1.
Potassium chloride (KCl) and potassium bromide (KBr) tracers were used to explore the role of geologic structure on groundwater recharge and flow at the Fractured Rock Research Site in Floyd County, Virginia, USA. Tracer migration was monitored through soil, saprolite, and fractured crystalline bedrock for a period of 3 months with chemical, physical, and geophysical techniques. The tracers were applied at specific locations on the ground surface to directly test flow pathways in a shallow saprolite and deep fractured-rock aquifer. Tracer monitoring was accomplished with differential electrical resistivity, chemical sampling, and physical monitoring of water levels and spring discharge. KCl, applied at a concentration of 10,000 mg/L, traveled 160 m downgradient through the thrust fault aquifer to a spring outlet in 24 days. KBr, applied at a concentration of 5,000 mg/L, traveled 90 m downgradient through the saprolite aquifer in 19 days. Tracer breakthrough curves indicate diffuse flow through the saprolite aquifer and fracture flow through the crystalline thrust fault aquifer. Monitoring saline tracer migration through soil, saprolite, and fractured rock provided data on groundwater recharge that would not have been available using other traditional hydrologic methods. Travel times and flowpaths observed during this study support preferential groundwater recharge controlled by geologic structure.  相似文献   

2.
Electrical resistivity method is a versatile and economical technique for groundwater prospecting in different geological settings due to wide spectrum of resistivity compared to other geophysical parameters. Exploration and exploitation of groundwater, a vital and precious resource, is a challenging task in hard rock, which exhibits inherent heterogeneity. In the present study, two-dimensional Electrical Resistivity Tomography (2D-ERT) technique using two different arrays, viz., pole–dipole and pole–pole, were deployed to look into high signal strength data in a tectonically disturbed hard rock ridge region for groundwater. Four selected sites were investigated. 2D subsurface resistivity tomography data were collected using Syscal Pro Switch-10 channel system and covered a 2 km long profile in a tough terrain. The hydrogeological interpretation based on resistivity models reveal the water horizons trap within the clayey sand and weathered/fractured quartzite formations. Aquifer resistivity lies between ~3–35 and 100–200 Ωm. The results of the resistivity models decipher potential aquifer lying between 40 and 88 m depth, nevertheless, it corroborates with the static water level measurements in the area of study. The advantage of using pole–pole in conjunction with the pole–dipole array is well appreciated and proved worth which gives clear insight of the aquifer extent, variability and their dimension from shallow to deeper strata from the hydrogeological perspective in the present geological context.  相似文献   

3.
Geological transition zones are noted to be problematic in groundwater potential and development, due to their erratic and complex nature as well as characteristic of the subsurface lithologies. There were several occurrences of reported borehole failures and dry wells in these zones in Nigeria as a result of very scanty information that could serve as database for studying its groundwater potential. This study was therefore designed to generate hydrogeophysical data that could serve as baseline information on the groundwater potential in the study. In addition, to also delineate various subsurface lithologies present. Electrical resistivity survey for geophysical investigation was carried out using vertical electrical sounding (VES) technique. A total of 150 VES stations were purposively probed using Schlumberger electrode array. The interpreted data were used to produce geoelectric subsurface lithologies and to draw the geological section across the entire area. Various subsurface lithologies with their resistivities (Ωm) were delineated for basement complex (BC), transition zone (TZ), and sedimentary terrain (ST). In BC were topsoil, weathered zone, and fresh bedrock and in TZ were topsoil, sandy, laterite/clay, dry sand, sandstone, and fresh bedrock delineated while in the ST, topsoil, lateritic and sandy clay, dry sand, and the sandstone were delineated. In conclusion, the groundwater potential of the study area is largely been affected by the topography and the nature/composition of the Abeokuta Group that underlie the sedimentary part of the study area and the presence of thick laterite/clay unit of the basement complex portion of the study area.  相似文献   

