首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new inelastic structural control algorithm is proposed by incorporating the force analogy method (FAM) with the predictive instantaneous optimal control (PIOC) algorithm. While PIOC is very effective in compensating for the time delay for elastic structures, the FAM is highly efficient in performing the inelastic analysis. Unlike conventional inelastic analysis methods of changing stiffness, the FAM analyzes structures by varying the structural displacement field, and therefore the state transition matrix needs to be computed only once. This greatly simplifies the computation and makes inelastic analysis readily applicable to the PIOC algorithm. The proposed algorithm compensates for the time delay that happens in practical control systems by predicting the inelastic structural response over a period that equals the magnitude of the time delay. A one‐story frame with both strain‐hardening and strain‐softening inelastic characteristics is analyzed using this algorithm. Results show that the proposed control algorithm is feasibile for any inelastic structures. While the control efficiency deteriorates with the increase in magnitude of the time delay, the PIOC maintains acceptable performance within a wide range of time delay magnitudes. Finally, a computer model of a six‐story moment‐resisting steel frame is analyzed to show that PIOC has good control results for real inelastic structures. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

2.
A computational method of energy evaluation is derived to study the elastic responses and energy distribution of actively controlled single‐degree‐of‐freedom (SDOF) structures during earthquakes. Contrary to the common perception that applying active control force pumps energy into the structure, the applied control force can actually reduce the energy in the structure by reducing the input energy from earthquakes to the structure. In addition, applying control force can dissipate a large amount of energy in the structure when this control force is applied in the direction opposite to the displacement and velocity responses. To demonstrate this energy mechanism in active controlled structures, the two most popular control algorithms, optimal linear control (OLC) and instantaneous optimal control (IOC) algorithms, are used to calculate the control response and energy spectra. One‐step time delay is incorporated into the algorithms to take into consideration the practical aspect of active control. The effects of different earthquakes and damping ratios on control energy and response spectra are studied. These studies show that both OLC and IOC are very effective in reducing the structural displacement and velocity responses by reducing the input earthquake energy as well as dissipating a large amount of energy in the structure. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

3.
A computational algorithm for maximizing the control efficiency in actively controlling the elastic structural responses during earthquake is proposed. Study of optimal linear control using a single degree of freedom shows that applying active control is very effective in reducing the structural displacement and velocity responses for long‐period structures, but at the same time it has an adverse effect in increasing the absolute acceleration response. The extent of this adverse effect reduces the effectiveness of the control system, and therefore it poses a limit on the maximum control force in order to provide maximum control efficiency. In view of this shortcoming, maximum control energy dissipation is used to define the most effective optimal linear control law. Less displacement and velocity response are expected as larger control force is applied, but there is always a limit that maximum control energy can be dissipated. This study shows that this limit depends on the structural characteristics as well as the input ground motion, and a general trend is that the maximum control energy decreases as damping increases. Finally, application of the proposed algorithm on a six‐storey hospital building is presented to show the effectiveness of using optimal linear control on a multi‐degree‐of‐freedom system from the control energy perspectives. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

4.
结构瞬时开闭环最优控制算法中的迟时研究   总被引:1,自引:0,他引:1  
本文运用四阶Runge-Kutta法建立了在迟时情况下结构状态方程的离散形式,采用瞬时控制开闭环最优控制算法对开环、闭环和开闭环控制中迟时的影响进行研究,并根据闭环控制的原理提出了迟时补偿算法,以减小迟时的影响。  相似文献   

5.
This paper presents a theoretical study of a predictive active control system used to improve the response of multi‐degree‐of‐freedom (MDOF) structures to earthquakes. As an example a building frame equipped with electrorheological (ER) dampers is considered. The aim of the design is to find a combination of forces that are produced by the ER dampers in order to obtain an optimal structural response. The mechanical response of ER fluid dampers is regulated by an electric field. Linear auto‐regressive model with exogenous input (ARX) is used to predict the displacements and the velocities of the frame in order to overcome the time‐delay problem in the control system. The control forces in the ER devices are calculated at every time step by the optimal control theory (OCT) according to the values of the displacements and of the velocities that are predicted at the next time step at each storey of the structure. A numerical analysis of a seven‐storey ER damped structure is presented as an example. It shows a significant improvement of the structural response when the predictive active control system is applied compared to that of an uncontrolled structure or that of a structure with controlled damping forces with time delay. The structure's displacements and velocities that were used to obtain the optimal control forces were predicted according to an ‘occurring’ earthquake by the ARX model (predictive control). The response was similar to that of the structure with control forces that were calculated from a ‘known’ complete history of the earthquake's displacement and velocity values, and were applied without delay (instantaneous control). Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

