首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
We report an approach for the accurate and reproducible measurement of boron isotope ratios in natural waters using an MC‐ICP‐MS (Neptune) after wet chemistry sample purification. The sample matrix can induce a drastic shift in the isotopic ratio by changing the mass bias. It is shown that, if no purification is carried out, the direct measurement of a seawater diluted one hundred times will induce an offset of ?7‰ in the isotopic ratio, and that, for the same concentration, the greater the atomic mass of the matrix element, the greater the bias induced. Whatever the sample, it is thus necessary to remove the matrix. We propose a method adapted to water samples allowing purification of 100 ng of boron with a direct recovery of boron in 2 ml of 3% v/v HNO3, which was our working solution. Boron from the International Atomic Energy Agency IAEA‐B1 seawater reference material and from the two groundwater reference materials IAEA‐B2 and IAEA‐B3, was chemically purified, as well as boron from the certified reference material NIST SRM 951 as a test. The reproducibility of the whole procedure (wet chemistry and MC‐ICP‐MS measurement) was ± 0.4‰ (2s). Accuracy was verified by comparison with positive‐TIMS values and with recommended values. Seawater, being homogeneous for boron isotope ratios, is presently the only natural water material that is commonly analysed for testing accuracy worldwide. We propose that the three IAEA natural waters could be used as reference samples for boron isotopes, allowing a better knowledge of their isotopic ratios, thus contributing to the certification of methods and improving the quality of the boron isotopic ratio measurements for all laboratories.  相似文献   

2.
Chromium (Cr) isotopes have been widely used in various fields of Earth and planetary sciences. However, high‐precision measurements of Cr stable isotope ratios are still challenged by difficulties in purifying Cr and organic matter interference from resin using double‐spike thermal ionisation mass spectrometry. In this study, an improved and easily operated two‐column chemical separation procedure using AG50W‐X12 (200–400 mesh) resin is introduced. This resin has a higher cross‐linking density than AG50W‐X8, and this higher density generates better separation efficiency and higher saturation. Organic matter from the resin is a common cause of inhibition of the emission of Cr during analysis by TIMS. Here, perchloric and nitric acids were utilised to eliminate organic matter interference. The Cr isotope ratios of samples with lower Cr contents could be measured precisely by TIMS. The long‐term intermediate measurement precision of δ53/52CrNIST SRM 979 for BHVO‐2 is better than ± 0.031‰ (2s) over one year. Replicated digestions and measurements of geological reference materials (OKUM, MUH‐1, JP‐1, BHVO‐1, BHVO‐2, AGV‐2 and GSP‐2) yield δ53/52CrNIST SRM 979 results ranging from ?0.129‰ to ?0.032‰. The Cr isotope ratios of geological reference materials are consistent with the δ53/52CrNIST SRM 979 values reported by previous studies, and the measurement uncertainty (± 0.031‰, 2s) is significantly improved.  相似文献   

3.
Although initial studies have demonstrated the applicability of Ni isotopes for cosmochemistry and as a potential biosignature, the Ni isotope composition of terrestrial igneous and sedimentary rocks, and ore deposits remains poorly known. Our contribution is fourfold: (a) to detail an analytical procedure for Ni isotope determination, (b) to determine the Ni isotope composition of various geological reference materials, (c) to assess the isotope composition of the Bulk Silicate Earth relative to the Ni isotope reference material NIST SRM 986 and (d) to report the range of mass‐dependent Ni isotope fractionations in magmatic rocks and ore deposits. After purification through a two‐stage chromatography procedure, Ni isotope ratios were measured by MC‐ICP‐MS and were corrected for instrumental mass bias using a double‐spike correction method. Measurement precision (two standard error of the mean) was between 0.02 and 0.04‰, and intermediate measurement precision for NIST SRM 986 was 0.05‰ (2s). Igneous‐ and mantle‐derived rocks displayed a restricted range of δ60/58Ni values between ?0.13 and +0.16‰, suggesting an average BSE composition of +0.05‰. Manganese nodules (Nod A1; P1), shale (SDO‐1), coal (CLB‐1) and a metal‐contaminated soil (NIST SRM 2711) showed positive values ranging between +0.14 and +1.06‰, whereas komatiite‐hosted Ni‐rich sulfides varied from ?0.10 to ?1.03‰.  相似文献   

