首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Chromium (Cr) isotopes have been widely used in various fields of Earth and planetary sciences. However, high‐precision measurements of Cr stable isotope ratios are still challenged by difficulties in purifying Cr and organic matter interference from resin using double‐spike thermal ionisation mass spectrometry. In this study, an improved and easily operated two‐column chemical separation procedure using AG50W‐X12 (200–400 mesh) resin is introduced. This resin has a higher cross‐linking density than AG50W‐X8, and this higher density generates better separation efficiency and higher saturation. Organic matter from the resin is a common cause of inhibition of the emission of Cr during analysis by TIMS. Here, perchloric and nitric acids were utilised to eliminate organic matter interference. The Cr isotope ratios of samples with lower Cr contents could be measured precisely by TIMS. The long‐term intermediate measurement precision of δ53/52CrNIST SRM 979 for BHVO‐2 is better than ± 0.031‰ (2s) over one year. Replicated digestions and measurements of geological reference materials (OKUM, MUH‐1, JP‐1, BHVO‐1, BHVO‐2, AGV‐2 and GSP‐2) yield δ53/52CrNIST SRM 979 results ranging from ?0.129‰ to ?0.032‰. The Cr isotope ratios of geological reference materials are consistent with the δ53/52CrNIST SRM 979 values reported by previous studies, and the measurement uncertainty (± 0.031‰, 2s) is significantly improved.  相似文献   

2.
We present the first technique to obtain precise and accurate vanadium (V) stable isotope compositions by chemical isolation and multi‐collector inductively coupled plasma‐mass spectrometry (MC‐ICP‐MS). Separation of V from matrix elements was achieved via five separate ion exchange columns. The procedure quantitatively removed Ti and Cr, which contain direct isobaric interferences on the minor isotope 50V. Isotope compositions were determined using a conventional standard solution‐sample bracketing technique. The V isotope composition for an in‐house secondary standard solution from BDH Chemicals was δ51V = ?1.19 ± 0.12‰ (2s, n = 600), measured as the per mil deviation relative to the composition of a widely available Specpure Alfa Aesar (AA) vanadium solution. This represents an improvement in measurement precision on previous techniques of almost two orders of magnitude. The effects of adding Cr, Ti and S to standard solutions were explored to determine the robustness of protocols. Only very low levels of these elements could be tolerated to obtain precise and accurate isotope compositions and was achieved with the chemical purification procedure. Standard solutions from AA and BDH processed as unknowns through the entire chemical separation and measurement protocols returned 100% yields and the same isotopic compositions as those of unprocessed standard solutions.  相似文献   

3.
A new natural zircon reference material SA01 is introduced for U‐Pb geochronology as well as O and Hf isotope geochemistry by microbeam techniques. The zircon megacryst is homogeneous with respect to U‐Pb, O and Hf isotopes based on a large number of measurements by laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) and secondary ion mass spectrometry (SIMS). Chemical abrasion isotope dilution thermal ionisation mass spectrometry (CA‐ID‐TIMS) U‐Pb isotopic analyses produced a mean 206Pb/238U age of 535.08 ± 0.32 Ma (2s, n = 10). Results of SIMS and LA‐ICP‐MS analyses on individual shards are consistent with the TIMS ages within uncertainty. The δ18O value determined by laser fluorination is 6.16 ± 0.26‰ (2s, n = 14), and the mean 176Hf/177Hf ratio determined by solution MC‐ICP‐MS is 0.282293 ± 0.000007 (2s, n = 30), which are in good agreement with the statistical mean of microbeam analyses. The megacryst is characterised by significant localised variations in Th/U ratio (0.328–4.269) and Li isotopic ratio (?5.5 to +7.9‰); the latter makes it unsuitable as a lithium isotope reference material.  相似文献   

