首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The seismic response analysis of a base-isolated liquid storage tank on a half-space was examined using a coupling method that combines the finite elements and boundary elements. The coupled dynamic system that considers the base isolation system and soil–structure interaction effect is formulated in time domain to evaluate accurately the seismic response of a liquid storage tank. Finite elements for a structure and boundary elements for liquid are coupled using equilibrium and compatibility conditions. The base isolation system is modeled using the biaxial hysteretic element. The homogeneous half-space is idealized using the simple spring-dashpot model with frequency-independent coefficients. Some numerical examples are presented to demonstrate accuracy and applicability of the developed method.Consequently, a general numerical algorithm that can analyze the dynamic response of base-isolated liquid storage tanks on homogeneous half-space is developed in three-dimensional coordinates and dynamic response analysis is performed in time domain.  相似文献   

2.
A study of soil–structure–fluid interaction (SSFI) of a lock system subjected to harmonic seismic excitation is presented. The water contained lock is embedded in layered soils supported by a half-space bedrock. The ground excitation is prescribed at the soil–bedrock interface. The response is numerically obtained through a hybrid boundary element (BEM) finite element method (FEM) formulation. The semi-infinite soil and the fluid are modeled by the BEM and the lock is modeled by the FEM. The equilibrium equation for the lock system is obtained by enforcing compatibility and equilibrium conditions at the fluid–structure, soil–structure and soil–layer interfaces under conditions of plane strain. To the authors’ knowledge this is the first study of a lock system that considers the effects of dynamic soil–fluid–structure interaction through a BEM–FEM methodology. A numerical example and parametric studies are presented to examine the effects of the presence of water, lock stiffness, and lock embedment on the response.  相似文献   

3.
A common effective method to reduce the seismic response of liquid storage tanks is to isolate them at base using base-isolation systems. It has been observed that in many earthquakes, the foregoing systems significantly affect on the whole system response reduction. However, in exceptional cases of excitation by long-period shaking, the base-isolation systems could have adverse effects. Such earthquakes could cause tank damage due to excessive liquid sloshing. Therefore, the numerical seismic response of liquid storage tanks isolated by bilinear hysteretic bearing elements is investigated under long-period ground motions in this research. For this purpose, finite shell elements for the tank structure and boundary elements for the liquid region are employed. Subsequently, fluid–structure equations of motion are coupled with governing equation of base-isolation system, to represent the whole system behavior. The governing equations of motion of the whole system are solved by an iterative and step-by-step algorithm to evaluate the response of the whole system to the horizontal component of three ground motions. The variations of seismic shear forces, liquid sloshing heights, and tank wall radial displacements are plotted under various system parameters such as the tank geometry aspect ratio (height to radius), and the flexibility of the isolation system, to critically examine the effects of various system parameters on the effectiveness of the base-isolation systems against long-period ground motions. From these analyses, it may be concluded that with the installation of this type of base-isolation system in liquid tanks, the dynamic response of tanks during seismic ground motions can be considerably reduced. Moreover, in the special case of long-period ground motions, the seismic response of base-isolated tanks may be controlled by the isolation system only at particular conditions of slender and broad tanks. For the case of medium tanks, remarkable attentions would be required to be devoted to the design of base-isolation systems expected to experience long-period ground motions.  相似文献   

4.
A study on the seismic response of massive flexible strip-foundations embedded in layered soils and subjected to seismic excitation is presented. Emphasis is placed on the investigation of the system response with the aid of a boundary element–finite element formulation proper for the treatment of such soil–structure interaction problems. In the formulation, the boundary element method (BEM) is employed to overcome the difficulties that arise from modeling the infinite soil domain, and the finite element method (FEM) is applied to model the embedded massive flexible strip-foundation. The numerical solution for the soil–foundation system is obtained by coupling the FEM with the BEM through compatibility and equilibrium conditions at the soil–foundation and soil layer interfaces. A parametric study is conducted to investigate the effects of foundation stiffness and embedment on the seismic response.  相似文献   

