The 1995 Hyogo-ken Nanbu (Kobe) earthquake brought about enormous damage to structures in the Hanshin and Awaji areas. In this paper the importance of investigating the relationship between ground motion and structural damage is pointed out.

Strong seismic motion was observed at the NTT (Nippon Telegraph and Telephone) Building during this earthquake. The structural damage to this building was relatively slight. In order to evaluate the relationship between ground motion and structural damage, it is necessary to assess the effects of the soil–structure interaction. In this study, the seismic response of the building and of the surface soil were evaluated by means of a nonlinear soil–structure interaction analysis using FEM.

It was found that, the nonlinearity of surface soil near the building had a great effect on the soil–structure interaction, especially the rocking of the building.  相似文献   


2.
Three variants of a two-dimensional (2-D) model of a building supported by a rectangular, flexible foundation embedded in nonlinear soil are analyzed. The building, the foundation, and soil have different physical properties. The building is assumed to be linear, but the foundation and the soil can experience nonlinear deformations. It is shown that the work spent for the development of nonlinear strains in the soil can consume a significant part of the input wave energy, and thus less energy is available for excitation of the building. The results help explain why the damage, during the 1994 Northridge earthquake in California, to residential buildings in the areas that experienced large strains in the soil was absent or reduced.  相似文献   

3.
This paper presents the results of a large-scale shake table test at E-Defense facility on a pile group located adjacent to a gravity-type quay wall and were subjected to liquefaction-induced large ground displacements. Extensive liquefaction-induced large ground lateral spreading displaced the quay wall about 2.2 m and damaged the pile foundation. The pile foundation consisted of a six-pile group which supported a footing and a superstructure model. Large lateral soil displacements were measured by several sensors such as inclinometers and the results favorably agreed with the directly observed deformations. Soil lateral displacement decreased as the distance from the quay wall increased landward. The piles were densely instrumented and the measured bending strain records were able to explain the damage to the piles. Lateral pressures of the liquefied soil exerted on the piles were measured using earth pressure (EP) sensors. The application of two design guidelines (JRA [1] and JSWA [2]) for estimation of liquefaction-induced lateral pressure on piles is discussed and their advantages and shortcomings are addressed. Furthermore, two simplified methods (Shamoto et al. [3] and Valsamis et al. [4]) are employed to predict the extent of liquefaction-induced large ground displacements and they are compared to the measured deformations. Finally, their accuracy for predicting the liquefaction-induced lateral displacements is evaluated and practical recommendations are made.  相似文献   

4.
2008年5月12日,四川省汶川县发生了里氏8.0级地震,造成了巨大的人员伤亡以及工程结构震害。位于震中映秀镇的漩口中学教学综合楼是按照《建筑抗震设计规范(GB50011-2001)》进行设计的,按7度进行抗震设防。在此次地震中,该建筑破坏严重,工程震害典型。为此,本文考虑了钢筋混凝土与砌体的材料非线性性质,建立了框架填充墙结构的非线性分析模型,进行了非线性有限元时程分析,分析了结构破坏的原因,讨论了填充墙体对结构抗震性能的影响,为该类结构的抗震设计提供了一定的依据。  相似文献   

5.
Damping formulation for nonlinear 1D site response analyses   总被引:2,自引:0,他引:2  
Measurements and observations of ground shaking during large earthquakes have demonstrated the predominant role of site effects in the response of infrastructure during a seismic event. Despite significant efforts to model the hysteretic response and nonlinearity of soils due to medium and large ground motions, the most widely accepted nonlinear site response methods are not able to represent simultaneously the changes of stiffness and energy dissipation (damping) observed in both laboratory tests and during earthquake events. This paper presents two new soil damping formulations implemented in nonlinear one-dimensional site response analysis for small and large strains. The first formulation introduces an approach to construct a frequency-independent viscous damping matrix which reduces the over-damping at high frequencies, and therefore, the filtering at those frequencies. The second formulation introduces a reduction factor that modifies the extended Masing loading/unloading strain–stress relationship to match measured modulus reduction and damping curves simultaneously over a wide range of shear strains. A set of examples are introduced to illustrate the effect of using the two proposed formulations, separately and simultaneously, in nonlinear site response analyses.  相似文献   

