首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
Hysteretic dampers are used to dissipate earthquake‐induced energy in base‐isolated structures by acquiring inelastic deformations, rendering their hysteretic behavior of vital importance. The present paper focuses on investigating the behavior of U‐shaped steel dampers under bidirectional loading; this is significantly different from their corresponding uniaxial behavior. Two main sets of loading tests on full‐scale specimens are conducted in this regard: (i) quasi‐static tests with simple histories and (ii) dynamic tests with realistic loading histories. Based on the results obtained in the quasi‐static tests, an interaction curve that accounts for the reduction of the cyclic deformation capacity is proposed. However, the fidelity of this relation must be assessed under loading conditions similar to those of a seismically isolated structure subjected to an earthquake, which represents the goal of the second set of tests. The results of the dynamic tests validate the proposed interaction curve for estimating the deformation capacity of U‐shaped steel dampers under bidirectional loading. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
A reliable performance of anti‐seismic devices when the upper‐structure is subjected to strong biaxial seismic excitation is of vital importance to ensure the latter doesn't reach critical behavior. U‐shaped steel dampers are hysteretic devices used to dissipate the earthquake‐induced energy of base‐isolated structures. In the framework of performance‐based design, which is gaining more and more recognition, it is of particular importance to assess the performance of base‐isolated structures with such dampers under different intensity levels of bidirectional ground motion. To achieve this goal, an analytical model able to simulate the bidirectional displacement response of an isolation system is adopted. Incremental dynamic analysis (IDA) is used to obtain the relation between the earthquake‐induced bidirectional damage of U‐shaped steel dampers and different intensity levels of the considered records. The performance of the dampers is categorized into 5 levels delimited by 4 limit states for which fragility curves are derived. The results obtained using the bidirectional approach are quantitatively compared to those given by employing an in‐plane model (widely used in current design practices in Japan) with the purpose of assessing whether the latter provides unconservative estimates of the performance of the dampers. The main conclusion is that, for large seismic intensities, the safety margin against fracture of the dampers is significantly overestimated when an in‐plane model is adopted. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

3.
Passive energy dissipation devices are increasingly implemented in frame structures to improve their performance under seismic loading. Most guidelines for designing this type of system retain the requirements applicable to frames without dampers, and this hinders taking full advantage of the benefits of implementing dampers. Further, assessing the extent of damage suffered by the frame and by the dampers for different levels of seismic hazard is of paramount importance in the framework of performance‐based design. This paper presents an experimental investigation whose objectives are to provide empirical data on the response of reinforced concrete (RC) frames equipped with hysteretic dampers (dynamic response and damage) and to evaluate the need for the frame to form a strong column‐weak beam mechanism and dissipate large amounts of plastic strain energy. To this end, shake‐table tests were conducted on a 2/5‐scale RC frame with hysteretic dampers. The frame was designed only for gravitational loads. The dampers provided lateral strength and stiffness, respectively, three and 12 times greater than those of the frame. The test structure was subjected to a sequence of seismic simulations that represented different levels of seismic hazard. The RC frame showed a performance level of ‘immediate occupancy’, with maximum rotation demands below 20% of the ultimate capacity. The dampers dissipated most of the energy input by the earthquake. It is shown that combining hysteretic dampers with flexible reinforced concrete frames leads to structures with improved seismic performance and that requirements of conventional RC frames (without dampers) can be relieved. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
Cable‐stayed bridges require a careful consideration of the lateral force exerted by the deck on the towers under strong earthquakes. This work explores the seismic response of cable‐stayed bridges with yielding metallic dampers composed of triangular plates that connect the deck with the supports in the transverse direction. A design method based on an equivalent single‐degree of freedom approximation is proposed. This is proved valid for conventional cable‐stayed bridges with 200‐ and 400‐m main spans, but not 600 m. The height of the plates is chosen to (1) achieve a yielding capacity that limits the maximum force transmitted from the deck to the towers, and to (2) control the hysteretic energy that the dampers dissipate by defining their design ductility. In order to select the optimal ductility and the damper configuration, a multi‐objective response factor that accounts for the energy dissipation, peak damper displacement and low‐cycle fatigue is introduced. The design method is applied to cable‐stayed bridges with different spans and deck–support connections. The results show that the dissipation by plastic deformation in the dampers prevents significant damage in the towers of the short‐to‐medium‐span bridges under the extreme seismic actions. However, the transverse response of the towers in the bridge with a 600‐m main span is less sensitive to the dampers. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

