首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In recent earthquakes in developing countries, severe damage was observed on reinforced concrete buildings. This study focuses on exterior beam-column joints with substandard beam rebar anchorage and seismic strengthening by installing wing walls. First, a series of experiments was conducted to investigate the seismic behavior of exterior joints with substandard beam rebar anchorage representing typical Bangladeshi buildings. Two 0.7-scaled exterior joint specimens were tested, and these specimens showed beam rebar anchorage failure and/or joint shear failure. Prior to strengthening of the joint, a series of pullout tests was conducted on postinstalled bonded anchors in low-strength concrete for strengthening design. Then, an experiment was performed to apply the strengthening method by wing walls to one of the exterior joint specimens to improve the integrity, and this method was intended to prevent the failure of beam rebar anchorage. The strengthening method is proposed to extend the development length of beam longitudinal bars by considering the embedment length along the wing walls. The test results verified the effectiveness and applicability of the proposed strengthening method to upgrade exterior RC beam-column joints with deficient beam rebar anchorage.  相似文献   

2.
Displacement‐based seismic assessment of buildings containing unreinforced masonry (URM) walls requires as input, among others, estimates of the in‐plane drift capacity at the considered limit states. Current codes assess the drift capacity of URM walls by means of empirical models with most codes relating the drift capacity to the failure mode and wall slenderness. Comparisons with experimental results show that such relationships result in large scatter and usually do not provide satisfactory predictions. The objective of this paper is to determine trends in drift capacities of modern URM walls from 61 experimental tests and to investigate whether analytical models could lead to more reliable estimates of the displacement capacity than the currently used empirical models. A recently developed analytical model for the prediction of the ultimate drift capacity for both shear and flexure controlled URM walls is introduced and simplified into an equation that is suitable for code implementation. The approach follows the idea of plastic hinge models for reinforced concrete or steel structures. It explicitly considers the influence of crushing due to flexural or shear failure in URM walls and takes into account the effect of kinematic and static boundary conditions on the drift capacity. Finally, the performance of the analytical model is benchmarked against the test data and other empirical formulations. It shows that it yields significantly better estimates than empirical models in current codes. The paper concludes with an investigation of the sensitivity of the ultimate drift capacity to the wall geometry, static, and kinematic boundary conditions.  相似文献   

3.
高延性纤维增强水泥基复合材料(ECC)具有高强度、高延性和水硬过程中粘结性能良好,在砌体加固工程中具有广泛的应用前景。通过对2片未加固、2片单面和2片双面ECC面层加固后空斗墙进行水平拟静力试验,对比加固不同砌法下单面和双面空斗墙破坏模式、滞回曲线、刚度退化、承载能力和延性性能,进而研究ECC面层加固对墙体抗震性能的影响。利用ABAQUS有限元软件,采用预留孔洞的整体建模方式进行有限元分析,对比了试验值与计算值。结果表明:ECC面层与砖墙之间粘结较可靠,ECC面层优越的材料抗力可以抵抗墙体承担的水平剪力;单、双面ECC面层加固后空斗墙体极限变形能力及极限承载力均得到大幅提升,试件延性和抗震性能同步改善;有限元计算的水平承载力值与试验值相差不大。  相似文献   

