首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 601 毫秒
1.
This paper is the second part of a two‐part paper presenting the cyclic tests of four two‐story narrow steel plate shear walls (SPSWs). The first paper introduces the analytical studies and the specimen designs. This paper describes the test results. Some design implications including the capacity design for the first story column and the width‐to‐thickness ratio check for the beam web are discussed based on key observations from the tests. Test results confirm that the simplified strip model can accurately predict the inelastic responses of the specimens. Test results also confirm that the proposed capacity design method is effective in ensuring the plastic hinge formation at the bottom end of the first story column for SPSW with or without restrainers. Test results also show that the horizontal restrainers are effective in reducing the member forces in the boundary beam and column elements. Comparing the test results of the typical SPSW with those of the restrained SPSW (R‐SPSW) specimens, it is found that the R‐SPSW possesses an improved cyclic performance and reduced material weight. Analytical results predict the compressed column moments at the onset of the column plastic hinge formation well. The analytical hysteretic energy distribution in the first story column agrees very well with the observed inelastic actions developed in the four specimens. The detailed frame response analyses and the test results confirm that the assumptions made in developing the proposed column capacity design method are reasonable. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
Coupled steel plate shear wall (C‐SPSW) consists of two or more steel plate shear walls interconnected by coupling beams at the floor levels. In this study, a six‐story C‐SPSW prototype building was designed. A 40% scale C‐SPSW specimen, which is representative of the bottom two‐and‐half‐story substructure of the prototype, was cyclically tested using Multi‐Axial Testing System at the National Center for Research on Earthquake Engineering in 2009. In addition to a constant vertical force representing the gravity load effects, cyclic increasing displacements and the corresponding overturning moments transmitted from the upper stories were computed online and simultaneously applied on the substructural specimen. This paper firstly introduces the designs of the prototype C‐SPSW and the test specimen. Then, the test results and the numerical simulation are discussed in detail. Test results confirm the effectiveness of the proposed column capacity design method, which aims at limiting the plastic hinge formation within the bottom quarter height of the bottom column. Test and analytical results suggest that the coupling beam rotational demands can be estimated as the design story drifts when the formation of desirable plastic mechanism of the C‐SPSW is expected. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
The steel plate shear wall (SPSW) system is a robust option for earthquake resistance due to the strength, stiffness, ductility and energy dissipation that it provides. Although thin infill plates are efficient for resisting lateral loads, boundary frames that are proportioned based on capacity design requirements add significant structural weight that appears to be one of the factors limiting the use of the system in practice. An alternate configuration, the SPSW with coupling (SPSW‐WC), was explored recently as an option for increasing architectural flexibility while also improving overall system economy and seismic performance. The SPSW‐WC, which extensively employs flexural boundary frame contribution, has shown promise in analytical, numerical and experimental studies, but recent research on uncoupled SPSWs suggests that boundary frame contribution should not be considered for carrying seismic design shear. As a result, in the present study, boundary frame contribution in SPSWs was explored with detailed three‐dimensional finite element models, which were validated against large‐scale SPSW‐WC tests. Six‐story systems were considered, and the study matrix included single and double uncoupled SPSWs along with coupled SPSWs that had various degrees of coupling. Variations in design methodology were also explored. The modeling framework was employed to conduct static monotonic and cyclic pushover analyses and dynamic response history analysis. These analyses demonstrate the beneficial effect of coupling in SPSWs and illustrate the need to consider boundary frame contribution in design of coupled SPSWs. In addition, sharing design shear between the infill plate and the boundary frame is more generally shown to not be detrimental if this sharing is done in the design stage based on elastic analysis and the resulting boundary frame provides adequate secondary strength and stiffness following infill plate yielding. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

4.
The seismic performance of composite steel plate shear walls (CSPSWs) that consist of a steel plate shear wall (SPSW) with reinforced concrete (RC) panels attached to one or both sides by means of bolts or connectors is experimentally studied. The shear wall is connected to the frame beams but not to the columns. This arrangement restrains the possible out-of-plane buckling of the thin-walled steel plate, thus significantly increasing the bearing capacity and ductility of the overall wall, and prevents the premature overall or local buckling failure of the frame columns. From a practical viewpoint, these solutions can provide open space in a floor as this type of composite shear walls with a relatively small aspect ratio can be placed parallel along a bay. In this study, four CSPSWs and one SPSW were tested and the results showed that both CSPSWs and SPSW possessed good ductility. For SPSW alone, the buckling appeared and resulted in a decrease of bearing capacity and energy dissipation capacity. In addition, welding stiffeners at corners were shown to be an effective way to increase the energy dissipation capacity of CSPSWs.  相似文献   

