首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
This paper aims to assess the seismic fragility of vehicle-bridge-interaction (VBI) systems considering the effects of vehicle types, traffic conditions, and road surface qualities. A stochastic nonlinear mechanical model for the earthquake-VBI system is developed, and the fragility functions for the proposed VBI model are derived by considering the relevant probabilistic seismic demand parameters. On the basis of a typical four-span continuous prestressed concrete highway bridge in China, a complete numerical model for the VBI system is built considering multiple uncertainties from bridge and vehicle parameters, as well as the road surface qualities. A total of 120 real ground motion records with different combinations of magnitude-source-to-site distance (M-R) and earthquake intensity characteristics are selected. Meanwhile, 80 scenarios in terms of different combinations of vehicle types, vehicle speeds, and road surface irregularities are defined. In this context, 96,000 nonlinear time-history analyses are performed, and the developed fragility models are applied to the VBI system at both component and system levels. Results indicate that the fragilities of pier drift, bearing shear strain, and the overall VBI system increase with the increase of the vehicle weight or the decrease of the vehicle speed, while the vertical deck displacement is dominated by the vehicle weight. It is also found that the road surface quality has a negligible effect on both component and system fragilities.  相似文献   

2.
Probabilistic risk analysis is an effective tool for risk-informed decision-making related to the building facilities. All sources of the uncertainties should be considered in seismic risk assessment framework. Not only the levels of these uncertainties but also the effects on the performance of the buildings should be clearly identified. This paper aims to assess the impacts of the potential uncertainties on the seismic risk of steel frame equipped with steel panel wall (SPWF). Firstly, the performance limits of the SPWF structures are determined according to cyclic test results of two SPWF specimens. Then a validated numerical model of a 12-story SPWF building is modeled and used to perform the nonlinear time-history analysis, and the record-to-record uncertainty is identified by a set of ground motions derived from SAC project. Furthermore, comparisons are made on fragility curves for the building with or without considering the combining uncertainties in structural system, in defining performance limits and modeling technology. Finally, the annual probability and probability in 50 years for each performance limit is calculated and compared. The impacts of such uncertainties on seismic risk of SPWF building are quantified for risk-informed evaluation of the SPWF buildings.  相似文献   

3.
This study deals with the seismic fragility of elastic structural systems equipped with single concave sliding (friction pendulum system (FPS)) isolators considering different soil conditions. The behavior of these systems is analyzed by employing a two-degree-of-freedom model, whereas the FPS response is described by means of a velocity-dependent model. The uncertainty in the seismic inputs is taken into account by considering artificial seismic excitations modelled as timemodulated filtered Gaussian white noise random processes of different intensity within the power spectral density method. In particular, the filter parameters, which control the frequency content of the random excitations, are calibrated to describe stiff, medium and soft soil conditions. The sliding friction coefficient at large velocity is also considered as a random variable modelled through a uniform probability density function. Incremental dynamic analyses are developed in order to evaluate the probabilities of exceeding different limit states related to both the reinforced concrete (RC) superstructure and isolation level, defining the seismic fragility curves within an extensive parametric study carried out for different structural system properties and soil conditions. The abovementioned seismic fragility curves are useful to evaluate the seismic reliability of base-isolated elastic systems equipped with FPS and located in any site for any soil condition.  相似文献   

