首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
The evaluation of the out‐of‐plane behaviour of unreinforced walls is one of the most debated topics in the seismic assessment of existing masonry buildings. The discontinuous nature of masonry and its interaction with the remainder of the building make the dynamic modelling of out‐of‐plane response troublesome. In this paper, the results of a shaking table laboratory campaign on a tuff masonry, natural scale, U‐shaped assemblage (façade adjacent to transverse walls) are presented. The tests, excited by scaled natural accelerograms, replicate the behaviour of external walls in existing masonry buildings, from the beginning of rocking motion to overturning. Two approaches have been developed for modelling the out‐of‐plane seismic behaviour: the discrete element method and an SDOF analytic model. Both approaches are shown to be capable of reproducing the experimental behaviour in terms of maximum rotation and time history dynamic response. Finally, test results and numerical time history simulations have been compared with the Italian seismic code assessment procedures. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

2.
A new hybrid ductile‐rocking seismic‐resistant design is proposed which consists of a code‐designed buckling‐restrained braced frame (BRBF) that yields along its height and also partially rocks on its foundation. The goal of this system is to cost‐effectively improve the performance of BRBFs, by reducing drift concentrations and residual deformations, while taking advantage of their large ductility and their reliable limit on seismic forces and accelerations along a building's height. A lock‐up device ensures that the full code‐compliant lateral strength can be achieved after a limited amount of column uplift, and supplemental energy dissipation elements are used to reduce the rocking response. This paper outlines the mechanics of the system and then presents analyses on rocking frames with both ductile and elastic braces in order to highlight the large higher mode demands on elastic rocking frames. A parametric study using nonlinear time‐history analysis of BRBF structures designed according to the proposed procedure for Los Angeles, California is then presented. This study investigates the system's seismic response and the effect of different energy dissipation element properties and allowable base rotation values before the lock‐up is engaged. Finally, the effect of vertical mass modeling on analysis results was investigated. These studies demonstrated that the hybrid ductile‐rocking system can in fact improve the global peak and residual deformation response as well as reduce brace damage. This enhanced performance could eliminate the need for expensive repairs or demolition that are otherwise to be expected for conventional ductile fixed base buildings that sustain severe damage.  相似文献   

3.
Some spread footing foundations from real retrofitting practices in Taiwan were extended to be uneconomically large due to the restriction of foundation uplift regulated in the design code. Although rocking mode of spread footings induced from foundation uplift is not favorable in current design code, recent studies have shown that the rocking of a spread footing may have a beneficial effect on the dynamic performance of piers by reducing the earthquake forces that can be transmitted to the pier base. This implies that the plastic deformation that occurs at the pier's plastic zone can be decreased and as a result the ductility demand of piers can possibly be reduced. In order to gain a better understanding of the structural behavior related to rocking and to clarify that if the widening and strengthening of the foundations to limit the rocking mechanism of spread footing is necessary for the retrofitting work, a series of preliminary rocking experiments were performed. A total of three circular reinforced concrete columns with spread footing foundations were tested. Using pseudo‐dynamic tests and a cyclic loading test, these columns were subjected to different levels of earthquake accelerations, including a near field ground motion. The results of the tests and the rocking behavior of the footings are discussed in this paper. From the benchmark test, the difference between the response behavior of a rocking base and a fixed base foundation was highlighted. By comparing the experimental responses of the retrofitted column with the responses of the original one, the effect of the rocking mechanism on the ductility demand and strength demand of the columns was also identified. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
An effective method for the seismic retrofitting of the sidewalls of cut‐and‐cover tunnels has not yet been established. Thus, a new method of seismic retrofitting for cut‐and‐cover tunnels, called the ‘polymer isolation method’, is developed here. In this method, thin walls made of polymer materials, called ‘isolation walls’, are inserted between the ground and the sidewalls of a tunnel. We demonstrate the effectiveness of the proposed method in reducing the seismic response of tunnels by using some numerical simulations. It is found that the proposed method depends on the thickness of the soil cover over the tunnel and the ratio of the stiffness between the soil and the structure. Furthermore, a simple chart is proposed for convenience to represent the applicability of the polymer isolation method to the design of seismic retrofits for cut‐and‐cover tunnels. Although this particular chart has been obtained through a limited case, some other typical cases in which the chart can also be implemented for special conditions are addressed, and the applicability and the limitations of this chart are suggested for possible conditions of the ground and of tunnel structures. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
An application of a pin‐supported wall‐frame system in retrofitting an eleven‐story steel reinforced concrete frame is introduced. The retrofit aims at enhancing integrity and avoiding weak story failure in an existing moment‐resisting frame. Seismic performance of the building before and after the retrofit is assessed through nonlinear dynamic analysis. The results show that the pin‐supported walls are effective in controlling the deformation pattern of the ductile frame and hence in avoiding weak story failure. With the well‐controlled deformation pattern, carefully arranged energy dissipating devices are able to concentrate energy dissipations so that damage to the rest of the structure can be significantly reduced. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
Historic adobe structures pose a high seismic risk mainly because of the poor out-of-plane bending response of their walls that may produce fatalities and significant economic, cultural, and heritage losses. In this paper, we propose a retrofitting technique that increases the wall strength for both in-plane and out-of-plane directions. This technique consists of vertical and horizontal timber elements symmetrically installed on each face of the wall to form a confining wood frame, supplemented with vertical tensors that pre-compress the wall. This study evaluates the performance of this retrofitting technique with a two-set experimental program on full-scale historic adobe walls. On the first set, four specimens were subjected to a static overturning test with boundary conditions representing the confinement effect at both ends by orthogonal walls. On the second set, three full-scale specimens, one unretrofitted and two retrofitted, were subjected to four ground motion records on a shaking table to assess the out-of-plane dynamic behavior of typical corner walls. The unretrofitted specimen collapsed during the second motion (peak ground acceleration [PGA] = 0.39 g), while both retrofitted walls survived all four motions (maximum PGA of 0.75 g) proving the high effectiveness of the proposed retrofitting. The addition of base anchors as a variation of the retrofitting technique significantly reduced the rocking effects and the residual drifts of the system, thus improving its overall seismic performance. Further research is needed to develop guidelines for seismic retrofit of heritage buildings including multistory full-scale tests of specimens with various types of openings and retrofitting strategies that minimize their architectural impact.  相似文献   