6.
A great number of free-field ground motion records are obtained during the 1999 Chi-Chi, Taiwan, earthquake. Records from 130 near fault free-field stations within 55 km to the causative fault surface are used as database, and characteristics of earthquake peak ground acceleration, velocity, displacement and duration are analyzed. According to this study, near fault ground motions are strongly affected by distance to fault, fault rupture directivity, site condition, as well as thrust of hanging wall. Compared with empirical strong ground motion attenuation relations used in China, US and Japan, the PGAs and PGVs recorded in this earthquake are not as large as what we have expected for a large earthquake as magnitude 7.6. However, the largest PGV and PGD worldwide were recorded in this event, which are 292 cm/s and 867 cm, respectively. Caused by nonlinear site effects of soil, peaks and corresponding ratios on E-class site were markedly different from those on other sites. Just as observed in historic earthquakes, fault rupture directivity effects caused significant differences between peaks of ground motion of two horizontal components, but took very slight effects on the duration of ground motion. The significant velocity pulses associated with large PGVs and PGDs, as well as large permanent displacements, which may result from the large thrust of the hanging wall, became the outstanding character of this event. Based on this study, we point out that 3D waveform modeling is needed to understand and predict near fault ground motion of large earthquakes.  相似文献   

7.
刘启方  陈长龙 《地震学报》2022,44(1):96-110
利用模拟记录和2011年日本东北MW9.0大地震观测记录分析了基于移动窗解卷积法识别场地非线性时变特征的可行性,并与移动窗谱比法的结果进行了对比分析。研究表明:基于移动窗解卷积法可以较好地揭示场地非线性随地震动水平的变化过程,识别非线性发生的阈值、非线性变化程度及强震动后的恢复程度;与移动窗谱比法相比,移动窗解卷积法更容易获得较为稳定的土体非线性时变过程,但对于存在强阻抗比的浅表层土体,移动窗谱比法可以获得更准确的非线性程度。对2011年日本东北MW9.0大地震中8个KiK-net台站进行了非线性时变分析,结果表明;两种方法识别的非线性阈值较接近,约在40—100 cm/s2之间,且与场地vS30没有明显的相关性;在峰值加速度PGA较低的IBRH20台站,非线性引起的波速下降较小(3%)且震后几乎完全恢复;PGA 处于386—822 cm/s2之间的其余7个台站,场地等效剪切波速下降13%—37%,产生了显著的场地非线性,且震后未完全恢复;PGA大于380 cm/s2时,非线性所导致的场地波速下降、恢复与PGA无明显相关性。   相似文献   

8.
This paper investigates numerically the seismic response of six seismically base‐isolated (BI) 20‐story reinforced concrete buildings and compares their response to that of a fixed‐base (FB) building with a similar structural system above ground. Located in Berkeley, California, 2 km from the Hayward fault, the buildings are designed with a core wall that provides most of the lateral force resistance above ground. For the BI buildings, the following are investigated: two isolation systems (both implemented below a three‐story basement), isolation periods equal to 4, 5, and 6 s, and two levels of flexural strength of the wall. The first isolation system combines tension‐resistant friction pendulum bearings and nonlinear fluid viscous dampers (NFVDs); the second combines low‐friction tension‐resistant crosslinear bearings, lead‐rubber bearings, and NFVDs. The designs of all buildings satisfy ASCE 7‐10 requirements, except that one component of horizontal excitation, is used in the 2D nonlinear response history analysis. Analysis is performed for a set of ground motions scaled to the design earthquake and to the maximum considered earthquake (MCE). At both the design earthquake and the MCE, the FB building develops large inelastic deformations and shear forces in the wall and large floor accelerations. At the MCE, four of the BI buildings experience nominally elastic response of the wall, with floor accelerations and shear forces being 0.25 to 0.55 times those experienced by the FB building. The response of the FB and four of the BI buildings to four unscaled historical pulse‐like near‐fault ground motions is also studied. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
In order to effectively utilize results from quasi-static cyclic testing on structural components for the earthquake-induced collapse risk quantification of structures, the need exists to establish collapse-consistent loading protocols representing the asymmetric lateral drift demands of structures under low-probability of occurrence earthquakes. This paper summarizes the development of such protocols for experimental testing of steel columns prone to inelastic local buckling. The protocols are fully defined with a deformation- and a force-controlled parameter. They are generally applicable to quantify the capacity and demands of steel columns experiencing constant and variable axial load coupled with lateral drift demands. Through rigorous nonlinear earthquake collapse simulations, it is found that the building height, the column's local slenderness ratio, and ground motion type have the largest influence on the dual-parameter loading protocol indexes. Comprehensive comparisons with measured data from full-scale shake table collapse tests suggest that unlike routinely used symmetric cyclic loading histories, the proposed loading protocol provides sufficient information for modeling strength and stiffness deterioration in steel columns at large inelastic deformations.  相似文献   

