首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The application of fiber reinforced plastic(FRP),including carbon FRP and glass FRP,for structural repair and strengthening has grown due to their numerous advantages over conventional materials such as externally bonded reinforcement(EBR) and near-surface mounted(NSM) strengthening techniques.This paper summarizes the results from 21 reinforced concrete beams strengthened with different methods,including externally-bonded and near-surface mounted FRP,to study the strain coordination of the FRP and steel rebar of the RC beam.Since there is relative slipping between the RC beam and the FRP,the strain of the FRP and steel rebar of the RC beam satisfy the quasi-plane-hypothesis;that is,the strain of the longitudinal fiber that parallels the neutral axis of the plated beam within the scope of the effective height(h 0) of the cross section is in direct proportion to the distance from the fiber to the neutral axis.The strain of the FRP and steel rebar satisfies the equation:ε FRP =βε steel,and the value of β is equal to 1.1-1.3 according to the test results.  相似文献   

2.
Bonding fiber reinforced polymer (FRP) has been commonly used to improve the seismic behavior of circular reinforced concrete (RC) columns in engineering practice. However, FRP jackets have a significant stress hysteresis effect in this strengthening method, and pre-tensioning the FRP can overcome this problem. This paper presents test results of 25 circular RC columns strengthened with pre-stressed FRP strips under low cyclic loading. The pre-stressing of the FRP strips, types of FRP strips and longitudinal reinforcement, axial load ratio, pre-damage degree and surface treatments of the specimens are considered as the primary factors in the tests. According to the failure modes and hysteresis curves of the specimens, these factors are analyzed to investigate their effect on bearing capacity, ductility, hysteretic behavior, energy dissipation capacity and other important seismic behaviors. The results show that the initial lateral confined stress provided by pre-stressed FRP strips can effectively inhibit the emergence and development of diagonal shear cracks, and change the failure modes of specimens from brittle shear failure to bending or bending-shear failure with better ductility. As a result, the bearing capacity, ductility, energy dissipation capacity and deformation capacity of the strengthened specimens are all significantly improved.  相似文献   

3.
纤维增强复合材料(Fiber Reinforced Polymer,简称"FRP")具有轻质高强、耐腐蚀、耐疲劳和低导热系数等优点,现已广泛应用于土木工程各领域。针对FRP约束钢筋混凝土结构的抗爆性能,通过综述近年来国内外爆炸荷载下FRP约束钢筋混凝土结构动力响应的研究现状及进展,表明FRP材料的约束对钢筋混凝土结构的抗爆性能有显著的提高作用。此外,从相关理论研究、试验研究和数值模拟3个方面介绍了主要成果。针对现有成果,对爆炸荷载下FRP约束钢筋混凝土结构动力响应研究提出了需要进一步研究和解决的问题,可为后续研究提供一定的参考。  相似文献   

4.
为研究加固后锈蚀箍筋约束混凝土柱的抗震性能,设计16个钢筋混凝土矩形柱,对加速锈蚀后的试件采用外包钢及CFRP、GFRP材料进行加固处理,随后开展低周往复荷载试验,以研究不同加固材料、不同加固包裹方式、不同黏结材料等因素对锈蚀箍筋约束混凝土柱滞回曲线、骨架曲线、刚度衰减、延性性能及耗能能力等抗震性能指标的影响。研究结果表明:(1)与未锈蚀柱相比,加固后的箍筋锈蚀柱以弯剪破坏为主,CFRP加固试件较GFRP加固试件具有更高的承载力,但破坏时延性不如GFRP加固试件;(2)外包钢加固试件、CFRP加固试件、GFRP加固试件的耗能能力较未锈蚀试件分别增大222.3%、123.9%、98.5%,延性系数也相应增大45.3%、22.3%、25.6%。总之,外包钢加固对箍筋锈蚀柱抗震性能的提升最大,CFRP加固次之,但优于GFRP加固;整包加固优于环包加固;环氧树脂胶黏结略优于水泥基灌浆料黏结。  相似文献   

