首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
Storage tanks are vulnerable to earthquakes, as numerous major earthquakes have demonstrated. The trend of recent revisions to make seismic design criteria for large‐scale industrial storage tanks increasingly stringent has made development of cost‐effective earthquake‐resistant design and retrofit techniques for industrial tanks imperative. This study assesses the feasibility of seismic base isolation for making liquid‐filled storage tanks earthquake resistant. The sliding‐type friction pendulum seismic (FPS) bearings are considered rather than the elastomeric bearings because the dynamic characteristics of an FPS‐isolated tank remain unchanged regardless of the storage level. This work has devised a hybrid structural‐hydrodynamic model and solution algorithm, which would permit simple, accurate and efficient assessment of the seismic response of rigid cylindrical storage tanks in the context of seismic isolation. Extensive numerical simulations confirm the effectiveness of seismic base isolation of rigid cylindrical tanks using FPS bearings. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

2.
In this study friction pendulum system (FPS) bearings and precast-prestressed pile (PPP) isolators are considered as base isolation devices for a Chilean confined masonry house. The house is numerically modeled using a multiple degree-of-freedom approach that is calibrated with experimental data. Dynamic behavior of the FPS and PPP isolators is simulated using analytical formulations based on laboratory testing. Optimization of the isolators is performed using an earthquake that is generated to match the design spectrum for the house based on Chilean seismic code. A non-dominated sorting genetic algorithm (NSGA-II) is applied to carry out the optimization. Seismic response of the base-isolated structure subjected to a suite of ground motions is compared to the performance of the traditionally-constructed structure by means of several performance indices (PIs). Numerical simulations indicate that the PPP isolation system is more effective in reducing the base and structural shear, interstory drift, and floor acceleration of the structure than the FPS isolation system, although both systems result in substantial reductions of the response.  相似文献   

3.
The Friction Pendulum System (FPS) isolator is commonly used as a base isolation system in buildings. In this paper, a new tunable FPS (TFPS) isolator is proposed and developed to act as a semi‐active control system by combining the traditional FPS and semi‐active control concept. Theoretical analysis and physical tests were carried out to investigate the behavior of the proposed TFPS isolator. The experimental and theoretical results were in good agreement, both suggesting that the friction force of the TFPS isolator can be tuned to achieve seismic isolation of the structure. A series of numerical simulations of a base‐isolated structure equipped with the proposed TFPS isolator and subjected to earthquake ground motions were also conducted. In the analyses, the linear quadratic regulator (LQR) method was adopted to control the friction force of the proposed TFPS, and the applicability and effectiveness of the TFPS in controlling the structure's seismic responses were investigated. The simulation results showed that the TFPS can reduce the displacement of the isolation layer without significantly increasing the floor acceleration and inter‐story displacement of the superstructure, confirming that the TFPS can effectively control a base‐isolated structure under earthquake ground motions.  相似文献   

4.
Numerical simulations are performed to assess the effects of near-fault ground motions on base-isolated buildings that consist of either lead-rubber (LRB) or friction-pendulum system (FPS) bearings in addition to supplemented viscous dampers. While LRB and FPS isolation systems have been applied for a number of years, the addition of supplemental damping devices is being currently considered for strong ground motions to reduce the isolator displacements. However, the main problem in this case is that the addition of damping may increase both internal deformation and absolute accelerations of the superstructure and thus may defeat many of the gains for which base isolation is intended. In the present paper, a detailed and systematic investigation on the performance of LRB and FPS isolation systems, provided with supplemental viscous damping under the effect of near-fault ground motions, has been carried out by using commercial finite element software.  相似文献   

