首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
综合地球物理技术在采空区的探测中发挥了重要作用.目前通常采用单方法反演、仅对不同方法反演结果进行对比解释的综合勘探方式,单方法反演的多解性严重降低了其探测精度.如何提高采空区的探测精度,对采空区进行有效探测一直被认为是地球物理技术面临的首要难题.为了提高地震与电法技术的探测精度,基于交叉梯度联合反演理论,设计了地震初至折射走时数据和高密度电法数据的联合反演算法流程,对采空区理论模型和野外实际数据进行了联合反演处理.结果发现通过两者的联合反演,不仅可以提高采空区电阻率反演模型的成像效果,而且能够获得地震单方法反演难以成像的采空区低速异常体,从而提高了地震与电法技术对采空区的探测精度.表明地震与电法探测数据联合反演是一种提高采空区探测精度的有效方法.  相似文献   

2.
An integrated geophysical survey has been conducted at the Tarragona’s Cathedral (Catalonia, NE Spain) with the aim to confirm the potential occurrence of archaeological remains of the Roman Temple dedicated to the Emperor Augustus. Many hypotheses have been proposed about its possible location, the last ones regarding the inner part of the Cathedral, which is one of the most renowned temples of Spain (twelfth century) evolving from Romanesque to Gothic styles. A geophysical project including electrical resistivity tomography (ERT) and ground probing radar (GPR) was planned over 1 year considering the administrative and logistic difficulties of such a project inside a cathedral of religious veneration. Finally, both ERT and GPR have been conducted during a week of intensive overnight surveys that provided detailed information on subsurface existing structures. The ERT method has been applied using different techniques and arrays, ranging from standard Wenner–Schlumberger 2D sections to full 3D electrical imaging with the advanced Maximum Yield Grid array. Electrical resistivity data were recorded extensively, making available many thousands of apparent resistivity data to obtain a complete 3D image after a full inversion. In conclusion, some significant buried structures have been revealed providing conclusive information for archaeologists. GPR results provided additional information about shallowest structures. The geophysical results were clear enough to persuade religious authorities and archaeologists to conduct selected excavations in the most promising areas that confirmed the interpretation of geophysical data. In conclusion, the significant buried structures revealed by geophysical methods under the cathedral were confirmed by archaeological digging as the basement of the impressive Roman Temple that headed the Provincial Forum of Tarraco, seat of the Concilium of Hispania Citerior Province.  相似文献   

3.
In northern Chile, which is part of the Atacama Desert, groundwater supply and storage are controlled by deep structural phenomena. Several geophysical exploration techniques were used to determine the structure and depth of the basement of a broad valley filled with unconsolidated alluvial deposits. The gravity method was applied to obtain a general picture of the basement. This was followed by seismic refraction measurements along two traverse lines which appeared to be of major interest. Additional experiments with the magnetic and the telluric methods supplemented the geophysical investigations. In this paper the results of the different geophysical methods are presented, compared, and evaluated with respect to the usefulness in arid regions. It is concluded that a complementary use of the gravity method and the seismic refraction method is a very fruitful and efficient approach for the geophysical reconnaissance of water-bearing basins in flat and arid zones like the Atacama Desert.  相似文献   

4.
Archaeoseismology can provide a useful chronological tool for constraining earthquakes and documenting significant evidence that would otherwise be lost. In this paper, we report a case of surface faulting on ancient man-made structures belonging to the archaeological site of Santa Venera al Pozzo situated along the eastern flank of Mt. Etna volcano in eastern Sicily (southern Italy), which is affected by well-developed tectonic faults. Geological surveys highlight a set of fractures affecting the archaeological ruins, suggesting the occurrence of a capable fault zone across the area. An integrated geophysical survey was carried out in order to identify the main subsurface tectonic discontinuity ascribable to the fault zone. The information derived from different geophysical techniques, such as electrical resistivity tomography, seismic refraction tomography, ground-penetrating radar, and magnetic surveys allowed us to infer that the fractures observed at the surface could have been produced by coseismic rupture. They are conceivably linked to a strong earthquake that probably occurred in the Roman period, around mid-end of the third-century AD; time constraints are inferred through the dating of buildings of the archaeological site.  相似文献   