4.
The paper illustrates a probabilistic methodology for assessing the vulnerability of existing reinforced concrete (RC) buildings with limited ductility capacity retrofitted by means of dissipative braces. The aim is to highlight the most important parameters controlling the capacity of these coupled systems and specific aspects concerning the response uncertainties. The proposed methodology is based on the use of local engineering demand parameters for monitoring the seismic response and on the development of component and system fragility curves before and after the retrofit. In the first part of the paper, the methodology is illustrated by highlighting its advantages with respect to the existing approaches. Then, its capability and effectiveness are tested by considering a benchmark two‐dimensional RC frame designed for gravity‐loads only. The frame is retrofitted by introducing elasto‐plastic dissipative braces designed for different levels of base shear capacity. The obtained results show the effectiveness of the methodology in describing the changes in the response and in the failure modalities before and after the retrofit, for different retrofit levels. Moreover, the retrofit effectiveness is evaluated by introducing proper synthetic parameters describing the fragility curves and by stressing the importance of employing local engineering demand parameters (EDPs) rather than global EDPs in the seismic risk evaluation of coupled systems consisting in low‐ductility RC frames and dissipative braces. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
Modelling uncertainty can significantly affect the structural seismic reliability assessment. However, the limit state excursion due to this type of uncertainty may not be described by a Poisson process as it lacks renewal properties with the occurrence of each earthquake event. Furthermore, considering uncertainties related to ground motion representation by employing recorded ground motions together with modelling uncertainties is not a trivial task. Robust fragility assessment, proposed previously by the authors, employs the structural response to recorded ground motion as data in order to update prescribed seismic fragility models. Robust fragility can be extremely efficient for considering also the structural modelling uncertainties by creating a dataset of one-to-one assignments of structural model realizations and as-recorded ground motions. This can reduce the computational effort by more than 1 order of magnitude. However, it should be kept in mind that the fragility concept itself is based on the underlying assumption of Poisson-type renewal. Using the concept of updated robust reliability, considering both the uncertainty in ground motion representation based on as-recorded ground motion and non ergodic modelling uncertainties, the error introduced through structural reliability assessment by using the robust fragility is quantified. It is shown through specific application to an existing RC frame that this error is quite small when the product of the time interval and the standard deviation of failure rate is small and is on the conservative side.  相似文献   

6.
现役古建木结构普遍存在残损现象,这将影响结构的抗震性能。本文以北京故宫的咸福宫西配殿为研究对象,通过简化其屋顶、斗拱、榫卯和柱脚节点建立结构的理想模型,并在此基础上考虑材料老化和节点性能降低等因素建立其残损现状模型。通过地震易损性分析,得到古建木结构的地震易损性曲线并进行理想和残损结构的震害等级及其发生概率对比。研究结果表明:残损现象降低了咸福宫西配殿的刚度和自振频率;相比于理想结构,咸福宫西配殿残损结构在小震作用下发生轻微损坏的概率增大21.1%,在中震作用下发生中等破坏的概率增大3.7%,大震作用下发生严重破坏的概率增大10.6%;咸福宫西配殿在大震作用下发生倒塌的概率很小,体现了木结构具有良好的抗震性能。  相似文献   

7.
Seismic hazard levels lower than those for design of new buildings have been permitted for seismic evaluation and retrofit of existing buildings due to the relatively short remaining lifespans. The seismic hazard reduction enables costeffective seismic evaluation and retrofit of existing buildings with limited structural capacity. The current study proposes seismic hazard reduction factors for Korea, one of low to moderate seismicity regions. The seismic hazard reduction factors are based on equal probabilities of non-exceedance within different remaining building lifespans. A validation procedure is proposed to investigate equality of seismic risk in terms of ductility-based limit states using seismic fragility assessment of nonlinear SDOF systems, of which retrofit demands are determined by the displacement coefficient method of ASCE 41-13 for different target remaining building lifespans and corresponding reduced design earthquakes. Validation result shows that the use of seismic hazard reduction factors can be permitted in conjunction with appropriate lower bounds of the remaining building lifespans.  相似文献   

8.
The lack of knowledge concerning modelling existing buildings leads to significant variability in fragility curves for single or grouped existing buildings. This study aims to investigate the uncertainties of fragility curves, with special consideration of the single-building sigma. Experimental data and simplified models are applied to the BRD tower in Bucharest, Romania, a RC building with permanent instrumentation. A three-step methodology is applied: (1) adjustment of a linear MDOF model for experimental modal analysis using a Timoshenko beam model and based on Anderson's criteria, (2) computation of the structure's response to a large set of accelerograms simulated by SIMQKE software, considering twelve ground motion parameters as intensity measurements (IM), and (3) construction of the fragility curves by comparing numerical interstory drift with the threshold criteria provided by the Hazus methodology for the slight damage state. By introducing experimental data into the model, uncertainty is reduced to 0.02 considering Sd ) as seismic intensity IM and uncertainty related to the model is assessed at 0.03. These values must be compared with the total uncertainty value of around 0.7 provided by the Hazus methodology.  相似文献   