5.
A common effective method to reduce the seismic response of liquid storage tanks is to isolate them at base using base-isolation systems. It has been observed that in many earthquakes, the foregoing systems significantly affect on the whole system response reduction. However, in exceptional cases of excitation by long-period shaking, the base-isolation systems could have adverse effects. Such earthquakes could cause tank damage due to excessive liquid sloshing. Therefore, the numerical seismic response of liquid storage tanks isolated by bilinear hysteretic bearing elements is investigated under long-period ground motions in this research. For this purpose, finite shell elements for the tank structure and boundary elements for the liquid region are employed. Subsequently, fluid–structure equations of motion are coupled with governing equation of base-isolation system, to represent the whole system behavior. The governing equations of motion of the whole system are solved by an iterative and step-by-step algorithm to evaluate the response of the whole system to the horizontal component of three ground motions. The variations of seismic shear forces, liquid sloshing heights, and tank wall radial displacements are plotted under various system parameters such as the tank geometry aspect ratio (height to radius), and the flexibility of the isolation system, to critically examine the effects of various system parameters on the effectiveness of the base-isolation systems against long-period ground motions. From these analyses, it may be concluded that with the installation of this type of base-isolation system in liquid tanks, the dynamic response of tanks during seismic ground motions can be considerably reduced. Moreover, in the special case of long-period ground motions, the seismic response of base-isolated tanks may be controlled by the isolation system only at particular conditions of slender and broad tanks. For the case of medium tanks, remarkable attentions would be required to be devoted to the design of base-isolation systems expected to experience long-period ground motions.  相似文献   

6.
大型储液罐摩擦摆基底隔震控制分析   总被引:2,自引:1,他引:1  
针对弹性钢制圆柱储液罐,基于Haroun-Housner模型,将连续流体质量等效为3种集中质量,分别为:对流质量、脉冲质量和刚性质量,与这些集中质量连接的相应刚度取值依赖于储罐壁和流体质量.在水平地震激励下,在储罐底部加摩擦单摆支座,给出了简化的液体 - 储罐-隔震支座的力学分析模型,建立了摩擦摆支座基底隔震体系的振动控制方程,并利用Newmark逐步积分法对控制方程进行了数值求解,研究了摩擦摆支座基底隔震的储液罐地震反应,验证了FPB隔震的有效性.  相似文献   

7.
The seismic response of an isolated vertical, cylindrical, extra-large liquefi ed natural gas (LNG) tank by a multiple friction pendulum system (MFPS) is analyzed. Most of the extra-large LNG tanks have a fundamental frequency which involves a range of resonance of most earthquake ground motions. It is an effective way to decrease the response of an isolation system used for extra-large LNG storage tanks under a strong earthquake. However, it is diff icult to implement in practice with common isolation bearings due to issues such as low temperature, soft site and other severe environment factors. The extra-large LNG tank isolated by a MFPS is presented in this study to address these problems. A MFPS is appropriate for large displacements induced by earthquakes with long predominant periods. A simplifi ed fi nite element model by Malhotra and Dunkerley is used to determine the usefulness of the isolation system. Data reported and statistically sorted include pile shear, wave height, impulsive acceleration, convective acceleration and outer tank acceleration. The results show that the isolation system has excellent adaptability for different liquid levels and is very effective in controlling the seismic response of extra-large LNG tanks.  相似文献   

8.
This paper investigates numerically the seismic response of six seismically base‐isolated (BI) 20‐story reinforced concrete buildings and compares their response to that of a fixed‐base (FB) building with a similar structural system above ground. Located in Berkeley, California, 2 km from the Hayward fault, the buildings are designed with a core wall that provides most of the lateral force resistance above ground. For the BI buildings, the following are investigated: two isolation systems (both implemented below a three‐story basement), isolation periods equal to 4, 5, and 6 s, and two levels of flexural strength of the wall. The first isolation system combines tension‐resistant friction pendulum bearings and nonlinear fluid viscous dampers (NFVDs); the second combines low‐friction tension‐resistant crosslinear bearings, lead‐rubber bearings, and NFVDs. The designs of all buildings satisfy ASCE 7‐10 requirements, except that one component of horizontal excitation, is used in the 2D nonlinear response history analysis. Analysis is performed for a set of ground motions scaled to the design earthquake and to the maximum considered earthquake (MCE). At both the design earthquake and the MCE, the FB building develops large inelastic deformations and shear forces in the wall and large floor accelerations. At the MCE, four of the BI buildings experience nominally elastic response of the wall, with floor accelerations and shear forces being 0.25 to 0.55 times those experienced by the FB building. The response of the FB and four of the BI buildings to four unscaled historical pulse‐like near‐fault ground motions is also studied. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
将摩擦摆(FPS)引入到网壳结构的隔震控制中。文中首先阐明了FPS的工作机理和本构关系,建立了FPS隔震网壳结构的振动方程。通过双层球面网壳结构的数值算例考察了隔震和无控结构在单向和三向地震作用下的振动响应以及FPS的控制效果。研究结果表明,FPS具有良好的隔震和耗能效果,可有效地应用于球面网壳结构的振动控制。  相似文献   

