首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study uses instrumented buildings and models of code‐based designed buildings to validate the results of previous studies that highlighted the need to revise the ASCE 7 Fp equation for designing nonstructural components (NSCs) through utilizing oversimplified linear and nonlinear models. The evaluation of floor response spectra of a large number of instrumented buildings illustrates that, unlike the ASCE 7 approach, the in‐structure and the component amplification factors are a function of the ratio of NSC period to the supporting building modal periods, the ground motion intensity, and the NSC location. It is also shown that the recorded ground motions at the base of instrumented buildings in most cases are significantly lower than design earthquake (DE) ground motions. Because ASCE 7 is meant to provide demands at a DE level, for a more reliable evaluation of the Fp equation, 2 representative archetype buildings are designed based on the ASCE 7‐16 seismic provisions and exposed to various ground motion intensity levels (including those consistent with the ones experienced by instrumented buildings and the DE). Simulation results of the archetype buildings, consistent with previous numerical studies, illustrate the tendency of the ASCE 7 in‐structure amplification factor, [1 + 2(z/h)] , to significantly overestimate demands at all floor levels and the ASCE 7 limit of to in many cases underestimate the calculated NSC amplification factors. Furthermore, the product of these 2 amplification factors (that represents the normalized peak NSC acceleration) in some cases exceeds the ASCE 7 equation by a factor up to 1.50.  相似文献   

2.
This paper investigates the response of nonstructural components in the presence of nonlinear behavior of the primary structure using floor response spectra method (FRS). The effect of several parameters such as initial natural frequency of the primary structure, natural frequency of the nonstructural components (subsystem), strength reduction factor and hysteretic model have been studied. A database of 164 registered ground acceleration time histories from the European Strong-Motion Database is used. Results are presented in terms of amplification factor and resonance factor. Amplification factor quantifies the effect of inelastic deformations of the primary structure on subsystem response. Resonance factor quantifies the variation of the subsystem response considering the primary structure acceleration. Obtained results differed from precedent studies, particularly for higher primary structure periods. Values of amplification factor are improved. Obtained results of resonance factor highlight an underestimation of peak values according to current design codes such as Eurocode 8. Therefore a new formulation is proposed.  相似文献   

3.
Strength-reduction factors that reduce ordinates of floor spectra acceleration due to nonlinearity in the secondary system are investigated. In exchange for permitting some inelastic deformation to occur in the secondary system or its supports, these strength reduction factors allow to design the nonstructural elements or their supports for lateral forces that are smaller than those that would be required to maintain them elastically during earthquakes. This paper presents the results of a statistical analysis on component strength-reduction factors that were computed considering floor motions recorded on instrumented buildings in California during various earthquakes. The effect of yielding in the component or its anchorage/bracing in offering protection against excessive component acceleration demands is investigated. It is shown that strength-reduction factors computed from floor motions are significantly different from those computed from ground motions recorded on rock or on firm soils. In particular, they exhibit much larger reductions for periods tuned or nearly tuned to the dominant modal periods of the building response. This is due to the large differences in frequency content of ground motions and floor motions, with the former typically characterized by wide-band spectra whereas the latter are characterized by narrow-band spectra near periods of dominant modes in the response of the building. Finally, the study provides approximate equations to estimate component strength-reduction factors computed through nonlinear regression analyses.  相似文献   

4.
Response parameters used to estimate nonstructural damage differ depending on whether deformation‐sensitive or acceleration‐sensitive components are considered. In the latter case, seismic demand is usually represented through floor spectra, that is response spectra in terms of pseudo‐acceleration, which are calculated at the floor levels of the structure where the nonstructural components are attached to. Objective of this paper is to present a new spectrum‐to‐spectrum method for calculating floor acceleration spectra, which is able to explicitly account for epistemic uncertainties in the modal properties of the supporting structure. By using this method, effects on the spectra of possible variations from nominal values of the periods of vibration of the structure can be estimated. The method derives from the extension of closed‐form equations recently proposed by the authors to predict uniform hazard floor acceleration spectra. These equations are built to rigorously account for the input ground motion uncertainty, that is the record‐to‐record variability of the nonstructural response. In order to evaluate the proposed method, comparisons with exact spectra obtained from a standard probabilistic seismic demand analysis, as well as spectra calculated using the Eurocode 8 equation, are finally shown. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