7.
Earthquake‐resilient steel frames, such as self‐centering frames or frames with passive energy dissipation devices, have been extensively studied during the past decade, but little attention has been paid to their column bases. The paper presents a rocking damage‐free steel column base, which uses post‐tensioned high‐strength steel bars to control rocking behavior and friction devices to dissipate seismic energy. Contrary to conventional steel column bases, the rocking column base exhibits monotonic and cyclic moment–rotation behaviors that are easily described using simple analytical equations. Analytical equations are provided for different cases including structural limit states that involve yielding or loss of post‐tensioning in the post‐tensioned bars. A step‐by‐step design procedure is presented, which ensures damage‐free behavior, self‐centering capability, and adequate energy dissipation capacity for a predefined target rotation. A 3D nonlinear finite element (FE) model of the column base is developed in abaqus . The results of the FE simulations validate the accuracy of the moment–rotation analytical equations and demonstrate the efficiency of the design procedure. Moreover, a simplified model for the column base is developed in OpenSees . Comparisons among the OpenSees and abaqus models demonstrate the efficiency of the former and its adequacy to be used in nonlinear dynamic analysis. A prototype steel building is designed as a self‐centering moment‐resisting frame with conventional or rocking column bases. Nonlinear dynamic analyses show that the rocking column base fully protects the first story columns from yielding and eliminates the first story residual drift without any detrimental effect on peak interstory drifts. The study focuses on the 2D rocking motion and, thus, ignores 3D rocking effects such as biaxial bending deformations in the friction devices. The FE models, the analytical equations, and the design procedure will be updated and validated to cover 3D rocking motion effects after forthcoming experimental tests on the column base. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

