load‐resisting systems in building structures. The energy dissipation mechanism of SPSWs consists of the tension yielding of web plates and the formation of plastic hinges at the ends of horizontal boundary elements. However, vertical boundary elements (VBEs) of high‐rise SPSWs may experience high axial forces under lateral loading. This study explores the effectiveness of staggering of web plates on the reduction of VBE forces and drift response of SPSWs during an earthquake event. An analytical study has been conducted to determine the base shear reduction factor so as to match the overstrength of staggered systems with conventional SPSWs. A design methodology has been proposed for staggered SPSWs. Six‐, 9‐, and 20‐storey staggered and conventional SPSWs with varying aspect ratios are considered in this study to compare their seismic response. These study frames are modelled and analysed in OpenSEES platform. Nonlinear static and dynamic analyses are performed to compare the drift response, hinge mechanisms, and steel tonnage. Staggered SPSWs showed uniform drift distribution and reduction in interstorey drift and axial force demand on the VBEs.  相似文献   

20.
Several seismic design codes around the world restrict the use of theit Equivalent Lateral Force analysis method to structures satisfying structural regularity limits. These regularity limits are based on engineering judgement and lack quantitative justification. One common irregularity is that of a change in vertical stiffness over the building height. This stiffness irregularity is almost always associated with a change in vertical strength over the building height. For this reason, the effect of various realistic combinations of stiffness–strength irregularity in shear‐type buildings is evaluated to quantify regularity limits. Structures analysed had 3, 5, 9 and 15 storeys, and the floor mass at all the levels were kept the same. Both regular and irregular structures were designed in accordance with the Equivalent Lateral Force procedure to produce the same engineering demand parameter. Structural ductility factors of 1, 2, 3, 4 and 6, and target (design) interstorey drift ratios ranging between 0.5 and 3%, were used in this study. The irregular structures were created by modifying specific storey lateral stiffnesses from that of the regular structure. Strengths at these storeys were also modified to ensure realistic relationships between stiffness and strength. The modified structures were then redesigned until the target interstorey drift ratio was achieved at the critical storey. Inelastic dynamic time‐history analysis was conducted to compare the maximum interstorey drift ratio demands of the regular and irregular structures. Simple equations were developed to estimate possible variations in demand due to vertical stiffness–strength irregularity applied at critical locations in structures. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   