5.
In this paper, vertical peak floor acceleration (PFAv) demands on elastic multistory buildings are statistically evaluated using recorded ground motions. These demands are applicable to the assessment of nonstructural components that are rigid in the vertical direction and located at column lines or next to columns. Hence, PFAv demands of the floor system away from column lines and their effects on nonstructural components are not addressed. This study is motivated by the questionable general assumption that typical buildings are considered to be relatively flexible in the horizontal (lateral) direction but relatively rigid in the vertical (longitudinal) direction. Consequently, only few papers address the evaluation of vertical component acceleration demands throughout a building, and there is no consensus on the relevance of vertical accelerations in buildings. The results presented in this study show that the vertical ground acceleration demands are amplified throughout the column line of a steel frame structure. This amplification is in many cases significant, depending on the vertical stiffness of the load‐bearing system, damping ratio, and the location of the nonstructural component in the building. From these outcomes it can be concluded that the perception of a rigid‐body response of the column lines in the vertical direction is highly questionable, and further research on this topic is required. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
The available models for eff ective periods of site and structure are reviewed in context of frequency tuning in the inelastic seismic response of soil-structure system. The eff ect of seismic intensity and ductility demand, on the eff ective periods, is investigated, and inelastic site amplifi cation is shown to be strongly correlated to the normalized eff ective period. Two non-dimensional parameters, analogous to the conventional site amplifi cation factors in codes, are defi ned to quantify the inelastic site amplifi cation. It is shown that the inelastic site amplifi cation factor (i.e. ratio of constant ductility spectral ordinates at soil site to those at rock outcrop) is able to represent the site eff ects more clearly, as compared to the inelastic site amplifi cation ratio (i.e. ratio of inelastic spectral ordinates at soil site to the corresponding elastic spectral ordinates at rock outcrop). Further, the peak in the amplifi cation factor corresponding to the eff ective site period diminishes rapidly with increasing ductility demand.  相似文献   

7.
当前,合理确定地震动峰值加速度与反应谱特征周期是工程场地地震动参数确定工作的主要内容。本文以北京地区典型中硬场地为研究对象,分析场地条件对不同周期地震动反应谱值的影响。首先,计算不同震级、震中距条件下的基岩地震动加速度反应谱,合成基岩输入地震动时程;再利用110个工程场地的钻孔资料进行土层地震反应计算,分析中硬场地条件对不同输入环境下的地震动加速度反应谱值的放大效应。结果表明,中硬场地对高、中频震动放大效应明显,尤其是对0.2-0.5s周期段地震动加速度反应谱值的放大倍数大多在1.3以上;场地覆盖层厚度变化对不同频段地震动加速度反应谱值的放大倍数所产生的影响是不同的,与场地自振周期的相关性很强;在不同的地震动输入环境下,中硬场地对不同频段地震动加速度反应谱的影响是不同的,这一结论对实际的抗震设防工作具有一定参考价值。  相似文献   

8.
This paper presents a practical method to compute uniform hazard floor acceleration spectra for linear oscillators attached to a linear structure. The method builds on a probabilistic seismic demand model that relates the acceleration response of the oscillator with that of the generic mode of vibration of the supporting structure. Interaction between oscillator and structure is ignored. Independency of the model on the specific characteristics of seismic hazard at the site is shown. By using the method floor spectra are determined through a closed‐form expression, given the mean annual frequency of interest, the damping ratio of the oscillators, the modal properties of the structure, and three uniform hazard spectra representing seismic hazard at the site. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
This paper assesses the influence of cyclic and in‐cycle degradation on seismic drift demands in moment‐resisting steel frames (MRF) designed to Eurocode 8. The structural characteristics, ground motion frequency content, and level of inelasticity are the primary parameters considered. A set of single‐degree‐of‐freedom (SDOF) systems, subjected to varying levels of inelastic demands, is initially investigated followed by an extensive study on multi‐storey frames. The latter comprises a large number of incremental dynamic analyses (IDA) on 12 frames modelled with or without consideration of degradation effects. A suite of 56 far‐field ground motion records, appropriately scaled to simulate 4 levels of inelastic demand, is employed for the IDA. Characteristic results from a detailed parametric investigation show that maximum response in terms of global and inter‐storey drifts is notably affected by degradation phenomena, in addition to the earthquake frequency content and the scaled inelastic demands. Consistently, both SDOF and frame systems with fundamental periods shorter than the mean period of ground motion can experience higher lateral strength demands and seismic drifts than those of non‐degrading counterparts in the same period range. Also, degrading multi‐storey frames can exhibit distinctly different plastic mechanisms with concentration of drifts at lower levels. Importantly, degrading systems might reach a “near‐collapse” limit state at ductility demand levels comparable to or lower than the assumed design behaviour factor, a result with direct consequences on optimised design situations where over‐strength would be minimal. Finally, the implications of the findings with respect to design‐level limit states are discussed.  相似文献   