8.
Precast concrete walls with unbonded post‐tensioning provide a simple self‐centering system. Yet, its application in seismic regions is not permitted as it is assumed to have no energy dissipation through a hysteretic mechanism. These walls, however, dissipate energy imparted to them because of the wall impacting the foundation during rocking and limited hysteretic action resulting from concrete nonlinearity. The energy dissipated due to rocking was ignored in previous experimental studies because they were conducted primarily using quasi‐static loading. Relying only on limited energy dissipation, a shake table study was conducted on four single rocking walls (SRWs) using multiple‐level earthquake input motions. All walls generally performed satisfactorily up to the design‐level earthquakes when their performance was assessed in terms of the maximum transient drift, maximum absolute acceleration, and residual drift. However, for the maximum considered earthquakes, the walls experienced peak lateral drifts greater than the permissible limits. Combining the experimental results with an analytical investigation, it is shown that SRWs can be designed as earthquake force‐resisting elements to produce satisfactory performance under design‐level and higher‐intensity earthquake motions. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
This paper presents the results on shaking table tests of half‐scale brick walls performed to investigate the effectiveness of newly developed Cu–Al–Mn superelastic alloy (SEA) bars in retrofitting of historical masonry constructions. Problems associated with conventional steel reinforcing bars lie in degradation of stiffness and strength, or pinching phenomena, under cyclic loading, and presence of large residual cracks in structures during and after intense earthquakes. This paper attempts to resolve the problems by applying newly developed Cu–Al–Mn SEA bars, characterized by large recovery strain, low material cost, and high machinability, as partial replacements for steel bars. Sets of unreinforced, steel reinforced, and SEA‐reinforced specimens are subjected to scaled earthquake excitations in out‐of‐plane direction. Whereas steel‐reinforced specimens showed large residual inclinations, SEA‐reinforced specimens resulted in stable rocking response with slight residual inclinations. Corresponding nonlinear finite element (FE) models are developed to simulate the experimental observations. The FE models are further used to examine the sensitivity of the response with respect to the variations in experimental conditions. Both the experimental and numerical results demonstrate the superiority of Cu–Al–Mn SEA bars to conventional steel reinforcing bars in avoiding pinching phenomena. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

10.
The self‐centering rocking steel frame is a seismic force resisting system in which a gap is allowed to form between a concentrically braced steel frame and the foundation. Downward vertical force applied to the rocking frame by post‐tensioning acts to close the uplifting gap and thus produces a restoring force. A key feature of the system is replaceable energy‐dissipating devices that act as structural fuses by producing high initial system stiffness and then yielding to dissipate energy from the input loading and protect the remaining portions of the structure from damage. In this research, a series of large‐scale hybrid simulation tests were performed to investigate the seismic performance of the self‐centering rocking steel frame and in particular, the ability of the controlled rocking system to self‐center the entire building. The hybrid simulation experiments were conducted in conjunction with computational modules, one that simulated the destabilizing P‐Δ effect and another module that simulated the hysteretic behavior of the rest of the building including simple composite steel/concrete shear beam‐to‐column connections and partition walls. These tests complement a series of quasi‐static cyclic and dynamic shake table tests that have been conducted on this system in prior work. The hybrid simulation tests validated the expected seismic performance as the system was subjected to ground motions in excess of the maximum considered earthquake, produced virtually no residual drift after every ground motion, did not produce inelasticity in the steel frame or post‐tensioning, and concentrated the inelasticity in fuse elements that were easily replaced. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
A design procedure for seismic retrofitting of concentrically and eccentrically braced frame buildings is proposed and validated in this paper. Rocking walls are added to the existing system to ensure an almost uniform distribution of the interstorey displacement in elevation. To achieve direct and efficient control over the seismic performance, the design procedure is founded on the displacement‐based approach and makes use of overdamped elastic response spectra. The top displacement capacity of the building is evaluated based on a rigid lateral deformed configuration of the structure and on the ductility capacity of the dissipative members of the braced frames. The equivalent viscous damping ratio of the braced structure with rocking walls is calculated based on semi‐empirical relationships specifically calibrated in this paper for concentrically and eccentrically braced frames. If the equivalent viscous damping ratio of the structure is lower than the required equivalent viscous damping ratio, viscous dampers are added and arranged between the rocking walls and adjacent reaction columns. The design internal forces of the rocking walls are evaluated considering the contributions of more than one mode of vibration. The proposed design procedure is applied to a large set of archetype braced frame buildings and its effectiveness verified by nonlinear dynamic analysis.  相似文献   

12.
Results obtained for rigid structures suggest that rocking can be used as seismic response modification strategy. However, actual structures are not rigid: structural elements where rocking is expected to occur are often slender and flexible. Modeling of the rocking motion and impact of flexible bodies is a challenging task. A non‐linear elastic viscously damped zero‐length spring rocking model, directly usable in conventional finite element software, is presented in this paper. The flexible rocking body is modeled using a conventional beam‐column element with distributed masses. This model is verified by comparing its pulse excitation response to the corresponding analytical solution and validated by overturning analysis of rocking blocks subjected to a recorded ground motion excitation. The rigid rocking block model provides a good approximation of the seismic response of solitary flexible columns designed to uplift when excited by pulse‐like ground motions. Guidance for development of rocking column models in ordinary finite element software is provided. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