5.
6.
Near‐surface cavities can pose serious hazards to human safety, especially in highly urbanized town centres. The location of subsurface voids, the estimation of their size and the evaluation of the overburden thickness are necessary to assess the risk of collapse. In this study, electrical resistivity tomography (ERT) and seismic refraction tomography data are integrated in a joint interpretation process for cavity location in the city of Rome. ERT is a well established and widely employed method for cavity detection. However, additional information provided by seismic refraction tomography is capable of eliminating some potential pitfalls in resistivity data interpretation. We propose that the structure of the cavities defined by ERT can be used as a base to optimize seismic refraction tomography investigations within the framework of a joint interpretation process. Data integration and the insertion of a priori information are key issues for reducing the uncertainties associated with the inversion process and for optimizing both acquisition procedures and computation time. Herein, the two geophysical methods are tested on both synthetic and real data and the integration of the results is found to be successful in detecting isolated cavities and in assessing their geometrical characteristics. The cavity location inferred by geophysical non‐invasive methods has been subsequently confirmed by direct inspection.  相似文献   

7.
Geophysical methods were applied for hydrogeological targets in many countries including Vietnam. This paper presents results of using complex geophysical techniques as well as 2D electrical resistivity imaging (ERI), vertical electrical sounding (VES), very low frequency (VLF), and seismic refraction for geological structure investigation for locating the aquifers and assessing the hydrogeological conditions for groundwater potential in industrial zones of North Hanoi, Vietnam. The locations of two aquifers are determined by their depth and thickness on the basis of resistivity and seismic velocity values which were proved by stratifications of three boreholes to 40–60 m of depth on the study area. There are connections from surface water to shallow aquifer by hydraulic windows, as follows from VLF data. The deeper aquifer can be considered as a potential groundwater supply, but the water level is descending in time, as shown by hydrological monitoring. However, with careful use and by reducing sources of pollution, groundwater can continue to be an important natural resource for future.  相似文献   

8.
The Santa Maria di Collemaggio Basilica is an important cultural heritage site and exemplifies Romanesque-Gothic art in the Abruzzo region (central Italy). Erected in the second half of the XII century, the Basilica was severely damaged during the April 6, 2009 L’Aquila earthquake (MW 6.1). In particular, the area of the transept collapsed causing the dome to fall. A refined two-dimensional (2D) geotechnical model was built representing a section that includes the Basilica, in order to better understand the soil response of the Basilica site. The subsoil model was constrained using the geophysical and geotechnical data collected from the seismic microzonation studies, the reconstruction of private damaged buildings and other technical and scientific studies realized in the L’Aquila basin and in the area of the Basilica before and after L’Aquila earthquake. 2D site response analyses were performed to verify the presence of local site effects by comparing simulated versus experimental transfer functions. Moreover, a frequency–wavenumber (f–k) analysis was executed with the aim of evaluating the occurrence of surface waves generated within the basin. 2D seismic effects involve significant amplification in the period range of engineering interest, therein providing an appropriate elastic response spectrum for the restoration of the Basilica.  相似文献   

9.
The Peinan archaeological site is the most intact Neolithic village with slate coffin burial complexes in Taiwan. However, the area that potentially contains significant ancient remains is covered by dense vegetation. No reliable data show the distribution of the ancient village, and no geophysical investigation has been performed at this site. To evaluate various geophysical methods under the geological setting and surface condition of the site, the physical properties of the remains were measured and four geophysical methods involving magnetic, electromagnetic (EM), electrical resistivity tomography (ERT), and ground-penetrating radar (GPR) were tested along three parallel profiles. The results imply that the EM and magnetic methods are much cost-effective and suitable for investigating the entire area. GPR and ERT methods can provide high resolution subsurface image, which are much suitable for subsequently detail investigation.The EM and magnetic surveys were thus conducted over the entire Peinan Cultural Park to understand the distribution of the ancient building remains at the Peinan site. The results of this study were verified by subsequent excavations, which indicate that the EM survey was successful in delineating the majority of the ancient village because the basements of building are highly resistive in comparison to the background sediment. The results of this investigation suggest that the ancient village was broadly distributed over the eastern part of the Peinan Culture Park and extended to the southeast.  相似文献   

