首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The initial discharge stages of two flashes during the Shandong Artificially Triggering Lightning Experiment (SHATLE) are analyzed based on the synchronous data of the current and close electromagnetic field. For a lightning flash, named 0503, the wire was connected, not electrically, but via a 5 m length of nylon, with the lightning rod; while for another, named 0602, the wire was connected with the rod directly. Results show that the discharge processes of the initial stage (IS) in flash 0503 are quite different from that of the usual classical-triggered flash 0602 and altitude-triggered flashes. A large pulse with a current of about 720 A resulted from the breakdown of the 5 m air gap during flash 0503, and the corresponding electric field at 60 m from the lightning rod was 0.38 kV/m. The upward positive leaders (UPLs) propagated continuously from the tip of the rocket after this breakdown. The geometric mean (GM) of the UPL peak current was 23.0 A. Vaporization of the wire occurred during the initial continuous current (ICC) stage and the largest current pulse was about 400 A. Compared with triggered flash 0503, the discharge processes of IS in flash 0602 were simple, only two large pulses similar to each other occurred before dart leader/return stroke sequences. The peak current of the first pulse was 2.1 kA and its corresponding electric field and magnetic field at a distance of 60 m from the lightning rod were 0.98 kV/m and 7.03 μT, respectively. During the second pulse, the wire disintegrated. The current decreased to the background level at the moment of the wire disintegration. The current of the second pulse in triggered flash 0602 was 2.8 kA, and the corresponding electric field and magnetic field at 60 m from the lightning rod were 1.22 kV/m and 9.01 μT, respectively.  相似文献   

2.
LINET—An international lightning detection network in Europe   总被引:1,自引:0,他引:1  
During the past years a VLF/LF lightning detection network (LINET) was developed at the University of Munich, which provides continuous data for both research and operational purposes. In particular, the network introduces five new features: a) total lightning capability: both cloud-to-ground strokes (CG) and cloud lightning (IC) are measured; b) low-amplitude reporting: weak lightning events from discharge channel with currents well below 5 kA are detected within the central part of the network, whereby IC events dominate; c) new 3D-discrimination: a time-of-arrival method is utilized to separate CG from IC with good reliability, provided that the sensor baseline does not exceed ~ 250 km; d) IC emission height: for each cloud event a height is determined which is thought to reflect the central region of the involved channel; and e) optimised location accuracy: due to precision and combined action of all influential network components, complemented by site-error corrections, the position accuracy of strokes reaches an average value as small as ~ 150 m, whereby false locations (‘outliers’) rarely occur. During international co-operations LINET has been deployed in four continents: Europe (initially Germany), South America (area of Bauru, Brazil), Australia (around Darwin), and Central Africa (Benin). Since the features quoted above could be verified in the tests, a 65-sensor network was established in Europe and started on May 1, 2006, in co-operation with the service company nowcast. LINET covers a wide area approximately from longitude − 10° to 25° to latitude 35° to 66°; it is available for scientific projects and officially utilized by the German Weather Service for operational purposes. Meanwhile, the network was extended by deployment of additional sites so that it comprises about 90 sensors in 17 countries.  相似文献   

3.
In July 2005, a field campaign was conducted in the Central Great Plains to obtain 60-field/s video imagery of lightning in correlation with reports from the U.S. National Lightning Detection Network (NLDN) and broadband electric field waveforms from the Los Alamos Sferic Array (LASA). A total of 342 GPS time-stamped cloud-to-ground (CG) flashes were recorded in 17 different sessions, and 311 (91%) of these were correlated with reports from the NLDN. Only 6 of the 17 recording sessions were dominated by flashes that lowered negative charge to ground, and 11 were dominated by positive CG flashes. A total of 103 flashes recorded on video were correlated with at least one NLDN report of negative CG strokes, 204 video flashes were correlated with one or two positive stroke reports, and 4 had bipolar reports. In this paper, we will give distributions of the estimated peak current, Ip, as reported by the NLDN, of negative and positive first strokes that were recorded on video, the multiplicity of strokes that were recorded on video, and the number of ground contacts per flash that were resolved on video. 41 (40%) of the negative flashes produced just a single-stroke on video, and 62 (60%) showed two or more strokes. The observed multiplicity of negative flashes averaged 2.83, which becomes about 3.14 after correcting for the finite time-resolution of the video camera. 195 (96%) of the positive flashes produced just a single-stroke on video, and 9 (4%) showed two strokes; therefore, the observed multiplicity of positive flashes averaged 1.04. Five out of 9 (56%) of the positive subsequent strokes re-illuminated a previous channel, and 4 out of 9 (44%) created a new ground contact. Simultaneous video, LASA, and NLDN measurements also allowed us to examine the classification of NLDN reports during 3 single-cell storms (one negative and two positive). Based on the LASA waveforms, a total of 204 out of 376 (54%) NLDN reports of CG strokes were determined to be for cloud pulses. The misclassified negative reports had |Ip| values ranging from 3.8 kA to 29.7 kA, but only 58 (24%) of these had |Ip| > 10 kA, and only one misclassified positive report had Ip > 20 kA. Radar analyses showed that most of the negative and positive CG strokes that were recorded on video were produced within or near the convective cores of storms. The radar imagery also showed that single-cell storms tended to produce one polarity of CG flashes at a time, and that such storms could switch rapidly from negative to positive CG flashes when the reflectivity was near maximum. Multiple-cell storms produced both negative and positive flashes over a broad region, but each polarity tended to cluster near regions of high-reflectivity.  相似文献   

