首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Singapore is a classic case of a modern metropolis with low hazard but high exposure to the seismicity in Sumatra. Because of land shortage, more than 80% of the population lives in high‐rise residential buildings. As part of the efforts to assess the seismic performance of buildings in Singapore subjected to long‐distance Sumatran earthquakes, relationships between the natural vibration period and height of high‐rise public residential buildings in Singapore are derived empirically by conducting ambient vibration tests on 116 buildings. The measured buildings have a height ranging from 4 to 30 stories. The aspect ratio of buildings in plan is found to be insignificant in affecting the natural vibration period of the first mode of the buildings. The period‐height relationships are derived using regression analysis considering the site properties of a building. It is concluded that the vibration periods estimated from the proposed period‐height relationship for buildings located at soft‐soil site are about 40% longer than the vibration periods estimated for buildings located at firm‐soil site. Measurements are also conducted to study the influence of buildings on the measured frequency of the surrounding soil. For this purpose, two buildings with 25 and 30 stories located at firm‐soil site and soft‐soil site, respectively, are selected. It is found that the distance of building influence on the measured frequency of the surrounding soil may reach up to one building height for a firm‐soil site and two building heights for a soft‐soil site. Additional data of natural vibration periods of 19 instrumented residential buildings, which have height ranging from 9 to 30 stories, were obtained from the building response recorded during the September 30, 2009 Sumatran earthquake event. The natural vibration periods of these buildings are compared with those estimated using the proposed period‐height relationships, and the absolute differences are found to be less than 12%. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
Singapore and Kuala Lumpur, the capital of Malaysia, may well represent the classic examples of area with low seismic hazard but with high consequence. Both cities are located in a low-seismicity region of Southeast Asia, where active seismic sources are located more than 300 km away. Seismic designs have not been implemented in this seemingly low-hazard region though distant earthquakes in Sumatra had frequently shaken high-rise structures in the two cities. Several studies have been conducted to systematically assess the seismic hazards of Singapore and the Malay Peninsula. The present research particularly addresses issues in deriving a new set of attenuation relationships of peak ground acceleration (PGA), peak ground velocity (PGV) and response spectral acceleration (RSA) for the Sumatran-subduction earthquakes. To be relevant for the seismic hazard assessment of the remote metropolises, the derived attenuation relationships cover a long distance range from 150 to 1500 km. The attenuation relationships are derived using synthetic seismograms that account for source and path effects. The uncertainties in rupture parameters, such as stress drop, strike, dip and rake angles, have been defined according to the regional geological and tectonic settings as well as the ruptures of previous earthquakes. The seismic potential of the Sumatran subduction zone are high in the region from 2°N to 5°S as there has been no recurrence of great thrust events since 1861. A large event with Mw greater than 7.8 in this particular subduction zone may be capable of generating destructive ground motions in Singapore and Kuala Lumpur, even at a distance of 700 km.  相似文献   

3.
This paper presents selected indicative results from an extensive parametric investigation that has been performed in order to assess the effects of potential earthquake‐induced poundings on the overall dynamic response of seismically isolated buildings. In particular, a seismically isolated building and its adjacent fixed‐supported buildings are subjected to various earthquake excitations that induce structural impact among the buildings in series. The results indicate that the seismically isolated building may hit against the adjacent buildings at the upper floor levels before the occurrence of any pounding at the isolation level with the surrounding moat wall. The severity of the impact depends on the dynamic properties of the adjacent buildings, in combination with the earthquake characteristics. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
苏门答腊岛8.7级地震对我国南北地震带地震形势的影响   总被引:3,自引:0,他引:3  
分析了苏门答腊8.7级地震对我国南北地震带尤其是川滇地震活动和前兆观测的巨大影响,以及历史上从印度安达曼到印度尼西亚苏门答腊区域的巨大地震与中国大陆西部尤其是南北地震带强震的关系。结果表明:这次苏门答腊8.7级地震对南北地震带地震活动和前兆观测的影响巨大;历史上安达曼—苏门答腊区域的巨大地震与中国大陆西部尤其是南北地震带强震存在较短时间尺度的呼应相关。  相似文献   