4.
The in situ measurement of Sr isotopes in carbonates by MC‐ICP‐MS is limited by the availability of suitable microanalytical reference materials (RMs), which match the samples of interest. Whereas several well‐characterised carbonate reference materials for Sr mass fractions > 1000 µg g?1 are available, there is a lack of well‐characterised carbonate microanalytical RMs with lower Sr mass fractions. Here, we present a new synthetic carbonate nanopowder RM with a Sr mass fraction of ca. 500 µg g?1 suitable for microanalytical Sr isotope research (‘NanoSr’). NanoSr was analysed by both solution‐based and in situ techniques. Element mass fractions were determined using EPMA (Ca mass fraction), as well as laser ablation and solution ICP‐MS in different laboratories. The 87Sr/86Sr ratio was determined by well‐established bulk methods for Sr isotope measurements and is 0.70756 ± 0.00003 (2s). The Sr isotope microhomogeneity of the material was determined by LA‐MC‐ICP‐MS, which resulted in 87Sr/86Sr ratios of 0.70753 ± 0.00007 (2s) and 0.70757 ± 0.00006 (2s), respectively, in agreement with the solution data within uncertainties. Thus, this new reference material is well suited to monitor and correct microanalytical Sr isotope measurements of low‐Sr, low‐REE carbonate samples. NanoSr is available from the corresponding author.  相似文献   

5.
Mathematical modelling was combined with experimental Cu isotope measurements to demonstrate the effect of the sample matrix in changing the absolute and relative abundances of spectral interferences from Ti and Cr species. This unforeseen non‐spectral effect, evidenced by variable inaccuracies of the different Zn‐normalised Cu isotope ratios, was investigated by comparing real sedimentary samples and artificial solutions intended to match the Cu:Ti:Cr ratios of the real samples after (one or two step) chromatographic processing. Artificial solutions showed positive bias in δ65CuX/Y with the magnitude depending on (a) the 6XZn/6YZn ratio used for normalisation, (b) the Ti/Cu ratio and (c) the transmission coefficient of the TiO species. In contrast, real samples showed different δ65CuX/Y patterns and displayed a more complex population of Ti and Cr oxides and hydroxides, giving rise to positive and negative inaccuracies that were two to six times higher compared with the artificial samples. The results evidence contrasting behaviour of Ti and Cr when forming polyatomic species in the plasma and stress that artificial solutions may fail to predict how residual elements interact with the analyte/dopant pair during MC‐ICP‐MS analyses. More importantly, the study shows that all Zn isotope ratios do not have the same merit in correcting for mass bias in the presence of matrix elements and should all be monitored to verify the absence of spectral interferences for Cu isotope measurements. In this respect, accurate Cu data could be generally obtained by a two‐step chromatographic purification providing a minimum reduction of ~ 21000 and ~ 3000 times the initial amounts of Ti and Cr, respectively.  相似文献   

6.
UV femtosecond laser ablation coupled to MC-ICP-MS provides a promising in situ tool to investigate elemental and isotope ratios by non-matrix-matched calibration. In this study, we investigate Fe isotope composition in siliceous matrices including biotite, hornblende, garnet, fayalite and forsterite (San Carlos Olivine), and an oceanic Fe–Mn crust using the iron reference material IRMM-014 for calibration. To test the accuracy of the laser ablation data, Fe isotope compositions were obtained independently by solution ICP-MS after chromatographic separation of Fe. Sample materials with low Cr content, i.e. biotite, hornblende, fayalite and the Fe–Mn crust, reveal δ56/54Fe and δ57/54Fe values that agree with those from solution ICP-MS data within the measured precision. For high Cr concentration (54Cr/54Fe >0.0001), i.e. in the garnet and forsterite sample, δ56/54Fe and δ57/54Fe values were derived from 57Fe/56Fe ratios as correction of the isobaric interference of 54Cr on 54Fe is unsatisfactory. This approach provides accurate results for both minerals. Moreover, the garnet crystal exhibits isotopic zonation with differences of 0.3‰ in δ56/54Fe showing that substantial heterogeneities exist in high-temperature metamorphic minerals. Multiple analyses of homogeneous sample materials reveal a repeatability of 0.1‰ (2 SD) for δ56/54Fe and 0.2‰ (2 SD) for δ57/54Fe, respectively. This study adds to the observations of Horn et al. (2006) who have shown that the determination of Fe isotope ratios in various matrices including iron alloys, iron oxides and hydroxides, iron sulfide and iron carbonates can be performed with high accuracy and precision at high spatial resolution using UV femtosecond laser ablation ICP-MS. These results demonstrate that femtosecond laser ablation ICP-MS is a largely matrix-independent method, which provides a substantial advantage over commonly employed nanosecond laser ablation systems.  相似文献   