4.
Study of the total lightning activity in a hailstorm   总被引:1,自引:0,他引:1  
A thunderstorm that developed over northeastern Spain on 16 June 2006 is analyzed. This severe thunderstorm produced hailstones as large as 40 mm and had a lifetime of 3 h and 30 min. Radar cross-sections show strong vertical development with cloud echo tops reaching an altitude of 13 km. The specific characteristics of the lightning activity of this storm were: (i) a large amount (81%) of negative cloud-to-ground (−CG) flashes with very low peak currents (< 10 kA in absolute value), (ii) a very large proportion of intra-cloud (IC) flashes with an IC/CG ratio reaching about 400, (iii) a large number of “short” IC flashes (with only 1-VHF source according to SAFIR detection), (iv) a large increase of the −CG flash rate and of the CG proportion near the end of the storm. The rate of −CG flashes with a low peak current were observed to evolve similarly to the rates of IC flashes. Most of them have been assumed to be IC flashes misclassified by the Spanish Lightning Detection Network (SLDN). They have been filtered as it is usually done for misclassified +CG flashes. After this filtering, CG flash rates remained very low (< 1 min− 1) with +CG flashes sometimes dominant. All the particular lightning activity characteristics similar to those observed in the Severe Thunderstorm Electrification and Precipitation Study (STEPS) campaigns support the hypothesis that this thunderstorm could have had an inverted-polarity or complex charge structure. The maximum IC flash rate (67 min− 1) peaked 24 min before the presence of reflectivity higher than 60 dBZ. The IC activity abruptly decreased during the period when reflectivity was dramatically increasing. The time of maximum reflectivity observed by radar was consistent with the times of reported hail at the ground.  相似文献   

5.
We have analyzed the fine-structure of 131 electric field (E) waveforms that were radiated during the onset of first return strokes in cloud-to-ocean lightning. The dE/dt waveforms were recorded using an 8-bit waveform digitizer sampling at 100 MHz, and the E waveforms were sampled at 10 MHz using a 10-bit digitizer. 49 (or 37%) of the dE/dt waveforms contain one or more large pulses within ± 1 μs of the largest (or dominant) peak in dE/dt, i.e. within an interval from − 1 μs to + 1 μs, where t = 0 μs is the time of the dominant peak, and 37 (or 28%) have one or more large pulses in the interval from 4 μs before to 1 μs before the dominant peak, i.e. − 4 μs to − 1 μs, and only the dominant peak within ± 1 μs . We give statistics on the amplitude and timing of dE/dt pulses that are near the dominant peak, and we show how the presence of these pulses adds considerable fine-structure to the shape of Eint, the integrated dE/dt waveform, on a time-scale of tens to hundreds of nanoseconds. This fine-structure includes fast pulses near the beginning of the slow front, large pulses and shoulders within the slow front and during the fast-transition, and very narrow peaks in Eint. Our overall conclusion is that the electromagnetic environment near the point(s) where lightning leaders attach to the surface is often more complicated than what would be produced by a single current pulse propagating up a single channel at the time of onset.  相似文献   

