首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A common effective method to reduce the seismic response of liquid storage tanks is to isolate them at base using base-isolation systems. It has been observed that in many earthquakes, the foregoing systems significantly affect on the whole system response reduction. However, in exceptional cases of excitation by long-period shaking, the base-isolation systems could have adverse effects. Such earthquakes could cause tank damage due to excessive liquid sloshing. Therefore, the numerical seismic response of liquid storage tanks isolated by bilinear hysteretic bearing elements is investigated under long-period ground motions in this research. For this purpose, finite shell elements for the tank structure and boundary elements for the liquid region are employed. Subsequently, fluid–structure equations of motion are coupled with governing equation of base-isolation system, to represent the whole system behavior. The governing equations of motion of the whole system are solved by an iterative and step-by-step algorithm to evaluate the response of the whole system to the horizontal component of three ground motions. The variations of seismic shear forces, liquid sloshing heights, and tank wall radial displacements are plotted under various system parameters such as the tank geometry aspect ratio (height to radius), and the flexibility of the isolation system, to critically examine the effects of various system parameters on the effectiveness of the base-isolation systems against long-period ground motions. From these analyses, it may be concluded that with the installation of this type of base-isolation system in liquid tanks, the dynamic response of tanks during seismic ground motions can be considerably reduced. Moreover, in the special case of long-period ground motions, the seismic response of base-isolated tanks may be controlled by the isolation system only at particular conditions of slender and broad tanks. For the case of medium tanks, remarkable attentions would be required to be devoted to the design of base-isolation systems expected to experience long-period ground motions.  相似文献   

2.
Seismic fragility curves for fixed-base and base-isolated liquid storage tanks are developed under non-stationary earthquakes, and their seismic performance are compared. The correlation between different earthquake intensity measure (IM) parameters and peak response quantities of the base-isolated liquid storage tanks are investigated. The failure criteria are chosen based on (1) the elastic buckling strength of the tank wall, which is defined in terms of critical base shear and critical overturning moment, and (2) in terms of the critical isolation displacement. The uncertainty involved is considered in the earthquake characteristics. Non-stationary earthquake ground motions are generated using Monte Carlo (MC) simulation. Influence of the isolator characteristic parameters and modeling approaches on the seismic fragility of the base-isolated liquid storage tanks is also investigated. Peak ground acceleration is found to be the well correlated IM parameter with the peak response quantities of the base-isolated liquid storage tanks. Substantial decrease in the seismic fragility of the base-isolated liquid storage tanks is observed as compared to the fixed-base tanks. Significant influence of the isolator characteristic parameters on the seismic fragility of the base-isolated liquid storage tanks are reported in the present study.  相似文献   

3.
为研究考虑桩土相互作用的储液罐的动力响应及长周期地震波对储液晃动、储罐提离的影响,根据量纲分析法设计了桩-土-储罐模型进行了振动台试验。试验中采用4条基岩波、4条地表波进行振动台试验。试验显示基岩波与地表波输入时,体系变化规律基本一致,其结果表明:土体地表加速度被放大,且输入加速度峰值增加,地表加速度放大倍数减小;一般地震波时,随着输入加速度峰值的增加,储液晃动波高大致呈线性增加。长周期地震波下则为非线性增加,且晃动波较大。此外,液体产生的晃动波高与储罐类型相关。细高型储罐产生的波高稍大;储罐提离高度随着输入加速度峰值的增加呈非线性增长。长周期地震波激励下,储罐提离高度小于一般地震波时的提离高度。细高型储罐在长短周期地震波激励下,提离高度较为接近,而一般储罐在两种地震波激励下,提离高度相差较大。细高型储罐提离高度大于一般储罐的提离高度。建议在储罐设计时考虑长周期地震波的影响。  相似文献   