13.
This paper presents the results of an experimental work in order to evaluate the performance of a novel proposed retrofitting technique on a typical dome‐roof adobe building by shaking table tests. For this purpose, two specimens, scaled 2:3, were subjected to a total of nine shaking table tests. The unretrofitted specimen, constructed by common practice, is designed to evaluate seismic performance and vulnerability of dome‐roof adobe houses. The retrofitted specimen, exactly duplicating the first specimen, is retrofitted based on the results obtained from unretrofitted specimen tests, and the improvement in seismic behavior of the structure is investigated. Zarand earthquake (2005) Chatrood Station is selected as the input ground motion that was applied consecutively at 25, 100, 125, 150 and 175% of the design‐level excitation. At 125% excitation level, the roof of the unretofitted specimen collapsed due to the walls' out‐of‐plane action and imbalanced forces. The retrofitting elements consist of eight horizontal steel rods drilled into the walls, passed through the specimen and bolted on the opposite wall surfaces. To improve walls in‐plane seismic performance, welded steel mesh without using mortar, covered less than half area of walls on the external face of the walls, is used. In addition to strain gauges for recording steel rod responses, several instrumentations including acceleration and displacement transducers are implemented to capture response time histories of different parts of the specimens. The corresponding full‐scaled retrofitted prototype tolerated peak acceleration of 0.62 g almost without any serious damage. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

14.
This article presents a new mechanical model for the non‐linear force–displacement response of unreinforced masonry (URM) walls developing a flexural rocking mode including their displacement capacity. The model is based on the plane‐section hypothesis and a constitutive law for the masonry with zero tensile strength and linear elastic behaviour in compression. It is assumed that only the compressed part of the wall contributes to the stiffness of the wall and therefore the model accounts for a softening of the response due the reduction of the effective area. Stress conditions for limit states are proposed that characterise the flexural failure. The new model allows therefore linking local performance levels to global displacement capacities. The limit states criteria describe the behaviour of modern URM walls with cement mortar of normal thickness and clay bricks. The model is validated through comparison of local and global engineering demand parameters with experimental results. It provides good prediction of the effective stiffness, the force capacity and the displacement capacity of URM walls at different limit states. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
This article examines the use of rocking steel braced frames for the retrofit of existing seismically deficient steel building structures. Rocking is also used to achieve superior seismic performance to reduce repair costs and disruption time after earthquakes. The study focuses on low‐rise buildings for which re‐centring is solely provided by gravity loads rather than added post‐tensioning elements. Friction energy dissipative (ED) devices are used to control drifts. The system is applied to 2‐storey and 3‐storey structures located in 2 seismically active regions of Canada. Firm ground and soft soil conditions are considered. The seismic performance of the retrofit scheme is evaluated using nonlinear dynamic analysis and ASCE 41‐13. For all structures, rocking permits to achieve immediate occupancy performance under 2% in 50 years seismic hazard if the braces and their connections at the building's top storeys are strengthened to resist amplified forces due to higher mode response. Base shears are also increased due to higher modes. Impact at column bases upon rocking induces magnified column forces and vertical response in the gravity system. Friction ED is found more effective for drift control than systems with ring springs or bars yielding in tension. Drifts are sufficiently small to achieve position retention performance for most nonstructural components. Horizontal accelerations are generally lower than predicted from ASCE 41 for regular nonrocking structures. Vertical accelerations in the gravity framing directly connected to the rocking frame are however higher than those predicted for ordinary structures. Vertical ground motions have limited effect on frame response.  相似文献   

16.
In modern unreinforced masonry buildings with stiff RC slabs, walls of the top floor are most susceptible to out‐of‐plane failure. The out‐of‐plane response depends not only on the acceleration demand and wall geometry but also on the static and kinematic boundary conditions of the walls. This paper discusses the influence of these boundary conditions on the out‐of‐plane response through evaluation of shake table test results and numerical modelling. As a novum, it shows that the in‐plane response of flanking elements, which are orthogonal to the wall whose out‐of‐plane response is studied, has a significant influence on the vertical restraint at the top of the walls. The most critical configuration exists if the flanking elements are unreinforced masonry walls that rock. In this case, the floor slabs can uplift, and the out‐of‐plane load‐bearing walls loose the vertical restraint at the top. Numerical modelling confirms this experimentally observed behaviour and shows that slab uplift and the difference in base and top excitation have a strong influence on the out‐of‐plane response of the walls analysed. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

