首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Water resources in the Algerian South are rare and difficult to reach because they are often too deep. This is the case of Guerrara which is characterized by an annual precipitation average of less than 60 mm. The water supply is warranted from groundwater, frequently too deep and badly known. The main purpose of the present study is to determine the geometry of aquifer from geophysical data. Fourteen vertical electrical soundings covering the total surface area were carried out by using an arrangement of electrodes called “Schlumberger array.” The length of the selected transmission line (AB) was 1,000 m, which allowed a vertical investigation reaching up to 160 m of depth. The analysis of the results shows that the prospected zone is characterized by the succession of layers with different electrical resistivities. A sandstone aquifer characterized by resistivities near 100 Ω m overcoming a limestone aquifer stronger with values that exceed 1,000 Ω m, separated by a conductive layer of clay with average resistivity of 15 Ω m. Distribution map of sandstones thickness shows the structural variations of this horizon allowing an estimation of its hydraulic potential.  相似文献   

2.
The western sector of the Tagliamento River basin (Friuli Venezia-Giulia Region; northern Italy) is characterized by important water resources, both superficial and underground. In particular, in the Quaternary deposits of the plain, up to a depth of 500 m, six artesian aquifer systems exist. A large amount of lithological, geomorphological, and hydrogeological data is presented, allowing for definition of (a) the principal aquifer system of the area to a depth of about 500 m; (b) geometrical characteristics of the aquifers (thickness, lateral extension, etc); (c) the hydraulic parameters (hydraulic conductivity, transmissivity); (d) chemico-physical characteristics of the water; and (e) vulnerability to pollution of the aquifer systems. In a test area, where many boreholes were drilled for fresh water supply, the conceptual hydrogeological model was integrated by a detailed and repeated three-dimensional (3D) resistivity survey using combined electrical resistivity tomography (ERT) and time-domain electromagnetic (TDEM) soundings. ERT investigation was mainly used to get detailed information about geometry and porosity of the overburden and to calibrate the shallowest TDEM information.  相似文献   

3.
The current study is carried out for the determination of groundwater potential in District Rawalakot Azad Jammu and Kashmir (AJ&K) Pakistan by using electrical resistivity method and petrographic analysis of the area. The tape-compass-clinometers method was used in section measurement to understand the facies and depositional environment. The electrical resistivity survey was carried out in the project area in sub-Himalayan Siwaliks system of Pakistan to overcome water scarcity in a few regions. The area was chartered with the Schlumberger configuration up to the AB/2 depth of 150 m. The ABEM Terrameter SAS 4000 (Sweden) and accessories were used to acquire vertical electrical soundings in 24 locations. The results obtained through the 2D and 3D isoresistivity maps of apparent resistivity for 15, 45, and 130 m spacings, the 3D isoresistivity maps of transverse resistance and anisotropy, the VES curve types, and the measured stratigraphic section of surface rocks revealed the confined or semi-confined type aquifers within sedimentary formations. The petrographic analysis indicates the clues of the secondary porosity and fluid migrations through the rocks.  相似文献   

4.
Vertical electrical soundings technique was used to evaluate the aquifer characteristics and distribution in the northern part of Paiko in Nigeria. A total of thirty vertical electrical soundings were carried out using ABEM SAS4000 Terrameter, and the data was analyzed both manually and with software (Resist software). The result revealed the aquifer resistivity and thickness to vary from 10.9 to 80,368 Ωm, and 1.06 to 72 m, respectively. Also, hydraulic conductivity ranges from 0.010267 to 41.61928 m/day while transmissivity values range from 0.035215 to 70.09302 m2. The hydrogeological maps (hydraulic conductivity and transmissivity image maps) showed the variations of these parameters in the study area and that the southwestern part of the area has prolific aquifer.  相似文献   