7.
Stable carbon isotope analysis of terrestrial plant leaves preserved in Quaternary lake sediments has the potential to provide high‐resolution reconstructions of past climatic conditions. Preferably, δ13C measurements should be made on a single leaf component, e.g. cellulose, but this approach is often precluded by limited leaf availability. Previous work suggests that reliable palaeoclimatic information also may be derived from δ13C measurements on whole‐leaf tissue, given a similar degree of leaf decomposition between samples. Leaf δ13C data for 12 Scandinavian species of dwarf‐shrubs, shrubs and trees, and a comparison of δ13C data on recent and late Holocene Salix herbacea leaves, revealed that the δ13C signal registered by holocellulose is largely reflected by measurements on whole‐leaf tissue. Holocellulose was found to be consistently enriched in 13C, although this δ13C offset was smaller for subfossil leaves. This supports the use of δ13C measurements on whole‐leaf tissue for climate reconstruction, at least for leaves preserved in soft, late Holocene sediments with minimal diagenetic effects. Leaf carbon and nitrogen data on fresh leaves of the same 12 Scandinavian species, and corresponding data on late Holocene Salix herbacea leaves, suggest that the leaf C:N ratio is a suitable indicator of the degree of leaf decomposition. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

8.
Three tourmaline reference materials sourced from the Harvard Mineralogical and Geological Museum (schorl 112566, dravite 108796 and elbaite 98144), which are already widely used for the calibration of in situ boron isotope measurements, are characterised here for their oxygen and lithium isotope compositions. Homogeneity tests by secondary ion mass spectrometry (SIMS) showed that at sub‐nanogram test portion masses, their 18O/16O and 7Li/6Li isotope ratios are constant within ± 0.27‰ and ± 2.2‰ (1s), respectively. The lithium mass fractions of the three materials vary over three orders of magnitude. SIMS homogeneity tests showed variations in 7Li/28Si between 8% and 14% (1s), which provides a measure of the heterogeneity of the Li contents in these three materials. Here, we provide recommended values for δ18O, Δ’17O and δ7Li for the three Harvard tourmaline reference materials based on results from bulk mineral analyses from multiple, independent laboratories using laser‐ and stepwise fluorination gas mass spectrometry (for O), and solution multi‐collector inductively coupled plasma‐mass spectroscopy (for Li). These bulk data also allow us to assess the degree of inter‐laboratory bias that might be present in such data sets. This work also re‐evaluates the major element chemical composition of the materials by electron probe microanalysis and investigates these presence of a chemical matrix effect on SIMS instrumental mass fractionation with regard to δ18O determinations, which was found to be < 1.6‰ between these three materials. The final table presented here provides a summary of the isotope ratio values that we have determined for these three materials. Depending on their starting mass, either 128 or 512 splits have been produced of each material, assuring their availability for many years into the future.  相似文献   

9.
In order to constrain spatial variability in watermass conditions within the European Epicontinental Seaway prior to, during and after the Toarcian Oceanic Anoxic Event, carbon (δ13Cbel, δ13Ccarb) and oxygen (δ18Obel, δ18Ocarb) isotope records were obtained from three sections in the Grands Causses Basin (southern France). These data were then compared with similar records along a north–south transect across the European Epicontinental Seaway. As the conclusions reached here strongly depend on the reliability of belemnite calcites as archives of palaeoceanographic changes, an attempt was made to improve the understanding of isotope signals recorded in belemnite calcite. Intra‐rostral carbon and oxygen‐isotope data from six belemnite specimens belonging to the genus Passaloteuthis were collected. Intra‐rostral carbon‐isotopes are influenced by vital effects, whereas oxygen‐isotopes reflect relative changes in temperature and salinity. Palaeotemperatures calculated from δ18Obel‐isotope records from the Grands Causses Basin confirm relatively low temperatures throughout the Late Pliensbachian. Similar cool water conditions have previously been shown in Germany, England, Spain and Portugal. A temperature increase of up to 6 °C is observed across the Pliensbachian–Toarcian boundary. A pronounced negative shift of at least ?3‰ (Vienna‐Pee Dee Belemnite) is recorded in bulk carbonate carbon during the lower Harpoceras serpentinum zone, typical of the Toarcian Oceanic Anoxic Event. Before and after the Toarcian Oceanic Anoxic Event, a good correlation between δ13Ccarb and δ13Cbel exists, indicating well‐ventilated bottom‐waters and normal marine conditions. Instead, data for the Toarcian Oceanic Anoxic Event indicate the development of a strong north–south gradient in salinity stratification and surface‐water productivity for the Western Tethyan realm. This study thus lends further support to a pronounced regional overprint on carbon and oxygen‐isotope records in epicontinental seaways.  相似文献   

