首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Wave Energy Converters (WECs) have excellent potential as a source of renewable energy that is yet to be commercially realised. Recent attention has focused on the installation of Oscillating Water Column (OWC) devices as a part of harbor walls to provide advantages of cost–sharing structures and proximity of power generation facilities to existing infrastructure. In this paper, an incompressible three–dimensional CFD model is constructed to simulate a fixed Multi–Chamber OWC (MC–OWC) device. The CFD model is validated; the simulation results are found to be in good agreement with experimental results obtained from a scale physical model tested in a wave tank. The validated CFD model is then used for a benchmark study of 96 numerical tests. These investigate the effects of the PTO damping caused by the power take–off (PTO) system on device performance. The performance is assessed for a range of regular wave heights and periods. The results demonstrate that a PTO system with an intermediate damping can be used for all chambers in the MC–OWC device for most wave period ranges, except for the long wave periods. These require a higher PTO damping. An increased incident wave height reduces the device capture width ratio, but there is a noticeable improvement for long wave periods.  相似文献   

2.
A pile-supported OWC breakwater is a novel marine structure in which an oscillating water column (OWC) is integrated into a pile-supported breakwater, with a dual function: generating carbon-free energy and providing shelter for port activities by limiting wave transmission. In this work we investigate the hydrodynamics of this novel structure by means of an analytical model based on linear wave theory and matched eigenfunction expansion method. A local increase in the back-wall draft is adopted as an effective strategy to enhance wave power extraction and reduce wave transmission. The effects of chamber breadth, wall draft and air chamber volume on the hydrodynamic performance are examined in detail. We find that optimizing power take-off (PTO) damping for maximum power leads to both satisfactory power extraction and wave transmission, whereas optimizing for minimum wave transmission penalizes power extraction excessively; the former is, therefore, preferable. An appropriate large enough air chamber volume can enhance the bandwidth of high extraction efficiency through the air compressibility effect, with minimum repercussions for wave transmission. Meanwhile, the air chamber volume is found to be not large enough for the air compressibility effect to be relevant at engineering scales. Finally, a two-level practical optimization strategy on PTO damping is adopted. We prove that this strategy yields similar wave power extraction and wave transmission as the ideal optimization approach.  相似文献   

3.
针对波浪能转换装置(WEC)研究重点主要集中在能量捕获效率方面,而忽略其附带的消波功能的问题。基于Open FOAM程序,建立垂荡浮子式波浪能发电装置与桩式约束的浮式防波堤的集成系统(OBC-FB)。主要研究WEC中的重要组件动力输出系统(PTO)对集成系统波能捕获效率及消波性能的影响。分析流体黏性影响下线性PTO系统的最优PTO阻尼特性。开发非线性电磁阻尼模型与线性PTO系统性能进行比较。结果显示,考虑黏性影响下线性的最优PTO阻尼系数略大于无黏的理论值;适当增大PTO阻尼系数可以获得更大的波能捕获宽度比(CWR),从而可以保证装置单位特征尺寸的波能转换效率更高,同时可以在更宽波况范围保证消波性能;相较于线性PTO阻尼系统,非线性电磁PTO阻尼系统可以更好地兼顾波能捕获效率和消波性能。因此,在OBC-FB集成系统的优化设计中,PTO阻尼系统是一个重要的优化参数。  相似文献   

4.
Understanding the hydrodynamic interactions between ocean waves and the oscillating water column (OWC) wave energy converter is crucial for improving the device performance. Most previous relevant studies have focused on testing onshore and offshore OWCs using 2D models and wave flumes. Conversely, this paper provides experimental results for a 3D offshore stationary OWC device subjected to regular waves of different heights and periods under a constant power take–off (PTO) damping simulated by an orifice plate of fixed diameter. In addition, a 3D computational fluid dynamics (CFD) model based on the RANS equations and volume of fluid (VOF) surface capturing scheme was developed and validated against the experimental data. Following the validation stage, an extensive campaign of computational tests was performed to (1) discover the impact of testing such an offshore OWC in a 2D domain or a wave flume on device efficiency and (2) investigate the correlation between the incoming wave height and the OWC front wall draught for a maximum efficiency via testing several front lip draughts for two different rear lip draughts under two wave heights and a constant PTO damping. It is found that the 2D and wave flume modelling of an offshore OWC significantly overestimate the overall power extraction efficiency, especially for wave frequencies higher than the chamber resonant frequency. Furthermore, a front lip submergence equal to the wave amplitude affords maximum efficiency whilst preventing air leakage, hence it is recommended that the front lip draught is minimized.  相似文献   