9.
A fundamental tool in seismic risk assessment of transportation systems is the fragility curve, which describes the probability that a structure will reach or exceed a certain damage state for a given ground motion intensity. Fragility curves are usually represented by two‐parameter (median and log‐standard deviation) cumulative lognormal distributions. In this paper, a numerical approach, in the spirit of the IDA, is applied for the development of fragility curves for highways and railways on embankments and in cuts due to seismic shaking. The response of the geo‐construction to increasing levels of seismic intensity is evaluated using a 2D nonlinear finite element model, with an elasto‐plastic criterion to simulate the soil behavior. A calibration procedure is followed in order to account for the dependency of both the stiffness and the damping to the soil strain level. The effect of soil conditions and ground motion characteristics on the response of the embankment and cut is taken into account considering different typical soil profiles and seismic input motions. This study will provide input for the assessment of the vulnerability of the road/railway network regarding the performance of the embankments and cuts; therefore, the level of damage is described in terms of the permanent ground displacement in these structures. The fragility curves are estimated based on the evolution of damage with increasing earthquake intensity, which is described by PGA. The proposed approach allows the evaluation of new fragility curves considering the distinctive features of the element's geometry, the input motion, and the soil properties as well as the associated uncertainties. A relationship between the computed permanent ground displacement on the surface of the embankment and the PGA in the free field is also suggested based on the results of the numerical analyses. Finally, the proposed fragility curves are compared with existing empirical data and the limitations of their applicability are outlined. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
A wide number of experimental studies conducted in latest years pointed out the high influence of the mechanical properties of masonry units and mortar bed joints on lateral strength and stiffness of masonry panels. This feature significantly modifies the global response of infilled frames under seismic actions as well as the local interaction phenomena. Despite a wide investigation on the influence of the infills on global behaviour of reinforced concrete (RC) frames has already been provided, different features characterizing the seismic performances of buildings suggest the need of accurately evaluating local interaction phenomena as well as the influence of the panel on specific and relevant aspects, as the accelerations transferred to non-structural components. This study provides a parametrical analysis of the influence of shear strength and elastic modulus of masonry infills on the seismic behaviour of RC frames originally designed for gravity loads. Regular buildings with different height were analysed using the Incremental Dynamic Analysis in order to provide fragility curves, investigate on the collapse mechanisms and define the floor spectra depending on the properties of the infills. Results obtained pointed out the high influence of the considered parameters on the fragility of existing RC frames, often characterized by inadequate transversal reinforcement of columns, which may lead to brittle failure due to the interaction with the infills. Floor response spectra are also significantly affected by the influence of masonry infills both in terms of shape and maximum spectral accelerations. Lastly, on the basis of the observed failure mechanisms, a parameter defining the ductility of the frames depending on the properties of the infills was also provided (Capacity Design Factor). The correlation between the mechanical properties of the infills and this parameter suggests its reliability in the simplified vulnerability analysis of existing buildings as well as for the design of new buildings.  相似文献   

11.
The aim of this work is to propose seismic reliability‐based relationships between the strength reduction factors and the displacement ductility demand of nonlinear structural systems equipped with friction pendulum isolators (FPS) depending on the structural properties. The isolated structures are described by employing an equivalent 2dof model characterized by a perfectly elastoplastic rule to account for the inelastic response of the superstructure, whereas, the FPS behavior is described by a velocity‐dependent model. An extensive parametric study is carried out encompassing a wide range of elastic and inelastic building properties, different seismic intensity levels and considering the friction coefficient as a random variable. Defined a set of natural seismic records and scaled to the seismic intensity corresponding to life safety limit state for L'Aquila site (Italy) according to NTC08, the inelastic characteristics of the superstructures are designed as the ratio between the average elastic responses and increasing strength reduction factors. Incremental dynamic analyses (IDAs) are developed to evaluate the seismic fragility curves of both the inelastic superstructure and the isolation level assuming different values of the corresponding limit states. Integrating the fragility curves with the seismic hazard curves related to L'Aquila site (Italy), the reliability curves of the equivalent inelastic base‐isolated structural systems, with a design life of 50 years, are derived proposing seismic reliability‐based regression expressions between the displacement ductility demand and the strength reduction factors for the superstructure as well as seismic reliability‐based design (SRBD) abacuses useful to define the FPS properties. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
为考虑核电厂结构参数不确定对结构地震易损性的影响,基于一次二阶矩法(First-Order Second-Moment, FOSM)进行地震易损性分析。以核电结构中混凝土材料的密度、弹性模量,泊松比和抗拉强度为不确定参数,建立有限元模型,并与试验结果对比,以验证模型的准确性。基于有限元数值模拟方法,通过增量动力法计算核电厂模型在多条地震记录下不同峰值加速度的动力响应,同时基于FOSM得到参数不确定下的对数标准差,进而得到核电厂结构考虑参数不确定的地震易损性曲线。结果表明,结构参数的不确定对核电结构有一定的影响,未考虑参数不确定的地震易损性结果会低估结构的失效概率。该方法可为核电结构基于参数不确定下的易损性分析提供一定的理论依据与实用价值。  相似文献   