5.
This paper evaluates the hysteretic behavior of an innovative compressed elastomer structural damper and its applicability to seismic‐resistant design of steel moment‐resisting frames (MRFs). The damper is constructed by precompressing a high‐damping elastomeric material into steel tubes. This innovative construction results in viscous‐like damping under small strains and friction‐like damping under large strains. A rate‐dependent hysteretic model for the compressed elastomer damper, formed from a parallel combination of a modified Bouc–Wen model and a non‐linear dashpot is presented. The model is calibrated using test data obtained under sinusoidal loading at different amplitudes and frequencies. This model is incorporated in the OpenSees [17] computer program for use in seismic response analyses of steel MRF buildings with compressed elastomer dampers. A simplified design procedure was used to design seven different systems of steel MRFs combined with compressed elastomer dampers in which the properties of the MRFs and dampers were varied. The combined systems are designed to achieve performance, which is similar to or better than the performance of conventional steel MRFs designed according to current seismic codes. Based on the results of nonlinear seismic response analyses, under both the design basis earthquake and the maximum considered earthquake, target properties for a new generation of compressed elastomer dampers are defined. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
The seismic response of single‐degree‐of‐freedom (SDOF) systems incorporating flag‐shaped hysteretic structural behaviour, with self‐centring capability, is investigated numerically. For a SDOF system with a given initial period and strength level, the flag‐shaped hysteretic behaviour is fully defined by a post‐yielding stiffness parameter and an energy‐dissipation parameter. A comprehensive parametric study was conducted to determine the influence of these parameters on SDOF structural response, in terms of displacement ductility, absolute acceleration and absorbed energy. This parametric study was conducted using an ensemble of 20 historical earthquake records corresponding to ordinary ground motions having a probability of exceedence of 10% in 50 years, in California. The responses of the flag‐shaped hysteretic SDOF systems are compared against the responses of similar bilinear elasto‐plastic hysteretic SDOF systems. In this study the elasto‐plastic hysteretic SDOF systems are assigned parameters representative of steel moment resisting frames (MRFs) with post‐Northridge welded beam‐to‐column connections. In turn, the flag‐shaped hysteretic SDOF systems are representative of steel MRFs with newly proposed post‐tensioned energy‐dissipating connections. Building structures with initial periods ranging from 0.1 to 2.0s and having various strength levels are considered. It is shown that a flag‐shaped hysteretic SDOF system of equal or lesser strength can always be found to match or better the response of an elasto‐plastic hysteretic SDOF system in terms of displacement ductility and without incurring any residual drift from the seismic event. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

7.
This paper demonstrates the applicability of response history analysis based on rigid‐plastic models for the seismic assessment and design of steel buildings. The rigid‐plastic force–deformation relationship as applied in steel moment‐resisting frames (MRF) is re‐examined and new rigid‐plastic models are developed for concentrically‐braced frames and dual structural systems consisting of MRF coupled with braced systems. This paper demonstrates that such rigid‐plastic models are able to predict global seismic demands with reasonable accuracy. It is also shown that, the direct relationship that exists between peak displacement and the plastic capacity of rigid‐plastic oscillators can be used to define the level of seismic demand for a given performance target. Copyright© 2009 John Wiley & Sons, Ltd.  相似文献   