10.
11.
In the area near the village of Jazak (southern part of Fruška Gora mountain, Serbia), hydrogeological investigations were carried out for the purpose of finding a water supply source to provide an adequate volume of water for a mineral water bottling plant. The first exploratory borehole (IBJf-1) penetrated a water-bearing layer of Miocene organogenic limestones. This aquifer has a thickness of about 30 m and a yield of only 2.2 l/s, which falls short of the required water volume (5 l/s).The objective of further exploration was to define the attitude and extension of the aquifer and thus select a more favourable site for a new exploratory borehole that would secure the required volume of water. For this purpose, geophysical exploration was carried out in 2003 through vertical electrical sounding (VES) and high-resolution 3D reflection seismic methods. The VES measurements enabled determination of aquifer depth and indicated that the water-bearing strata extend over the entire area studied. However, because of the equivalence problem, it was not possible to determine the thickness of the water-bearing stratum based solely on the VES data. Thus, the 3D seismic method was used in the second stage of investigation. A low-cost 3D seismic survey was carried out with fixed receiver lines, using a vibrator as the source of the seismic waves.From the 3D seismic data it was possible to determine the aquifer thickness. The depth of the aquifer determined by interpretation of the 3D seismic data was in accordance with the depth determined by the VES method. Based on the assumption that the hydraulic conductivity of this formation is identical or similar over the entire area, as well as the fact that the first well showed the presence of a subartesian aquifer, we proposed drilling another borehole (IBJf-2) in the zone where the data indicated that the water-bearing stratum was much thicker. The data obtained by drilling and coring were in agreement with the predicted aquifer thickness. Pumping tests showed that the water discharge in borehole IBJf-2 was 6 l/s.The results show that the objective of delineating the groundwater body by combined application of two geophysical methods (VES and 3D seismic) was successfully performed.  相似文献   

12.
Muro Leccese (Lecce) contains one the most important Messapian archaeological sites in southern Italy.The archaeological interest of the site arises from the discovery of the remains of Messapian walls, tombs, roads, etc. (4th–2nd centuries BC) in the neighbourhood. The archaeological remains were found at about 0.3 m depth.At present the site belongs to the municipality, which intends to build a new sewer network through it. The risk of destroying potentially interesting ancient archaeological structures during the works prompted an archaeological survey of the area. The relatively large dimensions of the area (almost 10,000 m2), together with time and cost constraints, made it necessary to use geophysical investigations as a faster means to ascertain the presence of archaeological items. Since the most important targets were expected to be located at a soil depth of about 0.3 m, a ground-penetrating radar (GPR) survey was carried out in an area located near the archaeological excavations. Unfortunately the geological complexity did not allow an easy interpretation of the GPR data.Therefore a 3D electrical resistivity tomography (ERT) scan was conducted in order to resolve these interpretation problems.A three-way comparison of the results of the dense ERT measurements parallel to the x axis, the results of the measurements parallel to the y axis and the combined results was performed.Subsequently the synthetic model approach was used to provide a better characterization of the resistivity anomalies visible on the ERT field data.The 3D inversion results clearly illustrate the capability to resolve in view of quality 3D structures of archaeological interest. According to the presented data the inversion models along one direction (x or y) seems to be adequate in reconstructing the subsurface structures.Naturally field data produce good quality reconstructions of the archaeological features only if the x-line and y-line measurements are considered together. Despite the increased computational time required by the 3D acquisition and 3D inversion schemes, good quality results can be produced.  相似文献   

13.
Near-surface seismic refraction and surface wave data were collected at a site to determine the feasibility and limitations of using these seismic methods to detect and localize a shallow tunnel in unconsolidated sediments. Data sets were collected both before and after the construction of the tunnel. We were able to detect the air-filled cavity using multichannel analysis of surface waves. The refraction tomography results showed the tunnel location in the raypath coverage plots, but only small velocity variations were observed. In tandem the two methods would reduce false positives, but individually the false alarm rate would likely be high due to non-uniqueness of the results. In this geologic setting, these methods are not the best choice of geophysical methods to detect clandestine tunnels and should be combined with other geophysical techniques to improve and constrain interpretations.  相似文献   