5.
The steel plate shear wall (SPSW) is an effective lateral force resisting system in which unstiffened steel infill plates are connected to the horizontal and vertical boundary elements (VBEs) on all sides of the plates. The boundary elements must be designed to resist the tension field force of the infill panels. When the VBEs are made from a steel box section, the flange of each box VBE connected with the infill panels can be pulled out‐of‐plane by significant panel forces, called pull‐out action. This study investigates capacity design methods for box VBEs in SPSWs. Simplified fixed beam and portal frame models aim to estimate the pull‐out responses of the flange of the box sections with and without infill concrete, respectively. In this study, cyclic tests of three full‐scale two‐story SPSWs using box VBEs with or without the infill concrete are conducted. Inelastic pushover analyses of the finite element models are conducted. The tests and analytical results confirm that the proposed design methods, which aimed to prevent the full yield of the flange under the pull‐out action, are applicable. Furthermore, the test and analytical results suggest that the initial yielding of the flange of box VBEs under the collective effects of the pull‐out action on the flange, the gravity load, and the sway action on the SPSW represents a local yielding. A strict prohibition of the initial yielding on the flange under the aforementioned collective effects is not recommended for pursuing a cost‐effective design. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

6.
本文针对钢板剪力墙结构自振周期缺乏研究的现状,将钢板剪力墙简化为Timoshenko梁,提出了考虑周边框架影响的钢板剪力墙等效抗剪刚度计算的方法,然后根据Southwell-Dunkerley理论,给出了钢板剪力墙结构基本自振周期的简化计算公式。然后,通过56个算例比较分析了本文公式计算结果与有限元计算结果发现:本文公式计算结果与有限元结果之比的平均值为1.015,标准差为0.049,说明本文公式具有足够的可靠性。接着,又对结构高度、均布质量、等效抗剪、抗弯刚度、钢板的高厚比、高宽比等参数进行了分析,分析结果表明:随着结构高度与均布质量开方的乘积增大,结构的基本自振周期增长;层数相同时,随着等效抗剪刚度、抗弯刚度的增大,周期有减小的趋势;层数相同时,随着钢板高厚比与高宽比乘积的增大,周期增长。  相似文献   

7.
Steel plate shear walls (SPSWs) are used as lateral force‐resisting systems in new and retrofitted structures in high‐seismic regions. Various international codes recommend the design of SPSWs assuming the entire lateral load to be resisted by the infill plates. Such a design procedure results in significant overstrength leading to uneconomical and inefficient use of materials. This study is focused on the estimation of contribution of boundary elements in resisting the lateral force considering their interaction with the web plates of SPSW systems. Initially, the relative contribution of web plates and boundary frames is computed for a single‐bay single‐story frame with varying rigidity and end connections of boundary elements. Nonlinear static analyses are carried out for the analytical models in OpenSees platform to quantify this contribution. Later, this study is extended to the code‐based designed three‐story, six‐story, and nine‐story SPSWs of varying aspect ratios. Based on the results obtained, a new design procedure is proposed taking the lateral strengths of the boundary frames into account. Nonlinear time‐history analyses are conducted for 40 recorded ground motions representing the design basis earthquake and maximum considered earthquake hazard levels to compare the interstory and residual drift response and yield mechanisms of SPSWs designed as per current practice and the proposed methodology. Finally, an expression has been proposed to predict the lateral force contribution of the infill plate and the boundary frame of SPSWs. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

8.
A new type of steel plate shear wall (SPSW) with oval-curved architectural openings and vertically flexible horizontal connection elements is proposed. The vertical flexibility of the wall accommodates the construction settlement introduced by column contraction under the dead loads of the upper stories and allows sequential installation from the lower stories. A quasi-static cyclic loading test and finite element (FE) analysis verified the stable seismic behaviors of the ovally-perforated vertically-flexible steel plate shear wall (OVSPW). The results of FE parametric analysis showed that an OVSPW with an appropriate thickness of boundary elements effectively accommodated the construction settlement that could lead to large in-plane compression for a conventional SPSW. The horizontal connection elements made of steel tubes realized the vertical stiffness of OVSPW to less than 2% of the original value without changing the lateral stiffness. New design equations of the OVSPW were derived through integral and extreme value solutions to predict the mechanical behavior of OVSPW.  相似文献   