5.
This paper investigates the effects of foundation embedment on the seismic behavior of fluid-elevated tank-foundation–soil system with a structural frame supporting the fluid containing tank. Six different soil types defined in the well-known seismic codes were considered. Both the sloshing effects of the fluid and soil-structure interaction of the elevated tanks located on these six different soils were included in the analyses. Fluid-elevated tank-foundation–soil systems were modeled with the finite element (FE) technique. The fluid-structure interaction was taken into account using Lagrangian fluid FE approximation implemented in the general purpose structural analysis computer program, ANSYS. FE model with viscous boundary was used to include elevated tank-foundation–soil interaction effects. The models were analyzed for the foundations with and without embedment. It was found that the tank roof displacements were affected significantly by the embedment in soft soil, however, this effect was smaller for stiff soil types. Except for soft soil types, embedment did not affect the other response parameters, such as sloshing displacement, of the systems considered in this study.  相似文献   

6.
In this paper, a study on the transient response of an elastic structure embedded in a homogeneous, isotropic and linearly elastic half-plane is presented. Transient dynamic and seismic forces are considered in the analysis. The numerical method employed is the coupled Finite-Element–Boundary-Element technique (FE–BE). The finite element method (FEM) is used for discretization of the near field and the boundary element method (BEM) is employed to model the semi-infinite far field. These two methods are coupled through equilibrium and compatibility conditions at the soil–structure interface. Effects of non-zero initial conditions due to the pre-dynamic loads and/or self-weight of the structure are included in the transient boundary element formulation. Hence, it is possible to analyse practical cases (such as dam–foundation systems) involving initial conditions due to the pre-seismic loads such as water pressure and self-weight of the dam. As an application of the proposed formulation, a gravity dam has been analysed and the results for different foundation stiffness are presented. The results of the analysis indicate the importance of including the foundation stiffness and thus the dam–foundation interaction.  相似文献   

7.
An approach is formulated for the linear analysis of three-dimensional dynamic soil–structure interaction of asymmetric buildings in the time domain, in order to evaluate the seismic response behaviour of torsionally coupled buildings. The asymmetric building is idealized as a single-storey three-dimensional system resting on different soil conditions. The soil beneath the superstructure is modeled as linear elastic solid elements. The contact surface between foundation mat and solid elements of soil is discretised by linear plane interface elements with zero thickness. An interface element is further developed to function between the rigid foundation and soil. As an example, the response of soil–structure interaction of torsionally coupled system under two simultaneous lateral components of El Centro 1940 earthquake records has been evaluated and the effects of base flexibility on the response behaviour of the system are verified.  相似文献   

8.
The 1995 Hyogo-ken Nanbu (Kobe) earthquake brought about enormous damage to structures in the Hanshin and Awaji areas. In this paper the importance of investigating the relationship between ground motion and structural damage is pointed out.

Strong seismic motion was observed at the NTT (Nippon Telegraph and Telephone) Building during this earthquake. The structural damage to this building was relatively slight. In order to evaluate the relationship between ground motion and structural damage, it is necessary to assess the effects of the soil–structure interaction. In this study, the seismic response of the building and of the surface soil were evaluated by means of a nonlinear soil–structure interaction analysis using FEM.

It was found that, the nonlinearity of surface soil near the building had a great effect on the soil–structure interaction, especially the rocking of the building.  相似文献   


9.
A large reinforced concrete structure supported on piles extending to bedrock is evaluated using a seismic soil–structure interaction analysis. The physical structure, the supporting pile system, analysis model and analytical methodology used are described. Important considerations in the design of the foundation pile system using the seismic analysis loadings and deformations are discussed.  相似文献   

10.
This paper gives a brief presentation of the study on foundation of a residential business complex. The unfavourable geotechnical conditions of the site considered led to the need to improve the natural foundation soil. The most favourable and rational solution for providing safety and stability of structures was the combination of gravel and a sub-base. Computations were done as follows: analysis of the stress–strain state by using the parameters of the natural non-improved soil and analyses performed by using the parameters of the improved soil. The results from these analyses were used for analysis of the integral soil–structure system. Hence, complete information on the possibility for optimisation of the foundation structure was obtained.  相似文献   

11.
This paper proposes a dynamic centrifuge model test method for the accurate simulation of the behaviours of a liquid storage tank with different types of foundations during earthquakes. The method can be used to determine the actual stress conditions of a prototype storage‐tank structure. It was used in the present study to investigate the soil‐foundation‐structure interactions of a simplified storage tank under two different earthquake motions, which were simulated using a shaking table installed in a centrifuge basket. Three different types of foundations were considered, namely, a shallow foundation, a slab on the surface of the ground connected to piles and a slab with disconnected piles. The test results were organised to compare the ground surface and foundation motions, the slab of foundation and top of structure motions and the horizontal and vertical motions of the slab, respectively. These were used to establish the complex dynamic behaviours of tank models with different foundations. The effects of soil–foundation–structure interaction with three foundation conditions and two different earthquake motions are focused and some important factors, that should be considered for future designs are also discussed in this research. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

