首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 246 毫秒
1.
Multi‐storey main buildings constructed with a low‐rise podium structure possess some architectural merits but the setback features of such a building complex may lead to seismic response enlargement of the main buildings. This paper explores the possibility of using passive friction dampers to connect the podium structure to the main buildings to prevent their seismic response enlargement without violating the architectural features. A series of shaking table tests were carried out on one 3‐storey and one 12‐storey building models in fully‐separated, rigidly connected, and friction damper‐linked configurations. Four sets of seismic ground motions were selected as inputs to the shaking table. The control competence of two buildings linked with friction damper was evaluated by comparison of their responses with those from fully‐separated and rigidly connected cases. Experimental results showed that unfavourable seismic response amplification did occur in the building complex in the rigidly connected case. By contrast, friction damper showed effectiveness in reducing absolute acceleration and interstorey drift responses of both buildings if friction force level was appropriately applied. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

2.
This paper presents a statistical performance analysis of a semi‐active structural control system for suppressing the vibration response of building structures during strong seismic events. The proposed semi‐active mass damper device consists of a high‐frequency mass damper with large stiffness, and an actively controlled interaction element that connects the mass damper to the structure. Through actively modulating the operating states of the interaction elements according to pre‐specified control logic, vibrational energy in the structure is dissipated in the mass damper device and the vibration of the structure is thus suppressed. The control logic, categorized under active interaction control, is defined directly in physical space by minimizing the inter‐storey drift of the structure to the maximum extent. This semi‐active structural control approach has been shown to be effective in reducing the vibration response of building structures due to specific earthquake ground motions. To further evaluate the control performance, a Monte Carlo simulation of the seismic response of a three‐storey steel‐framed building model equipped with the proposed semi‐active mass damper device is performed based on a large ensemble of artificially generated earthquake ground motions. A procedure for generating code‐compatible artificial earthquake accelerograms is also briefly described. The results obtained clearly demonstrate the effectiveness of the proposed semi‐active mass damper device in controlling vibrations of building structures during large earthquakes. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

3.
Recent major earthquakes around the world have evidenced that research in earthquake engineering must be directed to the vulnerability assessment of existing constructions lacking appropriate seismic resisting characteristics. Their retrofit or replacement should be made in order to reduce vulnerability, and consequent risk, to currently accepted levels. In this work, the efficiency of ductile steel eccentrically-braced systems in the seismic retrofitting of existing reinforced concrete (RC) buildings is studied. The retrofit technique studied consists in a bracing system with an energy dissipation device, designed to dissipate energy by shear deformation. The numerical model was calibrated with cyclic test results on a full-scale structure. The models used for the RC frame and masonry represent their real behavior and influence in the global structural response. The steel bracing system was modeled with strut rigid elements. The model for the energy dissipater device reproduces rigorously the behavior of the shear-link observed in the cyclic tests, namely in terms of shear, drift and energy dissipation. With the calibrated numerical model, a series of non-linear dynamic analyses were performed, for different earthquake input motions, intending to study: the influence of the retrofitting system in the response of bare and infilled structures; the influence of the location and strength of the retrofitting system.  相似文献   

4.
This paper presents the seismic behaviour of a concentrically braced frame system with self‐centring capability, in which a special type of bracing element termed reusable hysteretic damping brace (RHDB) is used. The RHDB is a passive energy dissipation device with its core energy‐dissipating component made of superelastic Nitinol wires. Compared with conventional bracing in steel structures, RHDB has a few prominent performance characteristics: damage free under frequent and design basis earthquakes in earthquake prone areas; minimal residual drifts due to the self‐centring capability of RHDB frame; and ability to survive several strong earthquakes without the need for repair or replacement. This paper also includes a brief discussion of the RHDB's mechanical configuration and analytical model for RHDB. The seismic performance study of RHDB frame was carried out through a non‐linear time history analysis of 3‐storey and 6‐storey RHDB frame buildings subjected to two suites of 20 earthquake ground motions. The analysis results were compared with buckling‐restrained brace (BRB) frames. This study shows that RHDB frame has a potential to outperform BRB frames by eliminating the residual drift problem. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