4.
Fluctuations in axial load imposed on a rocking footing will affect its moment capacity, the shape of its moment–rotation hysteresis, and potentially the system's seismic performance. Structural asymmetry increases the likelihood of axial load variation during earthquake excitations. To investigate this issue, a unique centrifuge testing program was carried out on low‐rise frame–wall–rocking foundation systems. In this paper, the seismic behaviors of asymmetric and symmetric models from this test program are systematically compared. Experimental results reveal that placing the lateral force resisting shear wall outboard produces significant axial load fluctuation, which in turn greatly deteriorate the lateral load‐carrying capacity of a foundation rocking dominated frame–wall system, particularly in its weak direction. However, it strengthens the system when loading is towards the shear wall, leading to a highly asymmetric hysteretic response. During earthquake loading, all asymmetric rocking foundation systems observe smaller peak roof accelerations, but larger peak and permanent roof drifts compared with the symmetric systems. Despite these differences in response, the axial load fluctuation and structural asymmetry do not significantly change the relative energy dissipated by the rocking foundations and inelastic structural components within each frame–wall–rocking foundation model. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
This article presents a new mechanical model for the non‐linear force–displacement response of unreinforced masonry (URM) walls developing a flexural rocking mode including their displacement capacity. The model is based on the plane‐section hypothesis and a constitutive law for the masonry with zero tensile strength and linear elastic behaviour in compression. It is assumed that only the compressed part of the wall contributes to the stiffness of the wall and therefore the model accounts for a softening of the response due the reduction of the effective area. Stress conditions for limit states are proposed that characterise the flexural failure. The new model allows therefore linking local performance levels to global displacement capacities. The limit states criteria describe the behaviour of modern URM walls with cement mortar of normal thickness and clay bricks. The model is validated through comparison of local and global engineering demand parameters with experimental results. It provides good prediction of the effective stiffness, the force capacity and the displacement capacity of URM walls at different limit states. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
地震时砌体结构窗间墙易发生破坏,为了提高其抗震性能,对高宽比为1的2组共4片墙体,其中:2片为双层打包带加固墙体,2片为原墙,进行了拟静力试验,研究墙体的破坏形态、水平承载力、滞回曲线和耗能等抗震性能。试验发现原墙发生剪切破坏,加固后墙体发生摇摆破坏,加固改变了墙体破坏模式,加固后墙体滞回曲线饱满但有捏笼,破坏荷载、延性和耗能能力都有提高,破坏时未发生剥离,表明双层打包带加固法有效地提高了窗间墙体抗震性能,对承受较大竖向应力墙体效果更好,建议加固时要加强加固层与窗下和窗上墙体的连接。  相似文献   

7.
Displacement‐based assessment procedures require as input reliable estimates of the deformation capacity of all structural elements. For unreinforced masonry (URM) walls, current design codes specify the in‐plane deformation capacity as empirical equations of interstory drift. National codes differ with regard to the parameters that are considered in these empirical drift capacity equations, but the inhomogeneity of datasets on URM wall tests renders it difficult to validate the hypotheses with the currently available experimental data. This paper contributes to the future development of such empirical relationships by investigating the sensitivity of the drift capacity to the shear span, the aspect ratio, the axial load ratio, and the size of the wall. For this purpose, finite element models of URM walls are developed in Abaqus/Explicit and validated against a set of experimental results. The results show that the axial load ratio, the shear span, and the wall size are among the factors that influence the drift capacity the most. Empirical equations are mainly derived from test results on small walls, and the numerical results suggest that this can lead to a significant overestimation of the drift capacity for larger walls.  相似文献   

8.
Numerous non‐ductile reinforced concrete (RC) buildings with little or no shear reinforcement in beam‐column joints can be found in regions of moderate seismicity. To strengthen such substandard beam‐column joints, this study proposes a method in which RC wing walls are installed beside existing columns, which overcomes the lack of realistic strengthening methods for congested connections in RC buildings. The proposed strengthening mechanism improves the joint moment capacity by utilizing tension and compression acting on the beam–wing wall boundaries; thus, brittle joint hinging failure is prevented. Three 3/4‐scale RC exterior beam‐column joint specimens without shear reinforcement, two of which were strengthened by installing wing walls with different strengthening elements, were fabricated and tested. The test results verified the effectiveness of the proposed strengthening method and the applicability of this method to seismically substandard beam‐column joints. © 2017 The Authors. Earthquake Engineering & Structural Dynamics Published by John Wiley & Sons Ltd.  相似文献   

9.
以嵌缝胶泥作为嵌缝材料,针对不同高宽比和不同配筋率的6片墙体进行了拟静力试验,探讨了嵌筋加固砖砌体墙的破坏特征、变形能力、承载能力、耗能能力、滞回特征及刚度退化等抗震性能,建立了以试验为基础的嵌筋加固砖砌体墙的抗剪承载力计算公式。研究结果表明:高宽比为1.8的试件,嵌筋墙体较无筋墙体水平抗剪极限承载力提高了17%~31%,延性提高了54%~83%;高宽比为0.5的试件,嵌筋墙体较无筋墙体水平抗剪极限承载力提高了13%~17%,延性提高了17%~20%,嵌筋加固墙体滞回环饱满,耗能能力有较大幅度提高,破坏形式由脆性破坏转变为延性破坏,嵌筋对墙体初始刚度的影响较小,给出的抗剪承载力公式计算值与试验值接近,为工程应用奠定了基础。  相似文献   