6.
广东野外雷电综合观测试验十年进展   总被引:12,自引:0,他引:12  
雷电野外科学试验是认识雷电发生、发展物理过程及其致灾机理的重要途径,也是开展真实雷电电磁环境下雷电防护技术测试的重要方式。自2006年开始,中国气象科学研究院和广东省气象局在广州野外雷电试验基地,持续合作开展了雷电野外综合观测试验,在人工触发闪电和自然闪电物理过程及其雷电防护技术测试试验等方面取得了若干研究结果。十年期间共成功触发闪电94次,回击电流峰值最大值为42 kA,平均值为16 kA;分析给出了自然闪电预击穿过程电场变化脉冲特征类型和差异;观测发现高建筑物上行连接先导可达几百米甚至超过1 km,其发展速度可达106 m/s量级,下行先导与上行连接先导的连接呈多样性;雷电防护技术测试试验表明人工触发闪电近距离电磁场耦合在架空线路上的感应电压达到千伏量级,多回击、长连续电流和地电位抬升是造成浪涌保护器(SPD)损害的主要因素;闪电定位系统探测性能的评估结果显示粤港澳闪电定位系统的闪电和回击的探测效率分别为96%和89%,定位误差算术平均值为532 m,回击电流强度的估算值约为真实值的0.63倍。  相似文献   

7.
During the summers of 2003 to 2006 sprites were observed over thunderstorms in France by cameras on mountain tops in Southern France. The observations were part of a larger coordinated effort, the EuroSprite campaigns, with data collected simultaneously from other sources including the French radar network for precipitation structure, Meteosat with images of cloud top temperature and the Météorage network for detection of cloud-to-ground (CG) flash activity. In this paper two storms are analyzed, each producing 27 sprite events. Both storms were identified as Mesoscale Convective Systems (MCS) with a trailing stratiform configuration (ST) and reaching a maximum cloud area of ~ 120,000 km2. Most of the sprites were produced while the stratiform area was clearly developed and during periods of substantial increase of rainfall in regions with radar reflectivity between 30 and 40 dBZ. The sprite-producing periods followed a maximum in the CG lightning activity and were characterized by a low CG flash rate with a high proportion of + CG flashes, typically around 50%. All sprites were associated with + CGs except one which was observed after a − CG as detected by the Météorage network. This − CG was estimated to have − 800 C km charge moment change. The peak current of sprite-producing + CG (SP + CG) flashes was twice the average value of + CGs and close to 60 kA with little variation between the periods of sprite activity. The SP + CG flashes were further characterized by short time intervals before a subsequent CG flash (median value < 0.5 s) and with clusters of several CG flashes which suggest that SP + CG flashes often are part of multi-CG flash processes. One case of a lightning process associated with a sprite consisted of 7 CG flashes.  相似文献   

8.
The lightning activity and precipitation in two 3-hour time intervals in the grid boxes of 0.25 × 0.25° over East and Central Mediterranean during the summer of 2005 and 2006 are analysed. The results show that the frequency distribution of the precipitation amount is shifted towards larger values for the cases with lightning as compared with the cases without lightning. It was found that the number of cases with 3-hour accumulated rainfall greater than 10 mm was bigger when lightning occurred (65%) than when it was absent (35%). Investigation of diurnal and spatial distributions of lightning shows that the afternoon flash density peak is associated mainly with lightning over the land, which is in accordance with the results of earlier works. The early morning flash density peak is associated mainly with flashes over the sea. High correlation coefficients (0.89 during the morning hours and 0.98 during afternoon) were found between rain rate (mm/h) and average flash density (fl/km2) when flash density is averaged in logarithmic intervals of rain rate.  相似文献   

9.
GPS-synchronized measurements of electric (E) field changes induced by lightning flashes were recorded at six stations in the northeastern verge of the Tibetan Plateau. The height and magnitude of charge neutralized by 65 return strokes, including 16 negative cloud-to-ground (CG) flashes and 2 positive CG flashes, have been fitted with the nonlinear least-square method based on the E field changes of CG flashes observed in a typical thunderstorm with larger-than-usual lower positive charge center (LPCC). Results show that the height of the charge region neutralized by negative CG flashes ranges from 3 km to 5 km above the ground, corresponding to an ambient temperature between − 2 °C and − 15 °C. For the two positive CG flashes, the neutralized charge regions are located at a height of about 5.5 km and the ambient temperature is about − 18 °C, indicating the existence of upper positive charge in the thunderstorm.  相似文献   

