首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 562 毫秒
1.
For the first time after the finalisation of the European Norm for seismic design of buildings (Eurocode 8 – EC8),the performance of RC buildings designed with this code is evaluated through systematic nonlinear analyses. Regular 4-, 8- or 12-storey RC frames are designed for a PGA of 0.2 or 0.4 g and to one of the three alternative ductility classes in EC8. As the Eurocodes are meant to replace soon existing national codes, design and performance is also compared to that of similar frames designed with the 2000 Greek national codes. The performance of alternative designs under the life-safety (475 years) and the damage limitation (95 years) earthquakes is evaluated through nonlinear seismic response analyses. The large difference in material quantities and detailing of the alternative designs does not translate into large differences in performance. Design for either Ductility Class High (H) or Medium (M) of EC8 is much more cost-effective than design for Ductility Class Low (L), even in moderate seismicity. It is also much more cost-effective than design to the 2000 Greek national codes.  相似文献   

2.
剪切型结构的抗震强度折减系数研究   总被引:1,自引:0,他引:1  
为了研究剪切型结构抗震强度需求的变化规律,本文基于单自由度体系的非线性时程分析,研究了不同场地条件下延性折减系数与位移延性系数和结构自振周期的关系;采用修正等效单自由度体系位移延性折减系数的方法,研究了剪切型多自由度体系的延性折减系数;以基于中国建筑抗震规范设计的代表不同抗震能力要求的RC框架结构为分析对象,通过静力弹塑性分析,研究了RC框架结构的体系超强能力。分析结果表明场地类别、位移延性水准和结构振动周期对单自由度体系的延性折减系数有显著的影响;多自由度体系的抗震延性折减系数明显比其相应的等效单自由度体系的抗震延性折减系数小;RC框架结构的超强系数一般随结构楼层数的增加而减小,随抗震设防烈度的增大而减小,内框架的超强系数比边框架的超强系数大。  相似文献   

3.
The paper presents the results of a research study concerning the seismic response and design of r/c frames with overstrength discontinuities in elevation. The discontinuities are obtained assigning overstrengths either to the beams or to the columns of a “regular frame” (assumed as reference). Two “regular frames” are designed: one according to the Eurocode 8 (EC8) medium ductility class (DCM) rules and the other one according to the EC8 high ductility class (DCH) rules. For all frames the criteria of vertical strength irregularity of many international seismic codes are applied. Non linear static and dynamic analyses are performed; mechanical non linearity is concentrated at the element ends. These analyses are carried out according to EC8 provisions: for non linear static analysis the N2 method is applied; in the case of non linear time-history analyses, seven real earthquakes, selected in order to fit on average the elastic design spectrum, are used as input. The seismic response of frames characterised by the assigned overstrength is not very different with respect to the “regular frame” one; furthermore all the frames satisfy the Ultimate Limit State, verified by the application of non linear static and dynamic analyses. This demonstrates that the sensitivity of frames, designed according to EC8 medium and high ductility classes, to overstrength vertical variations is low. Consequently, international code provisions on vertical strength regularity should be reviewed.  相似文献   

4.
5.
A computer program is developed to test the influence of the structural overstrength to calibrate seismic codes. The program automatically performs an iterative design-evaluation process to calibrate the seismic code. A numerical example is performed in order to test the different approaches. The virtual simulation shows that the force reduction factor cannot be directly deduced from building performance in past earthquakes. This custom of deducing the force reduction factor from the building performance under past earthquakes artificially increases the ratios elastic spectrum to design spectrum due to the design structural overstrength. The similitude of the simulation with the historical calibration of the design spectrum in the seismic codes in the United States of America (USA) is evident.  相似文献   