14.
The integrated use of electrical resistivity tomography (ERT) and ground penetrating radar (GPR) measurements, and in particular the joint analysis of 2D and 3D data, can represent a valid solution for target identification at complex archaeological sites. A good example, in this respect, is given by the case study of a Phoenician–Punic necropolis in the archaeological site of Nora, in southern Sardinia (Italy), where GPR and ERT measurements were collected before site excavation. In this specific case, the mix of soil and air in the buried chambers, as well as the orientation and the complex spatial distribution of these structures into the sandstone bedrock, generated a number of anomalies difficult to interpret only using 2D results. Only the integration of all GPR and ERT data in a 3D view, and the comparison with archaeological evidence after the excavation, allowed a solid interpretation of geophysical anomalies visible in the 2D sections. Overall, this case study demonstrates the efficiency of the combined use of GPR and ERT acquisitions and shows how, in general, only the joint analysis of 2D data and in a 3D view can help the interpretation of the real distribution of the buried archaeological remains at similar archaeological complex sites.  相似文献   

15.
The integration of geological, geophysical, and geotechnical interpretation at the southern part of 15th of May City, have been used to evaluate the subsurface stratigraphy, especially the clay layer which may cause serious danger to construction. Those techniques have been used to delineate the subsurface structures as normal faults, which play a critical role on the stability of buildings. Geological setting of the area has been evaluated through the construction of a geological map from different geological sections and samples obtained from more than 30 observation points. Geophysical tools such as vertical electrical soundings (12 VESs), 2-D dipole–dipole array (7 sections), P-wave shallow seismic refraction (31 profiles) and multiple channel analysis of surface waves (31 MASW profiles) have been carried out to image the subsurface situation. Geotechnical evaluation using 26 boreholes, samples, laboratory tests and geotechnical parameters has been done at the area of interest. The geological setting demonstrates that the city had been constructed on the second and third members of Qurn Formation (Upper Eocene) composed of argillaceous limestone, marl and shale. Two normal faults are passing through the area were observed. The resistivity (VES and dipole–dipole) and seismic (P-waves and MASW) results reflect the presence of the two normal faults cross the study area, affecting the obtained section of marl, clayey marl and limestone layers. The geotechnical information indicate the presence of the normal faults and the existence of clay layer with swelling ability reaching 140%, which may cause cracks in the upper layers and/or subsidence.  相似文献   

16.
The Roman fort from Sfârleanca is one of the most representative archaeological sites dating from the Roman period (2nd century A.D.) in Northern Muntenia. The existing natural and anthropic features of the environment required the application of geophysical methods in order to outline the spatial pattern of the buried remains, to define the geometry of the anthropogenic settlements and to obtain detailed information about different archaeological materials without digging. During the survey, two different geophysical methods have been employed: total magnetic field measurements and electrical resistance mapping using Twin-probe array. The instrument consists of GSM19W Overhauser magnetometers with GPS, in base-rover system, and a twin-probe array LGM 4-Point light hp. The measurements were used to draw primary maps of the physical parameters (total magnetic field strength/intensity, electrical resistance), and also processed maps (filtering, derivative). The magnetic results obtained by interpreting the anomalies yielded information about the limits of the fort, about the internal organization of the military structure (its axial road, partially its secondary road, the localization and the shape of its constructions) and at the bath and heating installation. A previously unknown element is the possible water supply pipe made of ceramic material highlighted by the mathematical modelling of the data obtained by the magnetic investigations. Electrical resistance results provide complementary information to the magnetic survey concerning the limits of the baths and the remains of the fort structure. This paper brings to light geophysical investigations into this Roman fort and baths, extending the picture produced by previous archaeological excavations that only dealt with a small part of the site. It indicates the importance of using geophysical methods in preliminary archaeological research and the advantages of combining total magnetic field measurements and electrical resistance mapping when investigating an archaeological site characterized by a number of environmental difficulties.  相似文献   

17.
The area located inside the São Sebastião volcanic crater, at the southeast end of Terceira Island (Azores), is characterized by an important amplification of ground motion with respect to the surrounding area, as clearly demonstrated by the spatial distribution of the damage that occurred during the Terceira earthquake (the strongest earthquake felt in the Island during the recent decades — 01/01/1980 — M = 7.2). Geological and geophysical studies have been conducted, to characterize the volcanic crater and understand the different site effects that occurred in the village of São Sebastião. The complexity of the subsurface geology, with intercalations of compact basalt and soft pyroclastic deposits, is associated to extreme vertical and lateral velocity contrasts, and poses a serious challenge to different geophysical characterization methods. The available qualitative model did not allow a complete understanding of the site effects. A new seismic campaign has been designed and acquired, and a single, geologically consistent geophysical model has been generated integrating the existing and new data. The new campaign included two cross-line P-wave seismic refraction profiles, four short SH-wave seismic reflection profiles, and seven multichannel surface wave acquisitions. The integration and joint interpretation of geophysical and geological data allowed mutual validation and confirmation of data processing steps. In particular, the use of refraction, reflection and surface wave techniques allowed facing the complexity of a geology that can pose different challenges to all the methods when used individually: velocity inversions, limited reflectivity, and lateral variations. It is shown how the integration of seismic data from different methods, in the framework of a geological model, allowed the geometrical and dynamic characterization of the site. Correlation with further borehole information, then allowed the definition of a subsoil model for the crater, providing information that allowed a better understanding of the earthquake site effects in the São Sebastião village. The new near-surface geological model includes a lava layer within the soft infill materials of the crater. This new model matches closely with the damage distribution map, and explains the spatial variation of building stock performance in the 1980 earthquake.  相似文献   