10.
山东人工引发雷电综合观测实验及回击电流特征   总被引:3,自引:2,他引:1  
山东人工引发雷电实验 (SHATLE) 自2005年开始, 六年来共成功引发负极性雷电22次, 包含大电流回击过程88次, 实验获取了包括雷电放电通道底部电流、近距离电磁场、 高速摄像等在内的高质量同步观测资料。对36次实测回击电流的统计分析表明, 回击峰值电流的几何平均值为12.1 kA, 最大值为41.6 kA, 最小值为4.4 kA。回击电流波形的半峰值宽度范围在1~68 μs之间, 电流10%~90%峰值的上升时间几何平均值为1.9 μs, 中和电荷量为0.86 C, 作用积分(action integral, 或称比能量) 为2.6 ×103A2?s。人工触发闪电峰值电流约16.5 kA的回击在30 m处产生的电场变化可达56.0 kV/m, 60 m处的磁场几何平均值为52 μT。一些强烈的M分量可以具有与回击相当的电流峰值和中和电荷量。人工引雷初始阶段上行正先导的发展速度约为0.96×105 m/s。  相似文献   

11.
In this study we analyze the effects of continuing current initiated by strokes following a new channel to ground in multiple stroke flashes using high-speed video records, electric field measurements from a fast antenna and lightning detection network data. We observed that the long continuing current initiated by a stroke that follows a new channel also obeys the pattern in the initiation of long continuing current suggested by Rakov and Uman [Rakov, V.A., Uman, M.A., 2003. Lightning: Physics and Effects, 687pp., Cambridge Univ. Press, New York.]. We also verify that the statement of Rakov and Uman [Rakov, V.A. and Uman, M.A., 1990. Some properties of negative cloud-to-ground lightning flashes versus stroke order, Journal of Geophysical Research. 95, 5447–5453.] reporting that: “...strokes initiating long continuing currents tend to have lower initial electric field peak than regular strokes” is valid for strokes that create a new channel to ground and are followed by long continuing current (CC). Apparently the reduction of peak current value (Ip) when the stroke is followed by a long CC is stronger than the Ip increase that is commonly observed when strokes follow a new channel. We also find that the “exclusion zone” proposed by Saba et al. [Saba, M.M.F., Pinto, O. Jr., Ballarotti, M.G., 2006a. Relation between lightning return stroke peak current and following continuing current, Geophysical Research Letters 33, L23807, doi:10.1029/2006GL027455.] is valid for new channels initiating CC, and finally we verify that a number of strokes in the same channel larger than four or the existence of a long CC current do not always consolidate the channel in a multiple stroke flash.  相似文献   

12.
The characteristics of cloud-to-ground (CG) lightning for ten hailstorms in Shandong Province of China were analyzed statistically. It is found that the hailstorms in this study present dominant positive CG flashes during periods of falling hail. One specific hailstorm on 16 June 2006 was studied in detail using the data from a CG lightning location network, Doppler radar and cloud images. Comparison between the brightness temperature of cloud-top and CG flash locations indicated that most flashes occurred in the region with temperatures lower than − 40 °C, while dense positive CG flashes occurred in the range between − 40 °C and − 50 °C. Negative CG flashes occurred mostly in the relative weak radar echo region, and positive CG flashes were distributed in the strong echo region especially with a large gradient of echo intensity. CG flashes tended to occur in the cloud region with reflectivity between 25 dBZ and 35 dBZ. Comparison between the wind field retrieved from Doppler radar and the location of CG flashes indicated that the flashes were located in the convergent region at lower to middle levels.  相似文献   

13.
Using high-speed cameras, we have recorded the leaders contained in four natural negative cloud-to-ground (CG) lightning flashes in the summers of 2006 and 2007 at Conghua, Guangdong, China. It was found that the downward negative leaders preceding the first return stroke could propagate at quite different speeds. In one flash, the average speed of the downward negative stepped leader with no branches is about 2.2 × 106 m s− 1, while that of the other 3 flashes are all of the order of 105 m s− 1 with multilevel branches. The luminosity of the leaders shows an increasing tendency in propagating downward to the ground. For the leaders preceding the subsequent strokes, although all of them exhibit high speeds as reported previously. One subsequent leader exhibits an increasing speed from 5.2 × 105 m s− 1 to 1.7 × 106 m s− 1 during its propagation from about 1.26 to 0.36 km above the ground, and its luminosity also increased. The speed and luminosity of a leader between subsequent strokes of a natural lightning appear to decrease as it developed downward. Its speed ranges from 1.1 × 106 to 1.1 × 105 m s− 1, with a height between 1.15 and 0.81 km above the ground.  相似文献   

