排序方式: 共有55条查询结果,搜索用时 296 毫秒
1.
2.
Although seismic isolation rubber bearings in bridges and buildings have proven to be a very effective passive method for reducing earthquake‐induced forces, a detailed mechanical modeling of the rubber that is used in bearings under large strains has not been established. Therefore, a 3D model of failure behavior and the design criteria for the safety evaluation of seismic isolation bearings have not yet been developed. This paper presents: (1) correlation‐based template‐matching algorithms to measure large strain fields of continua; (2) a failure criterion for rubber; and (3) the design criteria for the safety evaluation of laminated algorithms, data‐validation algorithms were developed and implemented to eliminate possible unrealistic displacement vectors present in the measured displacement field. The algorithms were successfully employed in the strain field measurement of LRB and rubber materials that are subjected to failure. The measured local strains for rubber material at failure were used to develop a failure criterion for rubber. The validity of the proposed criterion was evaluated by applying it to the LRB; the criterion was introduced into a 3D finite element model of LRB, compared with the experimental results of bearings failure, and verified. Finally, design criteria are proposed for LRB for the safety evaluation. Copyright © 2003 John Wiley & Sons, Ltd. 相似文献
3.
变刚度隔震保护装置试验研究 总被引:1,自引:1,他引:0
通过在距离隔震层一定位移处设置由弹簧和与其串联的限位挡板组成的变刚度保护装置作为第二道防线,成功地进行了五层框架的变刚度隔震保护模拟地震振动台试验。理论分析和试验结果表明,变刚度隔震保护装置能有效改变结构动力特性,减小隔震层的变形,使之限制在允许的范围内。 相似文献
4.
Experimental study of deformable connection consisting of buckling‐restrained brace and rubber bearings to connect floor system to lateral force resisting system 下载免费PDF全文
Georgios Tsampras Richard Sause Robert B. Fleischman Jose I. Restrepo 《地震工程与结构动力学》2017,46(8):1287-1305
This paper presents experimental and numerical studies of a full‐scale deformable connection used to connect the floor system of the flexible gravity load resisting system to the stiff lateral force resisting system (LFRS) of an earthquake‐resistant building. The purpose of the deformable connection is to limit the earthquake‐induced horizontal inertia force transferred from the floor system to the LFRS and, thereby, to reduce the horizontal floor accelerations and the forces in the LFRS. The deformable connection that was studied consists of a buckling‐restrained brace (BRB) and steel‐reinforced laminated low‐damping rubber bearings (RB). The test results show that the force–deformation responses of the connection are stable, and the dynamic force responses are larger than the quasi‐static force responses. The BRB+RB force–deformation response depends mainly on the BRB response. A detailed discussion of the BRB experimental force–deformation response is presented. The experimental results show that the maximum plastic deformation range controls the isotropic hardening of the BRB. The hardened BRB force–deformation responses are used to calculate the overstrength adjustment factors. Details and limitations of a validated, accurate model for the connection force–deformation response are presented. Numerical simulation results for a 12‐story reinforced concrete wall building with deformable connections show the effects of including the RB in the deformable connection and the effect of modeling the BRB isotropic hardening on the building seismic response. Copyright © 2016 John Wiley & Sons, Ltd. 相似文献
5.
Response of hybrid isolation system during a shake table experiment of a full‐scale isolated building 下载免费PDF全文
Keri L. Ryan Taichiro Okazaki Camila B. Coria Eiji Sato Tomohiro Sasaki 《地震工程与结构动力学》2018,47(11):2214-2232
A full‐scale 5‐story steel moment frame building was subjected to a series of earthquake excitations using the E‐Defense shake table in August, 2011. For one of the test configurations, the building was seismically isolated by a hybrid system of lead‐rubber bearings and low friction roller bearings known as cross‐linear bearings, and was designed for a very rare 100 000‐year return period earthquake at a Central and Eastern US soil site. The building was subject to 15 trials including sinusoidal input, recorded motions and simulated earthquakes, 2D and 3D input, and a range of intensities including some beyond the design basis level. The experimental program was one of the first system‐level full‐scale validations of seismic isolation and the first known full‐scale experiment of a hybrid isolation system incorporating lead‐rubber and low friction bearings. Stable response of the hybrid isolation system was demonstrated at displacement demands up to 550 mm and shear strain in excess of 200%. Torsional amplifications were within the new factor stipulated by the code provisions. Axial force was observed to transfer from the lead‐rubber bearings to the cross‐linear bearings at large displacements, and the force transfer at large displacements exceeded that predicted by basic calculations. The force transfer occurred primarily because of the flexural rigidity of the base diaphragm and the larger vertical stiffness of the cross‐linear bearings relative to the lead‐rubber bearings. 相似文献
6.
7.
铅芯叠层橡胶支座基础隔震结构双向地震反应分析 总被引:6,自引:1,他引:6
本文对铅芯叠层橡胶支座双向耦合恢复力模型进行了改进,采用基础隔震结构动力分析程序DABIS对铅芯叠层橡胶支座基础隔震结构进行了单向及双向地震反应对比分析。结果表明,在单向和双向地震作用下,基础隔震结构的加速度反应和位移反应较为接近,但在双向地震作用下,支座的最大位移明显大于单向地震作用时的支座最大位移,因而在确定支座最大位移时应考虑双向地震作用的影响。 相似文献
8.
近断层脉冲型地震动作用下隔震结构地震反应分析 总被引:17,自引:5,他引:17
隔震结构在远震场地减震效果良好,但是近断层地震动的明显的长周期速度和位移脉冲运动可能对隔震建筑等长周期结构的抗震性能和设计带来不利影响,需要深入探讨。本文首先讨论近断层地震动的长周期脉冲运动特征,然后以台湾集集地震8条典型近震记录和其它4条常用近震记录以及4条远震记录作为地震动输入,对两幢安装铅芯橡胶隔震支座的钢筋混凝土框架隔震结构进行非线性地震反应时程分析,通过比较探讨了算例计算结果,定量说明隔震结构的近震脉冲效应显著,是隔震设计不容忽视的问题。 相似文献
9.
10.