首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Viscoelastic dampers are now among some of the preferred energy dissipation devices used for passive seismic response control. To evaluate the performance of structures installed with viscoelastic dampers, different analytical models have been used to characterize their dynamic force deformation characteristics. The fractional derivative models have received favorable attention as they can capture the frequency dependence of the material stiffness and damping properties observed in the tests very well. However, accurate analytical procedures are needed to calculate the response of structures with such damper models. This paper presents a modal analysis approach, similar to that used for the analysis of linear systems, for solving the equations of motion with fractional derivative terms for arbitrary forcing functions such as those caused by earthquake induced ground motions. The uncoupled modal equations still have fractional derivatives, but can be solved by numerical or analytical procedures. Both numerical and analytical procedures are formulated. These procedures are then used to calculate the dynamic response of a multi-degree of freedom shear beam structure excited by ground motions. Numerical results demonstrating the response reducing effect of viscoelastic dampers are also presented.  相似文献   

2.
The coupled lateral-vertical-rocking dynamic response of spring-viscous damper isolated structures is considered. The force-displacement relation of the viscous dampers is described by an experimentally calibrated fractional derivative viscoelasticity model. The equations of motion are derived and reduced to a form for direct solution by the discrete Fourier transform method. The validity and accuracy of the derived solution are demonstrated by comparison with shake table test results. The developed analysis procedure is employed in the seismic analysis of a recently constructed isolated structure. The analytical and experimental results demonstrate that spring-viscous damper isolation systems are capable of providing both effective seismic and vibration isolation.  相似文献   

3.
Viscoelastic (VE) dampers, with their stiffness and energy dissipation capabilities, have been widely used in civil engineering for mitigating wind-induced vibration and seismic responses of structures, thus enhancing the comfort of residents and serviceability of equipment inside. In past relevant research, most analytical models for characterizing the mechanical behavior of VE dampers were verified by comparing their predictions with performance test results from small-scale specimens, which might not adequately or conservatively represent the actual behavior of full-scale dampers, especially with regard to the ambient temperature, temperature rise, and heat convection effects. Thus, in this study, by using a high-performance testing facility with a temperature control system, full-scale VE dampers were dynamically tested with different displacement amplitudes, excitation frequencies, and ambient temperatures. By comparing the analytical predictions with the experimental results, it is demonstrated that adopting the fractional derivative method together with considering the effects of excitation frequencies, ambient temperatures, temperature rises, softening, and hardening, can reproduce the design performance of full-scale VE dampers very well.  相似文献   

4.
In conventional modal analysis procedures, usually only a few dominant modes are required to describe the dynamic behavior of multi-degrees-of-freedom buildings. The number of modes needed in the dynamic analysis depends on the higher-mode contribution to the structural response, which is called the higher-mode effect. The modal analysis approach, however, may not be directly applied to the dynamic analysis of viscoelastically damped buildings. This is because the dynamic properties of the viscoelastic dampers depend on their vibration frequency. Therefore, the structural stiffness and damping contributed from those dampers would be different for each mode. In this study, the higher-mode effect is referred to as the response difference induced by the frequency-dependent property of viscoelastic dampers at higher modes. Modal analysis procedures for buildings with viscoelastic dampers distributed proportionally and non-proportionally to the stiffness of the buildings are developed to consider the higher-mode effect. Numerical studies on shear-type viscoelastically damped building models are conducted to examine the accuracy of the proposed procedures and to investigate the significance of the higher-mode effect on their seismic response. Two damper models are used to estimate the peak damper forces in the proposed procedures. Study results reveal that the higher-mode effect is significant for long-period viscoelastically damped buildings. The higher-mode effect on base shear is less significant than on story acceleration response. Maximum difference of the seismic response usually occurs at the top story. Also, the higher-mode effect may not be reduced by decreasing the damping ratio provided by the viscoelastic dampers. For practical application, it is realized that the linear viscous damping model without considering the higher-mode effect may predict larger damper forces and hence, is on the conservative side. Supported by: Science Council, Chinese Taipei, grant no. 88-2625-2-002-006  相似文献   