18.
Hidden mineshafts located in urban areas are a significant problem across much of the industrialized world. Electrical resistivity tomography (ERT) is a technique that can detect and characterize hidden mine entries by exploiting resistivity contrasts between the shaft and surrounding materials, resulting from either compositional or structural differences. A case study is presented in which both surface and crosshole 3D ERT surveys are used to image a hidden backfilled mineshaft at a built environment site, situated on Carboniferous Lower Coal Measures strata in the UK.Backfilled shafts generally present the greatest challenge for detection using geophysical methods, as contrasts between the fill and bedrock are typically low compared to air or water-filled conditions. Nevertheless, the shaft in this case was identified by both the surface and crosshole 3D surveys. The shaft appeared as a strongly resistive anomaly relative to background materials, which we interpreted as resulting from the disturbed fabric of the fill materials rather than any significant compositional differences. The study highlighted the respective strengths and weaknesses of the surface and crosshole ERT methodologies for this type of problem. The surface survey, which covered a non-rectangular area to accommodate irregular boundaries and other physical obstructions, provided a relatively rapid means of investigating the study site. However, this method had a limited depth of investigation and was constrained in its coverage by the locations of buildings. By contrast, the 3D crosshole method was able to image the shaft to the level of the deepest borehole electrodes. Although crosshole ERT is too expensive to be used for large-scale mineshaft surveys, this study clearly demonstrates its suitability for targeted investigations where surface methods cannot be deployed, such as scanning beneath surface structures or in situations where it is essential for resolution to be maintained with depth.  相似文献   

19.
A high resolution geophysical survey was carried out on the Pont De Coq, a medieval stone arch bridge located in Normandy (France) in 2011 and 2012. Two complementary methods are used: Electrical Resistivity Tomography (ERT) and Ground PenetratingRadar (GPR). They allow to evaluate the structural state of the bridge and to characterize the subsurface around and beneath the bridge. An excellent correlation is obtained between the geophysical methods and the geological data obtained around the bridge. In order to improve the restitution of the geophysical data, an advanced photogrammetric method is performed, providing a high resolution 3D Digital Terrain Model (DTM) of the Pont de Coq. The advanced photogrammetry enhances the presentation of the GPR and ERT data. This approach is an easy-to-use, rapid and cost-effective tool for stakeholders. Finally, it is a promising and original method for improved interpretations of future geophysical surveys.  相似文献   

20.
Vicoforte is a small town in Northern Italy, which hosts a Cathedral with the world's largest elliptical dome. The name of the Basilica is “Regina Montis Regalis” and it is of extraordinary architectural and structural importance. The main objective of this study is the definition of the seismic hazard at the site of Vicoforte following a deterministic approach. Although Vicoforte is located in an area of moderate seismicity, the calculation of the most unfavourable seismic ground shaking scenarios is of great interest due to the importance of the Basilica and its vulnerability to even a moderate seismic excitation.The closest active faults to Vicoforte were identified in order to simulate the potentially most severe ground shaking scenarios compatibly with the tectonic and seismic setting of the region. Subsequently, numerical simulations were conducted through finite faults numerical models using two different approaches: the extended kinematic source model of Hisada and Bielak [24] and the stochastic method of Motazedian and Atkinson [38]. They, respectively, simulate the low and high frequency ranges of predicted ground motion. The numerical models used for the simulations were calibrated by a comparison between synthetic results and recorded data. A parametric study was finally carried out to identify the most critical fault rupture mechanisms.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号