5.
为研究不同加固方式对钢筋混凝土(RC)圆截面桥墩抗震性能的影响,利用OpenSees有限元软件建立了普通RC桥墩以及分别采用钢套管、碳纤维增强聚合物(CFRP)、体外预应力筋进行加固的桥墩数值分析模型,对模型输入远断层地震动,进行增量动力分析。以墩顶峰值位移角与震后残余位移角为指标,对比分析了桥墩加固前后的地震响应。结果表明:采用钢套管、体外预应力筋和CFRP加固后,RC桥墩的峰值位移与震后残余位移均减小,钢套管加固方式对桥墩峰值位移的降低幅度最大,体外预应力筋加固方式对抑制桥墩震后残余位移的效果最好;随着剪跨比的增大,3种加固方式对桥墩在地震动作用下位移响应的抑制作用均逐步减小;随着轴压比的增大,3种加固方式对RC桥墩峰值位移的抑制作用逐步降低。  相似文献   

6.
This work reports the results of an experimental programme aimed at investigating the in-plane behaviour of clay-brick masonry walls externally strengthened by carbon fiber reinforced polymer (CFRP) strips. Particularly, four different geometrical layouts were considered for the CFRP strips, though keeping unchanged the quantity of composites employed in each wall. Firstly, a preliminary experimental work was carried out on samples of the constitutive materials for quantifying their key mechanical properties and evaluating the bond behaviour of FRP strips on the masonry substrates. Then, eleven cyclic shear-compression tests were performed to observe the response of strengthened walls and the influence of the strengthening layouts under investigation. The proposed experimental report is intended as a contribution to the current state of knowledge about the behaviour of FRP-strengthened masonry walls: it is available to assess the accuracy and possibly improve the predictive capacity of design-oriented capacity models. Finally, the comparison of the reported experimental results with the predictions obtained by applying the analytical relationships proposed by a recently issued guideline for FRP strengthening of masonry structures is proposed.  相似文献   

7.
本文将数字错位散斑技术引入CFRP加固混凝土界面粘接质量的检测。对预制缺陷模型检测的结果表明,该方法能够迅速准确地对CFRP加固粘接质量作出检测和评价,为混凝土结构加固界面粘接质量无损诊断提供一种新思路。  相似文献   

8.
为验证 CFRP板条嵌入式加固方法对提升十字形 RC框架节点抗震性能的有效性,开展了1 个 CFRP板条嵌入式加固节点和1个对比节点的拟静力试验研究.试验结果表明:在核心区及相邻梁端嵌入 CFRP板条可起到类似箍筋的抗剪作用,使得节点由核心区剪切破坏转变为梁端受弯破坏,且梁铰得到转移;构件抗震性能明显提升,承载力和延性分别提高了16.3%和13.7%.同时, 利用 ABAQUS建立试验数据验证的有限元模型,并对节点主要加固设计参数进行影响分析.结果表明,节点承载力随着 CFRP板条面积的增大、板条间距的减小和基体混凝土强度的提高而提高.所提节点加固方法体现出塑性铰转移的抗震设计理念,同时提高核心区抗剪强度和梁端的抗弯强度,可用于 RC节点的抗震加固.  相似文献   

9.
在对5根T形梁进行U形箍加固试验基础上就实际加固设计中遇到的问题按梁的破坏形式,采用规范中的有关假定,并附加碳纤维布与梁粘结锚固可靠假定,利用截面的平面几何关系和力的平衡关系计算出梁的极限承载力,从而给出计算加固面积的实用方法。  相似文献   

10.
The opportunities provided by the use of fiber‐reinforced polymer (FRP) for the seismic retrofit of existing reinforced concrete (RC) structures were assessed on a full‐scale three‐story framed structure. The structure, designed only for gravity loads, was subjected to a bi‐directional pseudo‐dynamic (PsD) test at peak ground acceleration (PGA) equal to 0.20g at the ELSA Laboratory of the Joint Research Centre. The seismic deficiencies exhibited by the structure after the test were confirmed by post‐test assessment of structural seismic capacity performed by nonlinear static pushover analysis implemented on the lumped plasticity model of the structure. In order to allow the structure to withstand 0.30g PGA seismic actions, a retrofit using glass fiber‐reinforced polymer (GFRP) laminates was designed. The retrofit design was targeted to achieve a more ductile and energy dissipating global performance of the structure by increasing the ductility of columns and preventing brittle failure modes. Design assumptions and criteria along with nonlinear static pushover analysis to assess the overall capacity of the FRP‐retrofitted structure are presented and discussed. After the retrofit execution, a new series of PsD tests at both 0.20g and 0.30g PGA level were carried out. Theoretical predictions are compared with the main experimental outcomes to assess the effectiveness of the proposed retrofit technique and validate the adopted design procedures. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