4.
Hydrologic conceptual models of groundwater/surface-water interaction in a saprolite-fractured bedrock geological setting often assume that the saprolite zone is hydraulically more active than the deeper bedrock system and ignore the contribution of deeper groundwater from the fractured bedrock aquifer. A hydraulic, hydrochemical, and tracer-based study was conducted at Scott Creek, Mount Lofty Ranges, South Australia, to explore the importance of both the deeper fractured bedrock aquifer system and the shallow saprolite layer on groundwater/surface-water interaction. The results of this study suggest that groundwater flow in the deeper fractured bedrock zone is highly dynamic and is an important groundwater flow pathway along the hillslope. Deep groundwater is therefore a contributing component in streamflow generation at Scott Creek. The findings of this study suggest that hydrologic conceptual models, which treat the saprolite-fractured bedrock interface as a no-flow boundary and do not consider the deeper fractured bedrock in hydrologic analyses, may be overly simplistic and inherently misleading in some groundwater/surface-water interaction analyses. The results emphasise the need to understand the relative importance of subsurface flow activity in both of these shallow saprolite and deeper bedrock compartments as a basis for developing reliable conceptual hydrologic models of these systems.  相似文献   

5.
Integrated surface electrical resistivity and electromagnetic (EM) surveys were conducted in a hard-rock terrain of Southwestern Nigeria in the vicinity of active oxidation sewage treatment ponds. The aim was to detect soil contamination due to the spread of sewage effluent, locate possible leachate plumes and conductive lithologic layers, and access the risk of groundwater pollution in the vicinity of the sewage-ponds. Dipole–dipole resistivity profiling and very low frequency (VLF) data were acquired at 10-m intervals along five 200-m long east-west geophysical traverses. Resistivity sections obtained revealed four subsurface geologic layers comprised of lateritic clay, clayey sand/sand, weathered/fractured bedrock, and competent bedrock. A distinct low resistivity zone corresponding to the contamination plume (labeled B) was delineated from all the resistivity sections. This low zone extends into the weathered bedrock and possibly suggests contamination of this layer. The filtered real component of the processed VLF data detected three distinct anomaly zones that are representative of fractured zones filled with conductive fluids and/or lithologic boundaries that possibly serve as conduits for the movement of contaminated effluents. The results obtained from the two methods suggest possible contamination of the subsurface soil layers and groundwater in the vicinity of the sewage-ponds. The existence of this contaminated plume poses a serious threat to the ecosystem and health of the people living in the vicinity of the sewage-ponds.  相似文献   

6.
The increasing demand for freshwater has necessitated the exploration for new sources of groundwater, particularly in hard rock terrain, where groundwater is a vital source of freshwater. A fast, cost effective, and economical way of exploration is to study and analyze geophysical resistivity survey data. The present study area Omalur taluk, Salem District, Tamil Nadu, India, is overlain by Archaean crystalline metamorphic complex. The study area is a characteristic region of unconfined aquifer system. The potential for occurrence of groundwater in the study areas was classified as very good, good, moderate, and poor by interpreting the subsurface geophysical investigations, namely vertical electrical soundings, were carried out to delineate potential water-bearing zones. The studies reveal that the groundwater potential of shallow aquifers is due to weathered zone very low resistivity and very high thickness and the potential of deeper aquifers is determined by fracture zone very low resistivity and very high thickness area. By using conventional GIS method, the spatial distribution maps for different layer (top soil, weathered zone, first fracture zone, and second fracture zone) thicknesses were prepared. The geoelectrical approach was successfully applied in the study area and can be therefore easily adopted for similar environments.  相似文献   

7.
The use of wastewater for irrigation in sandy soil increases the pollution risk of the soil and may infiltrate to the shallow groundwater aquifer. In such environment, some important parameters need to be obtained for monitoring the wastewater in the unsaturated zone over the aquifer. These parameters include clay content, heterogeneities of the upper soils, depth to the aquifer and the variations of groundwater quality. In the present work, the efficiency of DC resistivity method in forms of 1-D and 2-D measurements was studied for wastewater monitoring in the Gabal el Asfar farm, northeast of Cairo, Egypt. Forty-one Schlumberger soundings (VES) were performed then followed by three pole-dipole 2-D profiles along some considered regions within the area. The resistivity measurements were integrated with the boreholes, hydrogeological and hydrochemical (surface and groundwater samples) information to draw a clear picture for the subsurface conditions. The obtained results were presented as cross sections and 3-D visualization to trace the clay intercalations within the unsaturated zone. In addition, a vulnerability map was created using the obtained results from 1-D Schlumberger survey and confirmed with the 2-D resistivity profiling. The obtained results have shown that the 2-D resistivity imaging technique is a powerful tool for mapping the small-scale variability within the unsaturated zone and the wastewater infiltration. However, limitations of resistivity techniques were observed in the area with limited resistivity contrast such as thin clay layers with brackish water background. Under that condition, the measured pattern of resistivity distributions depends on the applied electrode array, electrode spacing and using the available geological information during the inversion process.  相似文献   