6.
The potential of post‐tensioned self‐centering moment‐resisting frames (SC‐MRFs) and viscous dampers to reduce the economic seismic losses in steel buildings is evaluated. The evaluation is based on a prototype steel building designed using four different seismic‐resistant frames: (i) conventional moment resisting frames (MRFs); (ii) MRFs with viscous dampers; (iii) SC‐MRFs; or (iv) SC‐MRFs with viscous dampers. All frames are designed according to Eurocode 8 and have the same column/beam cross sections and similar periods of vibration. Viscous dampers are designed to reduce the peak story drift under the design basis earthquake (DBE) from 1.8% to 1.2%. Losses are estimated by developing vulnerability functions according to the FEMA P‐58 methodology, which considers uncertainties in earthquake ground motion, structural response, and repair costs. Both the probability of collapse and the probability of demolition because of excessive residual story drifts are taken into account. Incremental dynamic analyses are conducted using models capable to simulate all limit states up to collapse. A parametric study on the effect of the residual story drift threshold beyond which is less expensive to rebuild a structure than to repair is also conducted. It is shown that viscous dampers are more effective than post‐tensioning for seismic intensities equal or lower than the maximum considered earthquake (MCE). Post‐tensioning is effective in reducing repair costs only for seismic intensities higher than the DBE. The paper also highlights the effectiveness of combining post‐tensioning and supplemental viscous damping by showing that the SC‐MRF with viscous dampers achieves significant repair cost reductions compared to the conventional MRF. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

7.
In this paper, a practical method is developed for performance‐based design of RC structures subjected to seismic excitations. More efficient design is obtained by redistributing material from strong to weak parts of a structure until a state of uniform deformation or damage prevails. By applying the design algorithm on 5, 10 and 15‐storey RC frames, the efficiency of the proposed method is initially demonstrated for specific synthetic and real seismic excitations. The results indicate that, for similar structural weight, designed structures experience up to 30% less global damage compared with code‐based design frames. The method is then developed to consider multiple performance objectives and deal with seismic design of RC structures for a design spectrum. The results show that the proposed method is very efficient at controlling performance parameters and improving structural behaviour of RC frames. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

8.
The overstrength and ductility due to redistribution of internal forces are being investigated for three bay multi-storey reinforced concrete plane frames, using non-linear push-over analysis. These frames are designed to resist gravity loads, wind loads and a notional horizontal load in accordance with the British code BS 8110, which does not have any special provision for seismic loads. The results show that the overstrength factors for the three-, six- and ten-storey frames are respectively, 7·5, 5·6 and 2·2 times the design lateral loads, whereas, the ductility factors for the three frames are similar, and slightly greater than 2. These values yield a response modification factor of 18·0, 12·2 and 4·7 for the three-, six- and ten-storey frames, respectively. The effect of infill walls on the response modification factor is also being investigated, and a suitable response modification factor for assessing the vulnerability of reinforced concrete frames of about 10 storeys high is recommended. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