10.
Garnet grains from an intensely metasomatized mid‐crustal shear zone in the Reynolds Range, central Australia, exhibit a diverse assortment of textural and compositional characteristics that provide important insights into the geochemical effects of fluid–rock interaction. Electron microprobe X‐ray maps and major element profiles, in situ secondary ion mass spectrometry oxygen isotope analyses, and U–Pb and Sm–Nd geochronology are used to reconstruct their thermal, temporal and fluid evolution. These techniques reveal a detailed sequence of garnet growth, re‐equilibration and dissolution during intracontinental reworking associated with the Ordovician–Carboniferous (450–300 Ma) Alice Springs Orogeny. A euhedral garnet porphyroblast displays bell‐shaped major element profiles diagnostic of prograde growth zoning during shear zone burial. Coexisting granulitic garnet porphyroclasts inherited from precursor wall rocks show extensive cation re‐equilibration assisted by fracturing and fragmentation. Oxygen isotope variations in the former are inversely correlated with the molar proportion of grossular, suggesting that isotopic fractionation is linked to Ca substitution. The latter generally show close correspondence to the isotopic composition of their precursor, indicating slow intergranular diffusion of O relative to Fe2+, Mg and Mn. Peak metamorphism associated with shearing (~550 °C; 5.0–6.5 kbar) occurred at c. 360 Ma, followed by rapid exhumation and cooling. Progressive Mn enrichment in rim domains indicates that the retrograde evolution caused partial garnet dissolution. Accompanying intra‐mineral porosity production then stimulated limited oxygen isotope exchange between relict granulitic garnet grains and adjacent metasomatic biotite, resulting in increased garnet δ18O values over length scales <200 μm. Spatially restricted oxygen interdiffusion was thus facilitated by increased fluid access to reaction interfaces. The concentration of Ca in channelled fracture networks suggests that its mobility was enhanced by a similar mechanism. In contrast, the intergranular diffusion of Fe2+, Mg and Mn was rock‐wide under the same P–T regime, as demonstrated by a lack of local spatial variations in the re‐equilibration of these components. The extraction of detailed reaction histories from garnet must therefore take into account the variable length‐ and time‐scales of elemental and isotopic exchange, particularly where the involvement of a fluid phase enhances the possibility of measureable resetting profiles being generated for slowly diffusing components such as Ca and O, even at low ambient temperatures and relatively fast cooling rates.  相似文献   

11.
Sulfur isotope measurements in three sulfide (two pyrite and one pyrrhotite) samples on two epoxy mounts showed that the mount‐to‐mount variation of raw δ34S values was negligible when secondary ion mass spectrometry (SIMS) analytical settings remained stable. In consequence, an off‐mount calibration procedure for SIMS sulfur isotope analysis was applied in this study. YP136 is a pyrrhotite sample collected from northern Finland. Examination of thin sections with a polarising microscope, backscattered electron image analyses and wavelength dispersive spectrometry mapping showed that the sample grains display no internal growth or other zoning. A total of 318 sulfur isotope (spot) measurements conducted on more than 100 randomly selected grains yielded highly consistent sulfur isotope ratios. The repeatability of all the analytical results of 34S/32S was 0.3‰ (2s,= 318), which is the same as that of the well‐characterised pyrite reference materials PPP‐1 and UWPy‐1. Its δ34S value determined by gas mass spectrometry was 1.5 ± 0.1‰ (2s,= 11), which agrees with the SIMS data (1.5 ± 0.3‰, 2s) calibrated by pyrrhotite reference material Po‐10. Therefore, YP136 pyrrhotite is considered a candidate reference material for in situ sulfur isotope determination.  相似文献   

12.
Oceanic 87Sr/86Sr‐isotope ratios are strongly influenced by rates of silicate weathering and therefore linked not only to glaciation but also to sea‐level change. The present study combines analysis of sequence stratigraphy and basin architecture with Sr‐isotope stratigraphy in Miocene shallow‐water sediments in southern Portugal and Crete (Greece). The common method is to use smoothed global sea water Sr‐isotope reference curves but here a different approach is chosen. Instead, measured Sr‐isotope curves are correlated with unsmoothed reference curves by identification of similar fluctuations in the order of several 100 kyr. Transgressive intervals are characterized by increasing Sr‐isotope ratios interpreted as corresponding to intensified silicate weathering as a consequence of deglaciation, while lowstand deposits have low Sr‐isotope ratios. Comparison of Sr‐isotope curves and sedimentary sequences in the studied basins with independent global δ18O data and data on global sea‐level might suggest a general relationship, supporting a connection to global climate change. Because of these relationships, the method presented herein has a high potential for use in high‐resolution age dating and is also applicable in shallow‐water sediments.  相似文献   