5.
Detailed local geological, geophysical, and hydrogeological investigations were carried out for the alluvial aquifer in the Kangavar basin, West Iran to delineate the architecture of different subsurface geological horizons using lithologs and generated vertical electrical sounding (VES) data. An attempt has also been made to estimate aquifer transmissivity from resistivity data. Forty VESs were recorded with the Schlumberger electrode configuration in the study area; 28 of these were selected for evaluation. The maximum current electrode spacing was 400–500 m. The data obtained were interpreted by computer iterative modeling with curve matching for calibration purposes. In order to ascertain the subsurface geological framework, the general distribution of resistivity responses of the geological formations was obtained and geoelectrical sections along a number of lines were prepared. Probable aquifer horizons from these sections were identified. The transmissivity of the unconfined aquifer was computed by determining the Dar-Zarrouk parameters (longitudinal unit conductance and transverse unit resistance) and were compared with the actual field transmissivity. The results showed a direct relation between aquifer transmissivity and modified transverse resistance.  相似文献   

6.
A combination of vertical electrical soundings (VES), 2D electrical resistivity imaging (ERI) surveys and borehole logs were conducted at Magodo, Government Reserve Area (GRA) Phase 1, Isheri, Southwestern Nigeria, with the aim of delineating the different aquifers present and assessing the groundwater safety in the area. The Schlumberger electrode array was adopted for the VES and dipole-dipole array was used for the 2D imaging. The maximum current electrode spread (AB) was 800 m and the 2D traverse range between 280 and 350 m in the east-west direction. The thickness of impermeable layer overlying the confined aquifer was used for the vulnerability ratings of the study area. Five lithological units were delineated: the topsoil, clayey sand, unconsolidated sand which is the first aquifer, a clay stratum and the sand layer that constitutes the confined aquifer horizon. The topsoil thickness varies from 0.6 to 2.6 m, while its resistivity values vary between 55.4 and 510.6 Ω/m. The clayey sand layers have resistivity values ranging from 104.2 to 143.9 Ω/m with thickness varying between 0.6 and 14.7 m. The resistivity values of the upper sandy layer range from 120.7 to 2195.2 Ω/m and thickness varies from 3.3 to 94.0 m. The resistivity of the clay layer varies from 11.3 to 96.1 Ω/m and the thickness ranges from 29.6 to 76.1 m. The resistivity value of the confined aquifer ranges between 223 and 1197.4 Ω/m. The longitudinal conductance (0.0017–0.02 mhos) assessment of the topsoil shows that the topsoil within the study area has poor overburden protective capacity, and the compacted impermeable clay layer shows that the underlying confined aquifer is well protected from contamination and can be utilized as a source of portable groundwater in the study area. This study therefore enabled the delineation of shallow aquifers, the variation of their thicknesses and presented a basis for safety assessment of groundwater potential zones in the study area.  相似文献   

7.
The combination of layer resistivity and thickness in the so called Da-zarrouk parameters S (longitudinal conductance) and R (transverse resistance) have proved useful in the evaluation of the transmissivities of the aquifers around Owerri and environs. The area is underlain by the unconsolidated to semi-consolidated coastal Benin Formation. The surface direct current electrical resistivity method was used in the study. Seven Vertical Electrical Soundings (VES) data by the Schlumberger array was acquired in the area. A maximum current electrode spacing (AB) of 1000 m was used for data acquisition. Four of the soundings were carried out near existing boreholes. Computer modelled interpretative methods was utilized in processing the data. Results show that the depth to the water level is shallow around Ife and Egbu areas with a mean depth of 30 m. Semi-deep aquifers were encountered around Okpalla and AVU areas with a mean depth of 90 m while very deep aquifers were sensed around Owerri and Obinze areas with a mean depth of 125 m. Aquifer thicknesses in the study area range from 8 m at Ife and 117 m at Owerri. The diagnostic Kσ = constant value have proved so useful in calculating transmisivities and hydraulic conductivities of all the sounding locations including areas where no boreholes exist. Hydraulic conductivity varies between 6.19m/day at Ife and 24.7 m/day at Obinze. Transmissivity values also very between 51.39 m2/day at Ife and 1379.56 m2/day at Owerri. It is hoped that the results would help in long term planning of groundwater exploitation schemes within the study area.  相似文献   