5.
Viscoelastic–plastic (VEP) dampers are hybrid passive damping devices that combine the advantages of viscoelastic and hysteretic damping. This paper first formulates a semi‐analytical procedure for predicting the peak response of nonlinear SDOF systems equipped with VEP dampers, which forms the basis for the generation of Performance Spectra that can then be used for direct performance assessment and optimization of VEP damped structures. This procedure is first verified against extensive nonlinear time‐history analyses based on a Kelvin viscoelastic model of the dampers, and then against a more advanced evolutionary model that is calibrated to characterization tests of VEP damper specimens built from commercially available viscoelastic damping devices, and an adjustable friction device. The results show that the proposed procedure is sufficiently accurate for predicting the response of VEP systems without iterative dynamic analysis for preliminary design purposes. A design method based on the Performance Spectra framework is then proposed for systems equipped with passive VEP dampers and is applied to enhance the seismic response of a six‐storey steel moment frame. The numerical simulation results on the damped structure confirm the use of the Performance Spectra as a convenient and accurate platform for the optimization of VEP systems, particularly during the initial design stage. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
A series of large‐scale dynamic tests was conducted on a passively controlled five‐story steel building on the E‐Defense shaking table facility in Japan to accumulate knowledge of realistic seismic behavior of passively controlled structures. The specimen was tested by repeatedly inserting and replacing each of four damper types, that is, the buckling restrained braces, viscous dampers, oil dampers, and viscoelastic dampers. Finally, the bare steel moment frame was tested after removing all dampers. A variety of excitations was applied to the specimen, including white noise, various levels of seismic motion, and shaker excitation. System identification was implemented to extract dynamic properties of the specimen from the recorded floor acceleration data. Damping characteristics of the specimen were identified. In addition, simplified estimations of the supplemental damping ratios provided by added dampers were presented to provide insight into understanding the damping characteristics of the specimen. It is shown that damping ratios for the specimen equipped with velocity‐dependent dampers decreased obviously with the increasing order of modes, exhibiting frequency dependency. Damping ratios for the specimen equipped with oil and viscoelastic dampers remained constant regardless of vibration amplitudes, whereas those for the specimen equipped with viscous dampers increased obviously with an increase in vibration amplitudes because of the viscosity nonlinearity of the dampers. In very small‐amplitude vibrations, viscous and oil dampers provided much lower supplemental damping than the standard, whereas viscoelastic dampers could be very efficient. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
Buildings are continually subject to dynamic loads, such as wind load, seismic ground motion, and even the load from internal utility machines. The recent trend of constructing more flexible high‐rise buildings underscores the importance of including viscoelastic dampers in building designs. Viscoelastic dampers are used to control the dynamic response of a building. If the seismic design is based only on the linear response spectrum, considerable error may occur when calculating the seismic response of a building; rubber viscoelastic dampers show non‐linear hysteretic damping that is quite different from viscous damping. This study generated a non‐linear response spectrum using a non‐linear oscillator model to simulate a building with viscoelastic dampers installed. The parameters used in the non‐linear damper model were obtained experimentally from dynamic loading tests. The results show that viscoelastic dampers effectively reduce the seismic displacement response of a structure, but transmit more seismic force to the structure, which essentially increases its seismic acceleration response. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

8.
朱晓莹  吴浩  周颖 《地震工程学报》2022,44(6):1317-1324
相对传统结构,自复位墙结构在地震作用下具有更大的变形能力且几乎无残余位移,但其耗能能力较弱,需采用附加阻尼来增加整体耗能.目前,金属阻尼器已广泛用于自复位墙结构,其可显著减小结构大震下的地震响应,但小震下的位移和加速度减震效果不佳.因此,将小变形下即可耗能的黏弹性阻尼器应用于自复位墙结构中.设计一幢10层自复位墙结构,分别采用黏弹性阻尼器和 U 型金属阻尼器作为附加耗能构件,通过弹塑性时程分析对比采用两种耗能机制的结构地震响应.结果表明,黏弹性阻尼器可显著减小自复位墙结构在小震下的位移和加速度响应;U 型金属阻尼器在中震下开始耗能,在大震和巨震下,其减震效果会超越黏弹性阻尼器.因此,为进一步优化自复位墙结构在不同水准地震作用下的抗震性能,建议结合阻尼器的特点进行合理设计.  相似文献   