13.
Chalcopyrite is an important sulfide mineral in many types of ore deposits, but matrix‐matched chalcopyrite reference materials for microanalysis are lacking. A new natural chalcopyrite‐bearing specimen (HTS4‐6) was analysed in this study to investigate its potential as a reference material for microbeam sulfur isotope ratio measurement. Detailed textural examination and major element determination showed that the HTS4‐6 chalcopyrite grains have no growth rim or zoning. A total of 607 sulfur isotope ratio spot measurements with secondary ion mass spectrometry (SIMS) conducted on the cruciform sections, and over 120 randomly selected grains yielded highly consistent sulfur isotope ratio. The intermediate measurement precision for four measurement sessions of the 34S/32S measurement results was better than 0.39‰ (2s). Randomly selected chalcopyrite grains of HTS4‐6 were further analysed by LA‐MC‐ICP‐MS, which gave a mean δ34S value of +0.58 ± 0.38‰ (2s, n = 95). The maximum variance (expressed as intermediate precision from SIMS and LA‐MC‐ICP‐MS measurements) is not worse than 0.39‰ (the SIMS value), indicating that HTS4‐6 chalcopyrite is a potential reference material for in situ microbeam sulfur isotope measurements. The mean δ34S value determined by gas source isotope ratio mass spectrometry (GS‐IRMS) is +0.63 ± 0.16‰ (2s, n = 23), consistent with that derived by LA‐MC‐ICP‐MS, and can represent the recommended value for this potential reference material.  相似文献   

14.
This contribution presents data for laser ablation multicollector ICP‐MS (LA‐MC‐ICP‐MS) analyses of NIST SRM 610 and 612 glasses with the express purpose of examining the Pb isotope homogeneity of these glasses at the ~ 100 μm spatial scale, relevant to in situ analysis. Investigation of homogeneity at these scales is important as these glasses are widely used as calibrators for in situ measurements of Pb isotope composition. Results showed that at the levels of analytical uncertainty obtained, there was no discernable heterogeneity in Pb isotope composition of NIST SRM 610 and also most probably for NIST SRM 612. Traverses across the ~ 1.5 mm glass wafers supplied by NIST, consisting of between 75 and 133 individual measurements, showed no compositional outliers at the two standard deviation level beyond those expected from population statistics. Overall, the measured Pb isotope ratios from individual traverses across NIST SRM 610 and 612 wafers closely approximate single normally‐distributed populations, with standard deviations similar to the average internal uncertainty for individual measurement blocks. Further, Pb isotope ratios do not correlate with Tl/Pb ratios measured during the analysis, suggesting that regions of volatile element depletion (marked by low Tl/Pb) in these glasses are not associated with changes in Pb isotope composition. For NIST SRM 610 there also appeared to be no variation in Pb isotope composition related to incomplete mixing of glass base and trace element spike during manufacture. For NIST SRM 612 there was some dispersion of measured ratios, including some in a direction parallel to the expected mixing line for base‐spike mixing. However, there was no significant correlation parallel to the mixing line. At this time this cannot be unequivocally demonstrated to result from glass heterogeneity, but it is suggested that NIST SRM 610 be preferred for standardising in situ Pb isotope measurements. Data from this study also showed significantly better accuracy and somewhat better precision for ratios corrected for mass bias by external normalisation to Pb isotope ratios measured in bracketing calibrators compared to mass bias corrected via internal normalisation to measured 205Tl/203Tl, although the Tl isotopic composition of both glasses appears to be homogeneous.  相似文献   