11.
基于OpenSees的CFRP加固RC短柱抗震性能数值模拟   总被引:3,自引:1,他引:2  
采用地震工程开源模拟软件OpenSees对CFRP加固RC短柱进行了静力Push over分析和低周往复加载分析,并与通用有限元软件ANSYS模拟结果进行对比研究.研究结果表明:利用CFRP进行加固,不仅阻止了RC短柱的脆性剪切破坏,而且使破坏模式转化为延性弯曲破坏,增强了结构延性,进而有效地提高其抗震性能;同ANSYS相比,OpenSees可以宏观的反映CFRP与混凝土共同作用的非线性力学特征,有效地对构件和结构进行加固后的承载力及抗震性能分析.  相似文献   

12.
A numerical process that simulates crack propagation in reinforced concrete through post‐crack stress redistribution is presented. This process is developed within the context of the smeared crack approach. Continuity and orientation of the reinforcing bar components are automatically recognized in the pre‐processing stage. The process explicitly outputs crack widths by computing the bond slips along reinforcement, without imposing any additional nodes between the reinforcement and concrete. The process is incorporated with a finite element algorithm, and the validation is investigated through sample 3D static analyses of nine concrete specimens subjected to monotonic shear and flexure loads. These specimens contain relatively well‐distributed steel bars and fiber reinforced polymer (FRP) sheets of reinforcement ratio from 0.11 to 0.57%. The analyses predict the crack patterns and crack widths well, although some disagreements are found between the test and the analysis results. The proposed process outputs discrete, continuous in crack directions, and element boundary‐free crack patterns. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

13.
This paper presents a new FRP retrofi tting scheme to strengthen local beam-column joints in reinforced concrete(RC) frames.The new retrofi tting scheme was proposed following a preliminary study of four different existing retrofi tting schemes.A numerical simulation was conducted to evaluate the effectiveness of FRP-strengthened reinforced concrete frames by bridging behavior of local joints to the whole structure.Local confi nement effects due to varying retrofi tting schemes in the joints were simulated in the frame model.The seismic behavior factor was used to evaluate the seismic performance of the strengthened RC frames.The results demonstrated that the new proposed retrofi tting scheme was robust and promising,and fi nite element analysis appropriately captured the strength and global ductility of the frame due to upgrading of the local joints.  相似文献   

14.
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures.  相似文献   

15.
宋丹  李林 《地震工程学报》2019,41(6):1671-1678
为避免震后建筑工程加固不合理导致再次受损,并为加固修复工程提供合理化建议,促进震后救灾工作顺利开展,提出震后建筑工程混凝土缺陷加固修复方法的研究。首先,对混凝土梁试件和混凝土柱试件进行设置,研究基于碳纤维布或外包钢套加固方法对混凝土梁和混凝土柱试件展开循环荷载试验;其次,通过混凝土梁试件滞回曲线、骨架曲线、延性及耗能情况,分析不同加固修复方法的混凝土梁试件抗震性能;最后,通过混凝土柱试件延性及耗能、刚度退化和承载力退化情况,分析采用不同加固方法修复的混凝土柱试件抗震性能。试验结果显示:高配筋率可提升混凝土梁试件滞回特性,外包钢套加固混凝土梁试件滞回饱满程度较高、耗能较少,碳纤维布加固梁试件可将加载位移由10 mm延缓至30 mm,提升延性;碳纤维布加固可提升混凝土柱延性,外包钢套加固重度缺陷混凝土柱可以良好抑制其刚度和承载力退化。试验结果验证了碳纤维加固可提升震后建筑工程混凝土结构延性,外包钢套加固可抑制混凝土结构刚度、承载力退化。  相似文献   

16.
纤维加固混凝土圆截面短柱抗震性能试验研究   总被引:3,自引:0,他引:3  
通过对3根抗剪不足的混凝土圆截面短柱的拟静力试验,不仅验证了横向包裹的碳纤维布能提高短柱的抗剪承载力,改善混凝土的变形性能,从而提高短柱的抗震性能,同时验证了具有一定破损的短柱经碳纤维布强约束加固后,同样具有良好的抗震性能。文章最后对碳纤维布加固短柱的延性提高机理进行了分析。  相似文献   