10.
本文设计了1片普通混凝土剪力墙试件和5片混杂纤维混凝土剪力墙试件,进行低周往复加载试验,研究混杂纤维混凝土分布位置和高度对剪力墙抗震性能的影响。根据拟静力试验数据,分析了墙体试件的滞回曲线、骨架曲线及关键点、位移延性、刚度退化性能、耗能能力以及关键位置钢筋应力应变分布情况。结果表明:(1)剪力墙试件中采用混杂纤维混凝土的区域以均匀的水平裂缝为主,有效控制了剪力墙的斜裂缝的产生,最终表现出弯曲破坏模式。(2)相比混杂纤维混凝土分布在约束边缘区域,混杂纤维混凝土分布在底部的试件滞回曲线更加饱满,耗能能力更好。(3)混杂纤维混凝土分布高度越高,滞回曲线越饱满。当分布高度大于0.3h (h为全长)时,混杂纤维混凝土分布高度的提升对承载能力和变形能力的影响较小。(4)混杂纤维混凝土的掺入提高了剪力墙的抗剪性能,在一定程度上可替代水平分布筋。  相似文献   

11.
通过对采用高强钢筋的6片T形混凝土短肢剪力墙和采用高强钢筋高强混凝土的6片L形短肢剪力墙进行低周往复加载试验,研究了T形和L形的破坏形态与性能差异,分析了高厚比、轴压比、配箍间距等参数对构件破坏形态、滞回耗能、骨架曲线、延性及耗能等抗震性能的影响,对比分析了构件与普通短肢剪力墙的抗震性能差异。试验结果表明:采用腹板端部箍筋加密的方式可减轻构件端部的损伤和降低正负向加载时承载力和延性的不对称性;T形构件中高厚比为5的试件表现为弯曲破坏,其他构件表现为弯剪破坏;试验中高厚比小的构件相对于高厚比大的试件延性耗能更好,轴压比增大,构件承载力提高但延性降低;与普通短肢剪力墙相比,T形短肢剪力墙承载力和变形能力提高,耗能增加,L形短肢剪力墙承载力提高较大,极限位移增大,构件后期变形能力略有降低,但可以满足抗震性能要求。  相似文献   

12.
There are numerous studies on the behavior of Unreinforced Masonry (URM) walls in both in‐plane (IP) and out‐of‐plane (OP) directions; however, few aimed at understanding the simultaneous contribution of these intrinsic responses during earthquakes. Undoubtedly, even a strong URM wall shows weakened capacity in the OP direction because of minor cracks and other damages in the IP direction, and this capacity reduction has not yet been accounted for in seismic codes. In this study, performance of three URM walls is evaluated by several numerical analyses in terms of the OP capacity reduction because of IP displacements and failure modes. Several parameters influencing the OP capacity have been studied including aspect ratio, roof boundary condition, IP displacement and IP loading patterns. The results indicate that reduction in the OP capacity of URM walls varies from negligible to very high depending on boundary conditions, IP failure mode and IP damage severity. Moreover, IP loading pattern is more important in walls with higher aspect ratios because of their IP failure modes. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
周忠发  赵均 《地震学刊》2010,(6):660-666
运用ABAQUS分析软件,建立水平荷载作用下的钢筋混凝土核心筒有限元模型,进行非线性分析,并将分析结果与大比例试件的试验结果对比,对所采用的有限元模型加以验证。在此基础上,进行改变钢筋混凝土核心筒轴压比、高宽比和筒壁厚度的受力过程模拟分析,研究这些参数对筒体性能的影响。结果表明:随着轴压比的增大,筒体的破坏由受拉向受压破坏转变,筒体最大水平承载力经历先增加后减小的变化,延性变差;随着高宽比的增大,筒体破坏形态由剪切向弯曲破坏转变,延性增加,整体弯曲作用更加明显,最大底部剪力减小;随着壁厚的增大,试件破坏由截面压屈失稳向墙肢底部受弯破坏转变,墙肢破坏区域沿高度方向发展,耗能能力更强,承载力明显增大,变形能力显著增加。  相似文献   