9.
粘弹性阻尼器连接的相邻结构非线性随机地震反应分析   总被引:7,自引:1,他引:7  
本文用随机等价线性化方法探讨了相邻结构之间用粘弹性阻尼器连接后的非线性随机地震反应,分析发现:在小震作用下,粘弹性阻尼器对相邻结构可以同时达到较好的控制效果;但是在强烈地震作用下,安装粘弹性阻尼器有可能会在减少一个结构的地震反应的同时,增大另外一个结构的地震反应。  相似文献   

10.
The primary purpose of this research is to improve the seismic response of a complex asymmetric tall structure using viscoelastic(VE) dampers. Asymmetric structures have detrimental effects on the seismic performance because such structures create abrupt changes in the stiffness or strength that may lead to undesirable stress concentrations at weak locations. Structural control devices are one of the effective ways to reduce seismic impacts, particularly in asymmetric structures. For passive vibration control of structures, VE dampers are considered among the most preferred devices for energy dissipation. Therefore, in this research, VE dampers are implemented at strategic locations in a realistic case study structure to increase the level of distributed damping without occupying significant architectural space and reducing earthquake vibrations in terms of story displacements(drifts) and other design forces. It has been concluded that the seismic response of the considered structure retrofitted with supplemental VE dampers corresponded well in controlling the displacement demands. Moreover, it has been demonstrated that seismic response in terms of interstory drifts was effectively mitigated with supplemental damping when added up to a certain level. Exceeding the supplemental damping from this level did not contribute to additional mitigation of the seismic response of the considered structure. In addition, it was found that the supplemental damping increased the total acceleration of the considered structure at all floor levels, which indicates that for irregular tall structures of this type, VE dampers were only a good retrofitting measure for earthquake induced interstory deformations and their use may not be suitable for acceleration sensitive structures. Overall, the research findings demonstrate how seismic hazards to these types of structures can be reduced by introducing additional damping into the structure.  相似文献   

11.
A long-span structure is a common type of public building, but its seismic characteristics are distinct from other types of buildings because of its long span. Calculation models considering multi-point excitation are required in the seismic analysis of long-span structures. However, correlative studies have already clearly shown that important but often overlooked errors exist in previously developed multi-point excitation calculation models. The process of establishing displacement and acceleration models for multi-point seismic analysis is reviewed. Error sources and criteria of the two models are explained using rigorous theoretical derivation. Error characteristics and distributions in multiple structural types, such as ordinary structures without dampers and damper-installed structures with concentrated damping, are also described. Modifications for multi-point excitation displacement and acceleration models, for time history and stochastic analysis, respectively, are proposed, and these modified models are used to assess errors in the conventional models. Numerical examples are solved using conventional displacement and acceleration models and two corresponding modified models. The properties, components and distribution of errors in the conventional models are demonstrated. The findings presented in this paper can provide a sound basis for the practical application of multi-point excitation calculation models in seismic analysis.  相似文献   

12.
Hysteresis steel dampers are widely used in earthquake-resistant structures, where some of them are anisotropic and capable of sustaining earthquake-induced bidirectional deformation. In this paper, a simplified analytical model is proposed for simulating the hysteretic behavior of U-shaped steel dampers with horizontal bidirectional deformation. The proposed model is composed of a series of shear springs with different nonlinear characteristics in a radial configuration, and the Menegotto–Pinto hysteresis model is employed to represent the hysteretic characteristics of the springs. The mechanical and shape-related parameters of the hysteresis model are set according to the multi-directional deformation characteristics of steel dampers. With the aim of validating the effectiveness and applicability of the analytical model, a U-shaped steel damper was used as an example. The pseudo-static hysteretic characteristics of the steel damping element were analyzed and the elasto-plastic seismic response of a curved bridge featuring a steel hysteresis device was investigated. The results showed that the proposed model is sufficiently accurate to simulate the hysteretic behavior of U-shaped steel dampers, and thus provides a practical method to assess U-shaped steel dampers through seismic response analysis.  相似文献   