4.
In this paper, an analytical method is proposed to determine the dynamic response of 3‐D rectangular liquid storage tanks with four flexible walls, subjected to horizontal seismic ground motion. Fluid–structure interaction effects on the dynamic responses of partially filled fluid containers, incorporating wall flexibility, are accounted for in evaluating impulsive pressure. The velocity potential in which boundary conditions are satisfied is solved by the method of separation of variables using the principle of superposition. The impulsive pressure distribution is then computed. Solutions based on 3‐D modeling of the rectangular containers are obtained by applying the Rayleigh–Ritz method using the vibration modes of flexible plates with suitable boundary conditions. Trigonometrical functions that satisfy boundary conditions of the storage tank such that the flexibility of the wall is thoroughly considered are used to define the admissible vibration modes. The analysis is then performed in the time domain. Moreover, an analytical procedure is developed for deriving a simple formula that evaluates convective pressure and surface displacements in a similar rigid tank. The variation of dynamic response characteristics with respect to different tank parameters is investigated. A mechanical model, which takes into account the deformability of the tank wall, is developed. The parameters of such a model can be obtained from developed charts, and the maximum seismic loading can be predicted by means of a response spectrum characterizing the design earthquake. Accordingly, a simplified but sufficiently accurate design procedure is developed to improve code formulas for the seismic design of liquid storage tanks. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
The seismic response of an isolated vertical, cylindrical, extra-large liquefi ed natural gas (LNG) tank by a multiple friction pendulum system (MFPS) is analyzed. Most of the extra-large LNG tanks have a fundamental frequency which involves a range of resonance of most earthquake ground motions. It is an effective way to decrease the response of an isolation system used for extra-large LNG storage tanks under a strong earthquake. However, it is diff icult to implement in practice with common isolation bearings due to issues such as low temperature, soft site and other severe environment factors. The extra-large LNG tank isolated by a MFPS is presented in this study to address these problems. A MFPS is appropriate for large displacements induced by earthquakes with long predominant periods. A simplifi ed fi nite element model by Malhotra and Dunkerley is used to determine the usefulness of the isolation system. Data reported and statistically sorted include pile shear, wave height, impulsive acceleration, convective acceleration and outer tank acceleration. The results show that the isolation system has excellent adaptability for different liquid levels and is very effective in controlling the seismic response of extra-large LNG tanks.  相似文献   

6.
林树潮     《世界地震工程》2021,(1):129-136
为了研究高阶晃动振型对LNG储罐地震响应的影响,考虑高阶晃动振型,建立LNG储罐的简化力学模型,推导LNG储罐的运动控制方程,给出了LNG储罐的基底剪力、倾覆弯矩和储罐内液体晃动波高的表达式。以某16×104 m3 LNG储罐为例,采用大型通用有限元分析软件ADINA System对其进行有限元模型分析,验证其修正模型的有效性,结果表明:高阶晃动振型对基底剪力和倾覆弯矩几乎无影响,但对晃动波高影响显著,尤其是长周期地震动作用下,并且考虑高阶晃动振型的晃动波高存在延时效应。提出的简化力学模型修正公式与有限元分析结果吻合较好,可以准确地预测LNG储罐地震响应。  相似文献   

7.
大型储液罐摩擦摆基底隔震控制分析   总被引:2,自引:1,他引:1  
针对弹性钢制圆柱储液罐,基于Haroun-Housner模型,将连续流体质量等效为3种集中质量,分别为:对流质量、脉冲质量和刚性质量,与这些集中质量连接的相应刚度取值依赖于储罐壁和流体质量.在水平地震激励下,在储罐底部加摩擦单摆支座,给出了简化的液体 - 储罐-隔震支座的力学分析模型,建立了摩擦摆支座基底隔震体系的振动控制方程,并利用Newmark逐步积分法对控制方程进行了数值求解,研究了摩擦摆支座基底隔震的储液罐地震反应,验证了FPB隔震的有效性.  相似文献   

8.
研究不同高径比橡胶基底隔震储罐的频率特征,探讨储罐隔震体系3种不同振动频率随支座隔震频率变化规律.分析在不同频谱特性地震波激励下,隔震体系各振型组分对地震响应(基底剪力、支座位移和晃动波高)的影响,以及响应峰值随支座隔震频率和阻尼比的变化特点.研究表明,基底剪力峰值与场地地震波频谱特性密切相关.支座隔震频率不能完全反映减震机理的实质,隔震振型频率是影响基底剪力的重要参数.在软弱场地上隔震储罐的减震效率低,有效隔震频率范围窄.晃动波高峰值是储罐自振特性和地震波频谱特性等多种因素导致的结果,隔震系统设计时需特别考虑晃动波高增大的影响.  相似文献   

9.
A method for analyzing the earthquake response of elastic, cylindrical liquid storage tanks under vertical excitations is presented. The method is based on superposition of the free axisymmetrical vibrational modes obtained numerically by the finite element method. The validity of these modes has been checked analytically and the formulation of the load vector has been confirmed by a static analysis. Two forms of ground excitations have been used: step functions and recorded seismic components. The radial and axial displacements are computed and the corresponding stresses are presented. Both fixed and partly fixed tanks are considered to evaluate the effect of base fixation on tank behaviour. Finally, tank response under the simultaneous action of both vertical and lateral excitations is calculated to evaluate the relative importance of the vertical component of ground acceleration on the overall seismic behaviour of liquid storage tanks.  相似文献   