5.
We apply a combination of earthquake early warning system (EEWS) and real-time strong motion monitoring system (RSMS) to emergency response for a high-rise building; The Kogakuin University has a 29-story high-rise building in Shinjuku Ward, Tokyo. The proposed strategy is based on the Plan, Do, Check, Action (PDCA) Cycle to brush up the systems and the users: in the “Plan” stage, we apply EEWS and RSMS to the building, where EEWS predicts not only short-period strong ground motions but also long-period ground motions [1]. The system is built into a building announcement system, an emergency elevator control system, and an email message system, which quickly send emails to the emergency response team. Meanwhile, RSMS provides information on seismic intensities at each floor of the building via the web browser in real time using the existing network in the building. In addition, the building response and structural damage can be estimated based on this information. The network system is impervious to the earthquake damage, because the network cable has extra length, there is, however, possible that a network system does not work due to power outage. Thus, we develop the network system that has uninterruptible power-supply system (UPS) and apply it to EEWS and RSMS. The high-rise building has the emergency call units to the security control center in the building on every floor. The emergency call line, however, will be busy promptly, because it is able to use only one line. Therefore, we installed IP telephone which uses the network system on main floors. UPS will work about 30 min after a major earthquake, it is supposed to be enough time for gathering the damage information about the building during initial response. In the “Do” stage, we prepare emergency response instruction manuals and educate the faculty members and students to carry out promptly emergency response. In the “Check” stage, the validity of the proposed systems are verified by carrying out an earthquake drill in an actual high-rise building. The earthquake drill confirmed that our proposed approach is valid. In the final “Action” stage, we improve these systems and emergency response manual and educate people in the building how to use effectively these systems.  相似文献   

6.
This study proposes a procedure for identifying spectral response curves for earthquake‐damaged areas in developing countries without seismic records. An earthquake‐damaged reinforced concrete building located in Padang, Indonesia was selected to illustrate the identification of the maximum seismic response during the 2009 West Sumatra earthquake. This paper summarizes the damage incurred by the building; the majority of the damage was observed in the third story in the span direction. The damage was quantitatively evaluated using the damage index R according to the Japanese guidelines for post‐earthquake damage evaluation. The damage index was also applied to the proposed spectral response identification method. The seismic performance of the building was evaluated by a nonlinear static analysis. The analytical results reproduced a drift concentration in the third story. The R‐index decreased with an increase in the story drift, which provided an estimation of the maximum response of the building during the earthquake. The estimation was verified via an earthquake response analysis of the building using ground acceleration data, which were simulated based on acceleration records of engineering bedrock that considered site amplification. The maximum response estimated by the R‐index was consistent with the maximum response obtained from the earthquake response analysis. Therefore, the proposed method enables the construction of spectral response curves by integrating the identification results for the maximum responses in a number of earthquake‐damaged buildings despite a lack of seismic records. Copyright © 2016 The Authors. Earthquake Engineering & Structural Dynamics published by John Wiley & Sons Ltd.  相似文献   

7.
This paper presents experimental and numerical studies of a full‐scale deformable connection used to connect the floor system of the flexible gravity load resisting system to the stiff lateral force resisting system (LFRS) of an earthquake‐resistant building. The purpose of the deformable connection is to limit the earthquake‐induced horizontal inertia force transferred from the floor system to the LFRS and, thereby, to reduce the horizontal floor accelerations and the forces in the LFRS. The deformable connection that was studied consists of a buckling‐restrained brace (BRB) and steel‐reinforced laminated low‐damping rubber bearings (RB). The test results show that the force–deformation responses of the connection are stable, and the dynamic force responses are larger than the quasi‐static force responses. The BRB+RB force–deformation response depends mainly on the BRB response. A detailed discussion of the BRB experimental force–deformation response is presented. The experimental results show that the maximum plastic deformation range controls the isotropic hardening of the BRB. The hardened BRB force–deformation responses are used to calculate the overstrength adjustment factors. Details and limitations of a validated, accurate model for the connection force–deformation response are presented. Numerical simulation results for a 12‐story reinforced concrete wall building with deformable connections show the effects of including the RB in the deformable connection and the effect of modeling the BRB isotropic hardening on the building seismic response. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