5.
The oscillating water column (OWC) device is in a leading position for wave power extraction but has not achieved fully commercial at the current stage. In addition to enhancing the OWC performance, installing OWCs on floating breakwaters, which owns the merits of both cost-sharing and offshore power supply, is a practicality with high economic viability. In this study, a series of wave-flume experiments were conducted in regular waves to examine the wave power extraction of a floating box-type breakwater with dual pneumatic chambers. The flow characteristics of the orifices used to simulate the PTOs was pre-calibrated through another series of experiments, so the power extraction in this study can be obtained with only the pressure measurement. The effects of wave period, chamber draft, water depth and arrangement of chambers on the power extraction were examined. Our experimental results showed that the power extraction was mainly due to the water column oscillation inside the chamber, and differentiation in the designed natural periods of dual chambers could widen the efficiency bandwidth of power extraction. The front chamber always played the main role in power extraction and its natural period should be designed against the dominating period of the wave spectrum; in contrast, the power extraction of the rear chamber was only a supplement and its natural period should be designed against longer waves which were more easily transmitted, thus a PTO of small power capacity maybe more realistic. It was also worth noting that the water column oscillation was more dependent on the wave period rather than controlled by the wave scattering under different water depths.  相似文献   

6.
浮式防波堤与振荡浮子式波浪能转换装置集成是一种较为合理的波浪能开发利用方式,基于方箱式浮式防波堤—波浪能转换集成系统和幕帘式防波堤的研究成果,提出了一种新型方箱—垂直挡浪板式浮式防波堤—波浪能转换集成系统,建立数学模型对该集成系统的水动力特性和能量输出特性进行研究。模型基于N-S方程,采用紧致插值曲线(CIP)方法结合浸没边界法(IBM)求解。运用数值模型探究在一定波浪条件下,动力输出系统(PTO)阻尼力的大小以及挡浪板对集成系统的水动力特性和能量转换特性的影响,得到如下结论:集成系统的俘获宽度比随PTO阻尼力的增大呈现先增大后减小的趋势,在阻尼力F_(PTO)=150 N时达到最大;相对于方箱型集成系统,增设0.1 m挡浪板后可使其最大俘获宽度比η_e提高33%左右;此外,集成系统的俘获宽度比随挡浪板长度增加而增大,增长趋势逐渐变缓,在挡浪板长度S_p=0.5 m时达到最大,此时俘获宽度比η_e=0.563 1。  相似文献   

7.
This paper presents the use of a modular raft Wave Energy Converter (WEC)-type attachment at the fore edge of a rectangular Very Large Floating Structure (VLFS) for extracting wave energy while reducing hydroelastic responses of the VLFS under wave action. The proposed modular attachment comprises multiple independent auxiliary pontoons (i.e. modules) that are connected to the fore edge of the VLFS with hinges and linear Power Take-Off (PTO) systems. For the hydroelastic analysis, the auxiliary pontoons and the VLFS are modelled by using the Mindlin plate theory while the linear wave theory is used for modelling the fluid motion. The analysis is performed in the frequency domain using the hybrid Finite Element-Boundary Element (FE-BE) method. Parametric studies are carried out to investigate the effects of pontoon length, PTO damping coefficient, gap between auxiliary pontoons, and incident wave angle on the power capture factor as well as reductions in the hydroelastic responses of the VLFS with the modular attachment. It is found that in oblique waves, the modular attachment comprising multiple narrow pontoons outperforms the corresponding rigid attachment that consists of a single wide pontoon with respect to the power capture factor and the reduction in the deflection of the VLFS. In addition, it is possible to have a considerable gap between pontoons without significantly compromising the effectiveness of the modular attachment.  相似文献   

