1.
A predictive instantaneous optimal control (PIOC) algorithm is proposed for controlling the seismic responses of elastic structures. This algorithm compensates for the time delay that happens in practical control applications by predicting the structural response over a period that equals the time delay, and by substituting the predicted response in the instantaneous optimal control (IOC) algorithm. The unique feature of this proposed PIOC algorithm is that it is simple and at the same time compensates for the time delay very effectively. Numerical examples of single degree of freedom structures are presented to compare the performance of PIOC and IOC systems for various time delay magnitudes. Results show that a time delay always causes degradation of control efficiency, but PIOC can greatly reduce this degradation compared to IOC. The effects of the structure's natural periods and the choice of control gains on the degradation induced by the time delay are also analyzed. Results show that shorter natural periods and larger control gains are both more sensitive and more serious to the degradation of control efficiency. Finally, a practical application of PIOC is performed on a six‐story moment‐resisting steel frame. It is demonstrated that PIOC contributes significantly to maintain stability in multiple degree of freedom structures, and at the same time PIOC has a satisfactory control performance. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

2.
本文通过弹性和弹塑性时程分析,研究了水平地震作用下梁铰型屈服RC框架模型结构的楼层屈服剪力系数、基本自振周期、楼层数3个因素对弹塑性位移增大系数的影响,通过非线性回归分析给出了弹塑性层间位移增大系数经验公式;通过分析滞回耗能沿楼层高度的分布,初步确定了梁铰型屈服RC框架结构的薄弱楼层位置;基于结构损伤分析,讨论了抗震规范中RC框架结构弹塑性层间位移角限值的水准。  相似文献   

3.
A modified force analogy method (MFAM) is developed to simulate the nonlinear inelastic response of reinforced concrete (RC) structures. Beam–column elements with three different plastic mechanisms are utilized to simulate inelastic response caused by moment and shear force. A multi‐linear hysteretic model is implemented to simulate the nonlinear inelastic response of RC member. The P‐Δ effect of the structure is also addressed in MFAM. Static and dynamic inelastic response of structure, damage condition and failure type for structural element, structural limit state and collapse time can also be simulated using MFAM. Compared with the general algorithm, the MFAM provides less computational time especially in the case of large structural system. It is also easier to be written as computer program. Three test data groups, which include cyclic loading test data of a non‐ductile RC bridge column, a two‐storey RC frame, and dynamic collapse test data of a non‐ductile RC portal frame, are selected to confirm the effectiveness of applying MFAM to simulate the inelastic behaviour of structures. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

4.
An improved linear‐elastic analysis procedure is developed in this paper as a simple approximate method for displacement‐based seismic assessment of the existing buildings. The procedure is mainly based on reducing the stiffness of structural members that are expected to respond in the inelastic range in a single global iteration step. Modal spectral displacement demands are determined from the equal displacement rule. Response predictions obtained from the proposed procedure are evaluated comparatively by using the results of benchmark nonlinear response history analysis, and both the conventional and the multi‐mode pushover analyses. In comparative evaluations, a twelve‐story RC plane frame and a six‐story unsymmetrical‐plan RC frame are employed by using 91 ground motion components. It is observed that the proposed procedure estimates the flexural deformation demands in deformation‐controlled members and the shear forces in force‐controlled members with reasonable accuracy. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
Near‐fault ground motions impose large demands on structures compared to ‘ordinary’ ground motions. Recordings suggest that near‐fault ground motions with ‘forward’ directivity are characterized by a large pulse, which is mostly orientated perpendicular to the fault. This study is intended to provide quantitative knowledge on important response characteristics of elastic and inelastic frame structures subjected to near‐fault ground motions. Generic frame models are used to represent MDOF structures. Near‐fault ground motions are represented by equivalent pulses, which have a comparable effect on structural response, but whose characteristics are defined by a small number of parameters. The results demonstrate that structures with a period longer than the pulse period respond very differently from structures with a shorter period. For the former, early yielding occurs in higher stories but the high ductility demands migrate to the bottom stories as the ground motion becomes more severe. For the latter, the maximum demand always occurs in the bottom stories. Preliminary regression equations are proposed that relate the parameters of the equivalent pulse to magnitude and distance. The equivalent pulse concept is used to estimate the base shear strength required to limit story ductility demands to specific target values. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