8.
贵州岩溶地貌分布广泛,地质情况非常复杂,严重影响重大工程建设和地下水安全,文章提出一种改进的电法勘探技术,对不良地质体勘查取得了成功应用。以直流电法理论为基础,该方法是根据视电阻率微分统计原理,由电流密度分布规律与供电电极AB两极分布总存在着一定的对应关系,在野外同一供电测线(剖面)上,通过不断加密改变供电极距AB的位置,观测测量电极MN之间的电性参数变化,求取剖面相应纵向空间上,较大深度的(近地表的)近似连续视电阻率地电断面异常。此方法在深300 m以浅的岩溶区隐患排查中取得较好勘查效果,对煤矿钻孔及页岩气钻孔的选址探测误差能够控制在7%以内,值得进一步探索实践。  相似文献   

9.
The present study aims to explain some hydrogeological problems that are related to geological setting in two wadis: El Kallabiyyah and As Sabil East Esna. For this purpose, land magnetic, vertical electrical soundings, and two-dimensional electrical resistivity imaging profiles were measured. The lithological succession comprises Upper Cretaceous to Quaternary deposits that rest on a Precambrian basement rock. The results of the interpretation of the land magnetic measurements in wadi El Kallabiyyah represent the depth to the basement rock which ranges from 260 to 660 m and increases towards the northeast trend, but in wadi As Sabil, there is a large basin at the center of the wadi with the recorded depth to the basement reaching 1,300 m due to the effect of two normal faults (F1 and F2). The results of the interpretation of the vertical electrical sounding and two-dimensional imaging confirmed the presence of these faults in wadi As Sabil. The results of the geoelectrical measurements in wadi El Kallabiyyah represented the water-bearing layer at the third unit that consists of sands, gravels, boulders, and clays. The presence of clay will affect the potentiality of a drilled well. For wadi As Sabil, the results of geoelectrical measurements led to the lower part of the second unit which acts as a water-bearing layer that consists of sands, boulders, gravels, and clays. It can be concluded that the best site for drilling wells in wadi El Kallabiyyah is at vertical electrical sounding no.5 with a total depth of not less than 230 m. In wadi As Sabil, the drilled wells must be concentrated at the center and the downstream.  相似文献   

10.
The objective of this study was to assess the subsurface strata and groundwater situation of Olomoro, Nigeria using borehole logging and electrical resistivity techniques. The borehole logging consisting of resistivity and spontaneous potential logs were conducted by using the Johnson Keck logger on a drilled well in the study area. The electrical resistivity survey involving 17 vertical electrical soundings (VES) with a maximum current electrode spacing of 100 to 150 m was conducted using the Schlumberger electrode configuration. Analysis of the well cuttings revealed that the lithology of the subsurface consist of topsoil, clay, very fine sand, medium grain sand, coarse sand and very coarse sand. Results of the downhole logging also revealed that the mean electrical conductivity and the total dissolved solid of the groundwater was obtained as 390 μS/cm and 245 mg/cm3 respectively. These values are within the acceptable limit set by the Standard Organization of Nigeria (SON) for drinking water. The result of the vertical electrical sounding interpreted using the computer iterative modeling revealed the presence of four to five geoelectric layers which showed a close correlation with result from the lithology and downhole logging. Results further showed that the resistivity of the subsurface aquifer ranged between 1584 and 5420 Ωm while the aquifer depths varied between 27.8 and 39.3 m. Groundwater development of the area is suggested using the depth and resistivity maps provided in this study.  相似文献   

11.
Integrated geophysical techniques including resistivity image, vertical electrical sounding (VES), and seismic refraction have been conducted to investigate the Wadi Hanifah water system. The groundwater in Wadi Hanifah has problems caused by the high volumes of sewage water percolating into the ground. The combination of VES, resistivity image, and seismic refraction has made a valuable contribution to the identification of the interface between the contaminated and fresh water in Wadi Hanifah area. The contaminated groundwater has lower resistivity values than fresh groundwater due to the higher concentration of ions which reduces the resistivity. Resistivity image and sounding in this area clearly identified the nature of the lithological depth and proved useful at identifying water-bearing zones. Fresh groundwater was found in the study area at a depth of 100 m within the fractured limestone. Water-bearing zones occur in two aquifers, shallow contaminated water at 10 m depth in alluvial deposits and the deeper fresh water aquifer at a depth of about 100 m in fractured limestone. The interface between the contaminated water (sanitary water) and fresh water marked out horizontally at 100 m distance from the main channel and vertically at 20 m depth.  相似文献   