9.
This paper presents the main results of the evaluation of residual inter‐story drift demands in typical moment‐resisting steel buildings designed accordingly to the Mexican design practice when subjected to narrow‐band earthquake ground motions. Analytical 2D‐framed models representative of the study‐case buildings were subjected to a set of 30 narrow‐band earthquake ground motions recorded on stations placed in soft‐soil sites of Mexico City, where most significant structural damage was found in buildings as a consequence of the 1985 Michoacan earthquake, and scaled to reach several levels of intensity to perform incremental dynamic analyses. Thus, results were statistically processed to obtain hazard curves of peak (maximum) and residual drift demands for each frame model. It is shown that the study‐case frames might exhibit maximum residual inter‐story drift demands in excess of 0.5%, which is perceptible for building's occupants and could cause human discomfort, for a mean annual rate of exceedance associated to peak inter‐story drift demands of about 3%, which is the limiting drift to avoid collapse prescribed in the 2004 Mexico City Seismic Design Provisions. The influence of a member's post‐yield stiffness ratio and material overstrength in the evaluation of maximum residual inter‐story drift demands is also discussed. Finally, this study introduces response transformation factors, Tp, that allow establishing residual drift limits compatible with the same mean annual rate of exceedance of peak inter‐story drift limits for future seismic design/evaluation criteria that take into account both drift demands for assessing a building's seismic performance. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
Traditional seismic design, like the one adopted in Eurocode 8 (EC8), is force‐based and examining a single level of seismic action. In order to provide improved control of structural damage for different levels of seismic action, the new fib Model Code 2010 (MC2010) includes a fully fledged displacement‐based and performance‐based seismic design methodology. However, the level of complexity and computational effort of the MC2010 methodology is significantly increased. Hence, the use of automated optimization techniques for obtaining cost‐effective design solutions becomes appealing if not necessary. This study employs genetic algorithms to derive and compare optimum seismic design solutions of reinforced concrete frames according to EC8 and MC2010. This is important because MC2010 is meant to serve as a basis for future seismic design codes. It is found that MC2010 drives to more cost‐effective solutions than EC8 for regions of low seismicity and better or similar costs for regions of moderate seismicity. For high‐seismicity regions, MC2010 may yield similar or increased structural costs. This depends strongly on the provisions adopted for selecting the set of ground motions. In all cases, MC2010 provides enhanced control of structural damage. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
Self‐centering reinforced concrete frames are developed as an alternative of traditional seismic force‐resisting systems with better seismic performance and re‐centering capability. This paper presents an experimental and computational study on the seismic performance of self‐centering reinforced concrete frames. A 1/2‐scale model of a two‐story self‐centering reinforced concrete frame model was designed and tested on the shaking table in State Key Laboratory of Disaster Reduction in Civil Engineering at Tongji University to evaluate the seismic behavior of the structure. A structural analysis model, including detailed modeling of beam–column joints, column–base joints, and prestressed tendons, was constructed in the nonlinear dynamic modeling software OpenSEES. Agreements between test results and numerical solutions indicate that the designed reinforced concrete frame has satisfactory seismic performance and self‐centering capacity subjected to earthquakes; the self‐centering structures can undergo large rocking with minor residual displacement after the earthquake excitations; the proposed analysis procedure can be applied in simulating the seismic performance of self‐centering reinforced concrete frames. To achieve a more comprehensive evaluation on the performance of self‐centering structures, research on energy dissipation devices in the system is expected. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
The quality of construction is one of the main factors that affect the seismic vulnerability of structures. The damage observations of modern buildings after almost all recent earthquakes report cases of poor quality of materials, inadequate detailing of reinforcement and absence of capacity design principles. Looking at the modern codes for seismic design, which rely on high behaviour factor supplies, the assessment of the effects of poor quality of execution in otherwise well‐conceived and well‐designed structures becomes an important problem. This paper presents an experiment‐based estimation of the seismic response of a cast‐in‐situ one‐storey industrial reinforced concrete frame designed according to Eurocodes. The influence of the quality of construction is estimated by consideration of two models of the experimental prototype: a structure erected under strict measures for control of the quality of execution, and a structure erected with normal measures for control of the quality of execution which resulted in significant deficiencies in the practical arrangement of the reinforcement. On the basis of the experimental data the ductility and behaviour factor supplies of the two structures are estimated. Quantitative expressions for the influence of the quality of construction on the first yield displacement, ultimate storey displacement, maximum base‐shear force and behaviour factor supply are provided. Recommendations for the refinement of modern seismic design codes, particularly Eurocode 8, to take into account the quality of construction are given. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

13.
This paper assesses the influence of cyclic and in‐cycle degradation on seismic drift demands in moment‐resisting steel frames (MRF) designed to Eurocode 8. The structural characteristics, ground motion frequency content, and level of inelasticity are the primary parameters considered. A set of single‐degree‐of‐freedom (SDOF) systems, subjected to varying levels of inelastic demands, is initially investigated followed by an extensive study on multi‐storey frames. The latter comprises a large number of incremental dynamic analyses (IDA) on 12 frames modelled with or without consideration of degradation effects. A suite of 56 far‐field ground motion records, appropriately scaled to simulate 4 levels of inelastic demand, is employed for the IDA. Characteristic results from a detailed parametric investigation show that maximum response in terms of global and inter‐storey drifts is notably affected by degradation phenomena, in addition to the earthquake frequency content and the scaled inelastic demands. Consistently, both SDOF and frame systems with fundamental periods shorter than the mean period of ground motion can experience higher lateral strength demands and seismic drifts than those of non‐degrading counterparts in the same period range. Also, degrading multi‐storey frames can exhibit distinctly different plastic mechanisms with concentration of drifts at lower levels. Importantly, degrading systems might reach a “near‐collapse” limit state at ductility demand levels comparable to or lower than the assumed design behaviour factor, a result with direct consequences on optimised design situations where over‐strength would be minimal. Finally, the implications of the findings with respect to design‐level limit states are discussed.  相似文献   