8.
Oscillating Water Column (OWC) is one of the pioneer devices in harnessing wave energy; however, it is not fully commercialized perhaps due to the complicated hydrodynamic behavior. Previous studies are significantly devoted to OWC devices located in nearshore and coastal regions where incident wave energy would experience dissipation more than offshore. In this paper, a 1:15 scaled fixed offshore OWC model is tested in a large towing tank of National Iranian Marine Laboratory. Wave spectrum shape effect on the efficiency of the OWC model is addressed. Moreover, the paper investigates the effects of the geometric and hydrodynamic factors on OWC device efficiency and uncovers new points in nonlinear interaction occurring inside the chamber; i.e. sloshing. The results indicate that shape of the spectrum inside the chamber is affected by the type of incident wave spectrum, especially for long waves. Pierson–Moskowitz spectrum leaded to higher efficiency rather than JONSWAP spectrum at longer incident wave periods. According to efficiency analysis, increasing wave height may lead to air leakage from the chamber followed by vortex generation, which is a reason for decreasing the efficiency of the OWC device. Furthermore, no shift in the resonant period of the OWC model, due to wave height increase, was observed at the opening ratios equal or smaller than 1.28%. Spectral analysis of water fluctuation inside the OWC chamber illustrates two modes of sloshing. The first mode can be seen at short period waves while the second mode is visible at long period waves. The sloshing modes approximately vanish by increasing draft value.  相似文献   

9.
An Oscillating Water Column (OWC) device can output energy through reciprocating or unidirectional airflow. The unidirectional airflow is helpful to utilize a simple and high-efficiency unidirectional air turbine. The pentagonal BBDB proposed by us based on OWC principle can be regarded as a floating Oscillating Body and its Power Take-Off (PTO) consists of a chamber, a water column, a turbine and a generator. The Capture Width Ratio (CWR) of the pentagonal BBDB model with the reciprocating and unidirectional airflow was studied in this paper. The wave flume test results indicate the mean CWR of the pentagonal BBDB model with reciprocating airflow can reach up to 121.91% and the mean CWR of the model with unidirectional airflow could reach 100.94% during the whole wave cycle in regular waves. For irregular waves, the mean CWR of the model with the unidirectional airflow is as high as 62.83% during the whole wave cycle. Hopefully, the combination of the pentagonal BBDB with the check valve to output power during the air exhalation and conventional high-efficiency unidirectional turbine will improve the total efficiency of the BBDB.  相似文献   

10.
Compared with solar and wind energy, wave energy is a kind of renewable resource which is enormous and still under development. In order to utilize the wave energy, various types of wave energy converters (WECs) have been proposed and studied. And oscillating-body WEC is widely used for offshore deployment. For this type of WEC, the oscillating motion of the floater is converted into electricity by the power take off (PTO) system, which is usually mathematically simplified as a linear spring and a damper. The linear PTO system is characteristic of frequency-dependent response and the energy absorption is less powerful for off resonance conditions. Thus a nonlinear snap through PTO system consisting of two symmetrically oblique springs and a linear damper is applied. A nonlinear parameter γ is defined as the ratio of half of the horizontal distance between the two oblique springs to the original length of both springs. JONSWAP spectrum is utilized to generate the time series of irregular waves. Time domain method is used to establish the motion equation of the oscillating-body WEC in irregular waves. And state space model is applied to replace the convolution term in the time domain motion equation. Based on the established motion equation, the motion response of both the linear and nonlinear WEC is numerically calculated using 4th Runge–Kutta method, after which the captured power can be obtained. Then the influences of wave parameters such as peak frequency, significant wave height, damping coefficient of the PTO system and the nonlinear parameter γ on the power capture performance of the nonlinear WEC is discussed in detail. Results show that compared with linear PTO system, the nonlinear snap through PTO system can increase the power captured by the oscillating body WEC in irregular waves.  相似文献   