4.
This study presents a high‐precision Cd isotope measurement method for soil and rock reference materials using MC‐ICP‐MS with double spike correction. The effects of molecular interferences (e.g., 109Ag1H+, 94Zr16O+, 94Mo16O+ and 70Zn40Ar+) and isobaric interferences (e.g., Pd, In and Sn) to Cd isotope measurements were quantitatively evaluated. When the measured solution has Ag/Cd ≤ 5, Zn/Cd ≤ 0.02, Mo/Cd ≤ 0.4, Zr/Cd ≤ 0.001, Pd/Cd ≤ 5 × 10?5 and In/Cd ≤ 10?3, the measured Cd isotope data were not significantly affected. The intermediate measurement precision of pure Cd solutions (BAM I012 Cd, Münster Cd and AAS Cd) was better than ± 0.05‰ (2s) for δ114/110Cd. The δ114/110Cd values of soil reference materials (NIST SRM 2709, 2709a, 2710, 2710a, 2711, 2711a and GSS‐1) relative to NIST SRM 3108 were in the range of ?0.251 to 0.632‰, the δ114/110Cd values of rock reference materials (BCR‐2, BIR‐1, BHVO‐2, W‐2, AGV‐2, GSP‐2 and COQ‐1) varied from ?0.196‰ to 0.098‰, and that of the manganese nodule (NOD‐P‐1) was 0.163 ± 0.040‰ (2s, n = 8). The large variation in Cd isotopes in soils and igneous rocks indicates that they can be more widely used to study magmatic and supergene processes.  相似文献   

5.
The continuous improvement of analytical procedures using multi‐collector technologies in ICP‐mass spectrometry has led to an increased demand for isotope standards with improved homogeneity and reduced measurement uncertainty. For magnesium, this has led to a variety of available standards with different quality levels ranging from artefact standards to isotope reference materials certified for absolute isotope ratios. This required an intercalibration of all standards and reference materials, which we present in this interlaboratory comparison study. The materials Cambridge1, DSM3, ERM‐AE143, ERM‐AE144, ERM‐AE145, IRMM‐009 and NIST SRM 980 were cross‐calibrated with expanded measurement uncertainties (95% confidence level) of less than 0.030‰ for the δ25/24Mg values and less than 0.037‰ for the δ26/24Mg values. Thus, comparability of all magnesium isotope delta (δ) measurements based on these standards and reference materials is established. Further, ERM‐AE143 anchors all magnesium δ‐scales to absolute isotope ratios and therefore establishes SI traceability, here traceability to the SI base unit mole. This applies especially to the DSM3 scale, which is proposed to be maintained. With ERM‐AE144 and ERM‐AE145, which are product and educt of a sublimation–condensation process, for the first time a set of isotope reference materials is available with a published value for the apparent triple isotope fractionation exponent θapp, the fractionation relationship ln α(25/24Mg)/ln α(26/24Mg).  相似文献   

6.
测定有机样品中元素含量和同位素时,处理样品常用的方法有干灰化法和湿法两种.目前,测定样品中Cu、Zn、Fe同位素时,多采用湿法处理样品.相对于湿法处理样品,干灰化法溶样迅速、耗酸量少,适合处理大量样品,但高温灼烧过程可能会导致样品中Cu、Zn、Fe同位素的分馏.本研究利用海州香薷植株,以湿法为基础,对干灰化法和湿法处理...  相似文献   