14.
耗能梁段作为偏心支撑结构的耗能元件,在大震作用下通过弹塑性变形吸收地震能量,保护主体结构处于弹性受力状态。现行规范基于强度的设计理论,为了保证耗能梁段进入塑性或破坏,梁柱构件需要进行放大内力设计,导致截面过大,而且基于强度的设计方法很难保证结构的整体破坏状态。目前,抗震设计越来越重视基于性能的设计思想,该方法能够评估结构的弹塑性反应。对于高强钢组合偏心支撑,其中耗能梁段和支撑采用Q345钢,框架梁柱采用Q460或者Q690高强度钢材,高强钢不仅带来良好的经济效益,而且能够推广高强钢在抗震设防区的应用。利用基于性能设计方法设计了4种不同形式的高强钢组合偏心支撑钢框架,包括K形、Y形、V形和D形,考虑4层、8层、12层和16层的影响。通过Pushover分析和非线性时程分析评估该结构的抗震性能,研究结果表明:4种形式的高强钢组合偏心支撑钢框架具有类似的抗震性能,在罕遇地震作用下,几乎所有耗能梁段均参与耗能,而且层间侧移与耗能梁段转角沿高度分布较为均匀。其中:D形偏心支撑具有最大的抗侧刚度,但延性较差,而Y形偏心支撑的抗侧刚度最弱,但延性最佳。  相似文献   

15.
This paper evaluates the hysteretic behavior of an innovative compressed elastomer structural damper and its applicability to seismic‐resistant design of steel moment‐resisting frames (MRFs). The damper is constructed by precompressing a high‐damping elastomeric material into steel tubes. This innovative construction results in viscous‐like damping under small strains and friction‐like damping under large strains. A rate‐dependent hysteretic model for the compressed elastomer damper, formed from a parallel combination of a modified Bouc–Wen model and a non‐linear dashpot is presented. The model is calibrated using test data obtained under sinusoidal loading at different amplitudes and frequencies. This model is incorporated in the OpenSees [17] computer program for use in seismic response analyses of steel MRF buildings with compressed elastomer dampers. A simplified design procedure was used to design seven different systems of steel MRFs combined with compressed elastomer dampers in which the properties of the MRFs and dampers were varied. The combined systems are designed to achieve performance, which is similar to or better than the performance of conventional steel MRFs designed according to current seismic codes. Based on the results of nonlinear seismic response analyses, under both the design basis earthquake and the maximum considered earthquake, target properties for a new generation of compressed elastomer dampers are defined. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
During a severe earthquake, steel moment resisting frames are expected to experience significant inelastic deformation in their members and joints. This behaviour is dependent upon several design parameters such as member sizes, frame's overstrength, member deformation capacities and the detailing of components. In this study, the influence of such aspects on the inelastic response of frames is investigated. Inelastic static and dynamic analyses were performed on four frames of different designs for a typical six-storey building. The frames were designed and detailed in accordance with current North American code requirements. The computed response of each frame was compared with the behaviour expected by the codes. Recommendations for a design procedure are suggested for improving the structural performance of low-rise steel frames subjected to strong earthquake excitation.  相似文献   