11.
Raft-type wave energy converter (WEC) is a multi-mode wave energy conversion device, using the relative pitch motion to drive its hydraulic power take-off (PTO) units for capturing energy from the ocean waves. The hydraulic PTO unit as its energy conversion module plays a significant role in storing large qualities of energy and making the output power smooth. However, most of the previous investigations on the raft-type WECs treat the hydraulic PTO unit as a linear PTO unit and do not consider the dynamics of the hydraulic circuit and components in their investigations. This paper is related to a two-raft-type WEC consisting of two hinged rafts and a hydraulic PTO unit. The aim of this paper is to make an understanding of the dynamics of the hydraulic PTO unit and how these affect the performance of the two-raft-type WEC. Therefore, a combined hydrodynamic and hydraulic PTO unit model is proposed to investigate and optimize the performance of the two-raft-type WEC; and based on the simulation of the combined model, the relationships between the optimal power capture ability, the optimal magnitude of the hydraulic PTO force and the wave states are numerically revealed. Results show that an approximately square wave type hydraulic PTO force is produced by the hydraulic PTO unit, which causes the performance of the two-raft-type WEC not to be sinusoidal and the energy capturing manner different from that of the device using a linear PTO unit; moreover, there is an optimal magnitude of the hydraulic PTO force for obtaining an optimal power capture ability, which can be achieved by adjusting the parameters of the hydraulic PTO unit; in regular waves, the optimal power capture ability as well as the optimal magnitude of the hydraulic PTO force normalized by the wave height presents little relationship with the wave height, mainly depends on the wave period; in irregular waves, the trends of the optimal power capture ability and the normalized optimal magnitude of the hydraulic PTO force against the peak wave periods at different significant wave heights are generally identical and show a good correlation. All means that the hydraulic PTO unit of the two-raft-type WEC can be tuned to the wave states, and these would provide a valuable guidance for the optimal design of its hydraulic PTO unit.  相似文献   

12.
The double-body heave wave energy converter(WEC) is one of the most conducive devices to absorb the wave energy from relative motion while the law of which is not well understood. This paper makes an in-depth study on this wave energy converter, by means of the combination of theoretical analysis and physical model experiment. The hydrodynamic characteristics and energy capture of the double-buoy under constant and linear Power Take-Off(PTO) damping are investigated. Influences of absolute mass and mass ratio are discussed in the theoretical model.Relative displacement amplitude and average power output are tested in the experiment to analyze the effect of the wave period and outer buoy's mass, while the capture width ratio(CWR) is also calculated. Results show that the wave period and mass of the buoys have a significant effect on the converter. Different forms of PTO damping have no influence on the optimal wave period and mass ratio of this device. It is recommended to select the double-buoy converter with a mass ratio of 0.80 and to place it in an area with the frequent wave period close to the natural period of the outer buoy to achieve the optimal energy capture.  相似文献   

13.
陈文  滕斌 《海洋工程》2014,32(6):59-67
基于势流理论,建立波浪与摆式波能转换装置作用的三维频域分析模型。应用数值模型对两种质量的摆式波能转换装置进行水动力分析,在考虑粘性阻尼作用的条件下,计算传动系统的最优扭阻系数。在最佳工况下,开展了波浪频率对摆板运动响应和俘获能量影响的系统研究,给出了波浪最佳频率范围、摆板振幅、能量俘获效率以及摆板表面的波动压强。  相似文献   

14.
This paper presents a nonlinear frequency domain model and uses this to assess the performance of a wave energy converter (WEC) array with a nonlinear power take-off (PTO). In this model, the nonlinear PTO forces are approximated by a truncated Fourier series, while the dynamics of the WEC array are described by a set of linear motion equations in the frequency domain, and the hydrodynamic coefficients are obtained with the boundary element method. A single heave absorber is firstly investigated to establish the accuracy of the new model in capturing the nonlinear behaviour of the pumping system. Subsequently, simulations of a 2D array with 18 WECs and a pillar in the centre (representing the tower of a wind turbine) are carried out to understand wave interference effects. Several optimisation strategies are proposed to improve the overall performance of the WEC array. These results demonstrate a computationally effective method for accounting for nonlinear effects in large WEC arrays. The proposed approach may potentially be applied for developing control algorithms for the adaptability of a 2D array to incoming wave excitation.  相似文献   

15.
Investigation on the Oscillating Buoy Wave Power Device   总被引:4,自引:0,他引:4  
SU  Yongling 《中国海洋工程》2002,16(1):141-149
An oscillating buoy wave power device (OD) is a device extracting wave power by an oscillating buoy. Being excited by waves, the buoy heaves up and down to convert wave energy into electricity by means of a mechanical or hydraulic device. Compared with an Oscillating Water Column (OWC) wave power device, the OD has the same capture vvidth ratio as the OWC does, but much higher secondary conversion efficiency. Moreover, the chamber of the OWC, which is the most expensive and difficult part to be built, is not necessary for the OD, so it is easier to construct an OD. In this paper, a nu-merical calculation is conducted for an optimal design of the OD firstly, then a model of the device is built and, a model test is carried out in a wave tank. The results show that the total efficiency of the OD is much higher than that of the OWC and that the OD is a promising wave power device.  相似文献   