6.
Two important extensions of a technique to perform a nonlinear error propagation analysis for an explicit pseudodynamic algorithm (Chang, 2003) are presented. One extends the stability study from a given time step to a complete step-by-step integration procedure. It is analytically proven that ensuring stability conditions in each time step leads to a stable computation of the entire step-by-step integration procedure. The other extension shows that the nonlinear error propagation results, which are derived for a nonlinear single degree of freedom (SDOF) system, can be applied to a nonlinear multiple degree of freedom (MDOF) system. This application is dependent upon the determination of the natural frequencies of the system in each time step, since all the numerical properties and error propagation properties in the time step are closely related to these frequencies. The results are derived from the step degree of nonlinearity. An instantaneous degree of nonlinearity is introduced to replace the step degree of nonlinearity and is shown to be easier to use in practice. The extensions can be also applied to the results derived from a SDOF system based on the instantaneous degree of nonlinearity, and hence a time step might be appropriately chosen to perform a pseudodynamic test prior to testing.  相似文献   

7.
Real‐time hybrid testing is a method that combines experimental substructure(s) representing component(s) of a structure with a numerical model of the remaining part of the structure. These substructures are combined with the integration algorithm for the test and the servo‐hydraulic actuator to form the real‐time hybrid testing system. The inherent dynamics of the servo‐hydraulic actuator used in real‐time hybrid testing will give rise to a time delay, which may result in a degradation of accuracy of the test, and possibly render the system to become unstable. To acquire a better understanding of the stability of a real‐time hybrid test with actuator delay, a stability analysis procedure for single‐degree‐of‐freedom structures is presented that includes both the actuator delay and an explicit integration algorithm. The actuator delay is modeled by a discrete transfer function and combined with a discrete transfer function representing the integration algorithm to form a closed‐loop transfer function for the real‐time hybrid testing system. The stability of the system is investigated by examining the poles of the closed‐loop transfer function. The effect of actuator delay on the stability of a real‐time hybrid test is shown to be dependent on the structural parameters as well as the form of the integration algorithm. The stability analysis results can have a significant difference compared with the solution from the delay differential equation, thereby illustrating the need to include the integration algorithm in the stability analysis of a real‐time hybrid testing system. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

8.
In this paper, an effective active predictive control algorithm is developed for the vibration control of non-linear hysteretic structural systems subjected to earthquake excitation. The non-linear characteristics of the structural behaviour and the effects of time delay in both the measurements and control action are included throughout the entire analysis (design and validation). This is very important since, in current design practice, structures are assumed to behave non-linearly, and time delays induced by sensors and actuator devices are not avoidable. The proposed algorithm focuses on the instantaneous optimal control approach for the development of a control methodology where the non-linearities are brought into the analysis through a non-linear state vector and a non-linear open-loop term. An autoregressive (AR) model is used to predict the earthquake excitation to be considered in the prediction of the structural response. A performance index that is quadratic in the control force and in the predicted non-linear states, with two additional energy related terms, and that is subjected to a non-linear constraint equation, is minimized at every time step. The effectiveness of the proposed closed-open loop non-linear instantaneous optimal prediction control (CONIOPC) strategy is presented by the results of numerical simulations. Since non-linearity and time-delay effects are incorporated in the mathematical model throughout the derivation of the control methodology, good performance and stability of the controlled structural system are guaranteed. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

9.
在瞬时最优控制算法理论分析的基础上,分别以单自由度和三自由度结构模型为例,研究了时间间隔和权矩阵对结构控制反应的影响。首先,进行了瞬时最优控制算法的理论分析,提出了控制算法的影响参数;其次,分别对单自由度和三自由度结构在无控、LQR和瞬时最优三种方法控制下,分析了时间间隔和权矩阵对结构反应的影响。结果表明:时间间隔和权矩阵对结构瞬时最优控制效果影响很大。  相似文献   

10.
Time delay problem and its compensation in active control of civil engineering structures were studied. It has been shown by stability analysis of a SDOF system with time delayed feedback that the maximum allowable time delay depends not only on the natural period of the structure but also on feedback gains. We have demonstrated by numerical simulation that the performance of the control system degrades significantly when the time delay is close to this value and it even becomes unstable when time delay is greater than or equal to this value. The maximum allowable time delay decreases with decrease in natural period of the structure as well as with increase in active damping. The paper presents a technique for compensation by modelling time delay as transportation lag. This method ensures the stability of the controlled system as well as the desired response reduction.  相似文献   