17.
Buckling restrained braces (BRBs) are very effective in dissipating energy through stable tension–compression hysteretic cycles and have been successfully experimented in the seismic protection of buildings. Their behavior has been studied extensively in the last decades and today the level of performance guaranteed by these devices and the technological constrains that have to be fulfilled to optimize their behavior are well known. Furthermore, several companies in the world have developed their own BRBs and are now producing them. In spite of this, many seismic codes (for instance, the EuroCode 8) do not stipulate provisions for the design and construction of earthquake‐resistant structures equipped with BRBs. This discourages the structural engineering community from using these devices and seriously limits their use in structural applications. In this paper a procedure for the seismic design of steel frames equipped with BRBs is proposed. Furthermore, the paper presents a numerical investigation aimed at validating this design procedure and proposing the value of the behavior factor q that should be used for this structural type. To this end, a set of frames with BRBs is first designed by means of several values of q. Then, the obtained frames are subjected to a set of accelerograms compatible with the elastic response spectrum considered in design. The seismic response of the frames is determined by nonlinear dynamic analysis and represented in terms of the ductility demand of BRBs and the internal force demand of nondissipative members (beams and columns). Finally, the largest value of q that leads to acceptable seismic performance of the analyzed frames is assumed as adequate. The value of q is given in the paper as a continuous function of the assumed ductility capacity of the BRBs. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
A multi‐level seismic vulnerability assessment of reinforced concrete moment frame buildings located in moderate seismic zones (0.25g) is performed on a set of ductile versions of low‐ to mid‐rise two‐dimensional moment frames. The study is illustrated through application to comparative trial designs of two (4‐ and 8‐story) buildings adopting both space‐ and perimeter‐framed approaches. All frames are dimensioned as per the emerging version of the seismic design code in Egypt. These new seismic provisions are in line with current European norms for seismic design of buildings. Code‐compliant designs (CCD), as well as a proposed modified code design relaxing design drift demands for the investigated buildings, are examined to test their effectiveness and reliability. Applying nonlinear inelastic incremental dynamic analyses, fragility curves (FC) for the frames are developed corresponding to various code‐specified performance levels. Code preset lower and upper bounds on design acceleration and drift, respectively, are also addressed along with their implications, if imposed, on the frames seismic performance and vulnerability. Annual spectral acceleration hazard curves for the case study frames are also generated. Estimates for mean annual frequency (MAF) of exceeding various performance levels are then computed through an integration process of the data resulting from the FC with the site hazard curves. The study demonstrates that the proposed design procedure relaxing design drift demands delivers more economic building designs relative to CCDs, yet without risking the global safety of the structure. The relaxed design technique suggested herein, even though scoring higher, as expected by intuition, MAF of exceeding various code‐limiting performance levels expressed in terms of interstory drift ratios, still guarantees a reasonably acceptable actual margin against violating code limits for such levels. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
This paper summarizes results of a comprehensive analytical study aimed at evaluating the amplitude and heightwise distribution of residual drift demands in multi‐storey moment‐resisting frames after earthquake excitation. For that purpose, a family of 12 one‐bay two‐dimensional generic frame models was subjected to an ensemble of 40 ground motions scaled to different intensities. In this investigation, an inelastic ground motion intensity measure was employed to scale each record, which allowed reducing the record‐to‐record variability in the estimation of residual drift demands. The results were statistically processed in order to evaluate the influence of ground motion intensity, number of stories, period of vibration, frame mechanism, system overstrength, and hysteretic behaviour on central tendency of residual drift demands. In addition, a special emphasis was given to evaluate the uncertainty in the estimation of residual drift demands. Results of incremental dynamic analyses indicate that the amplitude and heightwise distribution of residual drift demands strongly depends on the frame mechanism, the heightwise system structural overstrength and the component hysteretic behaviour. An important conclusion for performance‐based assessment is that the evaluation of residual drift demands involves significantly larger levels of uncertainty (i.e. record‐to‐record variability) than that of maximum drift demands, which suggests that this variability and corresponding uncertainty should be explicitly taken into account when estimating residual drift demands during performance‐based seismic assessment of frame buildings. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

20.
This study compares seismic losses considering initial construction costs and direct-repair costs for New Zealand steel moment-resisting frame buildings with friction connections and those with extended bolted-end-plate connections. A total of 12 buildings have been designed and analysed considering both connection types, two building heights (4-storey and 12-storey), and three locations around New Zealand (Auckland, Christchurch, and Wellington). It was found that buildings with friction connections required design to a higher design ductility, yet are generally stiffer due to larger beams being required to satisfy higher connection overstrength requirements. This resulted in the frames with friction connections experiencing lower interstorey drifts on most floors but similar peak total floor accelerations, and subsequently incurring lower drift-related seismic repair losses. Frames with friction connections tended to have lower expected net-present-costs within 50 years of the building being in service for shorter buildings and/or if located in regions of high seismicity. None of the frames with friction connections in Auckland showed any benefits due to the low seismicity of the region.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号