10.
This experimental investigation deals with the earthquake behaviour of a nominally symmetric and a mass‐asymmetric three‐storey structural model isolated with the frictional pendulum system (FPS). Both accidental and natural torsion are evaluated in the structure by using recorded accelerations in all building floors and measured deformations at the isolation level. A 3D‐shaking table was used to subject the model to five different ground motions, including impulsive as well as far‐field subduction‐zone type earthquakes. Results show that the analytical predictions of the earthquake behaviour of the isolated structure, as obtained from a physical model of the FPS, are in close agreement with the true complex inelastic measured behaviour of the FPS. Besides, experimental results also validate previous observations about the importance of accounting for the variability of the normal loads in modelling the earthquake behaviour of FPS isolators. Measured torsional deformation amplifications at the base of the building vary, in the mean, from 2.5% to 6% for the symmetric and asymmetric structural configurations, respectively. In relation to the fixed base structure, the reduction factors for the base shear of the isolated structure are, in the mean, about 3.9 for both configurations. Finally, it is concluded that the FPS is capable of controlling the lateral–torsional motions of mass‐asymmetric structures quite effectively by aligning the centre of mass of the superstructure with the centre of pendular and frictional resistance of the isolation system. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

11.
近断层地震动中长周期、短持时和高能量的加速度脉冲将对高层摩擦摆基础隔震结构的减震性能产生不利影响,考虑土-结构相互作用(SSI效应)后的隔震结构将产生动力耦合效应,可能进一步放大隔震结构地震响应。为此,通过一幢框架-核心筒高层摩擦摆基础隔震结构的非线性地震响应分析,考察近断层脉冲型地震动作用下框架-核心筒摩擦摆基础隔震结构的层间位移角、楼层加速度和隔震层变形等响应规律,揭示隔震体系的损伤机理。基于集总参数SR (sway-rocking)模型,分析不同场地类别与不同地震动类型对隔震体系动力响应影响规律。结果表明:高层摩擦摆基础隔震结构在近断层脉冲型地震动作用下的减震效果相比普通地震动减震效果变差,楼层剪力、层间位移角和隔震层变形等超越普通地震动作用下的1.5倍;对于Ⅲ和Ⅳ类场地类别,考虑SSI效应使隔震结构的地震响应进一步放大,弹塑性层间位移角随着土质变软增大尤为明显。  相似文献   

12.
实际地震具有多维特性,只考虑水平向作用往往不够真实全面,而且远场长周期地震动不同于普通地震动,具有周期长、持时长、低频成份丰富等特征,对周期较大的隔震类结构会产生不利影响,在考虑SSI效应(soil-structure interaction, SSI)中尤为复杂,需深入探讨。基于此,建立大底盘层间隔震结构,在三维地震动激励下,探讨普通地震与远场长周期地震对层间隔震结构的不同影响,并分析考虑SSI效应对结构的不同程度影响。结果表明:三维地震下,远场长周期对层间隔震结构产生的地震响应远大于普通地震;考虑SSI效应时,随着土体变软,结构响应增大;针对传统水平隔震支座,在三维远场长周期地震下出现层间位移角和支座位移超限问题,设置三维隔震支座,解决了超限问题,分析结果表明其隔减震效果明显优于传统水平隔震支座。  相似文献   