8.
The steel reinforced concrete (SRC) wall consists of structural steel embedded at the boundary elements of a reinforced concrete (RC) wall. The use of SRC walls has gained popularity in the construction of high‐rise buildings because of their superior performance over conventional RC walls. This paper presents a series of quasi‐static tests used to examine the behavior of SRC walls subjected to high axial force and lateral cyclic loading. The SRC wall specimens showed increased flexural strength and deformation capacity relative to their RC wall counterpart. The flexural strength of SRC walls was found to increase with increasing area ratio of embedded structural steel, while the section type of embedded steel did not affect the wall's strength. The SRC walls under high axial force ratio had an ultimate lateral drift ratio of approximately 1.4%. In addition, a multi‐layer shell element model was developed for the SRC walls and was implemented in the OpenSees program. The numerical model was validated through comparison with the test data. The model was able to predict the lateral stiffness, strength and deformation capacities of SRC walls with a reasonable level of accuracy. Finally, a number of issues for the design of SRC walls are discussed, along with a collection and analysis of the test data, including (1) evaluation of flexural strength, (2) calculation of effective flexural stiffness, and (3) inelastic deformation capacity of SRC walls. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
For the purpose of estimating the earthquake response, particularly the story drift demand, of reinforced concrete (R/C) buildings with proportional hysteretic dampers, an equivalent single‐degree‐of‐freedom (SDOF) system model is proposed. Especially in the inelastic range, the hysteretic behavior of an R/C main frame strongly differs from that of hysteretic dampers due to strength and stiffness degradation in R/C members. Thus, the proposed model, unlike commonly used single‐spring SDOF system models, differentiates the restoring force characteristics of R/C main frame and hysteretic dampers to explicitly take into account the hysteretic behavior of dampers. To confirm the validity of the proposed model, earthquake responses of a series of frame models and their corresponding equivalent SDOF system models were compared. 5‐ and 10‐story frame models were studied as representative of low‐ and mid‐rise building structures, and different mechanical properties of dampers—yield strength and yield deformation—were included to observe their influence on the effectiveness of the proposed model. The results of the analyses demonstrated a good correspondence between estimated story drift demands using the proposed SDOF system model and those of frame models. Moreover, the proposed model: (i) led to better estimates than those given by a single‐spring SDOF system model, (ii) was capable of estimating the input energy demand and (iii) was capable of estimating the total hysteretic energy and the participation of dampers into the total hysteretic energy dissipation, in most cases. Results, therefore, suggest that the proposed model can be useful in structural design practice. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
The effectiveness of hysteretic passive devices to protect and mitigate the response of a structure under seismic loading is well established by both analytical and experimental research. Nevertheless, a systematic and well‐established methodology for the topological distribution and size of these devices in order to achieve a desired structural response performance does not exist. In this paper, a computational framework is proposed for the optimal distribution and design of yielding metallic buckling restrained braces (BRB) and/or friction dampers within steel moment‐resisting frames (MRF) for a given seismic environment. A Genetic Algorithm (GA) is used to solve the resulting discrete optimization problem. Specific examples involving two three‐story, four‐bay steel MRFs and a six‐story, three‐bay steel MRF retrofitted with yielding and/or friction braces are considered. The seismic environment consists of four synthetic ground motions representative of the west coast of the United States with 5% probability of exceedance in 50 years. Non‐linear time‐history analyses are employed to evaluate the potential designs. As a result of the evolutionary process, the optimal placement, strength and size of the dampers are obtained throughout the height of the steel MRF. Furthermore, the developed computational approach for seismic design based upon GAs provides an attractive procedure for design of MRFs with hysteretic passive dampers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
The effectiveness of tuned mass dampers (TMD) in vibration control of buildings was investigated under moderate ground shaking caused by long‐distance earthquakes with frequency contents resembling the 1985 Mexico City (SCT) or the 1995 Bangkok ground motion. The elastic–perfectly plastic material behaviour was assumed for the main structure, with linear TMDs employed by virtue of their simplicity and robustness. The accumulated hysteretic energy dissipation affected by TMD was examined, and the ratio of the hysteretic energy absorption in the structure with TMD to that without it is proposed to be used, in conjunction with the peak displacement ratio, as a supplementary TMD performance index since it gives an indication of the accumulated damage induced in the inelastic structures. For the ground motions considered, TMD would be effective in reducing the hysteretic energy absorption demand in the critical storeys for buildings in the 1.8–2.8 s range. The consequence is reduction in damage of the buildings which would otherwise suffer heavy damage in the absence of TMD, resulting in economical restorability in the damage control limit state. This is of practical significance in view of the current trend toward performance‐based design. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

12.
Buildings are continually subject to dynamic loads, such as wind load, seismic ground motion, and even the load from internal utility machines. The recent trend of constructing more flexible high‐rise buildings underscores the importance of including viscoelastic dampers in building designs. Viscoelastic dampers are used to control the dynamic response of a building. If the seismic design is based only on the linear response spectrum, considerable error may occur when calculating the seismic response of a building; rubber viscoelastic dampers show non‐linear hysteretic damping that is quite different from viscous damping. This study generated a non‐linear response spectrum using a non‐linear oscillator model to simulate a building with viscoelastic dampers installed. The parameters used in the non‐linear damper model were obtained experimentally from dynamic loading tests. The results show that viscoelastic dampers effectively reduce the seismic displacement response of a structure, but transmit more seismic force to the structure, which essentially increases its seismic acceleration response. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