7.
Measurements of sulfur stable isotope ratios (34S/32S) have suffered from technical difficulties in analysing low‐S materials reducing their use despite their undeniable scientific interest. The measurement of 34S/32S ratios is a powerful tool for deciphering problems such as determining the sources of environmental pollutants, to detect adulteration, tracking the evolution of the redox state of the oceans and quantifying the role of the bacterial activity in sulfide minerals genesis. We have used a high‐precision method of sulfur isotope determination using a new type of elemental analyser based on ‘purge and trap’ technology. This new technique demonstrates the high quality of 34S/32S measurements for samples with S concentrations lower than 1% m/m. International calibrated references of diverse sulfur‐bearing materials were used to calibrate two low (< 1%) S‐bearing phosphorites used as compositional reference material for future use as isotopic references: BCR 32 and NBS 120c. δ34SCDT values of, respectively, 18.2‰ (1s = 0.3; n = 23) and 18.3‰ (1s = 0.4; n = 20) are proposed for these. Calibration of both phosphorites with international reference materials led to calculation of a mean standard error close to 0.4‰. The demonstration of a capability to reliably measure S isotope ratios in low‐S phosphate minerals or rocks opens up new fields of palaeoenvironmental reconstructions.  相似文献   

8.
The high‐precision δ60/58Ni values of twenty‐six geological reference materials, including igneous rocks, sedimentary rocks, stream sediments, soils and plants are reported. The δ60/58Ni values of all samples were determined by double‐spike MC‐ICP‐MS (Nu Plasma III). Isotope standard solution (NIST SRM 986) and geological reference materials (BHVO‐2, BCR‐2, JP‐1, PCC‐1, etc.) were used to evaluate the measurement bias and intermediate precision over a period of six months. Our results show that the intermediate precision of Ni isotope determination was 0.05‰ (2s, n = 69) for spiked NIST SRM 986 and typically 0.06‰ for actual samples, and the δ60/58Ni NIST SRM 986 values were in excellent agreement with previous studies. Eighteen high‐precision Ni isotope ratios of geological reference materials are first reported here, and their δ60/58Ni values varied from ?0.27‰ to 0.52‰, with a mean of 0.13 ± 0.34‰ (2s, n = 18). Additionally, SGR‐1b (0.56 ± 0.04‰, 2s), GSS‐1 (?0.27 ± 0.06‰, 2s), GSS‐7 (?0.11 ± 0.01‰, 2s), GSD‐10 (0.46 ± 0.06‰, 2s) and GSB‐12 (0.52 ± 0.06‰, 2s) could potentially serve as candidate reference materials for Ni isotope fractionation and comparison of Ni isotopic compositions among different laboratories.  相似文献   

9.
The lithium isotope system can be an important tracer for various geological processes, especially tracing continental weathering. The key to this application is the accurate and precise determination of lithium isotopic composition. However, some of the previously established column separation methods are not well behaved when applied to chemically diverse materials, due to the significant variations in matrix/lithium ratios in some materials. Here, we report a new dual‐column system for lithium purification to achieve accurate and precise analysis of lithium isotopic compositions using a multi‐collector inductively coupled plasma‐mass spectrometer (MC‐ICP‐MS). Compared with single‐column systems, our dual‐column system yielded a consistent elution range of the lithium‐bearing fraction (7–16 ml) for samples with a large range of lithium loads and matrix compositions, so that column re‐calibration is not required. In addition, this method achieved complete lithium recovery and low matrix interference (e.g., Na/Li ≤ 1) with a short elution time (~ 6 h, excluding evaporation), with the entire procedure completed in 1.5 days. We report high precision Li isotopic compositions in twelve chemically diverse materials including seawater, silicates, carbonates, manganese nodules and clays. New recommended Li isotopic values and associated uncertainties are presented as reference values for quality control and inter‐laboratory calibration for future research and were consistent with previously published data. However, significant lithium isotopic variances (~ 1‰) in BHVO‐2 from different batches suggest Li isotopic heterogeneity in this reference material and that Li isotopic studies using this reference material should be treated with caution.  相似文献   