13.
Following several damaging earthquakes in China,research has been devoted to find the causes of the collapse of reinforced concrete(RC) building sand studying the vulnerability of existing buildings.The Chinese Code for Seismic Design of Buildings(CCSDB) has evolved over time,however,there is still reported earthquake induced damage of newly designed RC buildings.Thus,to investigate modern Chinese seismic design code,three low-,mid-and high-rise RC frames were designed according to the 2010 CCSDB and the corresponding vulnerability curves were derived by computing a probabilistic seismic demand model(PSDM).The PSDM was computed by carrying out nonlinear time history analysis using thirty ground motions obtained from the Pacific Earthquake Engineering Research Center.Finally,the PSDM was used to generate fragility curves for immediate occupancy,significant damage,and collapse prevention damage levels.Results of the vulnerability assessment indicate that the seismic demands on the three different frames designed according to the 2010 CCSDB meet the seismic requirements and are almost in the same safety level.  相似文献   

14.
梁丹  梁兴文 《地震工程学报》2015,37(4):1060-1065,1072
选取按照现行规范设计的既有建筑进行有限元建模,考虑地震动的不确定性对其进行大量增量动力分析(IDA),得到模型的IDA曲线簇。在此基础上对其进行地震需求概率分析和概率抗震能力分析,拟合得到结构的易损性曲线,据此对结构的倒塌概率进行定量评估,并比较基于非线性分析与性能评估软件PERFORM-3D的纤维模型和塑性铰模型的分析结果。结果表明:按照我国现行规范设计的钢筋混凝土(RC)框架结构,在预期的罕遇地震作用下倒塌概率较小,可满足"大震不倒"的要求;基于PERFORM-3D的截面纤维模型所得的RC框架结构,经非线性分析所得的倒塌概率相对保守,安全储备更高。  相似文献   

15.
A comprehensive parametric study on the inelastic seismic response of seismically isolated RC frame buildings, designed for gravity loads only, is presented. Four building prototypes, with 23 m × 10 m floor plan dimensions and number of storeys ranging from 2 to 8, are considered. All the buildings present internal resistant frames in one direction only, identified as the strong direction of the building. In the orthogonal weak direction, the buildings present outer resistant frames only, with infilled masonry panels. This structural configuration is typical of many existing RC buildings, realized in Italy and other European countries in the 60s and 70s. The parametric study is based on the results of extensive nonlinear response‐time history analyses of 2‐DOF systems, using a set of seven artificial and natural seismic ground motions. In the parametric study, buildings with strength ratio (Fy/W) ranging from 0.03 to 0.15 and post‐yield stiffness ratio ranging from 0% to 6% are examined. Three different types of isolation systems are considered, that is, high damping rubber bearings, lead rubber bearings and friction pendulum bearings. The isolation systems have been designed accepting the occurrence of plastic hinges in the superstructure during the design earthquake. The nonlinear response‐time history analyses results show that structures with seismic isolation experience fewer inelastic cycles compared with fixed‐base structures. As a consequence, although limited plastic deformations can be accepted, the collapse limit state of seismically isolated structures should be based on the lateral capacity of the superstructure without significant reliance on its inherent hysteretic damping or ductility capacity. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
This paper outlines the seismic vulnerability of rural stone masonry buildings affected by the 2015 Gorkha earthquake sequence. Summary of field observation is presented first and empirical fragility curves are developed from the detailed damage assessment data from 603 villages in central, eastern and western Nepal. Fragility curves are developed on the basis of 665,515 building damage cases collected during the post-earthquake detailed damage assessment campaign conducted by Government of Nepal. Two sets of fragility functions are derived using peak ground acceleration and spectral acceleration at 0.3 s as the intensity measures. The sum of the results highlights that stone masonry buildings in Nepal are highly vulnerable even in the case of low to moderate ground shaking. The results further indicate that in the case of strong to major earthquakes, most of the stone masonry buildings in Nepal would sustain severe damage or collapse.  相似文献   