5.
Upgrading noncode conforming buildings to mitigate seismic induced damages is important in moderate to high seismic hazard regions. The damage, can be mitigated by using conventional (e.g. FRP wrapping) and emerging (e.g. smart structures) retrofit techniques. A model for the structure to be retrofitted should include relevant performance indicators. This paper proposes a variable stiffness smart structure device known as the Smart Spring to be integrated on building structures to mitigate seismic induced damage. The variable stiffness capability is of importance to structures that exhibit vertical (e.g. soft storey) irregularities and to meet different performance levels under seismic excitation. To demonstrate the utility of the proposed retrofitting technique, a four‐storey steel building is modelled in MATLAB and appropriate performance indicators are chosen. Various return period seismic hazards are generated from past earthquake event records to predict the structure's performance. The performance improvement because of the retrofitting of building structures using the variable stiffness device is presented. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
This study describes the seismic performance of an existing five storey reinforced concrete building which represents the typical properties of low-rise non-ductile buildings in Turkey. The effectiveness of shear walls and the steel bracings in retrofitting the building was examined through nonlinear static and dynamic analyses. By using the nonlinear static analysis, retrofitted buildings seismic performances under lateral seismic load were compared with each other. Moreover, the performance points and response levels of the existing and retrofitting cases were determined by way of the capacity-spectrum method described in ATC-40 (1996). For the nonlinear dynamic analysis the records were selected torepresent wide ranges of duration and frequency content. Considering the change in the stiffness and the energy dissipation capacities, the performance of the existing and retrofitted buildings were evaluated in terms of story drifts and damage states. It was found that each earthquake record exhibited its own peculiarities, dictated by frequency content, duration, sequence of peaks and their amplitude. The seismic performance of retrofitted buildings resulted in lower displacements and higher energy dissipation capacity depending mainly on the properties of the ground motions and the retrofitting strategies. Moreover, severe structural damage (irreparable or collapse) was observed for the existing building. However, buildings with retrofit alternatives exhibited lower damage levels changing from no damage to irreparable damage states.  相似文献   

7.
This study explores seismic performance of steel frame buildings with SMA-based self-centering bracing systems using a probabilistic approach. The self-centering bracing system described in this study relies on superelastic response of large-diameter cables. The bracing systems is designed such that the SMA cables are always stressed in tension. A four-story steel frame building characterized until collapse in previous research is selected as a case-study building. The selected steel frame building is designed with SMA bracing systems considering various design parameters for SMA braces. Numerical models of these buildings are developed by taking into account the ultimate state of structural components and SMA braces as well as the effect of gravity frames on lateral load resistance. Nonlinear static analyses are conducted to assess the seismic characteristics of each frame and to examine the effect of SMA brace failure on the seismic load carrying capacity of SMA-braced frames. Incremental dynamic analyses (IDA) are performed to compute seismic response of the designed frames at various seismic intensity levels. The results of IDA are used to develop probabilistic seismic demand models for peak inter-story and residual inter-story drifts. Seismic demand hazard curves of peak and residual inter-story drifts are generated by convolving the ground motion hazard with the probabilistic seismic demand models. Results show that steel frames designed with SMA bracing systems provide considerably lower probability of reaching at a damage state level associated with residual drifts compared to a similarly designed steel moment resisting frame, especially for seismic events with high return periods. This indicates reduced risks for the demolition and collapse due to excessive residual drifts for SMA braced steel frames.  相似文献   

8.
It is well known that the axial load plays an important role in the evaluation of the structural capacity of RC columns. In existing buildings this problem can be even more significant than in new ones, since the material can easily present poor mechanical properties. The paper is aimed at the investigation of the role of the axial load variation on the seismic performance of RC columns of a case-study, i.e. a doubly symmetric 4-storey RC building. The effects of the axial load variation have been checked on the first storey columns, by comparing the seismic response, measured in terms of chord rotation and shear force, with the corresponding capacity. The sensitivity of the seismic performance to the axial load is evaluated with special attention on the type of analysis adopted to determine the seismic response and on considering a wide range of values for the concrete strength. The study points out a non-negligible effect of the axial load variation on the seismic response of the case-study building, especially when combined to concrete strength variability.  相似文献   

