首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A common effective method to reduce the seismic response of liquid storage tanks is to isolate them at base using base-isolation systems. It has been observed that in many earthquakes, the foregoing systems significantly affect on the whole system response reduction. However, in exceptional cases of excitation by long-period shaking, the base-isolation systems could have adverse effects. Such earthquakes could cause tank damage due to excessive liquid sloshing. Therefore, the numerical seismic response of liquid storage tanks isolated by bilinear hysteretic bearing elements is investigated under long-period ground motions in this research. For this purpose, finite shell elements for the tank structure and boundary elements for the liquid region are employed. Subsequently, fluid–structure equations of motion are coupled with governing equation of base-isolation system, to represent the whole system behavior. The governing equations of motion of the whole system are solved by an iterative and step-by-step algorithm to evaluate the response of the whole system to the horizontal component of three ground motions. The variations of seismic shear forces, liquid sloshing heights, and tank wall radial displacements are plotted under various system parameters such as the tank geometry aspect ratio (height to radius), and the flexibility of the isolation system, to critically examine the effects of various system parameters on the effectiveness of the base-isolation systems against long-period ground motions. From these analyses, it may be concluded that with the installation of this type of base-isolation system in liquid tanks, the dynamic response of tanks during seismic ground motions can be considerably reduced. Moreover, in the special case of long-period ground motions, the seismic response of base-isolated tanks may be controlled by the isolation system only at particular conditions of slender and broad tanks. For the case of medium tanks, remarkable attentions would be required to be devoted to the design of base-isolation systems expected to experience long-period ground motions.  相似文献   

2.
A procedure for the dynamic identification of the physical parameters of coupled base isolation systems is developed in the time domain. The isolation systems considered include high damping rubber bearings (HDRB) and low friction sliding bearings (LFSB). A bi‐linear hysteretic model is used alone or in parallel with a viscous damper to describe the behavior of the HDRB system, while a constant Coulomb friction device is used to model the LFSB system. After deriving the analytical dynamical solution for the coupled system under an imposed initial displacement, this is used in combination with the least‐squares method and an iterative procedure to identify the physical parameters of a given base isolation system belonging to the class described by the models considered. Performance and limitations of the proposed procedure are highlighted by numerical applications. The procedure is then applied to a real base isolation system using data from static and dynamic tests performed on a building at Solarino. The results of the proposed identification procedure have been compared to available laboratory data and the agreement is within ±10%. However, the need for improvement both in models and testing procedures also emerges from the numerical applications and results obtained. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
This study presents a nonlinear modelling technique for reinforced concrete (RC) frames retrofitted with metallic yielding devices to predict the seismic response using a computer software OpenSees. The numerical model considers the axial–flexure interaction, shear force–displacement response and the bond-slip characteristics of the frame members. The predicted hysteretic response has been compared with the results of slow-cyclic testing. The validated numerical model is then used to predict the seismic response of a five-story RC frame with soft-story. Nonlinear cyclic pushover and dynamic analyses are conducted to investigate the effectiveness of the proposed retrofitting scheme in enhancing the lateral strength and energy dissipation potential and in controlling the premature failure of the study frame. Analysis results showed significant improvement in the seismic response of RC frames with soft-story using the proposed retrofitting technique.  相似文献   