8.
Hydrogeoenvironmental studies were carried out at the sewage-disposal site of Obafemi Awolowo University campus, Ile-Ife, Nigeria. The objective of the survey was to determine the reliability of the electrical-resistivity method in mapping pollution plumes in a bedrock environment. Fifty stations were occupied with the ABEM SAS 300C Terrameter using the Wenner array. The electrical-resistivity data were interpreted by a computer-iteration technique. Water samples were collected at a depth of 5.0 m in 20 test pits and analyzed for quality. The concentrations of Cr, Cd, Pb, Zn, and Cu are moderately above the World Health Organization recommended guidelines. Plumes of contaminated water issuing from the sewage ponds were delineated. The geoelectric sections reveal four subsurface layers, with increasing depth, lateritic clay, clayey sand/sand, and weathered/fractured bedrock, and fresh bedrock. The deepest layers, 3 and 4, constitute the main aquifer, which has a thickness of 3.1–67.1 m. The distribution of the elements in the sewage effluent confirms a hydrological communication between the disposal ponds and groundwater. The groundwater is contaminated, as shown by sampling and the geophysical results. Thus, the results demonstrate the reliability of the direct-current electrical-resistivity geophysical method in sensing and mapping pollution plumes in a crystalline bedrock environment. Electronic Publication  相似文献   

9.
Orthogonal set of 2D geoelectrical resistivity field data, consisting of six parallel and five perpendicular profiles, were collected in an investigation site using the conventional Wenner array. Seven Schlumberger soundings were also conducted on the site to provide ID layering information and supplement the orthogonal 2D profiles. The observed 2D apparent resistivity data were first processed individually and then collated into 3D data set which was processed using a 3D inversion code. The 3D model resistivity images obtained from the inversion are presented as horizontal depth slices. Some distortions observed in the 2D images from the inversion of the 2D profiles are not observed in the 2D images extracted from the 3D inversion. The survey was conducted with the aim of investigating the degree of weathering and fracturing in the weathered profile, and thereby ascertaining the suitability of the site for engineering constructions as well as determining its groundwater potential.  相似文献   

10.
A novel study on using geoelectrical resistivity, soil property, and hydrogeochemical analysis methods for delineating and mapping of heavy metal in aquifer system is presented in this paper. A total of 47 surveys of geoelectrical resistivity with Wenner configuration were conducted to determine the subsurface and the groundwater characteristics. The groundwater sample from 53 existing wells and 2 new wells has been analyzed to derive their water chemical content. The chemical analysis was done on the soil sample obtained from new two wells and from selected locations. The water and soil chemical analysis results from the new two wells were used as calibration in resistivity interpretation. The occurrence of heavy metal in aquifer system was expected to detect using the geoelectrical resistivity survey for the whole study area. The result of groundwater analysis shows that the groundwater sample contains a relatively low concentration of Fe (<?0.3 mg/L) elongating from the south up to the middle region. While in the middle and the northwestern, Fe concentration is relatively high (around 12 mg/L). Chemical analysis of soil sample shows that in the lower resistivity zone (<?18 Ωm), Al and Fe concentrations are comparatively high with an average of 68,000 and 40,000 mg/kg, respectively. Starting from the middle to the northwestern zone, the resistivity value appears to be low. It is definitely caused by higher Al and Fe concentration within the soil, and it is supported also by lower total anion content in the groundwater. While the resistivity value of more than 40 Ωm in aquifers is obtained in the zone which Fe concentration is relatively lower in the soil but not present in the groundwater. Correlation Fe concentration in the soil and Fe concentration in the groundwater sample shows the trend of positively linear; however, the Al concentration in soil has no correlation with Al content in groundwater. Finally, the probability of high heavy metal zone in the aquifer system is easily delineated by the distribution of geoelectrical resistivity presented in depth slice shapes which extend from the Boundary Range Composite Batholith in the north to the northwest.  相似文献   