12.
A variationally coupled BEM–FEM is developed which can be used to analyse dynamic response, including free-surface sloshing motion, of 3-D rectangular liquid storage tanks subjected to horizontal ground excitation. The tank structure is modelled by the finite element method and the fluid region by the indirect boundary element method. By minimizing a single Lagrange function defined for the entire system, the governing equation with symmetric coefficient matrices is obtained. To verify the newly developed method, the analysis results are compared with the shaking-table test data of a 3-D rectangular tank model and with the solutions by the direct BEM–FEM. Analytical studies are conducted on the dynamic behaviour of 3-D rectangular tanks using the method developed. In particular, the characteristics of the sloshing response, the effect of the rigidity of adjacent walls on the dynamic response of the tanks and the orthogonal effects are investigated. © 1998 John Wiley & Sons, Ltd.  相似文献   

13.
A general, rigorous, coupled Boundary Element–Finite Element (BE–FE) formulation is presented for non-linear seismic soil–structure interaction in two dimensions. The BE–FE method is applied to investigate the inelastic response of earth dams to transient SV waves. The dam body, consisting of heterogeneous materials modelled with a simple non-linear hysteretic model, is discretized with finite elements, whereas the elastic half-space is discretized with boundary elements. The study focuses on the combined effects of the material non-linearity and foundation flexibility. The results show the significant effect of the foundation flexibility in reducing the response through radiation of energy. For excitations with peak ground accelerations from 0·2gto 0·6g, the crest acceleration amplification ranges from 2·5 to 1·4 and seems to be comparable with field observations and results from other studies. Deamplification increasing with strain is reported at the lower part of the dam. The method is computationally powerful and can be used for efficient non-linear analysis of complex soil–structure systems. The efficiency of the BE–FE method allows further improvements with incorporation of a more advanced constitutive model and consideration of the generation and dissipation of pore-water pressures during the earthquake. © 1998 John Wiley & Sons, Ltd.  相似文献   

14.
Current practice usually pays little attention to the effect of soil–structure interaction (SSI) on seismic analysis and design of bridges. The objective of this research study is to assess the significance of SSI on the modal with geometric stiffness and seismic response of a bridge with integral abutments that has been constructed using a new bridge system technology. Emphasis is placed on integral abutment behavior, since abutments together with piers are the most critical elements in securing the integrity of bridge superstructures during earthquakes. Comparison is made between analytical results and field measurements in order to establish the accuracy of the superstructure–abutment model. Sensitivity studies are conducted to investigate the effects of foundation stiffness on the overall dynamic and seismic response of the new bridge system.  相似文献   

15.
A hybrid analytical and FEM is proposed to investigate the nonlinear sloshing in a floating‐roofed oil storage tank under long‐period seismic ground motion. The tank is composed of a rigid cylindrical wall and a flat bottom, whereas the floating roof is treated as an elastic plate undergoing large deflection. The contained liquid is assumed to be inviscid and incompressible, and the flow is assumed to be irrotational. The method of analysis is based on representation of the liquid motion by superposing the analytical modes that satisfy the Laplace equation and the rigid wall and bottom boundary conditions. The FEM is then applied to solve the remaining kinematic and dynamic boundary conditions at the moving liquid surface coupled with the nonlinear equation of motion of the floating roof. This requires only the discretization of the liquid surface and the floating roof into finite elements, thus leading to a computationally efficient and accurate method compared with full numerical analysis. As numerical examples to illustrate the applicability of the proposed method, two oil storage tanks with single‐deck type floating roofs damaged during the 2003 Tokachioki earthquake are studied. It is shown that the nonlinear oscillation modes with the circumferential wave numbers 0, 2 and 3 caused by the finite liquid surface elevation as well as the membrane action due to large deflection of the deck produce excessively large stresses in the pontoon, which may cause the catastrophic failure of pontoon followed by the submergence of the roof. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
The simultaneous effects of soil–structure interaction, foundation uplift and inelastic behavior of the superstructure on total displacement response of soil–structure systems are investigated. The superstructure is modeled as an equivalent single‐degree‐of‐freedom system with bilinear behavior mounted on a rigid foundation resting on distributed tensionless Winkler springs and dampers. It is well known that the behavior of soil–structure systems can be well described using a limited number of nondimensional parameters. Here, by introducing two new parameters, the concept is extended to inelastic soil–structure systems in which the foundation is allowed to uplift. An extensive parametric study is conducted for a wide range of the key parameters through nonlinear time history analyses. It is shown that while uplifting soil–structure systems experience excessive displacements, in comparison with systems that are not allowed to uplift, ductility demand in the superstructure generally decreases owing to foundation uplift. A new inelastic displacement ratio (IDR) is proposed in conjunction with a nonlinear static analysis of uplifting soil–structure systems. Simplified expressions are also provided to estimate the proposed IDR. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
Main purpose of this study is to evaluate the dynamic behavior of fluid–rectangular tank–soil/foundation system with a simple and fast seismic analysis procedure. In this procedure, interaction effects are presented by Housner's two mass approximations for fluid and the cone model for soil/foundation system. This approach can determine; displacement at the height of the impulsive mass, the sloshing displacement and base forces for the soil/foundation system conditions including embedment and incompressible soil cases. Models and equations for proposed method were briefly explained for different tank–soil/foundation system combinations. By means of changing soil/foundation conditions, some comparisons are made on base forces and sloshing responses for the cases of embedment and no embedment. The results showed that the displacements and base shear forces generally decreased, with decreasing soil stiffness. However, embedment, wall flexibility, and soil–structure interaction (SSI) did not considerably affect the sloshing displacement.  相似文献   