10.
Magnesium Isotope Compositions of Natural Reference Materials   总被引:1,自引:0,他引:1  
This study presents a chemical protocol for the separation of Mg that is particularly adapted to alkali‐rich samples (granite, soil, plants). This protocol was based on a combination of two pre‐existing methods: transition metals were first removed from the sample using an AG‐MP1 anion‐exchange resin, followed by the separation of alkalis (Na, K) and bivalent cations (Ca2+, Mn2+ and Sr2+) using a AG50W‐X12 cation‐exchange resin. This procedure allowed Mg recovery of ~ 10 0 ± 8%. The [Σcations]/[Mg] molar ratios in all of the final Mg fractions were lower than 0.05. The Mg isotope ratios of eleven reference materials were analysed using two different MC‐ICP‐MS instruments (Isoprobe and Nu Plasma). The long‐term reproducibility, assessed by repeated measurements of Mg standard solutions and natural reference materials, was 0.14‰. The basalt (BE‐N), limestone (Cal‐S) and seawater (BCR‐403) reference materials analysed in this study yielded δ26Mg mean values of ?0.28 ± 0.08‰, ?4.37 ± 0.11‰ and ?0.89 ± 0.10‰ respectively, in agreement with published data. The two continental rocks analysed, diorite (DR‐N) and granite (GA), yielded δ26Mg mean values of ?0.50 ± 0.08‰ and ?0.75 ± 0.14‰, respectively. The weathering products, soil (TILL‐1) and river water (NIST SRM 1640), gave δ26Mg values of ?0.40 ± 0.07‰ and ?1.27 ± 0.14‰, respectively. We also present, for the first time, the Mg isotope composition of bulk plant and organic matter. Rye flour (BCR‐381), sea lettuce (Ulva lactuva) (BCR‐279), natural hairgrass (Deschampsia flexuosa) and lichen (BCR‐482) reference materials gave δ26Mg values of ?1.10 ± 0.14‰, ?0.90 ± 0.19‰, ?0.50 ± 0.22‰ and ?1.15 ± 0.27‰ respectively. Plant δ26Mg values fell within the range defined by published data for chlorophylls.  相似文献   

11.
The analytical performance of a method for Os isotope ratio measurement by double‐focusing, sector field ICP‐MS (ICP‐SFMS) was evaluated. The method is based on several optimised, concurrent processes: Os extraction from samples in hot concentrated nitric acid; separation of Os from the digest solution by the formation of volatile osmium tetroxide accelerated by continuous hydrogen peroxide addition; transport of analyte vapour by an oxygen flow into the ICP; and isotopic determination by ICP‐SFMS. Due to the very efficient utilisation of analyte (approaching 0.5‰), Os isotope ratio measurement could be performed at low pg levels. Combined with an ability to process sample sizes up to 2 g (up to 50 g if the organic matrix of biological or botanical samples is eliminated by ashing), materials with Os concentrations in the low, or even sub pg g?1 range could be determined by this method. Given that two complete digestion/distillation systems were available for interchangeable use, throughputs of up to fifteen samples per 8 hour shift could be achieved. The method precision, evaluated as the long‐term reproducibility of 187 Os/188Os ratio measurements in a commercial Os reference sample containing 0.5 ng Os, was 0.16% relative standard deviation (RSD, 1s). The method has been applied to perform replicate 187 Os/188 Os ratio measurements on a suite of fifty reference materials of various origins and matrix compositions, with Os concentrations varying from < 0.1 pg g?1 to > 100 ng g?1, yielding an average precision of 3% RSD. Though none of the materials tested are certified for Os content or Os isotope composition, comparison of the obtained data with published Os isotope information for similar sample types revealed close agreement between the two. The method can also be used for the simultaneous, semi‐quantitative determination of Os concentrations.  相似文献   