13.
摩擦摆支座在单层球面网壳结构中的隔震分析   总被引:1,自引:1,他引:1  
将摩擦摆支座(FPS)应用于单层球面网壳结构的隔震,给出了隔震网壳结构的运动方程。通过对比分析不同强度地震动输入条件下的结构动力响应特征,考察了FPS支座应用于网壳结构隔震的有效性和适用性。研究结果表明,在不同强度的地震动作用下,隔震结构的节点加速度峰值和杆件轴力峰值都得到了有效控制,且地震动强度越大,控制效果越好。  相似文献   

14.
A full‐scale 5‐story steel moment frame building was subjected to a series of earthquake excitations using the E‐Defense shake table in August, 2011. For one of the test configurations, the building was seismically isolated by a hybrid system of lead‐rubber bearings and low friction roller bearings known as cross‐linear bearings, and was designed for a very rare 100 000‐year return period earthquake at a Central and Eastern US soil site. The building was subject to 15 trials including sinusoidal input, recorded motions and simulated earthquakes, 2D and 3D input, and a range of intensities including some beyond the design basis level. The experimental program was one of the first system‐level full‐scale validations of seismic isolation and the first known full‐scale experiment of a hybrid isolation system incorporating lead‐rubber and low friction bearings. Stable response of the hybrid isolation system was demonstrated at displacement demands up to 550 mm and shear strain in excess of 200%. Torsional amplifications were within the new factor stipulated by the code provisions. Axial force was observed to transfer from the lead‐rubber bearings to the cross‐linear bearings at large displacements, and the force transfer at large displacements exceeded that predicted by basic calculations. The force transfer occurred primarily because of the flexural rigidity of the base diaphragm and the larger vertical stiffness of the cross‐linear bearings relative to the lead‐rubber bearings.  相似文献   

15.
Because a conventional isolation system with constant isolation frequency is usually a long‐period dynamic system, its seismic response is likely to be amplified in earthquakes with strong long‐period wave components, such as near‐fault ground motions. Seismic isolators with variable mechanical properties may provide a promising solution to alleviate this problem. To this end, in this work sliding isolators with variable curvature (SIVC) were studied experimentally. An SIVC isolator is similar to a friction pendulum system (FPS) isolator, except that its sliding surface has variable curvature rather being spherical. As a result, the SIVC's isolation stiffness that is proportional to the curvature becomes a function of the isolator displacement. By appropriately designing the geometry of the sliding surface, the SIVC is able to possess favorable hysteretic behavior. In order to prove the applicability of the SIVC concept, several prototype SIVC isolators, whose sliding surfaces are defined by a sixth‐order polynomial function, were fabricated and tested in this study. A cyclic element test on the prototype SIVC isolators and a shaking table test on an SIVC isolated steel frame were all conducted. The results of both tests have verified that the prototype SIVC isolators do indeed have the hysteretic property of variable stiffness as prescribed by the derived formulas in this study. Moreover, it is also demonstrated that the proposed SIVC is able to effectively reduce the isolator drift in a near‐fault earthquake with strong long‐period components, as compared with that of an FPS system with the same friction coefficient. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
研究不同高径比橡胶基底隔震储罐的频率特征,探讨储罐隔震体系3种不同振动频率随支座隔震频率变化规律.分析在不同频谱特性地震波激励下,隔震体系各振型组分对地震响应(基底剪力、支座位移和晃动波高)的影响,以及响应峰值随支座隔震频率和阻尼比的变化特点.研究表明,基底剪力峰值与场地地震波频谱特性密切相关.支座隔震频率不能完全反映减震机理的实质,隔震振型频率是影响基底剪力的重要参数.在软弱场地上隔震储罐的减震效率低,有效隔震频率范围窄.晃动波高峰值是储罐自振特性和地震波频谱特性等多种因素导致的结果,隔震系统设计时需特别考虑晃动波高增大的影响.  相似文献   