8.
带SRC桁架转换层及钢加强层高层建筑抗震性能研究   总被引:6,自引:2,他引:4  
本文对一座设置钢骨混凝土桁架转换层及两道钢桁架加强层的超高层建筑结构模型振动台试验结果进行了分析,发现Ⅶ度小震和中震阶段在下部转换层和中部加强层加速度突变较大,而上部加强层突变较小:在Ⅶ度大震阶段由于转换层及其附近楼层裂缝的出现,地震能量转嫁到中部加强层,致使中部加强层加速度突变出现大幅度的增长,该层及附近楼层核心筒墙肢出现一定程度的破坏。采用SAP2000有限元程序对该结构模型进行了小震阶段三维分析,并与试验值进行了对比:从动力特性来看,前几阶周期比较吻合,高阶周期误差较大;从动力反应来看,侧移曲线、加速度包络图、地震作用包络图在整体上符合较好,但在中部加强层和转换层处突变幅度计算值偏小;从层间剪力包络图来看,试验值与有限元计算值都呈现近似直线分布。  相似文献   

9.
A 54‐story steel, perimeter‐frame building in downtown Los Angeles, California, is identified by a wave method using records of the Northridge earthquake of 1994 (ML = 6.4, R = 32 km). The building is represented as a layered shear beam and a torsional shaft, characterized by the corresponding velocities of vertically propagating waves through the structure. The previously introduced waveform inversion algorithm is applied, which fits in the least squares sense pulses in low‐pass filtered impulse response functions computed at different stories. This paper demonstrates that layered shear beam and torsional shaft models are valid for this building, within bands that include the first five modes of vibration for each of the North–South (NS), East–West (EW), and torsional responses (0–1.7 Hz for NS and EW, and 0–3.5 Hz for the torsional response). The observed pulse travel time from ground floor to penthouse level is τ ≈1.5 s for NS and EW and τ ≈ 0.9 s for the torsional responses. The identified equivalent uniform shear beam wave velocities are βeq ≈ 140 m/s for NS and EW responses, and 260 m/s for torsion, and the apparent Q ≈ 25 for the NS and torsional, and ≈14 for the EW response. Across the layers, the wave velocity varied 90–170 m/s for the NS, 80–180 m/s for the EW, and 170–350 m/s for the torsional responses. The identification method is intended for use in structural health monitoring. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
This paper presents an experimental study to explore the possibility of using a hybrid platform to ensure the functionality of high‐tech equipment against microvibration and to protect high‐tech equipment from damage when an earthquake occurs. A three‐storey building model and a hybrid platform model were designed and manufactured. The two‐layer hybrid platform, on which the high‐tech equipment is placed, was installed on the first floor of the building to work as a passive platform aiming at abating acceleration response of the equipment during an earthquake and functioning as an actively controlled platform that intends to reduce velocity response of the equipment under a normal working condition. For the hybrid platform working as a passive platform, it was designed in such a way that its stiffness and damping ratio could be changed, whereas for the hybrid platform functioning as an active platform, a piezoelectric actuator with a sub‐optimal velocity feedback control algorithm was used. A series of shaking table tests, traffic‐induced vibration tests and impact tests were performed on the building with and without the platform to examine the performance of the hybrid platform. The experimental results demonstrate that the hybrid platform is feasible and effective for high‐tech equipment protection against earthquake and microvibration. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

11.
In this paper, a field experiment was carried out to study train-induced environmental vibrations. During the field experiment, velocity responses were measured at different locations of a six-story masonry structure near the Beijing-Guangzhou Railway and along a small road adjacent to the building. The results show that the velocity response levels of the environmental ground and the building floors increase with train speed, and attenuate with the distance to the railway track. Heavier freight trains indu...  相似文献   