9.
Multi‐storey buildings made of cross‐laminated timber panels (X‐lam) are becoming a stronger and economically valid alternative in Europe compared with traditional masonry or concrete buildings. During the design process of these multi‐storey buildings, also their earthquake behaviour has to be addressed, especially in seismic‐prone areas such as Italy. However, limited knowledge on the seismic performance is available for this innovative massive timber product. On the basis of extensive testing series comprising monotonic and reversed cyclic tests on X‐lam panels, a pseudodynamic test on a one‐storey X‐lam specimen and 1D shaking table tests on a full‐scale three‐storey specimen, a full‐scale seven‐storey building was designed according to the European seismic standard Eurocode 8 and subjected to earthquake loading on a 3D shaking table. The building was designed with a preliminary action reduction factor of three that had been derived from the experimental results on the three‐storey building. The outcomes of this comprehensive research project called ‘SOFIE – Sistema Costruttivo Fiemme’ proved the suitability of multi‐storey X‐lam structures for earthquake‐prone regions. The buildings demonstrated self‐centring capabilities and high stiffness combined with sufficient ductility to avoid brittle failures. The tests provided useful information for the seismic design with force‐based methods as defined in Eurocode 8, that is, a preliminary experimentally based action reduction factor of three was confirmed. Valid, ductile joint assemblies were developed, and their importance for the energy dissipation in buildings with rigid X‐lam panels became evident. The seven‐storey building showed relatively high accelerations in the upper storeys, which could lead to secondary damage and which have to be addressed in future research. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
The seismic response spectrum defines the amplitude of the load, but it does not specify the number of cycles for which the load must be resisted by the structure. The amplitude by itself is not sufficient to evaluate the seismic resistance of a structure, because the structure's strength, stiffness and energy‐dissipation capacity reduce with an increase in the number of load cycles. This paper presents a cyclic‐demand spectrum, which, in conjunction with the amplitude spectrum, provides a more complete definition of the seismic load, hence a way to consider the degradation in strength, stiffness and energy‐dissipation capacity in a rational manner. Similarly to three amplitude parameters (peak ground acceleration, peak ground velocity, and peak ground displacement), three cyclic‐demand parameters are introduced for stiff, moderately stiff, and flexible systems. A design example is presented to illustrate the use of the cyclic‐demand spectrum. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

11.
摩擦消能支撑钢框架结构的弹塑性地震反应时程分析   总被引:1,自引:0,他引:1  
本文分析了摩擦消能支撑及框架主体结构弹塑性本构关系,并给出了动力时程分析的计算方法。同时,对六层钢框架模型做了各种工况下的地震反应时程分析。结果表明,摩擦消能支撑钢框架(FEDBF)比抗弯钢框架(MRF)的地震作用明显降低,尤其在强震作用下效果更加明显。  相似文献   

12.
This paper investigates the seismic response of multi‐storey cross‐laminated timber (CLT) buildings and its relationship with salient ground‐motion and building characteristics. Attention is given to the effects of earthquake frequency content on the inelastic deformation demands of platform CLT walled structures. The response of a set of 60 CLT buildings of varying number of storeys and panel fragmentation levels representative of a wide range of structural configurations subjected to 1656 real earthquake records is examined. It is shown that, besides salient structural parameters like panel aspect ratio, design behaviour factor, and density of joints, the frequency content of the earthquake action as characterized by its mean period has a paramount importance on the level of nonlinear deformations attained by CLT structures. Moreover, the evolution of drifts as a function of building to ground‐motion periods ratio is different for low‐ and high‐rise buildings. Accordingly, nonlinear regression models are developed for estimating the global and interstorey drifts demands on multi‐storey CLT buildings. Finally, the significance of the results is highlighted with reference to European seismic design procedures and recent assessment proposals.  相似文献   