9.
This research investigates the seismic design method and the cyclic inelastic behavior of the bottom column, also called the vertical boundary element (VBE), in steel plate shear walls (SPSWs). This study consists of two parts. This Part 1 paper discusses the anticipated pushover responses for properly designed SPSWs and the possible inelastic responses of the bottom VBE at various levels of inter‐story drift. Considering both the tension field action of the infill panel and the sway action of the boundary frame, this study develops a simplified method to compute the flexural and shear demands in the bottom VBE. Based on the superposition method, this approach considers various plastic hinge forming locations at different levels of inter‐story drift. One of the key performance‐based design objectives is to ensure that the top ends of the bottom VBEs remain elastic when the SPSWs are subjected to the maximum considered earthquake. This paper presents the comprehensive design procedures for the bottom VBE. Furthermore, this study conducted cyclic performance evaluation tests of three full‐scale two‐story SPSWs at the Taiwan National Center for Research on Earthquake Engineering in 2011 to validate the effectiveness of the proposed design methods. The experimental program, cyclic inelastic responses of the SPSWs and bottom VBEs, and numerical simulations are presented in Part 2. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
This paper describes an experiment to investigate the seismic design and responses of the bottom column, also called the bottom vertical boundary element (VBE), in steel plate shear walls (SPSWs). The main objectives of this experiment include validating the effectiveness of the design method developed in the companion paper, investigating the experimental performance of VBEs under large interstory drifts, and calibrating analytical models for earthquake engineering of SPSWs. Three full‐scale two‐story SPSWs were cyclically tested at the Taiwan National Center for Research on Earthquake Engineering in 2011. Test results and numerical simulations confirm that the proposed design procedures are effective in predicting the plastic zone forming elevation in the lower half of the bottom VBE and the occurrence of yielding at the VBE's top end. Test results show that the premature yielding occurring at the top end of a bottom VBE would result in a deformation concentration at the bottom of SPSWs. In addition, lateral torsional buckling could take place on the bottom VBE after significant plastic rotations have developed at the top end. Test results suggest that preventing the VBE's top end from yielding is the key issue in the seismic design of SPSWs, and the proposed method can be effectively adopted to achieve this objective. Furthermore, the inelastic responses of the SPSW specimens were satisfactorily simulated by using detailed finite shell elements or simplified frame response analysis models. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
Previous research has shown that self‐centering steel plate shear walls (SC‐SPSWs) are capable of achieving enhanced seismic performance at multiple hazard levels, including recentering following design‐level earthquakes. When modeling SC‐SPSWs numerically, these studies considered an idealized tension‐only steel plate shear wall (SPSW) web plate behavior. Research has shown that web plate behavior is more complex than predicted by the idealized model, and web plates can provide more strength, stiffness, and energy dissipation than predicted by the idealized model. The idealized model of web plate behavior is used widely in SPSW numerical models where the moment‐resisting boundary frame provides supplemental hysteretic damping and stiffness; however, in SC‐SPSWs, where the post‐tensioned boundary frame is designed to remain elastic during an earthquake, accounting for the more complex web plate behavior can have a significant impact on seismic performance estimates from numerical simulation. This paper presents different methods for modeling SC‐SPSWs. Responses from these models are compared with experimental results. A simple modification of the tension‐only model, referred to as the tension‐compression strip model, is shown to provide a reasonable approximation of SC‐SPSW behavior. Results from nonlinear response history analyses of SC‐SPSWs with the tension‐only and tension‐compression web plate models are compared to assess how the approximation of web plate behavior affects SC‐SPSW seismic performance. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
Design recommendations for steel plate shear wall (SPSW) systems have recently been introduced into seismic provisions for steel buildings. Response modification (R), overstrength (Ωo), and displacement amplification (Cd) factors for SPSW systems presented in design codes were based on professional experience and judgment. A numerical study has been undertaken to evaluate these factors for SPSW systems. Forty‐four unstiffened SPSW possessing different geometrical characteristics were designed based on the recommendations given in the AISC Seismic Provisions. Bay width, number of stories, story mass, and steel plate thickness were considered as the prime variables that influence the response. Twenty records were selected to include the variability in ground motion characteristics. In order to provide a detailed analysis of the post‐buckling response, three‐dimensional finite element analyses were conducted for the 44 structures subjected to the selected suite of earthquake records. For each structure and earthquake record, two analyses were conducted in which the first includes geometrical nonlinearities and the other includes both geometrical and material nonlinearities, resulting in a total of 1760 time history analyses. In this paper, the details of the design and analysis methodology are given. Based on the analysis results, response modification (R), overstrength (Ωo), and displacement amplification (Cd) factors for SPSW systems are evaluated. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
Unstiffened steel plate shear walls (SPSWs) are used as lateral load‐resisting systems in building structures. The energy dissipation mechanism of SPSWs consists of the tension yielding of web plates and the formation of plastic hinges at the ends of horizontal boundary elements. However, vertical boundary elements (VBEs) of high‐rise SPSWs may experience high axial forces under lateral loading. This study explores the effectiveness of staggering of web plates on the reduction of VBE forces and drift response of SPSWs during an earthquake event. An analytical study has been conducted to determine the base shear reduction factor so as to match the overstrength of staggered systems with conventional SPSWs. A design methodology has been proposed for staggered SPSWs. Six‐, 9‐, and 20‐storey staggered and conventional SPSWs with varying aspect ratios are considered in this study to compare their seismic response. These study frames are modelled and analysed in OpenSEES platform. Nonlinear static and dynamic analyses are performed to compare the drift response, hinge mechanisms, and steel tonnage. Staggered SPSWs showed uniform drift distribution and reduction in interstorey drift and axial force demand on the VBEs.  相似文献   