17.
SRC框格复合墙是在普通RC密肋复合墙基础上结合型钢混凝土概念而提出来的一种复合墙板,以轻钢龙骨代替框格内原有纵向受力钢筋,通过焊接或螺栓连接在梁柱轻钢龙骨节点处实现刚性或半刚性连接.在SRC框格复合墙模型试验基的础上,利用ANSYS程序对墙体受力过程进行了非线性有限元分析,提出了SRC框格复合墙抗剪承载力的实用计算公式,并对框格含钢率、轻钢强度等影响因素进行了有限元分析.研究结果表明:所提出的SRC框格复合墙抗剪承载力计算公式,与非线性有限元计算结果吻合较好,能够适应框格含钢率等不同因素变化的计算精度要求;提高肋梁中轻钢强度或含钢率可以有效提高墙体抗剪承载力,而不宜单独采用提高混凝土强度的方法.  相似文献   

18.
In this paper, a fiber beam-column element considering flexure–shear interaction and bond-slip effect is developed for cyclic analysis of reinforced concrete (RC) structures. The element is based on conventional displacement-based Timoshenko beam theory, where the transverse shear deformation is included, and adopts the fiber model to describe the section force–deformation behavior. In the fiber model, shear deformation is assumed to be uniformly distributed along the section and is only resisted by concrete, thus the multi-dimensional concrete damage model is used for concrete fibers and therefore flexure–shear interaction is reflected naturally at the material level. Meanwhile, to account for the significant bond-slip effect at critical regions, the anchorage slip of bars at these regions is analytically derived. Then it is used to modify the uniaxial stress–strain model for steel fibers by assuming that the total strain can be treated as the sum of the bar deformation and anchorage slip, therefore the bond-slip effect is implicitly but simply represented. To validate the proposed element, a series of RC member and structure tests under cyclic loading are simulated. The results indicate that the proposed element can predict cyclic responses of RC structures, and can be used as a reliable tool for analysis of RC structures.  相似文献   

19.
This paper presents a new type of structural bracing intended for seismic retrofitting use in framed structures. This special composite brace,termed glass-fiber-reinforced-polymer(GFRP)-tube-confined-concrete composite brace,is comprised of concrete confined by a GFRP tube and an inner steel core for energy dissipation.Together with a contribution from the GFRP-tube confined concrete,the composite brace shows a substantially increased stiffness to control story drift, which is often a preferred feature in seismic retrofitting.An analysis model is established and implemented in a general finite element analysis program-OpenSees,for simulating the load-displacement behavior of the composite brace.Using this model,a parametric study of the hysteretic behavior(energy dissipation,stiffness,ductility and strength)of the composite brace was conducted under static cyclic loading and it was found that the area ratio of steel core to concrete has the greatest influence among all the parameters considered.To demonstrate the application of the composite brace in seismic retrofitting, a three-story nonductile reinforced concrete(RC)frame structure was retrofitted with the composite braces.Pushover analysis and nonlinear time-history analyses of the retrofitted RC frame structure was performed by employing a suite of 20 strong ground motion earthquake records.The analysis results show that the composite braces can effectively reduce the peak seismic responses of the RC frame structure without significantly increasing the base shear demand.  相似文献   

20.
This paper presents the results of an experimental study on the determination of damping characteristics of bare, masonry infilled, and carbon fiber reinforced polymer retrofitted infilled reinforced concrete (RC) frames. It is well known that the masonry infills are used as partitioning walls having significant effect on the damping characteristics of structures as well as contribution to the lateral stiffness and strength. The main portion of the input energy imparted to the structure during earthquakes is dissipated through hysteretic and damping energies. The equivalent damping definition is used to reflect various damping mechanisms globally. In this study, the equivalent damping ratio of carbon fiber reinforced polymer retrofitted infilled RC systems is quantified through a series of 1/3‐scaled, one‐bay, one‐story frames. Quasi‐static tests are carried out on eight specimens with two different loading patterns: one‐cycled and three‐cycled displacement histories and the pseudo‐dynamic tests performed on eight specimens for selected acceleration record scaled at three different PGA levels with two inertia mass conditions. The results of the experimental studies are evaluated in two phases: (i) equivalent damping is determined for experimentally obtained cycles from quasi‐static and pseudo‐dynamic tests; and (ii) an iterative procedure is developed on the basis of the energy balance formulation to determine the equivalent damping ratio. On the basis of the results of these evaluations, equivalent damping of levels of 5%, 12%, and 14% can be used for bare, infilled, and retrofitted infilled RC frames, respectively. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号