10.
Predictors (or estimates) of seismic structural demands that are less computationally time‐consuming than non‐linear dynamic analysis can be useful for structural performance assessment and for design. In this paper, we evaluate the bias and precision of predictors that make use of, at most, (i) elastic modal vibration properties of the given structure, (ii) the results of a non‐linear static pushover analysis of the structure, and (iii) elastic and inelastic single‐degree‐of‐freedom time‐history analyses for the specified ground motion record. The main predictor of interest is an extension of first‐mode elastic spectral acceleration that additionally takes into account both the second‐mode contribution to (elastic) structural response and the effects of inelasticity. This predictor is evaluated with respect to non‐linear dynamic analysis results for ‘fishbone’ models of steel moment‐resisting frame (SMRF) buildings. The relatively small number of degrees of freedom for each fishbone model allows us to consider several short‐to‐long period buildings and numerous near‐ and far‐field earthquake ground motions of interest in both Japan and the U.S. Before doing so, though, we verify that estimates of the bias and precision of the predictor obtained using fishbone models are effectively equivalent to those based on typical ‘full‐frame’ models of the same buildings. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

11.
This paper deals with floor acceleration spectra, which are used for the seismic design and assessment of acceleration‐sensitive equipment installed in buildings. In design codes and in practice, not enough attention has been paid to the seismic resistance of such equipment. An ‘accurate’ determination of floor spectra requires a complex and quite demanding dynamic response history analysis. The purpose of the study presented in this paper is the development of a direct method for the determination of floor acceleration spectra, which enables their generation directly from the design spectrum of the structure, by taking into account the structure's dynamic properties. The method is also applicable to inelastic structures, which can greatly improve the economic aspects of equipment design. A parametric study of floor acceleration spectra for elastic and inelastic single‐degree‐of‐freedom (SDOF) and multiple‐degree‐of‐freedom structures was conducted by using (non)linear response history analysis. The equipment was modelled as an elastic single‐degree‐of‐freedom system. The proposed method was validated by comparing the results obtained with the more accurate results obtained in a parametric study. Due to its simplicity, the method is an appropriate tool for practice. In the case of inelastic structural behaviour, the method should be used in combination with the N2 method, or another appropriate method for simplified nonlinear structural analysis. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
To reduce floor acceleration of base‐isolated structures under earthquakes, a tuned mass damper (TMD) system installed on the roof is studied. The optimal tuning parameters of the TMD are analyzed for linear base isolation under a generalized ground motion, and the performance of the TMD is validated using a suite of recorded ground motions. The simulation shows that a TMD tuned to the second mode of a base‐isolated structure reduces roof acceleration more effectively than a TMD tuned to the first mode. The reduction ratio, defined as the maximum roof acceleration with the TMD relative to that without the TMD, is approximately 0.9 with the second‐mode TMD. The higher effectiveness of the second‐mode TMD relative to the first‐mode TMD is attributed primarily to the unique characteristics of base isolation, ie, the relatively long first‐mode period and high base damping. The modal acceleration of the second mode is close to or even higher than that of the first mode in base‐isolated structures. The larger TMD mass ratio and lower modal damping ratio of the second‐mode TMD compared to the first‐mode TMD increases its effect on modal acceleration reduction. The reduction ratio with the second‐mode TMD improves to 0.8 for bilinear base isolation. Because of the detuning effect caused by the change in the first‐mode period in bilinear isolation, the first‐mode TMD is ineffective in reducing roof acceleration. Additionally, the displacement experienced by the second‐mode TMD is considerably smaller than that of the first‐mode TMD, thereby reducing the installation space for the TMD.  相似文献   