11.
Real‐time pseudodynamic (PSD) and hybrid PSD test methods are experimental techniques to obtain the response of structures, where restoring force feedback is used by an integration algorithm to generate command displacements. Time delays in the restoring force feedback from the physical test structure and/or the analytical substructure cause inaccuracies and can potentially destabilize the system. In this paper a method for investigating the stability of structural systems involved in real‐time PSD and hybrid PSD tests with multiple sources of delay is presented. The method involves the use of the pseudodelay technique to perform an exact mapping of fixed delay terms to determine the stability boundary. The approach described here is intended to be a practical one that enables the requirements for a real‐time testing system to be established in terms of system parameters when multiple sources of delay exist. Several real‐time testing scenarios with delay that include single degree of freedom (SDOF) and multi‐degree of freedom (MDOF) real‐time PSD/hybrid PSD tests are analyzed to illustrate the method. From the stability analysis of the real‐time hybrid testing of an SDOF test structure, delay‐independent stability with respect to either experimental or analytical substructure delay is shown to exist. The conditions that the structural properties must satisfy in order for delay‐independent stability to exist are derived. Real‐time hybrid PSD testing of an MDOF structure equipped with a passive damper is also investigated, where observations from six different cases related to the stability plane behavior are summarized. Throughout this study, root locus plots are used to provide insight and explanation of the behavior of the stability boundaries. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
To solve the different time delays that exist in the control device installed on spatial structures, in this study, discrete analysis using a 2 N precise algorithm was selected to solve the multi-time-delay issue for long-span structures based on the market-based control (MBC) method. The concept of interval mixed energy was introduced from computational structural mechanics and optimal control research areas, and it translates the design of the MBC multi-time-delay controller into a solution for the segment matrix. This approach transforms the serial algorithm in time to parallel computing in space, greatly improving the solving efficiency and numerical stability. The designed controller is able to consider the issue of time delay with a linear controlling force combination and is especially effective for large time-delay conditions. A numerical example of a long-span structure was selected to demonstrate the effectiveness of the presented controller, and the time delay was found to have a significant impact on the results.  相似文献   

13.
It has been proved in the authors' latest paper that the effective location of active control devices for building vibration caused by periodic excitation acting on intermediate story is the adjacent three floors to the vibration source. However, in terms of the Discrete‐Optimizing control method, the control forces are on‐line calculated step‐by‐step and time‐delay must exist. The degradation of control effect caused by time‐delay can not be avoided. In this paper, QN control method is proposed in order to resolve this practical problem. Since the external excitations which the building structure would experience are supposed to be periodic to some degree, Quasi‐Newton method is applied into the close‐loop Linear–Quadratic optimal control method and the new control method is called the ‘QN control method’. In this new control method, instead of solving the Riccati equation, the feedback gain matrix is determined by optimizing the quadratic performance index of the structure with the Quasi‐Newton method, one of the most commonly used minimization of functions. The new control law can easily be implemented for time‐delay problems, the degradation can be greatly improved with compensated feedback gain matrix. As a result, the QN control method is proved to be an efficient method to determine the feedback gain matrix. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

14.
A control method is presented for reducing the dynamic response of structures in the inelastic material range using a control force from an active bracing system. Recent full-scale experiments have verified the feasibility of implementing active control systems for control of seismic structures with existing technology. The proposed method of continuous pulse control uses closed-loop feedback control as a combination of two algorithms. The first is the instantaneous optimal algorithm which was derived assuming linear material behaviour, and the second is pulse control which applies a corrective pulse when a prespecified structural displacement, velocity, or acceleration threshold is exceeded. The three criteria of displacement, velocity, and acceleration lead to three pulse control schemes. Each of the three schemes is used in conjunction with the instantaneous optimal control to yield three continuous pulse algorithms, the displacement continuous pulse, velocity continuous pulse and acceleration continuous pulse. Comparisons between the three continuous pulse algorithms and the pulse control for seismic structures in the inelastic range show that the continuous pulse algorithms use less control energy and reduce the response better than pulse control. A comparison between the velocity continuous pulse and the non-linear optimal algorithm shows that the velocity continuous pulse uses a larger control force but is more adaptable than the non-linear optimal algorithm, in the sense that it can reduce the response of a given structure to various probable earthquakes. The non-linear optimal algorithm is more effective than the velocity continuous pulse for a single specific earthquake but is not as effective for other earthquakes which may occur in the life of the structure.  相似文献   

15.
In active control, the control force execution time delay cannot be avoided or eliminated even with present technology, which can be critical to the performance of the control system. This paper investigates the influence of time delay on the stability of an SDOF system with an optimal direct output feedback controlled mass damper. An active mass damper system can take the form of a hybrid mass damper (HMD) or a fully active mass damper (AMD) depending upon imposed design constraints resulting from space, strength and power limitations. Explicit formulas and numerical solutions to determine the maximum delay time which causes onset of system instability are obtained. The control effect of the two‐DOF HMD/AMD benchmark system with and without time delay is illustrated quantitatively in a continuous‐time approach. In order to fit the digital implementation of the computer‐controlled system in practice, the control gains will be compensated by using their discrete‐time version to overcome the degradation of control effect due to time delay. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