10.
To understand physical mechanisms of generation of abnormally high peak ground acceleration (PGA; >1g) during the Tohoku earthquake, models of nonlinear soil behavior in the strong motion were constructed for 27 KiK-net stations located in the near-fault zones to the south of FKSH17. The method of data processing used was developed by Pavlenko and Irikura, Pure Appl Geophys 160:2365–2379, 2003 and previously applied for studying soil behavior at vertical array sites during the 1995 Kobe (М w ?=?6.8) and 2000 Tottori (М w ?=?6.7) earthquakes. During the Tohoku earthquake, we did not observe a widespread nonlinearity of soft soils and reduction at the beginning of strong motion and recovery at the end of strong motion of shear moduli in soil layers, as usually observed during strong earthquakes. Manifestations of soil nonlinearity and reduction of shear moduli during strong motion were observed at sites located close to the source, in coastal areas. At remote sites, where abnormally high PGAs were recorded, shear moduli in soil layers increased and reached their maxima at the moments of the highest intensity of the strong motion, indicating soil hardening. Then, shear moduli reduced with decreasing the intensity of the strong motion. At soft-soil sites, the reduction of shear moduli was accompanied by a step-like decrease of the predominant frequencies of motion. Evidently, the observed soil hardening at the moments of the highest intensity of the strong motion contributed to the occurrence of abnormally high PGA, recorded during the Tohoku earthquake.  相似文献   

11.
Some spread footing foundations from real retrofitting practices in Taiwan were extended to be uneconomically large due to the restriction of foundation uplift regulated in the design code. Although rocking mode of spread footings induced from foundation uplift is not favorable in current design code, recent studies have shown that the rocking of a spread footing may have a beneficial effect on the dynamic performance of piers by reducing the earthquake forces that can be transmitted to the pier base. This implies that the plastic deformation that occurs at the pier's plastic zone can be decreased and as a result the ductility demand of piers can possibly be reduced. In order to gain a better understanding of the structural behavior related to rocking and to clarify that if the widening and strengthening of the foundations to limit the rocking mechanism of spread footing is necessary for the retrofitting work, a series of preliminary rocking experiments were performed. A total of three circular reinforced concrete columns with spread footing foundations were tested. Using pseudo‐dynamic tests and a cyclic loading test, these columns were subjected to different levels of earthquake accelerations, including a near field ground motion. The results of the tests and the rocking behavior of the footings are discussed in this paper. From the benchmark test, the difference between the response behavior of a rocking base and a fixed base foundation was highlighted. By comparing the experimental responses of the retrofitted column with the responses of the original one, the effect of the rocking mechanism on the ductility demand and strength demand of the columns was also identified. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
Fluctuations in axial load imposed on a rocking footing will affect its moment capacity, the shape of its moment–rotation hysteresis, and potentially the system's seismic performance. Structural asymmetry increases the likelihood of axial load variation during earthquake excitations. To investigate this issue, a unique centrifuge testing program was carried out on low‐rise frame–wall–rocking foundation systems. In this paper, the seismic behaviors of asymmetric and symmetric models from this test program are systematically compared. Experimental results reveal that placing the lateral force resisting shear wall outboard produces significant axial load fluctuation, which in turn greatly deteriorate the lateral load‐carrying capacity of a foundation rocking dominated frame–wall system, particularly in its weak direction. However, it strengthens the system when loading is towards the shear wall, leading to a highly asymmetric hysteretic response. During earthquake loading, all asymmetric rocking foundation systems observe smaller peak roof accelerations, but larger peak and permanent roof drifts compared with the symmetric systems. Despite these differences in response, the axial load fluctuation and structural asymmetry do not significantly change the relative energy dissipated by the rocking foundations and inelastic structural components within each frame–wall–rocking foundation model. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
Strong motion records provided by seismic vertical arrays allow estimation of stress–strain relations in soils at depths from the surface to the location of the deepest device. As an example, time-dependent nonlinear soil behavior was estimated in vertical components of records obtained in the epicentral area of the 1995 Kobe earthquake. Degradation of the rigidity of soils in the strong motion was observed. The constructed nonlinear models of the soil behavior were used for estimating the nonlinear parts in the ground response by the nonlinear system identification technique. Nonlinear parts in the ground response were found to be as high as 50% at 2 km from the fault and 10% at 6–15 km from the fault plane. Odd types of nonlinearity, such as cubic, the fifth, seventh, etc. order, were found to be typical for soils, whereas, nonlinearities of even types are usually weak, but increase in liquefied soils.  相似文献   

