首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A new type ofin situ filtration sampler is described. The all Teflon sampler is hung on a nylon rope attached to a steel wire (Fig. 3). By dropping a messenger, the sampler piston is pulled down by a released weight of 50 kg, and the sampler is filled with about 400 ml of filtered water. The sample is not contaminated by metals because there is no metal around the sampler.  相似文献   

2.
The construction and testing of a low cost, simple, intertidal and sub-tidal pore water sampler for use in sandy and muddy substrates are described in this note. The sampler, “porextractor”, is made of polyvinyl chloride (PVC) plumbing materials that can be readily sourced at any local hardware shop and costs AU $ 15.00 to build. The only mechanical component of the porextractor is a plunger that is used only once at the time of deployment. The porextractor has been designed for use on seagrass beds to collect pore water samples with minimal disturbance to the substratum for nutrient flux studies. The relative efficiency of the porextractor was tested against the widely used “Winger and Lasier” sampler, a vacuum operated diffuser stone pore water sampler. The two samplers were compared for the volume of pore water collected in sandy and muddy substrates in the laboratory, and the concentrations of total nitrogen and total phosphorus in samples collected from a sandy substrate in Amphibolis and Posidonia seagrass meadows off the Adelaide coast. While the porextractor and the Winger and Lasier samplers worked equally well in the sandy sediments, the porextractor was more efficient than the latter in muddy sediments, where clogging was a major problem. In addition, there were no significant differences (p  0.05) in the concentrations of total nitrogen and total phosphorus measured from the pore water samples collected by the two samplers in situ from the seagrass bed. The simplicity, ease of construction, non-substrate specificity, and large sample volume yield are some of the major merits of the porextractor over other conventional techniques used for pore water sampling.  相似文献   

3.
A sampler which permits concentration of both particulate and dissolved radionuclides from large volumes of ocean and freshwater has been developed and tested. The water sample passes through a filtration section for particle removal, then through a sorption section where the radionuclides of interest are removed on sorption or ion exchange beds. Components of the sampler which contact the water are of polyvinyl chloride construction, and flow rates of about 40 l./min are employed. This sampler has been successfully employed in concentrating some twenty radionuclides from ocean and fresh waters.  相似文献   

4.
A cylinder-type sampler, which is attached to the rod of Van Dorn sampler, was newly deviced for microbiological collection of 3-liter water samples from shallow layers.  相似文献   

5.
大容量海水采水器的研制   总被引:1,自引:0,他引:1  
留籍援  黄财宾  陈坚 《台湾海峡》2006,25(1):139-142
介绍一种实用新型的采水器,该采水器具有全新的开闭装置及密封结构.文章对采水器的构造、工作原理及特点进行了有益的探讨。  相似文献   

6.
Two sampling devices for the in situ extraction of chlorinated hydrocarbons from water are described. Both samplers use the macroreticular adsorbent Amberlite XAD-2. They include a “fish” sampler which has been used to collect samples for PCB analysis from waters around the British Isles. Operation of this sampler causes a minimum of interruption to a ship's cruise programme and at the same time allows a large area to be surveyed. The second sampler is a self-powered in situ pump which is cheap to construct and can be left unattended to extract large volumes of water at a fixed station. The device is serviced by divers and samples may be collected daily on a routine sampling basis.  相似文献   

7.
A Remotely Operated Serial Sampler for Collecting Gas-Tight Fluid Samples   总被引:1,自引:1,他引:0  
This paper describes the design, construction and preliminary test results for a gas-tight serial sampler intended to be deployed at seafloor for long-term operation to take time-series fluid samples from deep-sea environments such as cold seeps, water column and hydrothermal vents. The serial sampler is a modular system that is based on independent and identical sampling modules, which are designed to collect six 160 ml gas-tight fluid samples maintained at high pressure to a depth of 4000 meters. With two working modes, the sampler can be deployed either with seafloor cabled observatory for remote control or as a stand-alone device for autonomous operation. A prototype of the instrument has been constructed and tested on the MARS cabled observatory for two months. The laboratory and field tests proved the success of the design and construction of the serial sampler, and indicated the potential for future ocean sciences.  相似文献   

8.
本系统是国家“863”任务中818-02A项目的重要组成部 和高精度CTD测量仪联用,可以完成任意深度、任意时刻的采水控制功能,它采用国内外最新的技术和元器件,打破了原有的采水控制装置的设计思想,使采水器的动作完全合理准确。本文重点介绍其工作原理和关键技术。  相似文献   

9.
A suction sediment sampler has been developed for sampling suspended sand in the field. It works by the pressure difference between seabed and water surface, and thus no pump is required. The fact that the sampler has no mechanical moving parts and no electronics makes it very dependable. Seven samples are taken simultaneously at different elevations starting at about 1 cm above the bed. The sampling time is about 3 min for water depths of about 1.5 m. Sixty-five concentration profiles, complete with hydraulic data and sediment characteristics are given in the appendix.  相似文献   