17.
Near‐fault ground motions with forward directivity are characterized by a large pulse. This pulse‐like motion may cause a highly non‐uniform distribution of story ductility demands for code‐compliant frame structures, with maximum demands that may considerably exceed the level of code expectations. Strengthening techniques for multi‐story frame structures are explored with the objective of reducing maximum drift demands. One option is to modify the code‐based SRSS distribution of story shear strength over the height by strengthening of the lower stories of the frame. The modified distribution reduces the maximum story ductility demand, particularly for weak and flexible structures. However, this strengthening technique is less effective for stiff structures, and is almost ineffective in cases in which the maximum demand occurs in the upper stories, i.e. strong and flexible structures. As an alternative, the benefits of strengthening frames with elastic and inelastic walls are evaluated. The effects of adding walls that are either fixed or hinged at the base are investigated. It is demonstrated that strengthening with hinged walls is very effective in reducing drift demands for structures with a wide range of periods and at various performance levels. Wall inelastic behavior only slightly reduces the benefits of strengthening with hinged walls.Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

18.
This paper characterizes the ability of natural ground motions to induce rocking demands on rigid structures. In particular, focusing on rocking blocks of different size and slenderness subjected to a large number of historic earthquake records, the study unveils the predominant importance of the strong‐motion duration to rocking amplification (ie, peak rocking response without overturning). It proposes original dimensionless intensity measures (IMs), which capture the total duration (or total impulse accordingly) of the time intervals during which the ground motion is capable of triggering rocking motion. The results show that the proposed duration‐based IMs outperform all other examined (intensity, frequency, duration, and/or energy‐based) scalar IMs in terms of both “efficiency” and “sufficiency.” Further, the pertinent probabilistic seismic demand models offer a prediction of the peak rocking demand, which is adequately “universal” and of satisfactory accuracy. Lastly, the analysis shows that an IM that “efficiently” captures rocking amplification is not necessarily an “efficient” IM for predicting rocking overturning, which is dominated by the velocity characteristics (eg, peak velocity) of the ground motion.  相似文献   

19.
A simplified numerical model was used to investigate the out‐of‐plane seismic response of vertically spanning unreinforced masonry (URM) wall strips. The URM wall strips were assumed to span between two flexible diaphragms and to develop a horizontal crack above the wall mid‐height. Three degrees of freedom were used to accommodate the wall displacement at the crack height and at the diaphragm connections, and the wall dynamic stability was studied. The equations of dynamic motion were obtained using principles of rocking mechanics of rigid bodies, and the formulae were modified to include semi‐rigid wall behaviour. Parametric studies were conducted that included calculation of the wall response for different values of diaphragm stiffness, wall properties, applied overburden, wall geometry and earthquake ground motions. The results of the study suggest that stiffening the horizontal diaphragms of typical low‐rise URM buildings will amplify the out‐of‐plane acceleration demand imposed on the wall and especially on the wall–diaphragm connections. It was found that upper‐storey walls connected to two flexible diaphragms had reduced stability for applied earthquake accelerograms having dominant frequency content that was comparable with the frequency of the diaphragms. It was also found that the applied overburden reduced wall stability by reducing the allowable wall rotations. The results of this study suggest that the existing American Society of Civil Engineers recommendations for assessment of vertically spanning walls overestimate the stability of top‐storey walls in multi‐storey buildings in high‐seismic regions or for walls connected to larger period (less stiff) diaphragms. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
There are numerous studies on the behavior of Unreinforced Masonry (URM) walls in both in‐plane (IP) and out‐of‐plane (OP) directions; however, few aimed at understanding the simultaneous contribution of these intrinsic responses during earthquakes. Undoubtedly, even a strong URM wall shows weakened capacity in the OP direction because of minor cracks and other damages in the IP direction, and this capacity reduction has not yet been accounted for in seismic codes. In this study, performance of three URM walls is evaluated by several numerical analyses in terms of the OP capacity reduction because of IP displacements and failure modes. Several parameters influencing the OP capacity have been studied including aspect ratio, roof boundary condition, IP displacement and IP loading patterns. The results indicate that reduction in the OP capacity of URM walls varies from negligible to very high depending on boundary conditions, IP failure mode and IP damage severity. Moreover, IP loading pattern is more important in walls with higher aspect ratios because of their IP failure modes. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号