13.
Two one‐way eccentric, two‐storey, one‐by‐one‐bay reinforced concrete (RC) structures are pseudodynamically tested under unidirectional ground motions. Theoretical considerations about the effect of torsional coupling on modal periods and shapes agree with modal results of the test structure, considering member stiffness is equal to the secant stiffness to yielding in skew‐symmetric bending. Modal periods of such an elastic structure are in fair agreement with effective periods inferred from the measured response at the beginning of a test of a thoroughly cracked structure and at the end of the test. A time‐varying stiffness matrix and a non‐proportional damping matrix fitted to the test results may be used to reproduce the measured response approximately by modal superposition and identify the role of the four time‐varying modes. Flexible side columns sustained very large drift demands simultaneously in the two transverse directions and suffered significant but not heavy, damage at lap‐splices. RC‐jacketing of the flexible side columns practically eliminated the static eccentricity between the floor centres of twist and mass as well as the torsional response. Inelastic time‐history analysis with point‐hinge member models, using as elastic stiffness the secant stiffness to yielding and neglecting post‐ultimate‐strength cyclic degradation of resistance in members with plain bars and poor detailing, predicted fairly well the response until the peak displacements and member deformations occurred. After that, it underestimated displacement peaks and the lengthening of the apparent period and missed the gradual drifting of the response towards a permanent offset. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

14.
A simple calculation procedure for estimating absolute maximum slip displacement of a freestanding rigid body placed on the ground or floor of linear/nonlinear multi‐storey building during an earthquake is developed. The proposed procedure uses the displacement induced by the horizontal sinusoidal acceleration to approximate the absolute maximum slip displacement, i.e. the basic slip displacement. The amplitude of this horizontal sinusoidal acceleration is identical to either the peak horizontal ground acceleration or peak horizontal floor response acceleration. Its period meets the predominant period of the horizontal acceleration employed. The effects of vertical acceleration are considered to reduce the friction force monotonously. The root mean square value of the vertical acceleration at the peak horizontal acceleration is used. A mathematical solution of the basic slip displacement is presented. Employing over one hundred accelerograms, the absolute maximum slip displacements are computed and compared with the corresponding basic slip displacements. Their discrepancies are modelled by the logarithmic normal distribution regardless of the analytical conditions. The modification factor to the basic slip displacement is quantified based on the probability of the non‐exceedence of a certain threshold. Therefore, the product of the modification factor and the basic slip displacement gives the design slip displacement of the body as the maximum expected value. Since the place of the body and linear/nonlinear state of building make the modification factor slightly vary, ensuring it to suit the problem is essential to secure prediction accuracy. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

15.
现阶段基于性能的抗震设计思想不仅关注结构自身体系的安全,而且保护非结构构件在地震作用下使用功能完好。对于工业建筑结构,生产设备在地震作用下受损会影响震后功能恢复。加速度敏感型非结构构件一般采用楼层加速度指标来量化其地震损伤程度。以三个不同高度的钢抗弯框架规则结构体系为研究对象,采用与竖向目标谱匹配的近断层非脉冲和脉冲地震动作为竖向地震输入,考察不同质量不规则程度下,楼层竖向绝对加速度随建筑高度的变化趋势,并从反应谱角度分析不规则质量分布对楼层加速度响应的影响。结果表明:4层结构在非脉冲地震作用下楼层顶层处竖向绝对加速度是地面竖向峰值加速度的5倍之多,某一层质量的突变会引起该层及其他楼层竖向绝对加速度的明显变化。另外,对现有计算楼层竖向加速度响应的经验公式进行验证,发现美国ASCE 7-16规范的估计结果偏于保守。  相似文献   