6.
Near‐fault ground motions with forward directivity are characterized by a large pulse. This pulse‐like motion may cause a highly non‐uniform distribution of story ductility demands for code‐compliant frame structures, with maximum demands that may considerably exceed the level of code expectations. Strengthening techniques for multi‐story frame structures are explored with the objective of reducing maximum drift demands. One option is to modify the code‐based SRSS distribution of story shear strength over the height by strengthening of the lower stories of the frame. The modified distribution reduces the maximum story ductility demand, particularly for weak and flexible structures. However, this strengthening technique is less effective for stiff structures, and is almost ineffective in cases in which the maximum demand occurs in the upper stories, i.e. strong and flexible structures. As an alternative, the benefits of strengthening frames with elastic and inelastic walls are evaluated. The effects of adding walls that are either fixed or hinged at the base are investigated. It is demonstrated that strengthening with hinged walls is very effective in reducing drift demands for structures with a wide range of periods and at various performance levels. Wall inelastic behavior only slightly reduces the benefits of strengthening with hinged walls.Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

7.
A semi‐active multi‐step predictive control (SAMPC) system with magnetorheological (MR) dampers is developed to reduce the seismic responses of structures. This system can predict the next multi‐step responses of structure according to the current state and has a function of self‐compensation for time delay that occurred in real application. To study the performance of the proposed control algorithm for addressing time delay and reducing the seismic responses, a numerical example of an 11‐story structure with MR dampers is presented. Comparison with the uncontrolled structure indicates that both the peak and the norm values of structural responses are all clearly reduced when the predictive length l?10 and the delayed time step d?20 are selected, and the SAMPC strategy can guarantee the stability of the controlled structure and reduce the effects of time delay on controlled responses to a certain extent. A performance comparison is also made between the SAMPC strategy and the passive‐off and passive‐on methods; results indicate that this SAMPC system is more effective than the two passive methods in reducing structural responses subjected to earthquakes. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
This paper presents an effective optimization technique for the elastic and inelastic drift performance design of reinforced concrete buildings under response spectrum loading and pushover loading. Attempts have been made to develop an automatic optimal elastic and inelastic drift design of concrete framework structures. The entire optimization procedure can be divided into elastic design optimization and inelastic design optimization. Using the principle of virtual work, the elastic drift response generated by the response spectrum loading and the inelastic drift response produced by the non‐linear pushover loading can be explicitly expressed in terms of element sizing design variables. The optimization methodology for the solution of the explicit design problem of buildings is fundamentally based on the Optimality Criteria approach. One ten‐story, two‐bay building frame example is presented to illustrate the effectiveness and practicality of the proposed optimal design method. While rapid convergence in a few design cycles is found in the elastic optimization process, relatively slow but steady and smooth convergence of the optimal performance‐based design is found in the inelastic optimization process. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