14.
防屈曲开斜槽耗能钢板剪力墙的滞回性能分析   总被引:1,自引:0,他引:1  
防屈曲开斜槽耗能钢板剪力墙(简称开斜槽剪力墙)是通过在钢板上开设一定数量斜槽,并在其两侧外挂混凝土板而形成的一种新型高层钢结构抗侧耗能构件。根据开斜槽钢板剪力墙的承载机制,采用理论推导的方法得到其承载力计算公式,利用ANSYS有限元方法对开斜槽剪力墙进行模拟,并通过改变不同参数验证了计算公式的准确性。同时,采用ANSYS建立有限元模型,对开斜槽剪力墙和普通薄钢板剪力墙的滞回性能进行了对比分析。结果表明,在提供足够约束(钢板与混凝土板间隙适宜,混凝土板厚度足够)的前提下,相对于普通薄钢板剪力墙,开斜槽剪力墙改善了钢板的捏缩现象,具有更稳定的耗能能力。  相似文献   

15.
Cyclic loading tests were performed on three one‐storey steel frames and four three‐storey concrete‐filled tube (CFT) moment frames reinforced with a new type of earthquake‐resisting element consisting of a steel plate shear wall with vertical slits. In this shear wall system, the steel plate segments between the slits behave as a series of flexural links, which provide fairly ductile response without the need for heavy stiffening of the wall. The steel shear walls and the moment frames behaved in a ductile manner up to more than 4% drift without abrupt strength degradation or loss of axial resistance. Results of these tests and complementary analysis provide a basis for an equivalent brace model to be employed in commercially available frame analysis programs. Test and analytical results suggest that the horizontal force is carried by the bolts in the middle portion of the wall–frame connection, while the vertical forces coupled with the moment in the connection are resisted by the bolts in the edge portion of the connection, for which the friction bolts in the connection should be designed. When sufficient transverse stiffening is provided, full plastic strength and non‐degrading hysteretic behaviour can be achieved for this new type of shear wall. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

16.
新型带缝钢板剪力墙的试验研究及其数值模拟   总被引:8,自引:4,他引:8  
对4个足尺钢板剪力墙模型在水平低周反复荷载作用下的力学性能进行了试验研究。试验结果表明稳定是控制未采取构造措施带缝钢板剪力墙承载力的主要因素;模拟试验过程的计算结果表明,改进的带缝钢板剪力墙可以增加延性,耗散较大的地震能量。  相似文献   