12.
本溪井对应地震的水位响应可分为震前响应(水位异常)和震时、震后响应(震后效应)两种。自1999年以来,本溪井多次记录到了对应典型地震较为明显的水位响应变化,最远为2004年12月26日印尼苏门答腊MS8.7地震,震中距为4990km,一般来讲,地震的震级越大,震中距越小,本溪井水位响应幅度越大。  相似文献   

13.
Recently,effects of Earth's curvature and radial heterogeneity on coseismic deformations are often investigated based on the 2004 Sumatra earthquake.However,such effects are strongly related to earthquake types.As a low dip angle event,the 2004 Sumatra earthquake is not a good seismic case for such a topic since the effects for moderate dip angle events are much bigger.In this study,the half-space and spherical dislocation theories are used,respectively,to calculate coseismic displacements caused by the 2008 Wenchuan earthquake and the 2004 Sumatra earthquake.Effects of Earth's curvature and stratification are investigated through the discrepancies of results calculated using the two dislocation theories.Results show that the effects of Earth's curvature and stratification for the 2008 Wenchuan earthquake are much larger than those for the 2004 Sumatra earthquake.Ignoring the effects will cause errors up to 100%-200% in far field displacements for a moderate dip angle event like the 2008 Wenchuan earthquake.Such great effects are much bigger than those conclusions of previous studies.Besides,comparison with observations verifies that spherical dislocation theories yield better results than half-space ones in far fields.  相似文献   

14.
苏门答腊--蒙古(1935~1957)地震大迁移的回顾   总被引:1,自引:0,他引:1  
为了分析2004年12月26日苏门答腊Ms8.9大地震对大陆地震形势的影响,本文介绍了1935~1957年苏门答腊-蒙古地震大迁移事件,时间持续22年,长度4600km,迁移速度205km/a。迁移以1935年12月28日苏门答腊Ms7.7地震为起点,从印度-澳大利亚板块与欧亚板块南部边界俯冲事件开始,向北经安达曼海沟到达缅甸弧和喜马拉雅弧东端后,进入中国大陆,沿着中蒙大陆中轴地震带直抵蒙古。  相似文献   

15.
强地震前后重力观测中异常变化现象的研究   总被引:3,自引:0,他引:3  
王武星  马丽  黄建平 《地震》2007,27(2):53-63
分析了2001年昆仑山口西MS8.1地震和2004年印尼MS8.9地震前后部分重力观测的变化, 对这些采样间隔在1分钟以下的重力数据进行了高通滤波和频谱分析。 结果表明, 在昆仑山口西MS8.1地震前, 乌鲁木齐和库尔勒观测台在二个时段分别同步出现了异常变化。 一次是在2001年11月3~5日, 另一次在2001年11月11~13日; 这二次异常都表现为颤动信号的出现, 而且后一次的强度要大于前一次; 颤动信号的周期主要集中在几十分钟。 印尼MS8.9地震前, 这二个台也记录到类似的异常信息, 但颤动的幅度很小; 同时武汉观测台的超导重力仪也记录到了颤动信号, 该信号一直持续到地震的发生。 这些信息对于识别、 认识慢地震, 进而探索与强地震发生之间的关系具有重要意义。  相似文献   

16.
Numerical simulations and parametric studies have been used to investigate the influence of potential poundings of seismically isolated buildings with adjacent structures on the effectiveness of seismic isolation. Poundings are assumed to occur at the isolation level between the seismically isolated building and the surrounding moat wall. After assessing some common force‐based impact models, a variation of the linear viscoelastic impact model is proposed to avoid tensile impact forces during detachment, while enabling the consideration of permanent plastic deformations at the vicinity of the impact. A large number of numerical simulations of seismically isolated buildings with different characteristics have been conducted under six earthquake excitations in order to investigate the influence of various design parameters and conditions on the peak floor accelerations and interstorey deflections during poundings. The numerical simulations demonstrate that poundings may substantially increase floor accelerations, especially t the base floor where impacts occur. Higher modes of vibration are excided during poundings, increasing the interstorey deflections, instead of retaining an almost rigid‐body motion of the superstructure, which is aimed with seismic isolation. Impact stiffness seems to affect significantly the acceleration response at the isolation level, while the displacement response is more insensitive to the variation of the impact stiffness. Finally, the results indicate that providing excessive flexibility at the isolation system to minimize the floor accelerations may lead to a building vulnerable to poundings, if the available seismic gap is limited. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