17.
Overturning of a structure causes variations in the normal loads of the isolators supporting that structure. For frictional isolators, such variation leads to changes in the frictional forces developed and, hence, in the strength distribution in plan. For frictional pendulum system (FPS) isolators, it also causes changes in the pendular action, i.e. in the stiffness distribution of the isolation interface. Therefore, although the structure is nominally symmetric it develops lateral–torsional coupling when it is subjected to two horizontal components of ground motion. This coupling is denoted herein as accidental torsion due to overturning, and its effect in the earthquake response of nominally symmetric structures is evaluated. Several parameters are identified to control this coupling, but the most important are the slenderness of the structure and the aspect ratio of the building plan. Results are presented in terms of the torsional amplification of the deformations of the isolation base and the interstorey deformations of the superstructure. The FPS system is modelled accurately by including true large deformations and the potential uplift and impact of the isolators. Impulsive as well as subduction‐type ground motions are considered in the analysis, but results show small differences between them. An upper bound for the mean‐plus‐one standard deviation values of the torsional amplifications for the base due to this accidental torsion is 5%. This implies that for design purposes of the isolation system such increase in deformations could probably be neglected. However, the same amplification for the interstorey deformations may be as large as 50%, depending on the torsional stiffness and slenderness of the superstructure, and should be considered in design. In general, such amplification of deformations decreases for torsionally stiffer structures and smaller height‐to‐base aspect ratios. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

18.
杨迪雄  赵岩 《地震学报》2010,32(5):579-587
选择台湾集集地震和美国北岭地震的近断层地震动记录作为输入,考察了近断层地震动破裂向前方向性与滑冲效应引起的两种不同速度脉冲运动对单自由度体系和长周期橡胶支座隔震建筑结构抗震性能的影响.反应谱分析表明,破裂向前方向性与滑冲效应对工程结构地震响应的影响是随结构周期变化的.在中短周期段,含破裂向前方向性效应地震动的谱加速度值大于含滑冲效应地震动的谱加速度值;而在长周期段,含滑冲效应地震动的谱加速度大于含破裂向前方向性效应的谱加速度值.并且,与无脉冲地震动作用相比,含破裂向前方向性与滑冲效应脉冲的近断层地震动作用下隔震建筑的地震响应显著增大.滑冲效应引起的速度脉冲使隔震建筑底部的层间变形和楼层剪力明显增大,这意味着滑冲效应脉冲比向前方向性效应脉冲对长周期建筑结构的破坏更具危害性.  相似文献   

19.
<正>A theoretical model of a friction pendulum system(FPS) is introduced to examine its application for the seismic isolation of spatial lattice shell structures.An equation of motion of the lattice shell with FPS bearings is developed.Then, seismic isolation studies are performed for both double-layer and single-layer lattice shell structures under different seismic input and design parameters of the FPS.The influence of frictional coefficients and radius of the FPS on seismic performance are discussed.Based on the study,some suggestions for seismic isolation design of lattice shells with FPS bearings are given and conclusions are made which could be helpful in the application of FPS.  相似文献   

20.
Seismic fragility curves for fixed-base and base-isolated liquid storage tanks are developed under non-stationary earthquakes, and their seismic performance are compared. The correlation between different earthquake intensity measure (IM) parameters and peak response quantities of the base-isolated liquid storage tanks are investigated. The failure criteria are chosen based on (1) the elastic buckling strength of the tank wall, which is defined in terms of critical base shear and critical overturning moment, and (2) in terms of the critical isolation displacement. The uncertainty involved is considered in the earthquake characteristics. Non-stationary earthquake ground motions are generated using Monte Carlo (MC) simulation. Influence of the isolator characteristic parameters and modeling approaches on the seismic fragility of the base-isolated liquid storage tanks is also investigated. Peak ground acceleration is found to be the well correlated IM parameter with the peak response quantities of the base-isolated liquid storage tanks. Substantial decrease in the seismic fragility of the base-isolated liquid storage tanks is observed as compared to the fixed-base tanks. Significant influence of the isolator characteristic parameters on the seismic fragility of the base-isolated liquid storage tanks are reported in the present study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号