10.
We have proposed a time-weighted measurement using blue rayon that selectively adsorbs and concentrates polycyclic aromatic hydrocarbons (PAH), e.g. benzo(a)pyrene (BaP). Though the method was demonstrated to be a convenient way to monitor PAH, the amount adsorbed to the blue rayon depends on the intensity of water stream and the level of PAH. The intensity of water stream was measured by ‘plaster ball’ method, while TWA of PAH in water was measured by a portable sampler using solid phase extraction cartridge. A level of BaP measured by the original blue rayon technique was corrected in this way by the water stream intensity, which correlated well with the TWA of BaP measured by the portable sampler. The improved blue rayon hanging method was applied to several field sites in the Seto Inland Sea of Japan. TWA of BaP ranged from 0.08 to 3.78 ngl−1. These results showed the possibility that the method could be used to evaluate pollution in aquatic environment.  相似文献   

11.
聚丙烯纤维是一种良好的吸油材料。它具有吸油率高和吸油速度快的优点。将它装入油膜采集器,可以吸收漂浮于水面上的同面积的油膜。聚丙烯纤维在吸油的同时,也能吸收一部分水,用3A型的分子筛将水吸出,即可得到吸收的油重。用该方法可以较准确地测定漂浮于水面上的油膜重量和厚度。  相似文献   

12.
A high-pressure serial sampler (HPSS) has been developed to obtain microbial activity data unbiased by decompression during retrieval with the same frequency as used for the measurement of other hydrological parameters. We fitted a commercially available multisampling device with eight pressure-retaining vessels. This device allows the collection of eight 500 ml samples of undecompressed water during the same hydrocast to a depth of 3500 m. The HPSS includes a CTD; therefore the eight sampling depths can be selected using the conventional hydrological parameters. During the retrieval and the incubation period pressure conditions of each sampler are permanently recorded on the surface computer. Incubation is in a temperature-controlled water bath to keep the samples in the natural temperature conditions. During the incubation period, several sub-samples may be successively collected without pressure loss within the culture vessel, allowing time-course experiments. During a stratified period, comparison of microbial production rates simultaneously measured on the decompressed and undecompressed seawater samples collected between 850 and 2000 m depth showed that the deep-sea bacteria were affected by decompression during retrieval.  相似文献   

13.
The Raman scattering and fluorescence spectra were first obtained for the water of sea surface microlayers (SML) of 1 and 0.2 mm thickness (sampled with a Garrett net and a Lapshin capillary sampler, respectively). For reference, samples of water below the SML (from the layer of 0.5 m) were also taken. Substantial differences were found for the values of the normalized intensity of the fluorescence (the number of photons from the volume unit in response to a unit of excitation) between the aqueous humic substances and, presumably, oil hydrocarbons and proteins. Some slight but analyzable differences in the shapes and location of spectral bands were also found. These latter allow one to determine the content of salts and the characteristics of complicated organic compounds in the SML and to compare them to those within the water volume.  相似文献   

14.
摘要:应用有限元软件ANSYS,以与采水器外壳接触的周围水域为研究区域,计算其总阻力系数及最大运动速度。采用相同的数值方法计算了圆球总阻力系数,计算结果与经典实验结论吻合良好,证明了该数值方法的准确性。利用ANSYS软件计算预报采水器或其他类似的海洋仪器在流体中的阻力系数,可指导其尺寸参数设计。  相似文献   

15.
A new, automatic hydrothermal fluid sampler using a shape-memory alloy   总被引:2,自引:0,他引:2  
A new hydrothermal fluid sampler has been developed to provide more maneuverability in underwater operation. The sampler characteristically employs a shape-memory alloy, which senses high temperature and actuates the suction mechanism. A shape-memory alloy is also used to switch the intake valve of the sampler, the intention being to avoid missampling when the inlet is in low temperature water. Prototype samplers were designed to collect the fluids hotter than 80°C. Test sampling was performed at hydrothermal vents (1372–1374 m deep) in the submarine volcano, Suiyo Seamount, Izu-Bonin Arc, northwestern Pacific. Observed fluid temperature was between 138 and 298°C, while the ambient seawater temperature was 3.1°C. Each prototype collected about 100 ml fluid as designed. The magnesium concentration in the samples indicated a seawater content of 47.5–90.8%, which indicates the entrainment of ambient seawater. Microscopic observatinn revealed the occurrence of microorganisms in the sample fluids at a population density of 105 to 106 cells ml−1, which is 2–3 orders of magnitude higher than those in seawater at that depth. The use of the newly developed fluid sampler will greatly facilitate the collection of vent-associated microorganisms, which are of potential biological and biotechnological interest.  相似文献   