17.
An effective procedure is summarized without derivation for estimating the maximum response of a class of torsionally-coupled, multi-storey buildings due to earthquake ground motion characterized by response spectra. The analysis procedure is shown to be efficient and to provide insight into torsional coupling effects because the maximum response of such a torsionally-coupled, N-storey building in its njth mode of vibration is determined exactly by analysing (i) the response in the jth vibration mode (j = 1,2, N) of the corresponding torsionally-uncoupled, N-storey system; and (ii) the response in the nth vibration mode (n = 1, 2 for a one-way symmetric plan) of an associated torsionally-coupled, one-storey system. It is also demonstrated that an earlier, simpler approach in which the total (considering all vibration modes) response of the building is determined from the total response of the two simpler systems is strictly valid only under restrictive conditions, which are identified, but the simpler approach leads to results that are accurate to a useful degree.  相似文献   

18.
杨建华  叶郁 《地震工程学报》2019,41(5):1141-1146,1176
为实现多层砖房底部两层框架结构的加固,需要研究其抗震变形性能。以某底部两层框架、上部四层砖房建筑为对象,通过STRAND7有限元软件构建有限元计算模型,考虑水平荷载与垂直荷载,深入分析多层砖房底部两层框架抗震变形性能。仿真结果表明,建筑结构振型受结构横向楼板刚度的影响较显著,不同振型的频率变化中,X向1阶频率与Y向2阶频率变化最快,楼板平面内弯曲频率变化最慢;整体结构在X向与Y向分别呈现线性剪切变形和弯剪变形,Y向上由于填充墙发挥抗震墙功能,底部两层框架变形较小;在7度多遇地震影响下,底部两层结构中第二层楼板变形较第一层严重,多层砖房底部两层框架建筑结构处于弹性工作状态。  相似文献   

19.
A study has been made of the response, during the San Fernando earthquake 9 February 1971, of the nine-storey steel frame Building 180, located at the California Institute of Technology, Jet Propulsion Laboratory, Pasadena. The analysis throws light on the actual dynamical properties of the building during the earthquake, and also demonstrates that it is possible, when the ground motion is specified, to make accurate predictions of building motions during moderate earthquakes by using a linear viscously damped model. Methods of evaluating the lower mode periods and damping ratios from the earthquake records are described and the values obtained are compared with results from dynamic testing before and after the earthquake and with the periods computed from computer models of the building. Although no structural damage occurred and computed stresses in the steel frame were less than yield stresses, the periods measured by an ambient vibration test after the earthquake were of the order of 10 per cent higher than the pre-earthquake values. The maximum periods during the earthquake were found to be about 30 per cent higher than the post-earthquake periods.  相似文献   

20.
Although Singapore is located in a low‐seismicity region, huge but infrequent Sumatran subduction earthquakes might pose structural problems to medium‐ and high‐rise buildings in the city. Based on a series of ground motion simulations of potential earthquakes that may affect Singapore, the 1833 Sumatran subduction earthquake (Mw=9.0) has been identified to be the worst‐case scenario earthquake. Bedrock motions in Singapore due to the hypothesized earthquake are simulated using an extended reflectivity method, taking into account uncertainties in source rupture process. Random rupture models, considering the uncertainties in rupture directivity, slip distribution, presence of asperities, rupture velocity and dislocation rise time, are made based on a range of seismologically possible models. The simulated bedrock motions have a very long duration of about 250 s with a predominant period between 1.8 and 2.5 s, which coincides with the natural periods of medium‐ and high‐rise buildings widely found in Singapore. The 90‐percentile horizontal peak ground acceleration is estimated to be 33 gal and the 90‐percentile horizontal spectral acceleration with 5% damping ratio is 100 gal within the predominant period range. The 90‐percentile bedrock motion would generate base shear force higher than that required by the current design code, where seismic design has yet to be considered. This has not taken into account effects of local soil response that might further amplify the bedrock motion. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   