17.
Earthquake simulation tests were conducted on a 1 : 15‐scale 25‐story building model to verify the seismic performance of high‐rise reinforced‐concrete flat‐plate core‐wall building structures designed per the recent seismic code KBC 2009 or IBC 2006. The following conclusions can be drawn from the test results: (1) The vertical distribution of acceleration during the table excitations revealed the effect of the higher modes, whereas free vibration after the termination of the table excitations was governed by the first mode. The maximum values of base shear and roof drift during the free vibration are either similar to or larger than the values of the maximum responses during the table excitation. (2) With a maximum roof drift ratio of 0.7% under the maximum considered earthquake in Korea, the lateral stiffness degraded to approximately 50% of the initial stiffness. (3) The crack modes appear to be a combination of flexure and shear in the slab around the peripheral columns and in the coupling beam. Energy dissipation via inelastic deformation was predominant during free vibration after the termination of table excitation rather than during table excitation. Finally, (4) the walls with special boundary elements in the first story did not exhibit any significant inelastic behavior, with a maximum curvature of only 21% of the ultimate curvature, corresponding to an ultimate concrete compressive strain of 0.00638 m/m intended in the displacement‐based design approach. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
钢框架-带缝钢板剪力墙结构受力性能分析   总被引:1,自引:0,他引:1  
本文对4种钢框架、6种带缝(两排)钢板剪力墙片(四周与构件无连接)和6种固接的钢框架-带缝钢板剪力墙结构在3种不同竖向荷载作用下的抗侧能力和往复荷载下的滞回性能进行了研究,并对比分析。结果表明:前两种结构的侧移刚度、抗侧能力相对较低,屈曲后刚度退化快;钢框架-带缝钢板剪力墙结构的侧移刚度、抗侧能力和耗能能力比前两种结构有明显的提高,说明钢框架与带缝钢板剪力墙片固接后工作协调性能良好。带缝钢板剪力墙片与钢框架-带缝钢板剪力墙结构的整体设计参数宽高比W/H,开缝设计参数开缝墙肢的高宽比h/b、宽厚比b/t、开缝墙肢与剪力墙的高宽比h/H对结构的抗侧能力和滞回性能有很大影响。W/H增大,结构的抗侧能力增强,滞回性能降低;h/b、b/t、h/H增大,结构的抗侧能力降低,滞回性能提高。  相似文献   

19.
联肢钢板剪力墙能通过连梁耗能实现多重抗侧体系,其优良的抗震性能被越来越多的学者研究论证。本文基于能量平衡原理和Chao和Goel提出的弹塑性层剪力分布模式,预设目标侧移及屈服机制等性能参数,归纳出完整的联肢钢板剪力墙结构塑性设计流程,并采用该方法基于8度(0.3g)抗震设防条件下设计了12个联肢钢板剪力墙结构算例。利用有限元分析软件ABAQUS对结构进行了Push-over分析,研究了刚度退化、构件屈服顺序和结构整体变形等方面的结果。结果表明:设计算例能够实现多重抗震机制,并满足预期性能目标。  相似文献   

20.
A two‐story buckling‐restrained brace (BRB) frame was tested under bidirectional in‐plane and out‐of‐plane loading to evaluate the BRB stability and gusset plate design. The test comprised pseudo‐dynamic loadings using the 1999 Chi‐Chi earthquake scaled to the 50%, 10%, and 2% probability of exceedance in 50 years and a cyclic regime of increasing amplitudes of up to 3.0% story drift ratio (SDR). The specimen had a unique configuration where the beams were connected to the columns through shear tabs welded to the column flanges and bolted to the beam webs. Stable hysteretic behavior with only minor cracking at the gusset‐to‐column welds was observed under the pseudo‐dynamic tests, with maximum in‐plane and out‐of‐plane SDRs of 2.24% and 1.47% respectively. Stable behavior continued into the cyclic test where fracture of the gusset‐to‐column welds occurred in the first cycle to simultaneous bidirectional SDR of 3.0%. The observed BRB stability is consistent with a methodology developed for BRB frames under simultaneous in‐plane and out‐of‐plane drifts. The specimen behavior was studied using a finite element model. It was shown that gusset plates are subjected to a combination of BRB force and frame action demands, with the latter increasing the gusset‐to‐beam and gusset‐to‐column interface demands by an average of 69% and 83% respectively. Consistent with the test results, failure at the gusset‐to‐column interfaces is computed when frame action demands are included, thus confirming that not considering frame action demands may results in unconservative gusset plate designs. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