15.
This work presents an evaluation of various methods for in situ high‐precision Sr and Pb isotopic determination in archaeological glass (containing 100–500 μg g?1 target element) by nanosecond laser ablation multi‐collector‐inductively coupled plasma‐mass spectrometry (ns‐LA‐MC‐ICP‐MS). A set of four soda‐lime silicate glasses, Corning A–D, mimicking the composition of archaeological glass and produced by the Corning Museum of Glass (Corning, New York, USA), were investigated as candidates for matrix‐matched reference materials for use in the analysis of archaeological glass. Common geological reference materials with known isotopic compositions (USGS basalt glasses BHVO‐2G, GSE‐1G and NKT‐1G, soda‐lime silicate glass NIST SRM 610 and several archaeological glass samples with known Sr isotopic composition) were used to evaluate the ns‐LA‐MC‐ICP‐MS analytical procedures. When available, ns‐LA‐MC‐ICP‐MS results for the Corning glasses are reported. These were found to be in good agreement with results obtained via pneumatic nebulisation (pn) MC‐ICP‐MS after digestion of the glass matrix and target element isolation. The presence of potential spectral interference from doubly charged rare earth element (REE) ions affecting Sr isotopic determination was investigated by admixing Er and Yb aerosols by means of pneumatic nebulisation into the gas flow from the laser ablation system. It was shown that doubly charged REE ions affect the Sr isotope ratios, but that this could be circumvented by operating the instrument at higher mass resolution. Multiple strategies to correct for instrumental mass discrimination in ns‐LA‐MC‐ICP‐MS and the effects of relevant interferences were evaluated. Application of common glass reference materials with basaltic matrices for correction of ns‐LA‐MC‐ICP‐MS isotope data of archaeological glasses results in inaccurate Pb isotope ratios, rendering application of matrix‐matched reference materials indispensable. Correction for instrumental mass discrimination using the exponential law, with the application of Tl as an internal isotopic standard element introduced by pneumatic nebulisation and Corning D as bracketing isotopic calibrator, provided the most accurate results for Pb isotope ratio measurements in archaeological glass. Mass bias correction relying on the power law, combined with intra‐element internal correction, assuming a constant 88Sr/86Sr ratio, yielded the most accurate results for 87Sr/86Sr determination in archaeological glasses  相似文献   

16.
This study presents a high‐precision method to measure barium (Ba) isotope compositions of international carbonate reference materials and natural carbonates. Barium was purified using chromatographic columns filled with cation exchange resin (AG50W‐X12, 200–400 mesh). Barium isotopes were measured by MC‐ICP‐MS, using a 135Ba–136Ba double‐spike to correct mass‐dependent fractionation during purification and instrumental measurement. The precision and accuracy were monitored by measuring Ba isotope compositions of the reference material JCp‐1 (coral) and a synthetic solution obtained by mixing NIST SRM 3104a with other matrix elements. The mean δ137/134Ba values of JCp‐1 and the synthetic solution relative to NIST SRM 3104a were 0.21 ± 0.03‰ (2s,= 16) and 0.02 ± 0.03‰ (2s,= 6), respectively. Replicate measurements of NIST SRM 915b, COQ‐1, natural coral and stalagmite samples gave average δ137/134Ba values of 0.10 ± 0.04‰ (2s,= 18), 0.08 ± 0.04‰ (2s,= 20), 0.27 ± 0.04‰ (2s,= 16) and 0.04 ± 0.03‰ (2s,= 20), respectively. Barium mass fractions and Ba isotopes of subsamples drilled from one stalagmite profile were also measured. Although Ba mass fractions varied significantly along the profile, Ba isotope signatures were homogeneous, indicating that Ba isotope compositions of stalagmites could be a potential tool (in addition to Ba mass fractions) to constrain the source of Ba in carbonate rocks and minerals.  相似文献   

17.
Six tourmaline samples were investigated as potential reference materials (RMs) for boron isotope measurement by secondary ion mass spectrometry (SIMS). The tourmaline samples are chemically homogeneous and cover a compositional range of tourmaline supergroup minerals (primarily Fe, Mg and Li end‐members). Additionally, they have homogeneous boron delta values with intermediate precision values during SIMS analyses of less than 0.6‰ (2s). These samples were compared with four established tourmaline RMs, that is, schorl IAEA‐B‐4 and three Harvard tourmalines (schorl HS#112566, dravite HS#108796 and elbaite HS#98144). They were re‐evaluated for their major element and boron delta values using the same measurement procedure as the new tourmaline samples investigated. A discrepancy of about 1.5‰ in δ11B was found between the previously published reference values for established RMs and the values determined in this study. Significant instrumental mass fractionation (IMF) of up to 8‰ in δ11B was observed for schorl–dravite–elbaite solid solutions during SIMS analysis. Using the new reference values determined in this study, the IMF of the ten tourmaline samples can be modelled by a linear combination of the chemical parameters FeO + MnO, SiO2 and F. The new tourmaline RMs, together with the four established RMs, extend the boron isotope analysis of tourmaline towards the Mg‐ and Al‐rich compositional range. Consequently, the in situ boron isotope ratio of many natural tourmalines can now be determined with an uncertainty of less than 0.8‰ (2s).  相似文献   