14.
Using a high-speed camera system and two electric field antenna systems, we have documented the initial processes of an altitude-triggered negative lightning (ATNL). The optical records clearly show that ATNL begins with the inception and propagation of an upward positive leader (UPL) and then a simultaneous propagation of UPL and downward negative leader (DNL), known as the bidirectional leader process, follows. Based on the optical records, it is inferred that (1) the triggering height is about 371 m; (2) the two-dimensional (2D) propagation speed of the UPL in its inception phase is about 3.8–5.5 × 104 m s− 1 during its propagation from about 393 to 452 m above the ground; (3) the grey levels of the DNL are about one order of magnitude higher than that of the UPL in their inception phase; (4) a discharge phenomenon propagating along the elevated triggering wire part of the lightning channel occurs after the mini-return stroke (MRS), with a 2D propagation speed of about 1.6–2.0 × 105 m s− 1. Combined with the simultaneous electric field change records, it is further inferred that (1) the UPL incepts about 932 μs earlier than the unstable DNL and about 4.1 ms earlier than the stable DNL; (2) the unstable DNL propagates downward intermittently three times with a time interval of about 1 ms, and each propagation contains a different number of steps with an average step length of about 7 m; (3) the stable DNL incepts at the tip of the unstable one, with a 2D propagation speed of about 1.9 × 105 m s− 1, an average step length of about 3 m, and a stepping time interval varying from 6 to 31 µs with a mean value of 15 µs.  相似文献   

15.
广州高建筑物雷电观测站光电同步观测系统于2017年6月16日记录到一次峰值电流达+141 kA的单回击正地闪触发两个并发上行闪电过程。利用高速摄像、普通摄像和电场变化数据分析了触发型上行闪电的始发特征和机理。结果表明:正地闪回击后约0.8 ms内,在距正地闪接地点约3.9 km的广州塔(高600 m)和4.1 km的东塔(高530 m)分别有上行闪电始发。正地闪回击过程中和大量正电荷以及之后可能有云内负先导朝高塔方向快速伸展造成塔顶局部区域的电场发生突变是两个上行闪电激发的原因。两个上行闪电在353 ms内发生7次回击,其中6次在广州塔上,仅1次在东塔上,且广州塔回击峰值电流平均值(-21.4 kA)约为东塔回击峰值电流(-7.3 kA)的3倍,表明广州塔上行闪电通道可能比东塔上行闪电通道伸展至分布范围更广、电荷量(或电荷密度)更大的负电荷区。两个上行闪电先导的二维速率变化范围为9.4×104~1.8×106 m·s-1,平均值为6.9×105 m·s-1。  相似文献   

16.
利用2007—2018年浙江省ADTD闪电定位资料,分析了该地区多回击地闪分布及相关参数特征。结果表明:浙江省多回击地闪占总地闪的26.74%,其中正闪以单回击地闪为主;正、负闪平均回击数分别为1.04次和1.65次,最大回击数分别为5次和21次。回击数和地闪数存在较为一致的年际变化,正、负多回击地闪日变化分别呈多峰和单峰分布。正、负多回击地闪电流强度算术平均值分别为72.06kA和-36.89kA,回击平均强度随回击数的增加而下降,约40%的地闪过程中至少有1次继后回击强度比首次回击强;首次回击和继后回击的强度分布呈对数正态分布,集中在15~45kA之间。正、负地闪回击间隔时间算术平均值分别为125.47ms和138.14ms,几何平均值分别为56.73ms和98.95ms,回击间隔时间呈对数正态分布,平均回击间隔时间随回击数的增大而减小。多回击地闪继后回击与首次回击之间距离与回击数呈准正态分布,集中在距离为1km范围内。  相似文献   