14.
将土体视为固-液两相介质,基于饱和土体有效应力原理,建立饱和土体-地下综合管廊结构体系相互作用动力模型:在地应力平衡的静力状态下,采用Duncan-Chang非线性弹性本构模型,在地震波作用的动力状态下,采用Davidenkov非线性黏弹性本构模型;考虑饱和土体黏弹性动力人工边界条件,并将地震动作用转化为作用在人工边界节点上的动力荷载。模型考察不同土体材料、结构特性以及土-结构接触摩擦对结构地震响应的影响,得出如下结论:(1)地震波的卓越周期与场地卓越周期相近时,引起结构上的变形最大;(2)综合管廊结构管廊壁厚越薄,埋深越深,结构尺寸越大,结构刚度越小,结构变形越大;(3)不考虑土-结构接触面的状态非线性将会增大结构变形。  相似文献   

15.
The critical parameters that influence the nonlinear seismic response of asymmetric‐plan buildings are identified by evaluating the effects of different asymmetries that may characterize the structure of a building as well as exploring the influence of the ground motion features. First, the main findings reported in the literature on both the linear and nonlinear dynamic response of asymmetric‐plan buildings are presented. The common findings and the conflicting conclusions reached in different investigations are pointed out. Then, the results of comprehensive nonlinear dynamic analyses performed for evaluating the seismic response of systems characterized by different strength and stiffness configurations, representative of a large class of asymmetric‐plan buildings, are reported. Findings from the study indicate that the building response changes when moving from the linear to the nonlinear range, so that the seismic behavior of asymmetric‐plan buildings, apart from the source of asymmetry, can be always classified as irregular. Additionally, it was observed that as the seismic demands cause amplification of system nonlinearity with increasing earthquake intensity, the maximum displacement demand in the different resisting elements tends to be reached with the same deformed configuration of the system. The resultant of the seismic forces producing such a maximum demand is located at the center of resistance and corresponds to the collapse mechanism of the system that provides the maximum lateral strength in the exciting direction of the seismic action. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

16.
基于轴向位移的钢支撑疲劳损伤评估方法   总被引:1,自引:0,他引:1  
在罕遇地震下,框架-中心支撑结构中的钢支撑常因局部屈曲位置的低周疲劳开裂而过早退出工作。本文在焊接工字形钢支撑低周疲劳试验研究基础上,提出了一种可用于框架-中心支撑体系非线性动力时程分析中钢支撑疲劳损伤评估的经验方法,并给出了相关步骤的算法流程。研究结果表明:本文方法以钢支撑轴向位移为损伤参量,能实时估算在随机位移荷载下钢支撑的低周疲劳累积损伤发展,并与试验结果吻合较好。  相似文献   

17.
Distribution of parameters characterizing soil response during the 1999 Chi-Chi, Taiwan, earthquake (M w = 7.6) around the fault plane is studied. The results of stochastic finite-fault simulations performed in Pavlenko and Wen (2008) and constructed models of soil behavior at 31 soil sites were used for the estimation of amplification of seismic waves in soil layers, average stresses, strains, and shear moduli reduction in the upper 30 m of soil, as well as nonlinear components of soil response during the Chi-Chi earthquake. Amplification factors were found to increase with increasing distance from the fault (or, with decreasing the level of “input” motion to soil layers), whereas average stresses and strains, shear moduli reduction, and nonlinear components of soil response decrease with distance as ~ r ?1 . The area of strong nonlinearity, where soil behavior is substantially nonlinear (the content of nonlinear components in soil response is more than ~40–50% of the intensity of the response), and spectra of oscillations on the surface take the smoothed form close to E(f) ~ f ?n , is located within ~20–25 km from the fault plane (~ 1/4 of its length). Nonlinearity decreases with increasing distance from the fault, and at ~40–50 km from the fault (~ 1/2 of the fault length), soil response becomes virtually linear. Comparing soil behavior in near-fault zones during the 1999 Chi-Chi, the 1995 Kobe (M w = 6.8), and the 2000 Tottori (Japan) (M w = 6.7) earthquakes, we found similarity in the behavior of similar soils and predominance of the hard type of soil behavior. Resonant phenomena in upper soil layers were observed at many studied sites; however, during the Chi-Chi earthquake they involved deeper layers (down to ~ 40–60 m) than during lesser-magnitude Kobe and Tottori earthquakes.  相似文献   