4.
Passive energy dissipation devices are increasingly implemented in frame structures to improve their performance under seismic loading. Most guidelines for designing this type of system retain the requirements applicable to frames without dampers, and this hinders taking full advantage of the benefits of implementing dampers. Further, assessing the extent of damage suffered by the frame and by the dampers for different levels of seismic hazard is of paramount importance in the framework of performance‐based design. This paper presents an experimental investigation whose objectives are to provide empirical data on the response of reinforced concrete (RC) frames equipped with hysteretic dampers (dynamic response and damage) and to evaluate the need for the frame to form a strong column‐weak beam mechanism and dissipate large amounts of plastic strain energy. To this end, shake‐table tests were conducted on a 2/5‐scale RC frame with hysteretic dampers. The frame was designed only for gravitational loads. The dampers provided lateral strength and stiffness, respectively, three and 12 times greater than those of the frame. The test structure was subjected to a sequence of seismic simulations that represented different levels of seismic hazard. The RC frame showed a performance level of ‘immediate occupancy’, with maximum rotation demands below 20% of the ultimate capacity. The dampers dissipated most of the energy input by the earthquake. It is shown that combining hysteretic dampers with flexible reinforced concrete frames leads to structures with improved seismic performance and that requirements of conventional RC frames (without dampers) can be relieved. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
The purpose of this paper is to describe how the methods and concepts of continuum damage and fracture mechanics can be applied to the modelling of the hysteretic behaviour of Reinforced Concrete (RC) frame members under variable axial loads. A frame member is considered as the assemblage of an elastic beam-column and two inelastic hinges, as in conventional nonlinear analysis of RC frames. As a result of the combination of damage mechanics and standard RC theory, a simplified model of damage is proposed and implemented as a finite element (FE). This new element can be used with any non-linear commercial FE program. The numerical simulation of several experiments, for which data were available in the literature, verifies the accuracy of the model. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

6.
基于能量平衡原理,对多层钢筋混凝土框架结构的地震输入能量的分布及耗散规律进行了研究。选用8条天然地震波和2条人工波,运用Perform-3D软件,对多层钢筋混凝土框架结构模型在7度罕遇地震作用下的弹塑性能量进行数值仿真计算。计算了钢混框架结构在不同地震波下的地震总输入能量、滞回耗能、阻尼耗能以及滞回耗能占总耗能的比例时程,分析了地震能量在各分量中的分布及分配规律;分析了阻尼比和延性比对地震输入能量的影响,确定了滞回耗能随阻尼比和延性比的变化规律;研究了钢筋混凝土框架结构梁柱构造和竖向侧移刚度变化对地震输入能及其分量的影响,确定了多层钢筋混凝土框架结构滞回耗能沿竖向的分布规律及沿横向在框架构件中的分配,研究了框架结构存在薄弱层情况下的滞回耗能的分布规律。揭示了多自由度钢筋混凝土框架结构地震输入能量及其分布规律,可为基于能量平衡原理的抗震设计理论在工程实际中的运用提供有益的参考。  相似文献   

7.
This paper presents the results of a parametric study of self-centering seismic retrofit schemes for reinforced concrete (RC) frame buildings. The self-centering retrofit system features flag-shaped hysteresis and minimal residual deformation. For comparison purpose,an alternate seismic retrofit scheme that uses a bilinear-hysteresis retrofit system such as buckling-restrained braces (BRB) is also considered in this paper. The parametric study was carried out in a single-degree-of-freedom (SDOF) system framework since a multi-story building structure may be idealized as an equivalent SDOF system and investigation of the performance of this equivalent SDOF system can provide insight into the seismic response of the multi-story building. A peak-oriented hysteresis model which can consider the strength and stiffness degradation is used to describe the hysteretic behavior of RC structures. The parametric study involves two key parameters -the strength ratio and elastic stiffness ratio between the seismic retrofit system and the original RC frame. An ensemble of 172 earthquake ground motion records scaled to the design basis earthquake in California with a probability of exceedance of 10% in 50 years was constructed for the simulation-based parametric study. The effectiveness of the two seismic retrofit schemes considered in this study is evaluated in terms of peak displacement ratio,peak acceleration ratio,energy dissipation demand ratio and residual displacement ratio between the SDOF systems with and without retrofit. It is found from this parametric study that RC structures retrofitted with the self-centering retrofit scheme (SCRS) can achieve a seismic performance level comparable to the bilinear-hysteresis retrofit scheme (BHRS) in terms of peak displacement and energy dissipation demand ratio while having negligible residual displacement after earthquake.  相似文献   