13.
This article examines the use of rocking steel braced frames for the retrofit of existing seismically deficient steel building structures. Rocking is also used to achieve superior seismic performance to reduce repair costs and disruption time after earthquakes. The study focuses on low‐rise buildings for which re‐centring is solely provided by gravity loads rather than added post‐tensioning elements. Friction energy dissipative (ED) devices are used to control drifts. The system is applied to 2‐storey and 3‐storey structures located in 2 seismically active regions of Canada. Firm ground and soft soil conditions are considered. The seismic performance of the retrofit scheme is evaluated using nonlinear dynamic analysis and ASCE 41‐13. For all structures, rocking permits to achieve immediate occupancy performance under 2% in 50 years seismic hazard if the braces and their connections at the building's top storeys are strengthened to resist amplified forces due to higher mode response. Base shears are also increased due to higher modes. Impact at column bases upon rocking induces magnified column forces and vertical response in the gravity system. Friction ED is found more effective for drift control than systems with ring springs or bars yielding in tension. Drifts are sufficiently small to achieve position retention performance for most nonstructural components. Horizontal accelerations are generally lower than predicted from ASCE 41 for regular nonrocking structures. Vertical accelerations in the gravity framing directly connected to the rocking frame are however higher than those predicted for ordinary structures. Vertical ground motions have limited effect on frame response.  相似文献   

14.
Considerable effort has been devoted to develop passive and active methods for reducing structural response under seismic excitations. Passive control approaches have already found application in practice. Active control methods, on the other hand, are being vigorously examined for application to civil structures. This paper investigates the application of active and semi-active control schemes to structures subjected to seismic excitations, and it focuses on the use of the sliding-mode control approach for the development of the control algorithms. The possibility of control redundancy with respect to the number of sliding constraints is taken into account in the controller design. Several sets of numerical results are obtained for a realistic 10-storey shear building, subjected to earthquake-induced ground motions and controlled by active or semi-active control schemes. It is observed that both active and semi-active control schemes can be used to reduce the dynamic response. Active control performs very effectively in reducing the structural response, but the required control force values can be quite large to limit its practical application in the case of large and massive buildings. Active regulation of linear viscous dampers was found unnecessary for this type of structural system, as it did not induce any significantly more reduction in the response than the dampers acting passively. On the other hand, it is shown that active regulation of stiffness can be used with advantage to reduce the response. © 1997 by John Wiley & Sons, Ltd.  相似文献   

15.
Open Ground Storey(OGS) framed buildings where the ground storey is kept open without infill walls, mainly to facilitate parking, is increasing commonly in urban areas. However, vulnerability of this type of buildings has been exposed in past earthquakes. OGS buildings are conventionally designed by a bare frame analysis that ignores the stiffness of the infill walls present in the upper storeys, but doing so underestimates the inter-storey drift(ISD) and thereby the force demand in the ground storey columns. Therefore, a multiplication factor(MF) is introduced in various international codes to estimate the design forces(bending moments and shear forces) in the ground storey columns. This study focuses on the seismic performance of typical OGS buildings designed by means of MFs. The probabilistic seismic demand models, fragility curves, reliability and cost indices for various frame models including bare frames and fully infilled frames are developed. It is found that the MF scheme suggested by the Israel code is better than other international codes in terms of reliability and cost.  相似文献   