11.
This paper addresses the application of integrated geoelectrical methods including induced polarization (IP), resistivity (RS), and self-potential (SP) for exploration and evaluation of the Marand (Iran) manganese deposit. The SP method was used for reconnaissance, in which five profiles were designed and surveyed with a reference electrode that was placed in a distance of at least 800 m far from the measurement points. For the conduct of RS and IP, a new array proposed by Ramazi (2005a), named combined resistivity profiling and sounding (CRSP) was used along nine profiles that made it possible to do sounding survey and produce apparent resistivity pseudo-sections. Some anomalies were detected by means of SP surveys along the profiles and some other were located from IP and RS pseudo-sections, and there was good consistency between anomalies detected by IP and RS and SP method. To check the efficiency of CRSP and in comparison with dipole–dipole array, in the location of profile no. 6, a profile with the dipole–dipole array was designed and surveyed. Finally, by integration of the results from the geoelectrical methods, some locations were suggested for borehole drilling. After drilling in those locations, cores were studied and compared with the results obtained from the geoelectrical methods that resulted in confirmation of the geoelectrical findings. The results obtained by the CRSP array have a match better than the drilling results.  相似文献   

12.
The Dhanbad district in Jharkhand faces acute water scarcity and is chronically drought-prone. The groundwater resources in the area have not been fully exploited. The present study was undertaken to evaluate the groundwater prospective zones. Landsat-5 Multi Spectral Scanner (MSS) data of band 2 and band 4 and false colour composite (FCC) of band 2, 3, 4 were interpreted visually to differentiate different hydromorphogeological units and to delineate the major trends of lineaments. The different geomorphic features identified are linear ridges, residual hills, and pediplain, buried pediment and dissected pediplain, besides lineaments. The study shows that the pediplain and buried pediments are promising zones for groundwater prospecting. The occurrence and movement of groundwater is restricted to the unconsolidated material, weathered and fractured rocks. For the selection of tube well sites, geoelectrical resistivity investigations have been carried out at the sites, which were found suitable based on hydrogeomorphological and hydrogeological studies. Twenty-six Vertical Electrical Soundings (VES) have been carried out by using Schlumberger electrode configuration, which have brought out 3 to 7 layered sub-surface layers. The resistivity of water-bearing weathered/fractured rocks varies from 120–150 ohm m. The integrated studies have revealed that the blue colour zones are most promising for groundwater exploration and dug wells may be dug up to depths of 30±5m.  相似文献   

13.
Integrated geophysical techniques including resistivity image, vertical electrical sounding (VES), and seismic refraction have been conducted to investigate the Wadi Hanifah water system. The groundwater in Wadi Hanifah has problems caused by the high volumes of sewage water percolating into the ground. The combination of VES, resistivity image, and seismic refraction has made a valuable contribution to the identification of the interface between the contaminated and fresh water in Wadi Hanifah area. The contaminated groundwater has lower resistivity values than fresh groundwater due to the higher concentration of ions which reduces the resistivity. Resistivity image and sounding in this area clearly identified the nature of the lithological depth and proved useful at identifying water-bearing zones. Fresh groundwater was found in the study area at a depth of 100 m within the fractured limestone. Water-bearing zones occur in two aquifers, shallow contaminated water at 10 m depth in alluvial deposits and the deeper fresh water aquifer at a depth of about 100 m in fractured limestone. The interface between the contaminated water (sanitary water) and fresh water marked out horizontally at 100 m distance from the main channel and vertically at 20 m depth.  相似文献   

14.
Integrated hydrogeochemical and geophysical methods were used to study the salinity of groundwater aquifers along the coastal area of north Kelantan. For the hydrogeochemical investigation, analysis of major ion contents of the groundwater was conducted, and other chemical parameters such as pH and total dissolved solids were also determined. For the geophysical study, both geoelectrical resistivity soundings and reflection seismic surveys were conducted to determine the characteristics of the subsurface and groundwater contained within the aquifers. The pH values range from 6.2 to 6.8, indicating that the groundwater in the study area is slightly acidic. Low content of chloride suggests that the groundwater in the first aquifer is fresh, with an average concentration of about 15.8 mg/l and high geoelectrical resistivity (>45 ohm m). On the other hand, the groundwater in the second aquifer is brackish, with chloride concentration ranging from 500 mg/l to 3,600 mg/l and very low geoelectrical resistivity (<45 ohm m) as well as high concentration of total dissolved solids (>1,000 mg/l). The groundwater in the third aquifer is fresh, with chloride concentrations generally ranging from 2 mg/l to 210 mg/l and geoelectrical resistivity of greater than 45 ohm m. Fresh and saltwater interface in the first aquifer is generally located directly in the area of the coast, but, for the second aquifer, both hydrogeochemical and geoelectrical resistivity results indicate that the fresh water and saltwater interface is located as far as 6 km from the beach. The considerable chloride ion content initially suggests that the salinity of the groundwater in the second aquifer is probably caused by the intrusion of seawater. However, continuous monitoring of the chloride content of the second aquifer indicated no significant changes with time, from which it can be inferred that the salinity of the groundwater is not affected by seasonal seawater intrusion. Schoeller diagrams illustrate that sulphate concentrations of the groundwater of the second aquifer are relatively low compared to those of the recent seawater. Therefore, this result suggests that the brackish water in the second aquifer is probably from ancient seawater that was trapped within the sediments for a long period of time, rather than due to direct seawater intrusion.  相似文献   