13.
Hysteresis steel dampers are widely used in earthquake-resistant structures, where some of them are anisotropic and capable of sustaining earthquake-induced bidirectional deformation. In this paper, a simplified analytical model is proposed for simulating the hysteretic behavior of U-shaped steel dampers with horizontal bidirectional deformation. The proposed model is composed of a series of shear springs with different nonlinear characteristics in a radial configuration, and the Menegotto–Pinto hysteresis model is employed to represent the hysteretic characteristics of the springs. The mechanical and shape-related parameters of the hysteresis model are set according to the multi-directional deformation characteristics of steel dampers. With the aim of validating the effectiveness and applicability of the analytical model, a U-shaped steel damper was used as an example. The pseudo-static hysteretic characteristics of the steel damping element were analyzed and the elasto-plastic seismic response of a curved bridge featuring a steel hysteresis device was investigated. The results showed that the proposed model is sufficiently accurate to simulate the hysteretic behavior of U-shaped steel dampers, and thus provides a practical method to assess U-shaped steel dampers through seismic response analysis.  相似文献   

14.
This paper presents a detailed study on feasibility of un‐bonded fiber reinforced elastomeric isolator (U‐FREI) as an alternative to steel reinforced elastomeric isolator (SREI) for seismic isolation of un‐reinforced masonry buildings. Un‐reinforced masonry buildings are inherently vulnerable under seismic excitation, and U‐FREIs are used for seismic isolation of such buildings in the present study. Shake table testing of a base isolated two storey un‐reinforced masonry building model subjected to four prescribed input excitations is carried out to ascertain its effectiveness in controlling seismic response. To compare the performance of U‐FREI, same building is placed directly on the shake table without isolator, and fixed base (FB) condition is simulated by restraining the base of the building with the shake table. Dynamic response characteristic of base isolated (BI) masonry building subjected to different intensities of input earthquakes is compared with the response of the same building without base isolation system. Acceleration response amplification and peak response values of test model with and without base isolation system are compared for different intensities of table acceleration. Distribution of shear forces and moment along the height of the structure and response time histories indicates significant reduction of dynamic responses of the structure with U‐FREI system. This study clearly demonstrates the improved seismic performance of un‐reinforced masonry building model supported on U‐FREIs under the action of considered ground motions. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
Seismic design codes enforce a set of capacity design rules for steel moment-resisting frames (MRFs) to promote a ductile sway plastic mechanism that involves plastic hinges in beams and column bases. Previous research showed that these capacity design rules may not be effective for tall steel MRFs with viscous dampers under strong earthquakes due to high axial forces in columns. To address this issue, steel MRFs with linear viscous dampers of different stories are designed according to Eurocode 8 along with using a slightly modified conservative capacity design rule. According to this rule, the axial force for the capacity design of a column in the force path of viscous dampers is calculated as the envelope of the axial force from the peak drift state, and, the axial force from the peak velocity state times a scale factor. This envelope axial force value along with the bending moment and shear force from the peak drift state are used to carry out the capacity design of the column by using the formulae of Eurocode 8, i.e. in the same way with a column of a steel MRF without dampers. Incremental dynamic analyses for 44 earthquake ground motions show that the modified conservative capacity design rule results in steel MRFs with viscous dampers that have plastic mechanisms similar to those of steel MRFs without dampers. Moreover, the proposed capacity design rule becomes stricter for buildings with more than 10 stories to address that available analysis methods for structures with dampers underestimate the peak damper forces in the lower stories of yielding tall steel MRFs. More work is needed to extend the findings of this work to the case of steel MRFs with nonlinear viscous dampers.  相似文献   