14.
底部开缝预应力剪力墙结构力学性能的有限元分析   总被引:3,自引:0,他引:3  
根据现浇混凝土结构与装配混凝土结构的耗能特点,建立了底部开缝后张拉预应力摇摆剪力墙结构模型,并采用数值模拟方法研究其抗震耗能性能,分析分布钢筋、预应力水平、轴压力等参数对其力学性能的影响,并与同类型整体现浇剪力墙进行了对比分析。结果表明:底部开缝后张拉预应力摇摆剪力墙结构具有一定的耗能能力,虽然相对于现浇剪力墙结构,其承载力较低,但变形能力较强,墙体损伤和残余变形较小,并且具有较好的自复位能力。  相似文献   

15.
A simplified numerical model was used to investigate the out‐of‐plane seismic response of vertically spanning unreinforced masonry (URM) wall strips. The URM wall strips were assumed to span between two flexible diaphragms and to develop a horizontal crack above the wall mid‐height. Three degrees of freedom were used to accommodate the wall displacement at the crack height and at the diaphragm connections, and the wall dynamic stability was studied. The equations of dynamic motion were obtained using principles of rocking mechanics of rigid bodies, and the formulae were modified to include semi‐rigid wall behaviour. Parametric studies were conducted that included calculation of the wall response for different values of diaphragm stiffness, wall properties, applied overburden, wall geometry and earthquake ground motions. The results of the study suggest that stiffening the horizontal diaphragms of typical low‐rise URM buildings will amplify the out‐of‐plane acceleration demand imposed on the wall and especially on the wall–diaphragm connections. It was found that upper‐storey walls connected to two flexible diaphragms had reduced stability for applied earthquake accelerograms having dominant frequency content that was comparable with the frequency of the diaphragms. It was also found that the applied overburden reduced wall stability by reducing the allowable wall rotations. The results of this study suggest that the existing American Society of Civil Engineers recommendations for assessment of vertically spanning walls overestimate the stability of top‐storey walls in multi‐storey buildings in high‐seismic regions or for walls connected to larger period (less stiff) diaphragms. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
The present study was dedicated to investigate an effective, economical and convenient method for strengthening brick infill walls, i.e. the use of externally-bonded expanded steel plates. A total of 30 plastered wall assemblies were tested under monotonic diagonal loading to investigate the contribution of these plates to the load capacities, ductilities and rigidities of brick walls. The plate thickness, bolt spacing and location of the plates in the wall were the parameters of the test program. The experiments indicated that application of the plates on the outermost fine plaster layer significantly improves the diagonal load–deflection behaviour of infill walls and reducing the bolt spacing provides the strengthened walls with higher load capacity values. An analytical expression was developed for estimating the diagonal load capacities of plated brick walls. The analytical load estimates were found to be in close agreement with the experimental values.  相似文献   

17.
Existing unreinforced masonry buildings frequently suffer out-of-plane local collapse mechanisms when undergoing earthquake ground motion. The energy damping that occurs during the motion, due to impacts of a wall against the foundation or against other walls, is a relevant parameter on the response. An experimental investigation has been carried out to estimate the dissipation of kinetic energy that takes place during free oscillations. Restraint conditions allow for two-sided rocking (wall resting on a foundation) and one-sided rocking (wall resting on a foundation adjacent to transverse walls). Five specimens have been tested, modelling walls acted out-of-plane (fa?ades). When one-sided rocking is under consideration, different depths of the contact surface between fa?ade and transverse walls are considered. In the case of two-sided rocking, the experimental coefficient of restitution is slightly lower than the analytic coefficient. In the case of one-sided rocking, an analytic formulation is proposed and this is compared against experimental data. Although the coefficient of restitution of one-sided rocking is less than half that of two-sided rocking, it is not equal to zero. Thus, it cannot induce a sudden stop of the motion. Hence, nonlinear time history analyses performed under this assumption may prove unsafe. Moreover, a comparison has been carried out between overturning maps, induced by twenty natural accelerograms, computed for the analytic coefficient of restitution and those computed for the experimental coefficient of restitution. The increased energy dissipation reduces the frequency of overturning and causes a more regular behaviour.  相似文献   