18.
Atom probe microscopy (APM) is a relatively new in situ tool for measuring isotope fractions from nanoscale volumes (< 0.01 μm3). We calculate the theoretical detectable difference of an isotope ratio measurement result from APM using counting statistics of a hypothetical data set to be ± 4δ or 0.4% (2s). However, challenges associated with APM measurements (e.g., peak ranging, hydride formation and isobaric interferences), result in larger uncertainties if not properly accounted for. We evaluate these factors for Re‐Os isotope ratio measurements by comparing APM and negative thermal ionisation mass spectrometry (N‐TIMS) measurement results of pure Os, pure Re, and two synthetic Re‐Os‐bearing alloys from Schwander et al. (2015, Meteoritics and Planetary Science, 50, 893) [the original metal alloy (HSE) and alloys produced by heating HSE within silicate liquid (SYN)]. From this, we propose a current best practice for APM Re‐Os isotope ratio measurements. Using this refined approach, mean APM and N‐TIMS 187Os/189Os measurement results agree within 0.05% and 2s (pure Os), 0.6–2% and 2s (SYN) and 5–10% (HSE). The good agreement of N‐TIMS and APM 187Os/189Os measurements confirms that APM can extract robust isotope ratios. Therefore, this approach permits nanoscale isotope measurements of Os‐bearing alloys using the Re‐Os geochronometer that could not be measured by conventional measurement principles.  相似文献   

19.

This study uses carbon isotope chemostratigraphy to propose an age for the Success Creek Group and Crimson Creek Formation in the absence of any direct radiometric dates, palaeomagnetic or reliable palaeontological data. The δ13C values were determined for the least‐altered dolomite samples. Suitable samples were selected on the basis of grainsize, cathodoluminescence petrography, most enriched δ18O values (> 2%o) low Mn/Sr ratios and low Fe and Mn concentrations. The average least‐altered, most 13C‐enriched dolomicrite samples in the youngest (No. 1) dolomite horizon are + 4.6%o. This is typical of Neoproterozoic (but not Cambrian) carbonates. The δ13C values of all dolomite samples in the succession are significantly positive (up to + 7.5%o) and the excursion characteristic of the Proterozoic/Cambrian boundary has not been observed. The lack of negative δ13C values in all dolomite samples studied also suggests an absence of correlatives of Sturtian and Varanger tillites in the dolomite successions. The δ13C values in all three dolomite horizons suggest a Neoproterozoic age between about 820 to 570 Ma (Cryogenian to Neoproterozoic III) on the current global compilation carbon isotope curves. This age for the Success Creek Group and Crimson Creek Formation, inferred from carbon isotope chemostratigraphy, can be substantiated by other evidence. The age of the Renison dolomites is constrained by K‐Ar dates of 708 ± 6 Ma from detrital muscovite in the underlying Oonah Formation and 588 ± 8 and 600 ± 8 Ma from doleritic rock in a lithostratigraphic equivalent of the Crimson Creek Formation from the Smithton Basin. Furthermore, acritarchs and the stromatolite Baicalia cf. B. burra also suggest a Neoproterozoic rather than Cambrian age.  相似文献   

20.
Two quartz samples of igneous origin, UNIL‐Q1 (Torres del Paine Intrusion, Chile) and BGI‐Q1 (Shandong province, China), were calibrated for their oxygen isotope composition for SIMS measurements. UNIL‐Q1 and BGI‐Q1 were evaluated for homogeneity using SIMS. Their reference δ18O values were determined by CO2 laser fluorination. The average δ18O value found for UNIL‐Q1 is 9.8 ± 0.06‰ and that for BGI‐Q1 is 7.7 ± 0.11‰ (1s). The intermediate measurement precision of SIMS oxygen isotope measurements was 0.32–0.41‰ (2s; UNIL‐Q1) and 0.40–0.48‰ (2s; BGI‐Q1), respectively. While less homogeneous in its oxygen isotope composition, BGI‐Q1 is also suitable for SIMS trace element measurements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号