15.
Geoelectrical resistivity method involving vertical electrical sounding (VES) was carried out in a sedimentary environment to determine the suitability of the method for sub-surface groundwater investigations. The EC and TDS hydrochemical data in the study area clearly showed the influence of seawater intrusion. The abundance of the major cations and anions are in the following order, Na+ > Ca2+ > Mg 2+ > K+ = Cl- > HCO3- > SO42- > CO3 > NO3 > PO4. Results suggest that the groundwater in this study area is very hard and alkaline in nature. As indicated by Piper trilinear diagram, NaCl and Ca2+ - Mg2+–Cl- - SO42- facies are the dominant hydrochemical facies in the groundwater of Pearl city. The VES method by Schlamberger electrode array was applied in 12 locations, which is expected to represent the whole area. The resistivity meter (aquameter CRM 5OO) was used to collect the VES data by employing a Schlumberger electrode configuration, with half current electrode spacing (AB/2) ranging from 2 to 180 m and the potential electrode (MN) from 1 to 50 m. The resistivity data is then interpreted by WINSEV 1-D inversion program geoelectric software to entirely describe the aquifer system as well as the occurrence of groundwater. The outputs of sub-surface layers with resistivities and thickness presented in contour maps and 2-D views by using SURFER software were created. Accordingly, three zones with different resistivity values were detected, corresponding to three different formations: (1) a transition zone of sandy soil (aeolian deposits) thick formation, (2) strata’s saturated with fresh groundwater in the east disturbed by the presence of sandy shell limestone horizons, (3) a water-bearing formation in the west containing low saltwater horizons. The bedrock is encountered at an average depth of 95m. This study indicates that the groundwater reservoirs are mainly confined to the alluvial aquifer.  相似文献   

16.
Zarif  Fardous  Slater  Lee  Mabrouk  Mohamed  Youssef  Ahmed  Al-Temamy  Ayman  Mousa  Salah  Farag  Karam  Robinson  Judy 《Hydrogeology Journal》2018,26(4):1169-1185

Understanding and developing groundwater resources in arid regions such as El Salloum basin, along the northwestern coast of Egypt, remains a challenging issue. One-dimensional (1D) electrical sounding (ES), two-dimensional (2D) electrical resistivity imaging (ERI), and very low frequency electromagnetic (VLF-EM) measurements were used to investigate the hydrogeological framework of El Salloum basin with the aim of determining the potential for extraction of potable water. 1D resistivity sounding models were used to delineate geoelectric sections and water-bearing layers. 2D ERI highlighted decreases in resistivity with depth, attributed to clay-rich limestone combined with seawater intrusion towards the coast. A depth of investigation (DOI) index was used to constrain the information content of the images at depths up to 100 m. The VLF-EM survey identified likely faults/fractured zones across the study area. A combined analysis of the datasets of the 1D ES, 2D ERI, and VLF-EM methods identified potential zones of groundwater, the extent of seawater intrusion, and major hydrogeological structures (fracture zones) in El Salloum basin. The equivalent geologic layers suggest that the main aquifer in the basin is the fractured chalky limestone middle Miocene) south of the coastal plain of the study area. Sites likely to provide significant volumes of potable water were identified based on relatively high resistivity and thickness of laterally extensive layers. The most promising locations for drilling productive wells are in the south and southeastern parts of the region, where the potential for potable groundwater increases substantially.