16.
Time‐delay is an important issue in structural control. Applications of unsynchronized control forces due to time‐delay may result in a degradation of the control performance and it may even render the controlled structures to be unstable. In this paper, a state‐of‐the‐art review for available methods of time‐delay compensation is presented. Then, five methods for the compensation of fixed time‐delay are presented and investigated for active control of civil engineering structures. These include the recursive response method, state‐augmented compensation method, controllability based stabilization method, the Smith predictor method and the Pade approximation method, all are applicable to any control algorithm to be used for controlled design. Numerical simulations have been conducted for MDOF building models equipped with an active control system to demonstrate the stability and control performance of these time‐delay compensation methods. Finally, the stability and performance of the phase shift method, that is well‐known in civil engineering applications, have also been critically evaluated through numerical simulations. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

17.
The seismic performance of existing structures can be assessed based on nonlinear static procedures, such as the Capacity Spectrum Method. This method essentially approximates peak responses of an inelastic single‐degree‐of‐freedom (SDOF) system using peak responses of an equivalent linear SDOF model. In this study, the equivalent linear models of inelastic SDOF systems are developed based on the constant strength approach, which does not require iteration for assessing the seismic performance of existing structures. To investigate the effects of earthquake type and seismic region on the equivalent linear models, four ground‐motion data sets—Japanese crustal/interface/inslab records and California crustal records—are compiled and used for nonlinear dynamic analysis. The analysis results indicate that: (1) the optimal equivalent linear model parameters (i.e. equivalent vibration period ratio and damping ratio) decrease with the natural vibration period, whereas they increase with the strength reduction factor; (2) the impacts of earthquake type and seismic region on the equivalent linear model parameters are not significant except for short vibration periods; and (3) the degradation and pinching effects affect the equivalent linear model parameters. We develop prediction equations for the optimal equivalent linear model parameters based on nonlinear least‐squares fitting, which improve and extend the current nonlinear static procedure for existing structures with degradation and pinching behavior. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
Real‐time hybrid testing combines experimental testing and numerical simulation, and provides a viable alternative for the dynamic testing of structural systems. An integration algorithm is used in real‐time hybrid testing to compute the structural response based on feedback restoring forces from experimental and analytical substructures. Explicit integration algorithms are usually preferred over implicit algorithms as they do not require iteration and are therefore computationally efficient. The time step size for explicit integration algorithms, which are typically conditionally stable, can be extremely small in order to avoid numerical stability when the number of degree‐of‐freedom of the structure becomes large. This paper presents the implementation and application of a newly developed unconditionally stable explicit integration algorithm for real‐time hybrid testing. The development of the integration algorithm is briefly reviewed. An extrapolation procedure is introduced in the implementation of the algorithm for real‐time testing to ensure the continuous movement of the servo‐hydraulic actuator. The stability of the implemented integration algorithm is investigated using control theory. Real‐time hybrid test results of single‐degree‐of‐freedom and multi‐degree‐of‐freedom structures with a passive elastomeric damper subjected to earthquake ground motion are presented. The explicit integration algorithm is shown to enable the exceptional real‐time hybrid test results to be achieved. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
The neuro‐controller training algorithm based on cost function is applied to a multi‐degree‐of‐freedom system; and a sensitivity evaluation algorithm replacing the emulator neural network is proposed. In conventional methods, the emulator neural network is used to evaluate the sensitivity of structural response to the control signal. To use the emulator, it should be trained to predict the dynamic response of the structure. Much of the time is usually spent on training of the emulator. In the proposed algorithm, however, it takes only one sampling time to obtain the sensitivity. Therefore, training time for the emulator is eliminated. As a result, only one neural network is used for the neuro‐control system. In the numerical example, the three‐storey building structure with linear and non‐linear stiffness is controlled by the trained neural network. The actuator dynamics and control time delay are considered in the simulation. Numerical examples show that the proposed control algorithm is valid in structural control. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

20.
Based on the Hilbert–Huang spectral analysis, a method is proposed to identify multi‐degree‐of‐freedom (MDOF) linear systems using measured free vibration time histories. For MDOF systems, the normal modes have been assumed to exist. In this method, the measured response data, which are polluted by noises, are first decomposed into modal responses using the empirical mode decomposition (EMD) approach with intermittency criteria. Then, the Hilbert transform is applied to each modal response to obtain the instantaneous amplitude and phase angle time histories. A linear least‐square fit procedure is proposed to identify the natural frequency and damping ratio from the instantaneous amplitude and phase angle for each modal response. Based on a single measurement of the free vibration time history at one appropriate location, natural frequencies and damping ratios can be identified. When the responses at all degrees of freedom are measured, the mode shapes and the physical mass, damping and stiffness matrices of the structure can be determined. The applications of the proposed method are illustrated using three linear systems with different dynamic characteristics. Numerical simulation results demonstrate that the proposed system identification method yields quite accurate results, and it offers a new and effective tool for the system identification of linear structures in which normal modes exist. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   