8.
For the purpose of estimating the earthquake response, particularly the story drift demand, of reinforced concrete (R/C) buildings with proportional hysteretic dampers, an equivalent single‐degree‐of‐freedom (SDOF) system model is proposed. Especially in the inelastic range, the hysteretic behavior of an R/C main frame strongly differs from that of hysteretic dampers due to strength and stiffness degradation in R/C members. Thus, the proposed model, unlike commonly used single‐spring SDOF system models, differentiates the restoring force characteristics of R/C main frame and hysteretic dampers to explicitly take into account the hysteretic behavior of dampers. To confirm the validity of the proposed model, earthquake responses of a series of frame models and their corresponding equivalent SDOF system models were compared. 5‐ and 10‐story frame models were studied as representative of low‐ and mid‐rise building structures, and different mechanical properties of dampers—yield strength and yield deformation—were included to observe their influence on the effectiveness of the proposed model. The results of the analyses demonstrated a good correspondence between estimated story drift demands using the proposed SDOF system model and those of frame models. Moreover, the proposed model: (i) led to better estimates than those given by a single‐spring SDOF system model, (ii) was capable of estimating the input energy demand and (iii) was capable of estimating the total hysteretic energy and the participation of dampers into the total hysteretic energy dissipation, in most cases. Results, therefore, suggest that the proposed model can be useful in structural design practice. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
An advanced analytical model for high damping rubber bearings   总被引:1,自引:0,他引:1  
Base‐isolation technologies have been developed over the years in attempts to mitigate the effects of earthquakes on structures and potentially vulnerable contents in earthquake prone areas of the world. The high damping rubber bearing (HDRB) is a relatively recent and evolving technology of this kind. The isolator shifts the fundamental period of the base‐isolated structure to a value beyond the range of the plentiful energy‐containing periods of earthquake motions and supplies significant damping to dissipate energy caused by motions. Nevertheless, the highly non‐linear mechanical behaviour of the HDRB is so complex, especially at large strains, that it is difficult to model it analytically. In this paper, an extensive study of experimental tests for identifying the mechanical characteristics of the HDRB is presented. By modifying the Wen's model to include the rate‐dependent effects, an advanced analytical model in an incremental form for the HDRB is also proposed. A very good agreement between the analytical and experimental results has been obtained. It is illustrated that the proposed mathematical model can predict well the mechanical behaviour of HDRB bearings, even at large shear strain. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

10.
To resolve the issue regarding inaccurate prediction of the hysteretic behavior by micro-based numerical analysis for partially-restrained(PR)steel frames with solid reinforced concrete(RC)infill walls,an innovative simplified model of composite compression struts is proposed on the basis of experimental observation on the cracking distribution,load transferring mechanism,and failure modes of RC infill walls filled in PR steel frame.The proposed composite compression struts model for the solid RC infill walls is composed ofαinclined struts and main diagonal struts.Theαinclined struts are used to reflect the part of the lateral force resisted by shear connectors along the frame-wall interface,while the main diagonal struts are introduced to take into account the rest of the lateral force transferred along the diagonal direction due to the complicated interaction between the steel frame and RC infill walls.This study derives appropriate formulas for the effective widths of theαinclined strut and main diagonal strut,respectively.An example of PR steel frame with RC infill walls simulating simulated by the composite inclined compression struts model is illustrated.The maximum lateral strength and the hysteresis curve shape obtained from the proposed composite strut model are in good agreement with those from the test results,and the backbone curve of a PR steel frame with RC infill walls can be predicted precisely when the inter-story drift is within 1%.This simplified model can also predict the structural stiffness and the equivalent viscous damping ratio well when the inter-story drift ratio exceeds 0.5%.  相似文献   