16.
A simplified seismic design procedure for steel portal frame piers installed with hysteretic dampers is proposed, which falls into the scope of performance‐based design philosophy. The fundamental goal of this approach is to design a suite of hysteretic damping devices for existing and new bridge piers, which will assure a pre‐defined target performance against future severe earthquakes. The proposed procedure is applicable to multi‐degree‐of‐freedom systems, utilizing an equivalent single‐degree‐of‐freedom methodology with nonlinear response spectra (referred to as strength‐demanded spectra) and a set of formulae of close‐form expressions for the distribution of strength and stiffness produced in the structure by the designed hysteretic damping devices. As an illustrative example, the proposed procedure is applied to a design of a simple steel bridge pier of portal frame type with buckling‐restrained braces (one of several types of hysteretic dampers). For the steel portal frame piers, an attempt is made to utilize not only the displacement‐based index but also the strain‐based index as pre‐determined target performance at the beginning of design. To validate this procedure, dynamic inelastic time‐history analyses are performed using the general‐purpose finite element program ABAQUS. The results confirm that the proposed simplified design procedure attains the expected performance level as specified by both displacement‐based and strain‐based indices with sufficient accuracy. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

17.
A ductile Vierendeel frame can be constructed by incorporating steel panel dampers (SPDs) into a moment‐resisting frame (MRF). Thus, the stiffness, strength, and ductility of the lateral force–resisting system can be enhanced. The proposed 3‐segment SPD possesses a center inelastic core (IC) and top and bottom elastic joints. This paper discusses the mechanical properties, capacity design method, and buckling‐delaying stiffeners for the SPDs through the use of cyclic loading tests on 2 specimens. Tests confirm that SPDs' cyclic force vs deformation relationships can be accurately predicted using either the Abaqus or PISA3D model analyses. The paper also presents the capacity design method for boundary beams connected to the SPDs of a typical SPD‐MRF. The seismic performance of an example 6‐story SPD‐MRF is evaluated using nonlinear response history analysis procedures and 240 ground accelerations at 3 hazard levels. Results indicate that under 80 maximum considered earthquake ground accelerations, the mean‐plus‐one standard deviation of the shear deformation of the ICs in the SPDs is 0.055 rad, substantially less than the 0.11 rad deformational capacity observed from the SPD specimens. The experimental cumulative plastic deformation of the proposed SPD is 242 times the yield deformation and is capable of sustaining a maximum considered earthquake at least 8 times before failure. This paper introduces the method of using one equivalent beam‐column element for effective modeling of the 3‐segment SPD. The effects of the IC's relative height and stiffness on the overall SPD's elastic and postelastic stiffness, elastic deformation limits, and inelastic deformational demands are discussed.  相似文献   

18.
19.
This paper investigates the effect of the composite action on the seismic performance of steel special moment frames (SMFs) through collapse. A rational approach is first proposed to model the hysteretic behavior of fully restrained composite beam‐to‐column connections, with reduced beam sections. Using the proposed modeling recommendations, a system‐level analytical study is performed on archetype steel buildings that utilize perimeter steel SMFs, with different heights, designed in the West‐Coast of the USA. It is shown that in average, the composite action may enhance the seismic performance of steel SMFs. However, bottom story collapse mechanisms may be triggered leading to rapid deterioration of the global strength of steel SMFs. Because of composite action, excessive panel zone shear distortion is also observed in interior joints of steel SMFs designed with strong‐column/weak‐beam ratios larger than 1.0. It is demonstrated that when steel SMFs are designed with strong‐column/weak‐beam ratios larger than 1.5, (i) bottom story collapse mechanisms are typically avoided; (ii) a tolerable probability of collapse is achieved in a return period of 50 years; and (iii) controlled panel zone yielding is achieved while reducing the required number of welded doubler plates in interior beam‐to‐column joints. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

20.
Robust performance of hysteretic dampers, used in controlling mid‐rise buildings, against change of earthquake characteristics is investigated in this paper. A shear type ten‐storey building incorporating hysteretic dampers is studied as a model under the assumption of elastic perfectly plastic behavior for inelastic frame and damper deformations. An energy‐based damper performance index is used to evaluate damper overall efficiency. Thirty‐five earthquake records are applied and the damper strength is optimized for each earthquake record to obtain the maximum performance index or the damper efficiency. Based on the obtained numerical results it is found that, besides the effect of maximum energy input on damper efficiency, other time‐dependant properties such as energy‐based effective duration and earthquake dominant period have great influence on the damper efficiency. A factor (α), which represents the combined effect of maximum energy input, effective duration and dominant earthquake period, is also derived for the prediction of damper efficiency. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   