12.
In the Ouled Abdoun sedimentary basin (Morocco), the phosphatic series is composed of regular interbedded phosphatic and marly limestone layers. Some phosphatic deposits in this basin show sterile bodies causing two kinds of problems: (1) as they are hard, compact and masked by a Quaternary cover, they disturb the exploitation in some yards and give bad reserve calculations; (2) even the use of wells and mechanical boreholes did not evidence their delimitation. Therefore, electric prospecting method has been used to evidence their geometrical shape. Petrographical and geometrical studies on these sterile bodies allowed us to choose the appropriate geophysical method to map them. The electrical resistivity survey that we used in the Sidi Chennane area shows that this technique is a good tool to contour these sterile bodies. This method is now considered as useful to the mining engineers to get round them during the exploitation. To cite this article: A. Kchikach et al., C. R. Geoscience 334 (2002) 379–386.  相似文献   

13.
The integrated geophysical interpretation for the different geophysical tools such as resistivity and gravity is usually used to define the structural elements, stratigraphic units, groundwater potentiality, and depth to the basement rocks. In the present work, gravity and resistivity data were utilized for detecting the groundwater aquifer and structural elements, as well as the upper and lower surfaces of the subsurface basaltic sheet in an area located at the eastern side of Ismailia Canal, northeastern Greater Cairo, Egypt. Two hundred and ten gravity stations were measured using an Autograv instrument through a grid pattern of 50?×?50 m. The different required corrections were carried out, such as drift, elevation, tide, and latitude corrections. The final corrected data represented by the Bouguer anomaly map were filtered using high- and low-pass filters into regional and residual gravity anomaly maps. The resulting residual gravity anomaly map was used for gravity modeling to calculate the depths to the upper and lower surfaces of the basaltic sheet. The resulting gravity models indicated that the depths to the upper surface of the basaltic sheet are ranged between 26 and 314 m, where the shallower depths were found around the southern and eastern parts. The depths to the lower surface of the basaltic sheet are varied from 86 to 338 m, and the thickness of the basaltic sheet is ranged from 24 to 127 m, where the biggest thicknesses were found around the southern and northern parts of the study area. Forty-two vertical electrical soundings (VES) were carried out using Schlumberger configuration with AB/2 spacings ranged from 1.5 to 500 m. 1D quantitative interpretation was carried out through manual and analytical interpretations. The VES data were also inverted assuming a 3D resistivity distribution. The results from the 3D resistivity inversion indicated that the subsurface section consists of sand, sandstone, and sandy–clays of Miocene deposits overlying the basalts. Such basaltic features (of Oligocene age) are underlain by Gabal Ahmar Formation of Oligocene deposits, which are composed of sand and sandstone. Therefore, two aquifers were deduced in the area. The first is the Miocene aquifer (shallower) and the other is the Oligocene aquifer (deeper).  相似文献   

14.
Hydrogeophysical investigations of the Pleistocene aquifer at the Kom Hamada area, Egypt, have been conducted to determine the characteristics of groundwater. The main water-bearing formations in the study area are composed of Quaternary deposits. Water samples were taken and chemically analyzed at 29 sites. The constructed iso-salinity contour map of the study area showed an increase in salinity from 451.75 mg/l at eastern parts to 1,091.85 mg/l at western parts. The groundwater of the study area showed a hydrochemical evolution from Ca–HCO3 at the eastern side to Na–Cl at the western side. Some of groundwater constituents have high concentration values exceeding the safe limit for drinking. Eighteen vertical electrical soundings (VES) were conducted in the study area. These soundings were conducted near existing wells to obtain layer parameters of the various penetrated layers and to calculate the petrophysical characteristics of the aquifers. The resistivity of the first water-bearing layer ranges between 34 and 47 Ω m. The thickness of this layer ranges between 26 and 79 m. This layer represents the first aquifer, where it is followed by another water-bearing layer with resistivity ranges between 29 and 62 Ω m and extends downward. The two aquifers are hydraulically connected. Variation of the resistivities of these two water-bearing layers is mainly due to the lithological variation. The resistivity values along with the TDS values of the two water-bearing layers indicate fresh to brackish water types.  相似文献   