11.
A modified force analogy method (MFAM) is developed to simulate the nonlinear inelastic response of reinforced concrete (RC) structures. Beam–column elements with three different plastic mechanisms are utilized to simulate inelastic response caused by moment and shear force. A multi‐linear hysteretic model is implemented to simulate the nonlinear inelastic response of RC member. The P‐Δ effect of the structure is also addressed in MFAM. Static and dynamic inelastic response of structure, damage condition and failure type for structural element, structural limit state and collapse time can also be simulated using MFAM. Compared with the general algorithm, the MFAM provides less computational time especially in the case of large structural system. It is also easier to be written as computer program. Three test data groups, which include cyclic loading test data of a non‐ductile RC bridge column, a two‐storey RC frame, and dynamic collapse test data of a non‐ductile RC portal frame, are selected to confirm the effectiveness of applying MFAM to simulate the inelastic behaviour of structures. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

12.
本文从能量的观点,利用CANNY程序对普通钢筋混凝土框架结构进行了分析.通过对3种不同框架结构在不同地震动(31条)输入下的能量反应分析,研究了滞回耗能及阻尼耗能与总输入能的关系.针对本文模型的计算结果,给出了滞回耗能与总输入能关系的表达式,并初步探讨了其影响系数.研究表明,滞回耗能及阻尼耗能与总输入能之间有良好的线性关系.  相似文献   

13.
为了对混凝土框架结构的地震破坏机制和抗震性能进行控制,在框架柱中配置高强钢筋,并将纤维增强混凝土(FRC)用于框架结构的预期损伤部位。结构柱中的高强钢筋用来减小结构的残余变形,FRC材料用来增加结构的耗能能力和损伤容限。设计了三个框架,采用动力弹塑性时程分析方法进行分析。研究结果表明,采用高强钢筋提高了结构的整体承载能力,在层间侧移角达到3%之前避免了柱铰的出现(包括底层柱底),并且减小了结构的残余变形;预期损伤部位采用FRC材料能够提高结构的塑性耗能。  相似文献   

14.
针对目前RC框架结构地震易损性分析中整体损伤模型研究的薄弱性以及广泛采用的层间位移角方法不能准确反应结构在地震作用下损伤机理的现状,本文基于现有损伤模型的对比分析,提出了一种较准确反映地震破坏机理同时便于应用的最大变形和滞回耗能非线性组合的双参数损伤模型。以8层RC框架结构为例,进行50条地震波作用下的结构增量动力分析,分别绘制了变形和能量2种单参数模型以及牛荻涛模型和本文模型两种双参数模型的结构损伤曲线与易损性曲线,并进行了模型的对比分析和检验评估。分析结果表明:仅以层间位移角作为结构整体损伤指标会高估结构的抗倒塌性能,仅以能量作为结构整体损伤指标会低估结构损伤的超越概率。本文模型能较好地平衡最大变形和累积损伤对结构损伤的影响程度。  相似文献   

15.
A nonlinear hysteretic model for the response and local damage analyses of reinforced concrete shear frames subject to earthquake excitation is proposed, and, the model is applied to analyse midbroken reinforced concrete (RC) structures due to earthquake loads. Each storey of the shear frame is represented by a Clough and Johnston hysteretic oscillator with degrading elastic fraction of the restoring force. The local damage is numerically quantified in the domain [0,1] using the maximum softening damage indicators which are defined in closed form based on the variation of the eigenfrequency of the local oscillators due to the local stiffness and strength deterioration. The proposed method of response and damage analyses is illustrated using a sample 5 storey shear frame with a weak third storey in stiffness and/or strength subject to sinusoidal and simulated earthquake excitations for which the horizontal component of the ground motion is modeled as a stationary Gaussian stochastic process with Kanai-Tajimi spectrum, multiplied by an envelope function.  相似文献   