18.
Novel approaches to the dynamic analysis of the reinforced soil walls have been reported in the literature. Use of marginal soils reduces the cost of geosynthetic reinforced soil walls if proper drainage measures are taken. Therefore the affect of using cohesive marginal soils as backfill in geosynthetic reinforced retaining structures were investigated in this research. The dynamic response of reinforced soil walls was investigated in a similar focus, using finite element analysis. The results obtained from walls with cohesive backfill were compared to the results obtained from walls with granular backfill. The height of the wall was chosen as 6 m in the two-dimensional plane strain finite element model and the base acceleration was chosen to be a harmonic motion. The effects of various parameters like the backfill type, facing type, reinforcement stiffness, and peak ground acceleration on the cyclic response of reinforced soil retaining walls were investigated. After analyzing the wall response for end of construction and dynamic excitation phases, it was determined that the deformations and reinforcement tensile loads increased during the cyclic load application and that the amount of additional deformation that occurred during cyclic load application was strongly related to backfill soil type, facing type, reinforcement type and peak ground acceleration. It was determined that a cohesive backfill and geotextile reinforcement was a good combination to reduce the deformations of geosynthetic reinforced walls during cyclic loading for medium height walls.  相似文献   

19.
Due to the increased need of storage, larger and higher structures are being built all over the world, thus requiring a more careful evaluation of the mechanical performance of their foundation deposits both in terms of bearing capacity and compressibility behaviour. The design of such structures and their serviceability and stability is largely governed by the effects of the dynamic loading conditions principally because of their significantly elevated risk in seismic prone zones. In this paper, numerical analyses using an advanced constitutive model, able to account for the initial soil structure and its progressive degradation, have been performed to investigate the seismic response of a silo foundation built on structured clays. The proposed analyses involve the use of a fully-coupled finite element approach. For the dynamic simulations, three different input motions have been selected form earthquake databases according to the seismic hazard study of the specific site. The results of the silo dynamic response are illustrated in terms of signal amplification, permanent excess pore water pressures, accumulated displacements and structure induced degradation during and after the seismic loading. The dynamic behaviour of the footing indicates that extreme earthquake events can induce large destructuration in natural clays, leading to ground settlements up to twice the observed ones under static loads, which need to be properly accounted for in the design. This suggests that there are significant advantages in using advanced models which recognise the existence of initial soil structure and its subsequent damage due to the applied dynamic loads.  相似文献   

20.
The spatial relationship between areas with severely damaged (red-tagged) buildings and areas with large strains in the soil (indicated by reported breaks in the water distribution system), observed during the 1994 Northridge earthquake, is analysed. It is shown that these areas can be separated almost everywhere. Minimal overlapping is observed only in the regions with very large amplitudes of shaking (peak ground velocity exceeding about 150 cm s−1). One explanation for this remarkable separation is that the buildings on ‘soft’ soils, which experienced nonlinear strain levels, were damaged to a lesser degree, possibly because the soil absorbed a significant portion of the incident seismic wave energy. As a result, the total number of severely damaged (red-tagged) buildings in San Fernando Valley, Los Angeles and Santa Monica may have been reduced by a factor of two or more. This interpretation is consistent with the recorded peak accelerations of strong motion in the same area. It is concluded that significant reduction in the potential damage to wood frame single family dwellings may be expected in areas where the soil experiences ‘large’ strains (beyond the linear range) during strong earthquake shaking, but not significant differential motions, settlement or lateral spreading, near the surface.  相似文献   