9.
The time delay resulting from the servo hydraulic systems can potentially destabilize the real‐time dynamic hybrid testing (RTDHT) systems. In this paper, the discrete‐time root locus technique is adopted to investigate the delay‐dependent stability performance of MDOF RTDHT systems. Stability analysis of an idealized two‐story shear frame with two DOFs is first performed to illustrate the proposed method. The delay‐dependent stability condition is presented for various structural properties, time delay, and integration time steps. Effects of delay compensation methods on stability are also investigated. Then, the proposed method is applied to analyze the delay‐dependent stability of a single shaking table RTDHT system with an 18‐DOF finite element numerical substructure, and corresponding RTDHTs are carried out to verify the theoretical results. Furthermore, the stability behavior of a finite element RTDHT system with two physical substructures, loaded by twin shaking tables, is theoretically and experimentally investigated. All experimental results convincingly demonstrate that the delay‐dependent stability analysis on the basis of the discrete‐time root locus technique is feasible. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
A generalized multi‐mode pushover analysis procedure was developed for estimating the maximum inelastic seismic response of symmetrical plan structures under earthquake ground excitations. Pushover analyses are conducted with story‐specific generalized force vectors in this procedure, with contributions from all effective modes. Generalized pushover analysis procedure is extended to three‐dimensional torsionally coupled systems in the presented study. Generalized force distributions are expressed as the combination of modal forces to simulate the instantaneous force distribution acting on the system when the interstory drift at a story reaches its maximum value during seismic response. Modal contributions to the generalized force vectors are calculated by a modal scaling rule, which is based on the complete quadratic combination. Generalized forces are applied to the mass centers of each story incrementally for producing nonlinear static response. Maximum response quantities are obtained when the individual frames attain their own target interstory drift values in each story. The developed procedure is tested on an eight‐story frame under 15 ground motions, and assessed by comparing the results obtained from nonlinear time history analysis. The method is successful in predicting the torsionally coupled inelastic response of frames responding to large interstory drift demands. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
For the purpose of estimating the earthquake response, particularly the story drift demand, of reinforced concrete (R/C) buildings with proportional hysteretic dampers, an equivalent single‐degree‐of‐freedom (SDOF) system model is proposed. Especially in the inelastic range, the hysteretic behavior of an R/C main frame strongly differs from that of hysteretic dampers due to strength and stiffness degradation in R/C members. Thus, the proposed model, unlike commonly used single‐spring SDOF system models, differentiates the restoring force characteristics of R/C main frame and hysteretic dampers to explicitly take into account the hysteretic behavior of dampers. To confirm the validity of the proposed model, earthquake responses of a series of frame models and their corresponding equivalent SDOF system models were compared. 5‐ and 10‐story frame models were studied as representative of low‐ and mid‐rise building structures, and different mechanical properties of dampers—yield strength and yield deformation—were included to observe their influence on the effectiveness of the proposed model. The results of the analyses demonstrated a good correspondence between estimated story drift demands using the proposed SDOF system model and those of frame models. Moreover, the proposed model: (i) led to better estimates than those given by a single‐spring SDOF system model, (ii) was capable of estimating the input energy demand and (iii) was capable of estimating the total hysteretic energy and the participation of dampers into the total hysteretic energy dissipation, in most cases. Results, therefore, suggest that the proposed model can be useful in structural design practice. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
A design strategy for control of buildings experiencing inelastic deformations during seismic response is formulated. The strategy is using weakened, and/or softened, elements in a structural system while adding passive energy dissipation devices (e.g. viscous fluid devices, etc.) in order to control simultaneously accelerations and deformations response during seismic events. A design methodology is developed to determine the locations and the magnitude of weakening and/or softening of structural elements and the added damping while insuring structural stability. A two‐stage design procedure is suggested: (i) first using a nonlinear active control algorithm, to determine the new structural parameters while insuring stability, then (ii) determine the properties of equivalent structural parameters of passive system, which can be implemented by removing or weakening some structural elements, or connections, and by addition of energy dissipation systems. Passive dampers and weakened elements are designed using an optimization algorithm to obtain a response as close as possible to an actively controlled system. A case study of a five‐story building subjected to El Centro ground motion, as well as to an ensemble of simulated ground motions, is presented to illustrate the procedure. The results show that following the design strategy, a control of both peak inter‐story drifts and total accelerations can be obtained. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
This paper describes an analytical investigation on a reinforced concrete lateral load resisting structural system comprising a pin‐supported (base‐rocking) shear wall coupled with a moment frame on 1 or both sides of the wall. Yielding dampers are used to provide supplemental energy dissipation through the relative displacements at the vertical connections between the wall and the frames. The study extends a previous linear‐elastic model for pin‐supported wall‐frame structures by including the effects of the dampers. A closed‐form solution of the lateral load behavior of the structure is derived by approximating the discrete wall‐frame‐damper interactions with distributed (ie, continuous) properties. The validity of the model is verified by comparing the closed‐form results with computational models using OpenSees program. Then, a parametric analysis is conducted to investigate the effects of the wall, frame, and damper stiffness on the behavior of the structure. It is found that the damper stiffness significantly affects the distribution of shear forces and bending moments over the wall height. Finally, the performance‐based plastic design approach extended to the wall‐frame‐damper system is proposed. Case studies are carried out to design 2 damped pin‐supported wall‐frame structures using the proposed approach. Nonlinear dynamic time‐history analyses are conducted to verify the effectiveness of this method. Results indicate that the designed structures can achieve the performance level with the story drift ratios less than target values, and weak‐story failure mechanism is not observed. The approach can be used in engineering applications.  相似文献   

14.
Real‐time hybrid simulation provides a viable method to experimentally evaluate the performance of structural systems subjected to earthquakes. The structural system is divided into substructures, where part of the system is modeled by experimental substructures, whereas the remaining part is modeled analytically. The displacements in a real‐time hybrid simulation are imposed by servo‐hydraulic actuators to the experimental substructures. Actuator delay compensation has been shown by numerous researchers to vitally achieve reliable real‐time hybrid simulation results. Several studies have been performed on servo‐hydraulic actuator delay compensation involving single experimental substructure with single actuator. Research on real‐time hybrid simulation involving multiple experimental substructures, however, is limited. The effect of actuator delay during a real‐time hybrid simulation with multiple experimental substructures presents challenges. The restoring forces from experimental substructures may be coupled to two or more degrees of freedom (DOF) of the structural system, and the delay in each actuator must be adequately compensated. This paper first presents a stability analysis of actuator delay for real‐time hybrid simulation of a multiple‐DOF linear elastic structure to illustrate the effect of coupled DOFs on the stability of the simulation. An adaptive compensation method then proposed for the stable and accurate control of multiple actuators for a real‐time hybrid simulation. Real‐time hybrid simulation of a two‐story four‐bay steel moment‐resisting frame with large‐scale magneto‐rheological dampers in passive‐on mode subjected to the design basis earthquake is used to experimentally demonstrate the effectiveness of the compensation method in minimizing actuator delay in multiple experimental substructures. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
Optimal design of viscoelastic dampers using eigenvalue assignment   总被引:1,自引:0,他引:1  
In this study a procedure for determining the optimum size and location of viscoelastic dampers is proposed using the eigenvalue assignment technique. Natural frequencies and modal damping ratios, required to realize a given target response, are determined first by the convex model. Then the desired dynamic structural properties are realized by optimally distributing the damping and stiffness coefficients of viscoelastic dampers using non‐linear programming based on the gradient of eigenvalues. This optimization method provides information on the optimal location as well as the magnitude of the damper parameters. The proposed procedure is applied to the retrofit of a 10‐story shear frame, and to a three‐dimensional structure with an asymmetric plan. The analysis results confirm that the responses of model structures retrofitted by the proposed method correspond well with the given target response. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