16.
A relatively simple and inexpensive distance monitoring system (DMS) was devised to monitor continuously and accurately the position of an underwater camera with an attached pinger relative to the sea floor. Although the precision graphic recorder (PGR) or precision depth recorder (PDR) have hitherto been used to record the pinger to bottom distance, these complicated and expensive instruments are not always expected on all vessels.This newly developed system, which measures with a counting timer the interval between the direct sound pulses generated by a pinger and the bottom echoes, yielded results equal to or better than that of the PGR. The distance information thus obtained was accurate within ±2.5% under good conditions (calm weather and flat and level topography) just above the sea bed. This system simplified the photographing operations and made it possible to obtain a precise and quantitative assessment of the epibenthic fauna with the use of a single camera.The DMS is also applicable for determining the precise location of a bottom water sampler, grab sampler, or other underwater oceanographic equipment as well as that of an underwater camera.A part of this research was supported by science research fund from the Ministry of Education.  相似文献   

17.
Passive sampling could provide the solution to problems associated with costly and time consuming sampling programmes and biomonitoring. Mussels (Mytilus edulis) and Chemcatcher passive sampler were simultaneously analyzed for sequestered pesticides and polychlorinated biphenyls (PCBs) by gas chromatography with mass spectrometry (GC/MSD). The Chemcatcher passive sampler based on a solid phase extraction disc with two types of diffusion-limiting membranes (polyethelene and polysulphone), were also compared. Diuron, atrazine, irgarol and lindane were accumulated in the polysulphone passive sampler in greater concentration than in the mussels or in the other passive samplers with polyethelene limiting-membrane. Mussels can accumulate in their tissue high concentration of non polar compounds such as PCB 52, dieldren and PCB 153; more than the passive sampler with polysulphone membrane. The device with polyethelene limiting membrane has high affinity capacity to concentrate high amount of phenenthrene, dieldrin, PCB 153 and PCB 52, so it acts as a sampler for non-polar compounds. The highest uptake rate of hydrophobic compounds by Chemcatcher was observed for analytes with log octanol-water partition coefficient (KOW) between 4.5 and 7.5. Laboratory-based studies using passive samplers to assess the potential for bioaccumulation could provide robust and reliable information at relatively low cost compared to biomonitoring data. Laboratory data obtained using passive samplers could be related to accumulation under field conditions where field assessments are required.  相似文献   

18.
A new gas-tight isobaric sampler for the collection of hydrothermal fluids venting at the seafloor has been designed, constructed, and tested at a ridge-crest vent site. The new device is constructed of chemically inert titanium, is gas-tight to 450 bar and can be used to sample fluids with temperatures up to 400°C. Compressed gas is used to maintain the sample at seafloor pressure before and during sample withdrawal onboard ship, allowing subsampling without degassing the fluid remaining in the sampler. This feature eliminates the need to collect separate gas-tight and major element samples since a single fluid sample can be analyzed quantitatively for major, trace, semi-volatile, and volatile components. The sampler fill rate is regulated to minimize entrainment of ambient seawater during collection of fluids from environments characterized by low fluid flow such as diffuse hydrothermal vents. In addition to deployment at the ridge-crest, the samplers can be used to collect gas-tight samples from other subseasurface environments such as hydrocarbon seeps, areas of methane-gas hydrate formation, cold seeps associated with serpentinites, regions of groundwater egress to the oceans, and the water column.  相似文献   

19.
We investigated temporal (day‐to‐day and season) and spatial (reach) variability of drift with the aim of guiding sampling protocol for quantifying drift at the whole river or reach scale. Overall, we found aquatic drift density and biomass varied considerably seasonally (CV = 72.9, 88.1) and to a lesser extent spatially (CV = 31.3, 30.7) and from day‐to‐day (CV = 45.2, 39.4). Although spatial and day‐to‐day variation in drift density and biomass were similar, sampling logistics suggest spatial sampling would be more cost‐effective and less time consuming. Drift density and biomass estimated from top samplers was often higher than estimates from samplers near the streambed or mid‐water column. A reliable estimate of mean densities and biomass at a site may require only two samplers— a top sampler and either a middle or bottom sampler. In our study, we calculated that sampling at four sites over 1 or 4 days at one site would be required to obtain a 95% CI within 50% of the mean drift density. Eight sites over 1 or 10 days at one site would be required to achieve a 95% CI within 25% of the mean drift density.  相似文献   

20.
1979年中国科学院海研究所在东海水深28米处进行了一次海上钻探取芯。孔深为30米,取得了可供分析用的岩芯24.60米。室内曾用多种手段对该岩芯进行了综合分析,根据岩性、古生物、古地磁、岩相古地理等对该岩芯进行了地层划分。作者为了探讨热释光技术在海洋沉积地层划分方面的应用,选取了该岩芯  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