16.
The present paper investigates the seismic reliability of the application of buckling restrained braces (BRBs) for seismic retrofitting of steel moment resisting framed buildings through fragility analysis. Samples of regular three‐storey and eight‐storey steel moment resisting frames were designed with lateral stiffness insufficient to comply with the code drift limitations imposed for steel moment resisting frame systems in earthquake‐prone regions. The frames were then retrofitted with concentrically chevron conventional braces and BRBs. To obtain robust estimators of the seismic reliability, a database including a wide range of natural earthquake ground motion records with markedly different characteristics was used in the fragility analysis. Nonlinear time history analyses were utilized to analyze the structures subjected to these earthquake records. The improvement of seismic reliability achieved through the use of conventional braces and BRBs was evaluated by comparing the fragility curves of the three‐storey and eight‐storey model frames before and after retrofits, considering the probabilities of four distinct damage states. Moreover, the feasibility of mitigating the seismic response of moment resisting steel structures by using conventional braces and BRBs was determined through seismic risk analysis. The results obtained indicate that both conventional braces and especially BRBs improve significantly the seismic behavior of the original building by increasing the median values of the structural fragility curves and reducing the probabilities of exceedance of each damage state. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
Previous studies have demonstrated the good performance of friction dampers in symmetric frame structures subjected to earthquake excitation. This paper examines their effectiveness in asymmetric structures where lateral-torsional coupling characterizes the behaviour. A parametric study is first performed employing an idealized single-storey structure; this is followed by the example of a three-dimensional 5-storey prototype structure equipped with friction dampers. The parametric results show that it is necessary to tune the friction damped braces with respect to both the stiffness of the braces and the slip load of the devices. For properly tuned structures, maximum response for all magnitudes of eccentricity between the centres of stiffness and mass is reduced to levels equal to or less than that of the corresponding symmetric structure. Compared to this prediction, the prototype structure with friction damped bracing exhibits the desired improvement in performance; namely, the devices slip at all storey levels while the frames remain elastic.  相似文献   

18.
为研究钢筋砼摩擦耗能支撑框架结构的动力反应性能 ,对其中的摩擦耗能器单元和框架杆单元的单元刚度和力学模型做了分析。钢筋砼摩擦耗能支撑单元由支撑杆单元和钢板—橡胶摩擦耗能器单元组成 ,支撑单元可取空间杆单元 ,摩擦耗能器单元为平面应力矩形单元。摩擦耗能器单元的剪切恢复力曲线为理想的弹塑性曲线 ,根据耗能器单元的力学模型 ,可确定其在每一时刻的刚度 ;框架结构空间杆单元的恢复力模型采用双线型模型 ,根据杆单元的力学模型 ,可确定其在每一时刻的刚度。并利用所编制的程序对十层单榀两跨空间普通框架和摩擦耗能支撑框架在地震作用下进行了弹塑性反应时程分析 ,结果表明耗能支撑框架的顶层最大位移明显小于普通框架  相似文献   

19.
The results of experimental tests carried out on reinforced concrete (RC) full‐scale 2‐storey 2‐bays framed buildings are presented. The unretrofitted frame was designed for gravity loads only and without seismic details; such frame was assumed as a benchmark system in this study. A similar RC frame was retrofitted with buckling‐restrained braces (BRBs). The earthquake structural performance of both prototypes was investigated experimentally using displacement‐controlled pushover static and cyclic lateral loads. Modal response properties of the prototypes were also determined before and after the occurrence of structural damage. The results of the dynamic response analyses were utilized to assess the existing design rules for the estimation of the elastic and inelastic period of vibrations. Similarly, the values of equivalent damping were compared with code‐base relationships. It was found that the existing formulations need major revisions when they are used to predict the structural response of as‐built RC framed buildings. The equivalent damping ratio ξeq was augmented by more than 50% when the BRBs was employed as bracing system. For the retrofitted frame, the overstrength Ω and the ductility µ are 1.6 and 4.1, respectively; the estimated R‐factor is 6.5. The use of BRBs is thus a viable means to enhance efficiently the lateral stiffness and strength, the energy absorption and dissipation capacity of the existing RC substandard frame buildings. The foundation systems and the existing members of the superstructure are generally not overstressed as the seismic demand imposed on them can be controlled by the axial stiffness and the yielding force of the BRBs. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
A procedure is presented to predict the storey where plastic drift dominates in two‐storey buildings under strong ground motion. The procedure utilizes the yield strength and the mass of each storey as well as the peak ground acceleration. The procedure is based on two different assumptions: (1) the seismic force distribution is of inverted triangular form and (2) the rigid‐plastic model represents the system. The first and the second assumptions, respectively, lead to lower and upper estimates of the base shear coefficient under which the drift of the first storey exceeds that of the second storey. The efficiency of the procedure is verified by dynamic response analyses using elasto‐plastic model. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号