15.
Southwestern Madagascar is a semi-arid region and a hot-spot of global change. On the Mahafaly plateau, people live with quasi-permanent water stress and groundwater, the only available resource, is difficult to exploit due to a complex hydrogeological environment. A methodology (suitable for humanitarian projects; <?40 k€) was developed in four phases to assess the sustainable exploitation of the water resource: (A) regional scale exploration, (B) village scale exploration, (C) drilling campaign, and (D) hydro-climatic monitoring. This integrated hydrogeophysical approach involves geophysical measurements (262 TEM-fast soundings, 2588 Slingram measurements, 35 electrical soundings), hydrochemical analyses (112 samples), and a piezometric survey (127 measurements). Two groundwater resources were identified, one deep (below 150 m) and one shallow (<?20 m). Hydrochemical results highlighted the vulnerability of both resources: anthropic contamination for the shallower and seawater intrusion for the deeper. Therefore, subsequent geophysical surveys supported the siting of six boreholes and three wells in the shallow aquifer. This methodological approach was successful in this complex geological setting and requires testing at other sites in and outside Madagascar. The study demonstrates that geophysical results should be used in addition to drilling campaigns and to help monitor the water resource. In fact, to prevent over-exploitation, piezometric and meteorological sensors were installed to monitor the water resource. This unique hydro-climatic observatory may help (1) non-governmental organization and local institutions prevent future water shortages and (2) scientists to understand better how global change will affect this region of the world.  相似文献   

16.
Surface geophysics and a priori information were employed to delineate the subsurface geology at Idi-oro in Abijo, Ibeju Lekki area of Lagos, Nigeria for foundation investigation purpose. Resistivity measurement was conducted using 1-D and 2-D resistivity probing techniques. The resistivity measurements were made with ABEM tetrameter model SAS 1000 system. The 1-D vertical electrical resistivity sounding data were obtained using the Schlumberger electrode array while the 2-D resistivity data were obtained using the dipole–dipole array. The interpreted results revealed three to five subsurface geological layers. This is made up of the top soil with resistivity values that vary from 132.4 to over 2,313.5 Ω?m and thickness values that range from 0.3 to 4.8 m, the fine sand with resistivity values that vary from 221.0 to 3,032.7 Ω?m and thickness values that range from 0.4 to 5.5 m, the medium sand with resistivity values that vary from 202.8 to 1,247.7 Ω?m and thickness values that range from 4.9 to 58.4 m. On the other hand, the clayey sand has the resistivity values that vary from 146.1 to 1,744.0 Ω?m and thickness values that vary from 2.2 to 26.3 m, while the coarse sand has resistivity values that vary from 238.3 to 14,313.9 Ω?m but with no thickness value because the current terminated in this layer. The resistivity data correlate well with borehole logs. On the whole, it is concluded that the investigated area has competent sand layer that can support medium to giant engineering structures with resistivity values that vary from 202 to 14,314 Ω?m and thickness values that vary from 0.8 to 58.4 m.  相似文献   

17.
Geoelectrical survey was carried out in the western delta region of River Vasista Godavari, Andhra Pradesh, India, for delineation of groundwater prospective zones due to acute shortage of water supply for various purposes. Forty-six vertical electrical soundings (VES) were done, employing the Schlumberger configuration with a maximum AB/2 of 160 m. The interpreted results of VES show four to five layers with variable thicknesses, such as topsoil zone (1.5–3 m), clay zone (0.84–32 m), finer sand zone (2–72 m), medium to coarse sand zone (4 to 28.8 m) and clay zone (1.2–∞ m), indicating a multi-aquifer system. These results are corroborated with the known lithologs of the study area. Further, the resistivity is also compared with electrical conductivity (EC) of groundwater observed nearby shallow wells representing buried channel (BC), flood plain (FP) and coastal (C) zones, which indicate slightly brackish to brackish water (EC: 1470–6010 µS/cm), whereas the groundwater observed from deep wells shows the fresh (EC: 726–1380 µS/cm), fresh to brackish (EC: 1010 to 3250 µS/cm), and brackish water (EC: 3020 to 4170 µS/cm) located in BC, FP and C zones, respectively. This survey reveals the prospective aquifer zones with potable water at VES locations of 4–6, 8, 10, 11, 14, 16–28, 33–36, 39 and 42–44, where the resistivity values vary from 10 to 40 Ω m. The slightly brackish and brackish water zones are also observed from the resistivity of less than 10 Ω m at shallow depth in BC (VES-22, 37, 38 and 46), FP (VES-1, 2, 7, 29, 30 and 40) and C (VES-3, 4, 9, 12, 13, 15, 31, 32, 41 and 45) zones. As a result, the present investigation has delineated the freshwater zones at shallow (<?12 m) and also at deeper depths (30–45 m) as prospective areas, where BC zone occurs. Freshwater pockets also identified in FP (VES-8 and 39) and C (VES-11, 14 and 15) zones. Thus, this study helps to solve the drinking and irrigation water problems.  相似文献   