18.
Unreinforced masonry infill walls are widely used as non-structural partitions in RC frames. The effects of infills on the structural responses are often ignored in the design process since they are generally considered as expendable elements. However, recent studies have shown that not only shear damage can be inflicted to the columns braced by the infill walls, but also that the structural stability can be jeopardised by the fall-off of the infills. This paper presents the development of new detailing methods for the infill walls, which features slit panels, isolation gaps between the infills and columns, and anchorage of the infills. The proposed detailing methods were tested and verified experimentally using shake-table tests on five 1/3-scale infilled RC frame specimens with different combinations of the features stated above. The design and construction of the shake-table test specimens have taken into account the similitude requirements. The test results indicate that the proposed detailing method effectively reduced the undesirable interaction between column and infill walls. And the use of proper anchorage could prevent the fall off of infills from the bounding frame. Furthermore, the specimens with slit infill walls displayed better seismic performances, which could be attributed to the rocking behaviour of the sub-panels with increased aspect ratios.  相似文献   

19.

This study proposes an innovative precast shear wall system, called an EVE precast hollow shear wall structure (EVE-PHSW). Precast panels in EVE-PHSW are simultaneously precast with vertical and horizontal holes. Noncontact lap splices of rebars are used in vertical joints connecting adjacent precast panels for automated prefabrication and easy in situ erection. The seismic behavior of EVE walls was examined through a series of tests on six wall specimens with aspect ratios of 1.0∼1.3. Test results showed that EVE wall specimens with inside cast-in situ concrete achieved the desired “strong bending and weak shear” and failed in shear mode. Common main diagonal cracks and brittle shear failure in squat cast-in situ walls were prevented. Inside cast-in situ concrete could significantly improve the shear strength and stiffness of EVE walls. The details of boundary elements (cast-in situ or prefabricated) and vertical joints (contiguous or spaced) had little effect on the global behavior of EVE walls. Noncontact lap splices in vertical joints could enable EVE walls to exhibit stable load-carrying capacity through extensive deformations. Evaluation on design codes revealed that both JGJ 3-2010 and ACI 318-14 provide conservative estimation of shear strength of EVE walls, and EVE walls achieved shear strength reserves comparative to cast-in situ walls. The recommended effective stiffness for cast-in situ walls in ASCE 41–17 appeared to be appropriate for EVE walls.

  相似文献   

20.
Reinforced concrete (RC) precast shear walls are extensively applied in practical engineering, owing to their fast construction speed. However, because of the transport conditions, RC precast shear walls have to be separated into small wall segments during the factory prefabrication procedure before being assembled on site. Typically, wet-type jointing methods are adopted to link the segments, which is time-consuming and results in unreliable post-pouring area strength. To overcome this problem, the novel scheme of the steel shear key (SSK) featuring steel shear panels and combined fillet and plug welding is proposed. Three RC precast shear wall specimens with different linking strength, termed as weakened SSK wall, standard SSK wall, and strengthened SSK wall, respectively, and an integrated shear wall specimen were designed. Quasi-static cyclic loading was applied to investigate the specimens' dynamic properties. The test results suggest the prefabricated wall segments equipped with SSKs showed reliable stiffness and bearing capacity and were improved in energy dissipation ability, compared with conventional shear walls. As the shear stiffness and number of equipped SSKs increased, the specimens exhibited higher strength, but their ductility and energy dissipation were slightly decreased. Most importantly, the standard SSK wall specimen could achieve satisfactory bearing capacity and deformability and is thus recommended for precast building structures. Finite element method (FEM) models were established to validate the test results, and parametric study analysis was conducted based on the coupling ratio of the SSK walls. Finally, an appropriate coupling ratio range is recommended for practical engineering applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号