  相似文献   

17.
Subsurface structures from two different districts of Istanbul, hosting waste and freshwater transmission lines, were imaged by geoelectrical method. The environmental impact on Ka??thane-Terkos freshwater transmission line is one of the issues. That waterline underwent a substantial landslide damage. The previous site selection of Ka??thane-Terkos line was only based on surface geological observations. Even though the pipeline was positioned away from the surface scarps of landslides, the pipes were damaged. To find out the reason, we made some vertical electrical sounding measurements using Schlumberger array in the region. We inverted the electrical sounding data using 2D inversion technique. The final geoelectrical images show main landslide failures, at about 10–30 m depth, which are overlain by debris with a resistivity value of with <6 Ω m. The geoelectrical findings reveal that a buried major failure surrounds the surface landslides behind. Consequently, the water infrastructure remains under the influence of landslide. Our second application site was the area of the Sazl?dere tunnel, which will transfer wastewater, polluting Sazl?dere dam, to the treatment plant. The geoelectrical images along Sazl?dere tunnel route show resistive (<100 Ω m) and moderately conductive (≤50 Ω m) structures along the tunnel axis, representing unaltered to highly weathered rocks, respectively. Furthermore, consecutive hidden fault zones which severely affect the construction process of the tunnel are detected and located.  相似文献   

18.
Geoelectrical resistivity investigation using Vertical Electrical Sounding (VES) technique was conducted at Port Blair, South Andaman Island, to locate the fractures in different formations and to decipher its groundwater potential. A total of 40 VES were carried out covering the entire study area using Schlumberger electrode configuration out of which 34 VES fall in Andaman Flysch formations and the remaining VES in Ophiolite formations. The interpreted resistivity results were integrated with nine borehole lithologs for the subsurface analysis. The combination of VES with borehole litholog data has provided a close correspondence on subsurface hydrogeological conditions. The interpreted VES data of various formations showed drastic variations in the resistivity ranging from higher in Ophiolite, moderate in Andaman Flysch and very low in valleys of Andaman Flysch formations. The study further revealed that the weathered and fractured volcanics of Ophiolite groups of rocks and sandstone that occur in the Andaman Flysch formations constitute the productive water bearing zones categorized as good groundwater potential zone. Based on the geoelectrical parameters, viz., thickness of layers and the layer resistivity values, a groundwater potential map was prepared, in which good, moderate, and poor groundwater zones were demarcated. Further, numerical, spatial and litho-geoelectric models of resistivity were analyzed in terms of groundwater potential and these models have thus enabled to prepare a comprehensive groundwater development and management plans proving its efficacy in this art of exploratory investigations.  相似文献   

19.
Gradient profiling (GP) has been successfully utilized as a preliminary tool to identify fractured zones saturated with groundwater in hard-rock areas of Robertsganj, Sonebhadra district, Uttar Pradesh, India. Conducting geoelectrical sounding at randomly selected places may not provide fruitful results since fractures are sparsely distributed in hard rocks. In gradient profiling, current electrodes with large separation remain fixed while the potential dipole is moved between the current electrodes in the central one-third portion of the profile at a small station interval. A GP survey was conducted along seven profiles having different lengths in two small sectors of the study area. Low resistive zones have been identified which correspond to the fractured zones. A few geoelectrical soundings were carried out to investigate the depth and thickness of the fractured zones. Two test boreholes, one drilled in each sector, yielded continuous discharge of fresh water (18,000–24,000 L/h). The present study confirms the findings of previous work that the GP survey is a powerful initial technique that identifies the presence of a fractured zone, especially in a hard-rock area covered with a thin soil layer.  相似文献   

20.
Geoelectrical resistivity techniques are increasingly being applied in addressing a wide range of hydrological, environmental, and geotechnical problems. This is due to their effectiveness in near-surface characterization. In the present study, a suite of vertical electrical soundings (VESs) was integrated with 2D geoelectrical resistivity and time-domain induced polarization (IP) imaging to characterize the near-surface and delineate the underlying aquifer in a sedimentary terrain. The geophysical survey was conducted as part of preliminary studies to evaluate the potential of groundwater resource in Iyana-Iyesi and Canaan Land area of Ota, southwestern Nigeria. A high-yield confined sandy aquifer overlain by a low-yield aquitard was delineated; overlying the aquitard is a very resistive and thick layer that is predominantly composed of kaolinitic swelling clay intercalated with phosphate mineral.  相似文献   