13.
Guo  Wei  Wu  Jun  Hu  Yao  Li  Yunsong  Yang  T. Y. 《地震工程与工程振动(英文版)》2019,18(2):433-446
Adding dampers is a commonly adopted seismic risk mitigation strategy for modern buildings, and the corresponding design procedure of dampers has been well established by the Chinese Building Code. Even though all types of dampers are designed by the same procedure, actual seismic performance of the building may differ from one to the others. In this study, a nine-story benchmark steel building is established, and three different and typical types of dampers are designed according to the Chinese Building Code to realize structural vibration control under strong earthquake excitation. The seismic response of the prototype building equipped with a viscoelastic damper, viscous damper and buckling-restrained brace(BRB) subjected to 10 earthquake records are calculated, and Incremental Dynamic Analysis(IDA) is performed to describe progressive damage of the structure under increasing earthquake intensity. In the perspective of fragility, it shows that the viscoelastic damper has the highest collapse margin ratio(CMR), and the viscous damper provides the best drift control. Both the BRB and viscoelastic dampers can effectively reduce the floor acceleration responses in the mid-rise building.  相似文献   

14.
A reliable performance of anti‐seismic devices when the upper‐structure is subjected to strong biaxial seismic excitation is of vital importance to ensure the latter doesn't reach critical behavior. U‐shaped steel dampers are hysteretic devices used to dissipate the earthquake‐induced energy of base‐isolated structures. In the framework of performance‐based design, which is gaining more and more recognition, it is of particular importance to assess the performance of base‐isolated structures with such dampers under different intensity levels of bidirectional ground motion. To achieve this goal, an analytical model able to simulate the bidirectional displacement response of an isolation system is adopted. Incremental dynamic analysis (IDA) is used to obtain the relation between the earthquake‐induced bidirectional damage of U‐shaped steel dampers and different intensity levels of the considered records. The performance of the dampers is categorized into 5 levels delimited by 4 limit states for which fragility curves are derived. The results obtained using the bidirectional approach are quantitatively compared to those given by employing an in‐plane model (widely used in current design practices in Japan) with the purpose of assessing whether the latter provides unconservative estimates of the performance of the dampers. The main conclusion is that, for large seismic intensities, the safety margin against fracture of the dampers is significantly overestimated when an in‐plane model is adopted. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

15.
In this paper, the random response of a non-linear system comprising frequency dependent restoring force terms is examined. These terms are accurately modeled in seismic isolation and in many other applications using fractional derivatives. In this context, an efficient numerical approach for determining the time domain response of the system to an arbitrary excitation is first proposed. This approach is based on the Grunwald–Letnikov representation of a fractional derivative and on the well-known Newmark numerical integration scheme for structural dynamic problems. Next, it is shown that for the case of a stochastic excitation, in addition to the time domain solutions, a frequency domain solution can be readily determined by the method of statistical linearization. The reliability of this solution is established in a Monte Carlo simulation context using the herein adopted time domain solution scheme. Furthermore, several related parameter studies are reported.  相似文献   

16.
采用复合型铅粘弹性阻尼器对带转换层框肢剪力墙结构的某酒店进行了耗能减震设计,对耗能减震结构和钢支撑结构进行了对比分析,包括反应谱和局部非线性多遇地震作用和罕遇地震作用下的时程分析。结果表明,底部框架结构布置复合型铅粘弹性阻尼器后,在多遇和罕遇地震情况下层间位移能满足《建筑抗震设计规范》要求,并且采用耗能减震结构能优化整体结构,不会对转换层上部结构产生不利的影响,能更好地改善结构的抗震性能。  相似文献   