16.
The peak floor acceleration (PFA) is a critical parameter influencing the performance of non‐structural elements in buildings. This paper develops a response spectrum analysis method based on the complete quadratic combination (CQC) rule to estimate the PFA. The method accounts for the rigid contribution of truncated higher modes and the cross‐correlations between all pairs of modes. The approximation is introduced in the time domain and then formulated in the frequency domain by CQC. Application of the method to a continuous cantilever beam idealizing a building with shear walls is presented and compared with alternative formulations. The proposed method is able to provide a consistent estimation of the PFA along the entire structure, not only where the PFA is principally influenced by the first few flexible modes but also where the PFA is mainly related to the rigid response of the structure, for example, near its base. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
The seismic demand parameters including the floor acceleration amplification (FAA) factors and the interstory drift ratios (IDRs) were acquired from the floor response in time history analysis of a tall building subjected to selected ground motions. The FAA factors determined in this way are larger than those given in most current code provisions, but the obtained IDRs are close to the values given in some code provisions. Imposing a series of in‐plane pre‐deformations to two glass curtain wall (CW) specimens mounted on a shaking table, the IDRs were reproduced and the FAA factors were satisfied through applications of computed floor spectra compatible motion time histories, whose peak accelerations corresponded to the FAA factors. The CW specimens performed well during the whole experimental program with almost no change in the fundamental frequencies. No visible damage was observed in the glass panels. The maximum stresses detected in each component of the CW system were smaller than the design strengths. The obtained component acceleration amplification factor approached 3.35, which is larger than the value given in the current code provisions. In conclusion, the performance of the studied CW system is seismically safe. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

18.
A suite of reinforced‐concrete frame buildings located on hill sides, with 2 different structural configurations, viz step‐back and split‐foundation, are analyzed to study their floor response. Both step‐back and split‐foundation structural configurations lead to torsional effects in the direction across the slope due to the presence of shorter columns on the uphill side. Peak floor acceleration and floor response spectra are obtained at each storey's center of rigidity and at both its stiff and flexible edges. As reported in previous studies as well, it is observed that the floor response spectra are better correlated with the ground response spectrum. Therefore, the floor spectral amplification functions are obtained as the ratio of spectral ordinates at different floor levels to the one at the ground level. Peaks are observed in the spectral amplification functions corresponding to the first 2 modes in the upper portion of the hill‐side buildings, whereas a single peak corresponding to a specific kth mode of vibration is observed on the floors below the uppermost foundation level. Based on the numerical study for the step‐back and split‐foundation hill‐side buildings, simple floor spectral amplification functions are proposed and validated. The proposed spectral amplification functions take into account both the buildings' plan and elevation irregularities and can be used for seismic design of acceleration‐sensitive nonstructural components, given that the supporting structure's dynamic characteristics, torsional rotation, ground‐motion response spectrum, and location of the nonstructural components within the supporting structure are known, because current code models are actually not applicable to hill‐side buildings.  相似文献   

19.
基于海域场地分类标准,选取南海海域实测钻孔作为计算模型,同时人工构造部分钻孔计算模型,对126条不同特性地震动输入下5种类别场地计算模型开展土层反应分析计算,分析不同地震动输入下不同海域场地峰值加速度和特征周期变化规律.结果表明,场地类别和地震动输入强度显著影响峰值加速度放大系数和特征周期,场地土越软,地震动输入强度越...  相似文献   

20.
The ‘equal displacement’ rule is employed in seismic design practice to predict inelastic displacements from analyses of the corresponding linear elastic structural models. The accuracy and limitations of this rule have been investigated for ordinary structures but not for bridges subjected to spatially varying ground motions. The present study investigates this rule for moderate levels of inelastic behavior for four highway bridges in California accounting for the effects of spatial variability of the support motions due to incoherence, wave passage and differential site response. The bridge models vary significantly as to their fundamental periods and their overall configurations. Statistical analyses of pier‐drift responses are performed using as input simulated arrays of nonstationary ground motions in accordance with prescribed coherency models. It is found that the ‘equal displacement’ rule is fairly accurate for cases when the fundamental period of the bridge is longer than the transition period between the acceleration‐controlled and velocity‐controlled ranges of the response spectrum. Otherwise, the rule is non‐conservative for cases with large ductility factors and conservative for cases with small ductility factors. Wave passage and incoherence tend to reduce ratios of mean peak inelastic to elastic pier drifts, whereas incorporation of the differential site‐response effect by locating piers on softer soils tends to increase the same ratios. Mild or moderate positive correlation between these ratios and ductility demands is observed in most cases. Effects of spatial variability are more pronounced for longer and stiffer bridges. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   