16.
This paper presents a new type of structural bracing intended for seismic retrofitting use in framed structures. This special composite brace,termed glass-fiber-reinforced-polymer(GFRP)-tube-confined-concrete composite brace,is comprised of concrete confined by a GFRP tube and an inner steel core for energy dissipation.Together with a contribution from the GFRP-tube confined concrete,the composite brace shows a substantially increased stiffness to control story drift, which is often a preferred feature in seismic retrofitting.An analysis model is established and implemented in a general finite element analysis program-OpenSees,for simulating the load-displacement behavior of the composite brace.Using this model,a parametric study of the hysteretic behavior(energy dissipation,stiffness,ductility and strength)of the composite brace was conducted under static cyclic loading and it was found that the area ratio of steel core to concrete has the greatest influence among all the parameters considered.To demonstrate the application of the composite brace in seismic retrofitting, a three-story nonductile reinforced concrete(RC)frame structure was retrofitted with the composite braces.Pushover analysis and nonlinear time-history analyses of the retrofitted RC frame structure was performed by employing a suite of 20 strong ground motion earthquake records.The analysis results show that the composite braces can effectively reduce the peak seismic responses of the RC frame structure without significantly increasing the base shear demand.  相似文献   

17.
钢筋混凝土结构震后损伤鉴定中,最常见的方式是鉴定者观察房屋破坏现象,根据经验给出震损等级。该方法直观高效,但对鉴定者的专业经验要求较高,且鉴定结果的主观差异较大。对此以RC框架柱为对象,开展了基于震损现象的震损量化鉴定方法研究:在RC框架柱震损现象量化试验基础上给出基于构件骨架曲线特征阶段的震损分级方法;对7个RC框架柱试件进行了改进Park-Ang损伤指数分析,建立了RC框架柱损伤指数-震损分级-震损现象的对应关系;基于RC框架柱的试验结果及典型震害编制了RC框架柱震损图集,并给出了使用图集进行框架柱震损鉴定的流程及方法。使用该方法对2个实际震害中的RC框架柱进行了震损鉴定,可为更加客观以及准确地开展钢筋混凝土结构的震损鉴定提供参考。  相似文献   

18.
基于动力可靠度的隔震结构参数模糊优化   总被引:1,自引:0,他引:1  
分别选取Bouc—Wen和退化Bouc—Wen模型描述隔震层及上部结构滞变回复力,采用虚拟激励法进行隔震结构随机响应分析。用各层最大层间位移响应和累计疲劳损伤指数建立双参数的功能状态方程,用一次二阶矩理论计算隔震结构失效概率。选用一个隔震框架作为数值算例,探讨了低频过滤器、隔震阻尼比和隔震刚度对隔震结构各子系统条件失效概率的影响。建立了隔震结构参数多目标优化模型,用失效概率确定单因素评判的隶属度,并采用最大隶属度法对隔震参数进行模糊优化。  相似文献   

19.
为研究隔震、减震装置非线性恢复力特性对2自由度主次结构体系均方根位移反应的影响规律,以隔震、减震装置微分型恢复力模式的滞回参数为变量,地震地面运动模拟成高斯白噪声过程,利用等效线性化方法得到主体结构和二次结构均方根位移反应的表达式.分析表明,主体结构隔震装置非线性恢复力特征对主、次结构的均方根位移反应的影响占主导地位;隔震、减震装置的恢复力特征产生适度非线性有利于减小主、次结构的均方根位移反应.  相似文献   

20.
地震作用会造成钢筋混凝土框架发生平面和垂直方向的变形,导致其结构受到更大的地震力,加剧损伤程度。形状记忆合金(SMA)材料在外力作用下能够快速恢复变形前形状,降低框架损伤程度,进一步提高框架结构的承载能力和稳定性。基于此,有必要研究形状记忆合金混凝土框架建筑的抗震性能。以某实际工程为例,采用ANSYS软件建立钢筋混凝土框架有限元模型,选取天津地震波、北岭地震波、印度洋地震波及人工地震波作为地震震动输入,记录地震震动下时程结果。研究结果表明,预应力筋断裂后,该结构在地震作用下的滞回曲线为饱满的旗帜形,最大层间位移为1/125,残余变形在±10 mm之间,最高峰值荷载为211 kN,水平承载力较强,表明其自复位性能较高、地震响应效果较优、抗震承载力较强,可以有效提高建筑结构的安全性和可靠性。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号