17.
The insertion of fluid viscous dampers in building structures is an innovative technology that can improve significantly the seismic response. These devices could be very useful also in the retrofit of existing buildings. The effect of this typology of damping system is usually identified with an equivalent supplemental damping ratio, which depends on the maximum displacement of the structure, so that iterative procedures are required. In this paper, a simplified direct assessment method for nonlinear structures equipped with nonlinear fluid viscous dampers is proposed. The method proposed in this study is composed by two steps. The first one yields the direct estimate of the supplemental damping ratio provided by nonlinear viscous dampers in presence of a linear elastic structural response. The second step extends the procedure to structures with nonlinear behavior. Both graphical and analytical approaches have been developed. The proposed method has then been verified through several applications and comparisons with nonlinear dynamic analyses. Moreover, an investigation has been performed with regard to the influence of the relations that define the damping reduction factor and the hysteretic damping. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
SSI效应对粘弹性阻尼结构减震效果的影响分析   总被引:1,自引:0,他引:1  
本文以一单跨7层框架结构为研究对象,对不同场地和地震波输入条件下的粘弹性阻尼结构进行了二维有限元时程分析,探讨了SSI(土-结构动力相互作用)效应对粘弹性阻尼结构减震效果的影响。分析结果表明:①在硬土和稍硬土地基条件下,SSI效应明显降低了结构的楼层位移峰值,若在抗震设计中对客观存在的SSI效应加以考虑,设置较少数量的阻尼器(与刚性地基假定条件下确定的阻尼器数量相比)就能使结构的实际地震位移反应满足基于刚性地基假定的地震位移控制目标;②粘弹性阻尼结构的减震效果与场地条件、输入地震动特性密切相关;③与刚性地基相比,SSI效应使粘弹性阻尼结构的减震效果明显降低,且地基越软,降低幅度越大。因此,在实际的工程设计中,应当充分考虑SSI效应,对粘弹性阻尼结构的减震控制效果进行合理的评价,并针对不同的场地条件选用合适的阻尼器类型和性能参数,才有可能达到预期的减震控制效果。  相似文献   

19.
The implementation of viscous dampers to microelectronics factories has been previously proved not to affect the micro‐vibration of the factories in operation so that the vibration‐sensitive manufacturing process will not be interfered. Therefore, a seismic retrofit strategy which employs the viscous dampers installed in between the exterior and interior structures of the ‘fab’ structure is proposed in the study. The design formulas corresponding to the proposed retrofit method are derived using the non‐proportional damping theory. Based on the study, it is found that the added damping ratio to the fab structure depends greatly on the frequency ratio of the two structures in addition to the damping coefficients of the added dampers. Outside the bandwidth of the frequency ratio in which the added damping ratio is very sensitive to the variation of the frequency ratio, the added damping ratio can be well captured using the classical damping theory. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

20.
Experimental research into the seismic performance of buildings with passive oil dampers has so far been restricted to large-scale testing of frames erected on laboratory shaking tables that ignore the foundation soil below. This simplification of the problem falls short of replicating dynamic soil-structure interaction that would occur in the field. This paper presents the first experimental attempt at utilising high gravity dynamic centrifuge testing to replicate the response of a damped building at a reduced model scale. The paper compares the dynamic response of two similar two-degree-of-freedom model sway frames, one control (bare) frame and one frame equipped with miniature oil dampers, both structures founded on shallow raft foundations in dry dense sand. The miniature oil dampers successfully mitigate floor accelerations, drifts, and storey shear forces in the damped frame with minor modification to the frame stiffness. For strong, near resonance motions, global rocking of the undamped frame associated with physical uplifting of the foundation from the soil surface and subsequent yielding of sand beneath has led to floor acceleration levels, which are comparable to those obtained in the damped building fitted with miniature oil dampers. Assessment of the instrumentation installed on the miniature oil dampers reveals a viscoelastic damper behaviour with a dependency on stroke magnitude and on velocity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号