10.
The non‐stationary rocking response of liquid storage tanks under seismic base excitations including soil interaction has been developed based on the wavelet domain random vibration theory. The ground motion has been characterized through statistical functionals of wavelet coefficients of the ground acceleration history. The tank–liquid–foundation system is modelled as a multi‐degree‐of‐freedom (MDOF) system with both lateral and rocking motions of vibration of the foundation. The impulsive and convective modes of vibration of the liquid in the tank have been considered. The wavelet domain coupled dynamic equations are formulated and then solved to get the expressions of instantaneous power spectral density function (PSDF) in terms of functionals of input wavelet coefficients. The moments of the instantaneous PSDF are used to obtain the stochastic responses of the tank in the form of coefficients of hydrodynamic pressure, base shear and overturning base moment for the largest expected peak responses. Parametric variations are carried out to study the effects of various governing parameters like height of liquid in the tank, height–radius ratio of the tank, ratio of total liquid mass to mass of foundation, and shear wave velocity in the soil medium, on the responses of the tank. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

11.
立式储液罐地震破坏快速评估方法   总被引:1,自引:0,他引:1  
本文采用大型有限元程序ANSYS对立式储液罐的地震反应进行了非线性数值分析,考虑了罐体和内部液体的相互作用,得到了3个不同容积的储罐,在不同峰值的地震动时程输入下的反应结果。结合地震灾害中立式储罐的地震破坏现象和特点,以及现有的立式储罐地震破坏预测方法,提出了立式储罐的地震破坏快速评估方法。  相似文献   

12.
地震作用下立式储液罐罐壁"象足"变形仿真分析   总被引:2,自引:0,他引:2  
基于ANSYS软件建立了考虑液体晃动和罐底提离立式储液罐有限元模型,分别进行了水平地震和竖向地震作用下罐壁"象足"变形分析.分析表明:立式储液罐罐壁"象足"变形主要是由罐壁纵向压应力超过临界应力而产生的局部屈曲破坏,并非强度破坏.因罐底提离导致的罐底与基础反复撞击加大了作用在罐壁上的应力,使罐壁底部"象足"变形不断发展,最终导致罐壁撕裂.在完全相同地震加速度作用下,水平地震作用比竖向地震作用罐壁更早更容易进入屈曲状态,产生"象足"变形.  相似文献   

13.
A wavelet‐based random vibration theory has been developed for the non‐stationary seismic response of liquid storage tanks including soil interaction. The ground motion process has been characterized via estimates of statistical functionals of wavelet coefficients obtained from a single time history of ground accelerations. The tank–liquid–soil system has been modelled as a two‐degree‐of‐freedom (2‐DOF) system. The wavelet domain equations have been formulated and the wavelet coefficients of the required response state are obtained by solving two linear simultaneous algebraic equations. The explicit expression for the instantaneous power spectral density function (PSDF) in terms of the functionals of the input wavelet coefficients has been obtained. The moments of this PSDF are used to estimate the expected pseudo‐spectral acceleration (PSA) response of the tank. Parametric variations are carried out to study the effects of tank height, foundation natural frequency, shear wave velocity of soil and ratio of the mass of tank (including liquid) to the mass of foundation on the PSA responses of tanks. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

14.
地震作用下立式储液罐罐壁“象足”变形仿真分析   总被引:1,自引:0,他引:1  
基于ANSYS软件建立了考虑液体晃动和罐底提离立式储液罐有限元模型,分别进行了水平地震和竖向地震作用下罐壁“象足”变形分析。分析表明:立式储液罐罐壁“象足”变形主要是由罐壁纵向压应力超过临界应力而产生的局部屈曲破坏,并非强度破坏。因罐底提离导致的罐底与基础反复撞击加大了作用在罐壁上的应力,使罐壁底部“象足”变形不断发展,最终导致罐壁撕裂。在完全相同地震加速度作用下,水平地震作用比竖向地震作用罐壁更早更容易进入屈曲状态,产生“象足”变形。  相似文献   

15.
Damage to elevated water tanks in past earthquakes can be attributed to the poor performance of their supporting frame staging. In order to ascertain the performance of these elevated water tanks, it is crucial to categorize the damage in quantifiable damage states. Among various parameters to quantify the damage states, the top drift of frame staging can be conveniently correlated to the different damage levels. In literature, drift limits corresponding to different damage states of the frame staging of the elevated water tank are not available. In the present study, drift limits for RC frame staging in elevated water tanks corresponding to different seismic damage states have been proposed. Various damage states of the elevated water tank have been determined using the Park and Ang damage index. The Park and Ang damage index utilizes results of both pushover analysis and incremental dynamic analysis. Twelve models of elevated water tanks have been developed considering variation in staging height and tank capacity. Incremental dynamic analysis has been performed using the suite of twelve actual earthquake ground motions. Based on the regression analysis between damage indexes and drift, limiting drift values for each damage state are proposed.  相似文献   