16.
In this study, the torsional response of buildings with peripheral steel‐braced frame lateral systems is evaluated. A three‐dimensional model of a three story braced frame with various levels of eccentricity is created and the effects of torsion on the seismic response is assessed for four hazard levels. The response history analysis results indicate that, unlike frame structures, the torsional amplifications in the inelastic systems exceed those of corresponding elastic systems and tend to increase with an increase in the level of inelasticity. The ability of two simplified procedures, elastic response spectrum analysis and pushover analysis, to capture the torsional amplifications in steel‐braced frames is evaluated. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
Post‐earthquake safety evaluation of steel moment‐resisting frames mainly relies on the inspection of seismic damage to beam–column connections. Recently, in order to evaluate seismic damage of steel connections in a prompt and precise manner, a local damage evaluation method based on dynamic strain responses has been proposed and receives attention. In the evaluation method where strain responses are measured by piezoelectric strain sensors, a strain‐based damage index has been developed for evaluating individual seismic beam damage in a steel frame. However, for a steel frame suffering multiple beam damages, the damage index deteriorates its performance in identifying small damages with the presence of neighboring severe damages because of the moment redistributions induced by larger damages. This paper presents a decoupling algorithm that removes the issue of damage interaction and improves the performance of the damage index. The decoupling algorithm was derived on the basis of damage‐induced moment release and redistribution mechanism. The effectiveness of the decoupling algorithm was numerically and experimentally investigated using a nine‐story steel frame model and a large scale five‐story steel frame testbed that can simulate multiple fractures at beam ends. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

18.
This paper proposes a model‐based state observer to perform high‐definition response estimation in partially instrumented building structures. The proposed estimator is verified in a simulated five‐story shear‐building structure and validated using measurements from a seven‐story reinforced concrete building slice tested at the NEES‐University of California at San Diego shake table. In both cases the proposed estimator yielded satisfactory results by estimating the time history of shear forces, bending moments, displacements, and strains at various points/sections of interest. The proposed algorithm can be used in instrumented buildings for various practical applications such as post‐earthquake damage assessment, structural control, and building code calibration. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

19.
A numerical investigation was undertaken to evaluate the response of dual structural systems that consisting of steel plate shear walls and moment‐resisting frames. The primary objective of the study was to investigate the influence of elastic base shear distribution between the wall and the frame on the global system response. A total of 10 walls and 30 wall–frame systems, ranging from 3 to 15 stories, were selected for numerical assessment. These systems represent cases in which the elastic base shear resisted by the frame has a share of 10, 25, or 50% of the total base shear resisted by the dual system. The numerical study consisted of 1600 time history analyses employing three‐dimensional finite elements. All 40 structures were separately analyzed for elastic and inelastic response by subjecting them to the selected suite of earthquake records. Interstory drifts, top story drift, base shears resisted by the wall, and the frame were collected during each analysis. Based on the analysis results, important response quantities, such as the strength reduction, the overstrength, and the displacement amplification factors, are evaluated herein. Results are presented in terms of displacement measures, such as the interstory drift ratio and the top story drift ratio. Analysis results revealed that the increase in the strength reduction factor with the amount of load share is insignificant. Furthermore, there is an inverse relationship between the ductility reduction and the overtsrength. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
The discrete‐time variable structure control method for seismically excited linear structures with time delay in control is investigated in this paper. The control system with time delay is first discretized and transformed into standard discrete form which contains no time delay in terms of the time delay being integer and non‐integer times of sampling period, respectively. Then the discrete switching surface is determined using ideal quasi‐sliding mode and discrete controller is designed using the discrete approach‐law reaching condition. The deduced controller and switching surface contain not only the current step of state feedback but also linear combination of some former steps of controls. Numerical simulations are illustrated to verify the feasibility and robustness of the proposed control method. Since time‐delay effect is incorporated in the mathematical model for the structural control system throughout the derivation of the proposed algorithm, system performance and dynamic stability are guaranteed. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   