16.
Phase control may substantially increase the power absorption in point-absorber wave energy converters. This study deals with validation of dynamic models and latching control algorithms for an oscillating water column (OWC) inside a fixed vertical tube of small circular cross-section by small-scale testing. The paper describes experimental and numerical results for the system's dynamics, using simple and practical latching control techniques that do not require the prediction of waves or wave forces, and which will be relevant to any type of point-absorbing devices.In the experimental set-up, the upper end of the tube was equipped with an outlet duct and a shut-off valve, which could be controlled to give a latching of the inner free surface movement. The pressure drop through the open valve is used as a simplified measure of the energy extraction. The control was realized by using the real-time measurement signals for the inner and outer surface displacement.A mathematical model of the system was established and applied in numerical simulation. In the case the OWC's diameter is much smaller than the wavelength and the wave amplitude much smaller than the draft, the free surface movement inside the tube can be described as an oscillating weightless piston. For this hydrodynamic problem an analytical solution is known. In addition, the mathematical model includes the effects of viscous flow losses, the air compressibility inside the chamber and the pressure drop across the valve. Experimental results were used to calibrate some of the model parameters, and the total model was formulated as a coupled system of six non-linear, first-order differential equations. Time-domain integration was used to simulate the system in order to test the control strategies and compare with experimental results.  相似文献   

17.
The present study proposed a floating multi-body wave energy converter composed of a floating central platform, multiple oscillating bodies and multiple actuating arms. The relative motions between the oscillating bodies and the floating central platform capture multi-point wave energy simultaneously. The converter was simplified as a forced vibration system with three degrees of freedom, namely two heave motions and one rotational motion. The expressions of the amplitude-frequency response and the wave energy capture width were deduced from the motion equations of the converter. Based on the built mathematical model, the effects of the PTO damping coefficient, the PTO elastic coefficient, the connection length between the oscillating body and central platform, and the total number of oscillating bodies on the performance of the wave energy converter were investigated. Numerical results indicate that the dynamical properties and the energy conversion efficiency are related not only to the incident wave circle frequency but also to the converter's physical parameters and interior PTO coefficients. By adjusting the connection length, higher wave energy absorption efficiencies can be obtained. More oscillating bodies installed result in more stable floating central platform and higher wave energy conversion efficiency.  相似文献   

18.
Eddy current brakes provide a versatile way of simulating the power take-off system (PTO) in model testing of small scale wave energy converters (WECs). This type of PTO simulator is based on the principle that a conductive material moving in a magnetic field generates a braking force proportional to its velocity. A bottom-hinged pitching plate WEC model has been designed using an eddy current brake as a PTO simulator. A dedicated electric current source unit was developed to provide a controllable and reliable level of DC current intensity to feed the magnetic field generating coils. Using a real-time data acquisition and control, this unit can be used to impose non-linear damping PTO characteristic curves in several types of WEC models based on eddy current brakes. In the present case, this current source has been used to simulate a constant damping PTO on a small scale pitching WEC model that has been tested in the IST wave flume. Two different cases were considered: one corresponding to a surface piercing plate and another to a fully submerged plate. Experimental results are presented for plate motion and for non-dimensional capture width.  相似文献   

19.
Classical frequency and time domain models of a single degree of freedom wave power device are presented. In the time domain, a convolution integral is conventionally used to represent the fluid dynamic radiation force, characterised by added mass and damping in the frequency domain. This integral is replaced by an approximate ordinary differential equation (ODE) model which is faster and more convenient in simulations. A time domain model of the fluid dynamics of an oscillating water column (OWC) device is derived to illustrate the technique. Digital simulations of the OWC are used to compare the accuracy of the classical and ODE models. The simulation of the ODE model runs about six times as fast as the classical model based on convolution, yet characterises the fluid dynamics accurately.  相似文献   

20.
This paper investigates by numerical simulation the influence of the Wells turbine aerodynamic design on the overall plant performance, as affected by the turbine peak efficiency and the range of flow rates within which the turbine can operate efficiently. The problem of matching the turbine to an oscillating water column (OWC) is illustrated by taking the wave climate and the OWC of the Azores power converter. The study was performed using a time-domain mathematical model based on linear water wave theory and on model experiments in a wave tank. Results are presented of numerical simulations considering several aerodynamic designs of the Wells turbine, with and without guide vanes, and with the use of a bypass pressure-relief valve.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号