17.
The assessment of earthquake loss often requires the definition of a relation between a measure of damage and a quantity of loss, usually achieved through the employment of a damage‐to‐loss model. These models are frequently characterized by a large variability, which inevitably increases the uncertainty in the vulnerability assessment and earthquake loss estimation. This study provides an insight on the development of damage‐to‐loss functions for moment‐frame reinforced concrete buildings through an analytical methodology. Tri‐dimensional finite element models of existing reinforced concrete buildings were subjected to a number of ground motion records compatible with the seismicity in the region of interest, through nonlinear dynamic analysis. These results were used to assess, for a number of damage states, the probability distribution of loss ratio, taking into consideration member damage and different repair techniques, as well as to derive sets of fragility functions. Then, a vulnerability model (in terms of the ratio of cost of repair to cost of replacement, conditional on the level of ground shaking intensity) was derived and compared with the vulnerability functions obtained through the combination of various damage‐to‐loss models with the set of fragility functions developed herein. In order to provide realistic estimates of economic losses due to seismic action, a comprehensive study on repair costs using current Portuguese market values was also carried out. The results of this study highlight important issues in the derivation of vulnerability functions, which are a fundamental component for an adequate seismic risk assessment. © 2015 The Authors. Earthquake Engineering & Structural Dynamics published by John Wiley & Sons Ltd.  相似文献   

18.
Generation of hazard-consistent fragility curves   总被引:1,自引:0,他引:1  
This paper presents an analytical method for generating fragility curves of structures. In the proposed method, seismic sources, path attenuation, local soil conditions, and nonlinear building behavior are systematically considered. The uncertainties in the earthquake-site-structure system are quantified by considering the uncertainties in the seismic, site, and structural parameters that define the system. For an illustration, the proposed method is used to generate fragility curves and a damge probability matrix for Smith Hall on the main campus of The University of Memphis, Memphis, Tennessee.  相似文献   

19.
根据我国现行的建筑结构抗震规范,无论是新建建筑结构的抗震设计还是既有建筑结构的抗震评估与加固,均通过小震弹性承载力计算 抗震延性构造措施来达到"小震不坏、中震可修、大震不倒"的抗震设防目标(对于不规则且具有明显薄弱部位的建筑结构还需要进行罕遇地震作用下的弹塑性层间变形验算)。对于抗震延性构造措施不满足现行规范的既有建筑结构的评估、改建、扩建,如果仅通过小震弹性的承载力计算,显然无法达到"大震不倒"的目标。本文通过引入国际上先进的基于性能的结构抗震思想,以结构层间位移和结构构件变形作为性能目标,从定量上解决了既有钢筋混凝土建筑结构的抗震评估与加固问题。  相似文献   

20.
Non‐ductile reinforced concrete buildings represent a prevalent construction type found in many parts of the world. Due to the seismic vulnerability of such buildings, in areas of high seismic activity non‐ductile reinforced concrete buildings pose a significant threat to the safety of the occupants and damage to such structures can result in large financial losses. This paper introduces advanced analytical models that can be used to simulate the nonlinear dynamic response of these structural systems, including collapse. The state‐of‐the‐art loss simulation procedure developed for new buildings is extended to estimate the expected losses of existing non‐ductile concrete buildings considering their vulnerability to collapse. Three criteria for collapse, namely first component failure, side‐sway collapse, and gravity‐load collapse, are considered in determining the probability of collapse and the assessment of financial losses. A detailed example is presented using a seven‐story non‐ductile reinforced concrete frame building located in the Los Angeles, California. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号