17.
为进一步研究多回击地闪参数分布特征, 以便为雷电防护工程设计和雷电物理研究提供参考, 根据湖北省雷电定位系统(LLS)2007年1月—2018年12月监测资料, 采用计算机编程处理和数理统计方法, 对多回击地闪次数、多重回击次数和不同类型多回击地闪雷电流幅值等参数进行了统计分析。结果表明: 多回击正地闪、负地闪和总地闪次数占其地闪总数的百分比分别为2.06%、34.76%和32.64%, 多重回击次数分别占其回击总数的0.01%、0.42%和0.40%, 多回击负地闪回击次数占多回击总地闪回击总数的99.69%。首次回击强度大于后续回击强度的多回击正地闪和负地闪分别占多回击地闪总数的82.52%和57.87%;在多回击地闪后续回击中, 正地闪约有9%的后续回击强度大于首次回击强度, 负地闪约有20%的后续回击强度大于首次回击强度。多回击正地闪和负地闪中值电流分别为59.30 kA和35.10 kA, 首次回击分别为90.90 kA和40.00 kA, 后续回击中分别为43.90 kA和33.00 kA。首次回击中, 多回击正地闪和负地闪雷电流幅值大于100 kA的累积概率分别为44.06%和4.64%, 首次回击强度大于后续回击强度的多回击正地闪和负地闪雷电流幅值大于100 kA的累积概率最大分别为52.21%和7.94%;后续回击中, 多回击正地闪和负地闪雷电流幅值小于等于40 kA的累积概率分别为41.80%和69.92%, 首次回击强度大于后续回击强度的多回击负地闪, 雷电流幅值小于等于40 kA的累积概率最大为77.71%。多回击正地闪和负地闪后续回击与首次回击中值电流的比值分别为0.48和0.83。拟合得出的不同类型的多回击正地闪和负地闪雷电流幅值累积概率公式, 拟合效果显著; 拟合公式中a值附近的雷电流幅值累积概率与b值呈显著正相关关系。   相似文献   

18.
根据2007—2019年地闪监测资料,采用数理统计方法,分析湖北省闪电活动时空分布特征,融合地闪密度和雷电流强度,提出雷电强度的概念,并完成湖北省雷电强度等级划分。结果表明:湖北省以负极性闪电为主,占94.7%,平均正地闪强度为50.2 kA、负闪36.0 kA、总闪37.0 kA。闪电活动主要集中在全年的3—9月、全天的14—20时,闪电活动较弱的月份、时段发生正地闪的比例较高。正地闪强度月变化大致呈“V”型,总闪电和负地闪强度逐月波动变化。雷电流强度日变化主要呈单峰单谷型,正地闪强度09时最大,15时最小,总闪电和负地闪13—14时雷电流强度最小,05时最大。地闪密度和雷电流强度存在地域性差异,整体呈东高西低分布特征。湖北省雷电强度可划分为高、中、低3个等级,高值区主要位于湖北东部的大别山、幕阜山与江汉平原交汇地带以及湖北西部山区向江汉平原的过渡地带;湖北西南、湖北西北以及湖北个别边缘区域雷电强度等级较低;中值区主要分布在湖北中部平原一带。  相似文献   

19.
一次“晴天霹雳”致死事件分析   总被引:1,自引:0,他引:1  
对2017年广州从化地区一次"晴朗"天气下的闪电致死事件进行调查分析发现,这次事件是闪电首先击中一棵大树,然后击中附近人员头顶致死。根据目击者描述的时间和位置,利用闪电低频电场变化探测阵列的定位数据和广东电力等系统的雷电定位数据,结合广州番禺雷达观测资料,确定此事件是由一次含有7次回击的地闪过程的首次回击造成,其电流峰值强度为-30.9 kA。闪电起始于13.0 km高度的云内,经约600 ms云内发展过程后闪电通道从云体延伸出来,云砧区边缘(0 dBz)到回击点水平距离约300 m,降水区边缘(18 dBz)到回击点水平距离约1.8 km。使用雷击现场等效电路模型,计算旁络闪击空气击穿场强可击穿空气与人头部连接为通路,根据电路分流原理,如果雷电流击中13 m高的大树后流经到"跳点"(树干上方1/4)处后,则有13.2 kA雷电流直接闪击到受害者身上,同时还承受了78.3 kV跨步电压伤害,而距离雷击点10 m远的目击者仅承受1.3 kV跨步电压。   相似文献   

20.
在广州野外雷电试验基地,对2008年和2011年夏季人工触发闪电回击之后的14个连续电流过程和43个M分量的通道底部电流、电场变化和通道亮度进行了同步测量和分析。结果表明:M分量的电流、快慢电场变化和亮度变化波形均近似对称;触发闪电连续电流过程的持续时间、转移电荷量、电流平均值的几何平均值分别为22 ms,6.0 C和273 A;M分量的幅度、转移电荷量、半峰值宽度、上升时间、持续时间的几何平均值分别为409 A,205 mC,520 μs,305 μs和1.6 ms;连续电流持续时间与M分量的个数、相邻M分量之间的时间间隔均存在显著的正相关关系。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号