18.
In this paper, an analytical method is proposed to determine the dynamic response of 3‐D rectangular liquid storage tanks with four flexible walls, subjected to horizontal seismic ground motion. Fluid–structure interaction effects on the dynamic responses of partially filled fluid containers, incorporating wall flexibility, are accounted for in evaluating impulsive pressure. The velocity potential in which boundary conditions are satisfied is solved by the method of separation of variables using the principle of superposition. The impulsive pressure distribution is then computed. Solutions based on 3‐D modeling of the rectangular containers are obtained by applying the Rayleigh–Ritz method using the vibration modes of flexible plates with suitable boundary conditions. Trigonometrical functions that satisfy boundary conditions of the storage tank such that the flexibility of the wall is thoroughly considered are used to define the admissible vibration modes. The analysis is then performed in the time domain. Moreover, an analytical procedure is developed for deriving a simple formula that evaluates convective pressure and surface displacements in a similar rigid tank. The variation of dynamic response characteristics with respect to different tank parameters is investigated. A mechanical model, which takes into account the deformability of the tank wall, is developed. The parameters of such a model can be obtained from developed charts, and the maximum seismic loading can be predicted by means of a response spectrum characterizing the design earthquake. Accordingly, a simplified but sufficiently accurate design procedure is developed to improve code formulas for the seismic design of liquid storage tanks. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
Train viaduct behavior and nearby ground motion under the high-speed train passage have been studied in this paper. First, the findings from the field measurement alongside the high-speed Shinkansen railway in Japan are interpreted. Then, the computer simulation is made based on the soil-foundation-viaduct interaction analysis under moving axle loads. The solution method is to apply the dynamic substructure method in the frequency domain. The viaduct girders including track structure and pier supports are modeled by the three-dimensional beam-column elements. The supporting pile foundation and nearby field are discretized by the axisymmetric three-dimensional finite elements and analyzed in a semi-analytical way, with a transmitting boundary replacing the far field based on the thin layer element method. Nearby ground motion during train passage on a viaduct have been calculated by superimposing the effects from neighboring pile foundations.The main parameters affecting viaduct vibrations are discussed by taking environmental vibration into consideration. The nearby ground motion along the viaduct is recomputed by applying the above determined forces to the foundation tops. The results from numerical studies are compared with the field test data, thus proving the present simulation to be effective and reliable.  相似文献   

20.
立式储罐与地基相互作用动力特性分析   总被引:2,自引:0,他引:2  
立式储罐结构在工程实际中得到广泛的应用。本文以某大型立式储罐结构为例,考虑到液体、结构、地基的相互作用与影响,同时考虑地基与结构及液体与结构的耦合问题,采用有限元方法对浮放在地基上的储罐结构进行了自振特性计算。分别计算了满罐和空罐时系统的频率以及所对应的振型图,并研究了储罐的材料参数和地基刚度对动力特性的影响。结果表明:材料参数的影响较小,地基刚度的影响较大,对盛满液体与空罐的影响不同。  相似文献   