18.
Four magnetotelluric soundings were carried out in 1993 in the region of the Copahue active volcano located at the border between Chile and Argentina (37°45′S, 71°18′W). Three soundings were located inside the caldera of the ancient stratovolcano (east of Copahue) and the fourth outside it. The soundings inside the caldera were situated at about 6, 11, and 14 km from the volcano. Digital data were obtained covering the range of periods from 1 sec to 10,000 sec using induction coils and a flux-gate magnetometer to obtain the magnetic data and Cu-SO4Cu electrodes for electric field measurements. The apparent resistivity curves corresponding to principal directions were analyzed in conjunction with the geological background in order to eliminate distortion — which is very important in this hot volcanic region. Then, 1D modellings were performed using the “normal” curves — i.e., curves without distortions. Using the apparent resistivity curves with distortions, 2D modelling was also performed along a profile perpendicular to the regional tectonic trend suggested by MT soundings into the caldera. Results show low resistivity values of about 3-15 Ωm between 9 km to 20 km depth in the crust, suggesting high temperatures, with minimum values of about 700°C with partially melted zones in the upper crust between 9 km to 20 km depth under the caldera. The presence of a possible sulphide-carbonaceous layer (SC layer) in the upper basement could play an important role in lowering the electrical resistivities because of its high electronic conductivity.  相似文献   

19.
Evaporite karst has intensively developed recently along the Dead Sea (DS) coastal area in Israel and Jordan. It takes place in very saline groundwater dissolving buried salt layers, causing collapse of the surface. In this paper, groundwater salinity throughout the DS coastal area is investigated using the Transient Electromagnetic (TEM) method. Twenty-eight TEM soundings along the DS coastal area were carried out close to observation boreholes to calibrate resistivity–salinity relationships. Groundwater electrical conductivity was measured in these boreholes, and its salinity was analyzed at the laboratory by the Geological Survey of Israel (GSI). Quantitative relationships between bulk resistivity (ρx), water resistivity (ρw) and chloride concentration (Ccl) were derived in the resistivity range less than 1.0 Ω·m that enabled to evaluate the salinity of the aquifer in in situ conditions. Average values of the effective porosity of sandy sediments, φe = 0.32, and of silty ones, φe = 0.44, were used to generate the corresponding Archie equations. The study has shown that a DS aquifer with bulk resistivity in the range of 0.55–1.0 Ω·m contains in pores brine with 50–110 gchloride/l of (22–50% of that in saturated conditions, respectively), i.e. it keeps the potential to dissolve up to 114–174 g/l of salt.  相似文献   

20.
This paper presents the combination of two complementary methods, magnetic and joint inversion of resistivity/TEM data, as an effective approach to characterize groundwater reservoirs. Twenty stations of transient electromagnetic (TEM) and vertical electrical soundings (VES) were measured and interpreted using a joint inversion technique to evaluate the subsurface low resistivity zones connected to the groundwater reservoir. A complementary survey including 871 land magnetic stations was carried out at the same area to detect the upper surface of the basaltic sheet, which represents the bottom of the Miocene aquifer in the study area. The geological log from one borehole drilled in the zone was used to partially calibrate the calculated models. The results revealed that the study area consists of five different geological units with ages ranging from Paleogene (Oligocene) to Quaternary. The methodology provides good results at a very low cost when compared with drilling boreholes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号