16.
A seismological overview of long-period ground motion   总被引:1,自引:1,他引:0  
Long-period ground motion has become an increasingly important consideration because of the recent rapid increase in the number of large-scale structures, such as high-rise buildings and oil storage tanks. Large subduction-zone earthquakes and moderate to large crustal earthquakes can generate far-source long-period ground motions in distant sedimentary basins with the help of path effects. Near-fault long-period ground motions are generated, for the most part, by the source effects of forward rupture directivity. Far-source long-period ground motions consist primarily of surface waves with longer durations than near-fault long-period ground motions. They were first recognized in the seismograms of the 1968 Tokachi-oki and 1966 Parkfield earthquakes, and their identification has been applied to the 1964 Niigata earthquake and earlier earthquakes. Even if there is no seismogram, we can identify far-source long-period ground motions through the investigation of tank damage by liquid sloshing.  相似文献   

17.
This article presents a simple and effective method for generating across-fault seismic ground motions for the analysis of ordinary and seismically isolated bridges crossing strike-slip faults. Based on pulse models available in the literature, two simple loading functions are first proposed to represent the coherent (long-period) components of ground motion across strike-slip faults. The loading functions are then calibrated using actual near-fault ground-motion records with a forward-directivity velocity pulse in the fault-normal direction and a fling-step displacement in the fault-parallel direction. The effectiveness of the proposed method is demonstrated by comparing time history responses and seismic demands of ordinary and seismically isolated bridges obtained from nonlinear response history analyses using the actual ground-motion records and the calibrated loading functions. A comprehensive methodology is also presented for selecting the input parameters of the loading functions based on empirical equations and practical guidelines. Finally, an analysis procedure for bridge structures crossing strike-slip faults is introduced based on the proposed method for generating across-fault ground motions and the parameter selection methodology for the loading functions.  相似文献   

18.
浮放储罐三维地震反应有限元分析   总被引:1,自引:0,他引:1  
针对立式储罐,考虑液固耦合效应、地基与储罐结构的相互作用,采用有限元分析方法,对储罐在三维地震荷载作用下动反应进行了数值分析。分析结果表明:储罐三维地震加速度反应较一维地震加速度反应增加、提离高度明显放大、储罐轴向应力增加、基底剪力与弯矩增大。  相似文献   

19.
The seismic response of the Mexico City Cathedral built of very soft soil deposits is evaluated by using motions recorded in various parts of the structure during several moderate earthquakes. This unique set of records provides significant insight into the seismic response of this and other similar historic stone masonry structures. Free‐field ground motions are carefully compared in time and frequency domains with motions recorded at building basement. The dynamic characteristics of the structure are inferred from the earthquake records by using system identification techniques. Variation of seismic response for different seismic intensities is discussed. It is shown that, due to the soil–structure interaction, due to large differences between dominant frequencies of earthquake ground motions at the site and modal frequencies of vibration of the structure, and due to a particularly high viscous damping, seismic amplifications of ground motion in this and similar historic buildings erected on soft soil deposits are much smaller than that induced in most modern constructions. Nevertheless, earthquake records and analytical results show that several components of the structure such as its central dome and the bell towers may be subjected to local vibrations that significantly amplify ground motions. Overall, results indicate that in its present state the structure has an acceptable level of seismic safety. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
特大型液化天然气(LNG)储罐的固有频率通常介于2~10 Hz之间,处于大部分地震运动的频率范围之内。在过去的几十年中,许多事故已经证明,储罐在地震作用下很容易遭破坏。使用隔震支座来减少储罐的地震作用已经被证明是非常有效的,但对于特大型LNG储罐,其连接组件对隔震层层间位移有严格限制,尤其是在软土场地中,桩水平抗力与隔震层位移是一对矛盾,普通隔震系统会在隔震层产生较大位移,导致特大型LNG储罐连接组件的设计非常困难。因此提出了一种由环形阻尼器反力墙、粘滞阻尼器以及安装于基桩顶端的隔震支座组成的新型隔震系统,反力墙独立设置于地基中,不与桩基连接,罐底的部分剪力直接向反力墙传递。以容量为16万m3的特大型LNG储罐为例,建立多自由度集中质量简化模型,以层间位移、桩基剪力作为性能指标进行了评价分析。结果显示,新型隔震系统对特大型LNG储罐隔震层位移及桩基剪力的控制非常有效。  相似文献   