12.
The accurate and precise determination of Li isotopic composition by MC‐ICP‐MS suffers from the poor performance of traditional column chromatography. Previously established chromatographic processes cannot completely remove Na in complex geological samples, which is currently interpreted to be a result of Na breakthrough. In this study, Na breakthrough during single‐column purification was found to differ between simply artificial Na‐containing sample solutions, where a little Na residue was found, and silicate rocks, where a large amount of breakthrough occurred. A revised two‐step column purification for Li using 0.5 and 0.3 mol l?1 HCl as eluents was designed to remove the Na. This modified method achieves high‐efficiency Li purification from Na and consequently avoiding high Na/Li ratio interference for subsequent MC‐ICP‐MS analyses. The proposed method was validated by the analysis of a series of reference materials, including Li2CO3 (IRMM‐016, ‐0.10‰), basalt (BCR‐2: 2.68‰; BHVO‐2: 4.39‰), andesite (AGV‐2: 6.46‰; RGM‐2: 2.59‰), granodiorite (GSP‐2: ?0.87‰) and seawater (CASS‐5, 30.88‰). This work reports early Na appearance prior to the elution curves in chromatography and emphasises its influence for subsequent Li isotope measurement. Based on the findings, the established two‐step method would be more secure than single‐column chemistry for Li purification.  相似文献   

13.
Six tourmaline samples were investigated as potential reference materials (RMs) for boron isotope measurement by secondary ion mass spectrometry (SIMS). The tourmaline samples are chemically homogeneous and cover a compositional range of tourmaline supergroup minerals (primarily Fe, Mg and Li end‐members). Additionally, they have homogeneous boron delta values with intermediate precision values during SIMS analyses of less than 0.6‰ (2s). These samples were compared with four established tourmaline RMs, that is, schorl IAEA‐B‐4 and three Harvard tourmalines (schorl HS#112566, dravite HS#108796 and elbaite HS#98144). They were re‐evaluated for their major element and boron delta values using the same measurement procedure as the new tourmaline samples investigated. A discrepancy of about 1.5‰ in δ11B was found between the previously published reference values for established RMs and the values determined in this study. Significant instrumental mass fractionation (IMF) of up to 8‰ in δ11B was observed for schorl–dravite–elbaite solid solutions during SIMS analysis. Using the new reference values determined in this study, the IMF of the ten tourmaline samples can be modelled by a linear combination of the chemical parameters FeO + MnO, SiO2 and F. The new tourmaline RMs, together with the four established RMs, extend the boron isotope analysis of tourmaline towards the Mg‐ and Al‐rich compositional range. Consequently, the in situ boron isotope ratio of many natural tourmalines can now be determined with an uncertainty of less than 0.8‰ (2s).  相似文献   

14.
A novel preconcentration method is presented for the determination of Mo isotope ratios by multi‐collector inductively coupled plasma‐mass spectrometry (MC‐ICP‐MS) in geological samples. The method is based on the separation of Mo by extraction chromatography using N‐benzoyl‐N‐phenylhydroxylamine (BPHA) supported on a microporous acrylic ester polymeric resin (Amberlite CG‐71). By optimising the procedure, Mo could be simply and effectively separated from virtually all matrix elements with a single pass through a small volume of BPHA resin (0.5 ml). This technique for separation and enrichment of Mo is characterised by high selectivity, column efficiency and recovery (~ 100%), and low total procedural blank (~ 0.18 ng). A 100Mo‐97Mo double spike was mixed with samples before digestion and column separation, which enabled natural mass‐dependent isotopic fractionation to be determined with a measurement reproducibility of  < 0.09‰ (δ98/95Mo, 2s) by MC‐ICP‐MS. The mean δ98/95MoSRM 3134 (NIST SRM 3134 Mo reference material; Lot No. 891307) composition of the IAPSO seawater reference material measured in this study was 2.00 ± 0.03‰ (2s, n = 3), which is consistent with previously published values. The described procedure facilitated efficient and rapid Mo isotopic determination in various types of geological samples.  相似文献   

15.
Measurement of Ba isotope ratios of widely available reference materials is required for interlaboratory comparison of data. Here, we present new Ba isotope data for thirty‐four geological reference materials, including silicates, carbonates, river/marine sediments and soils. These reference materials (RMs) cover a wide range of compositions, with Ba mass fractions ranging from 6.4 to 1900 µg g?1, SiO2 from 0.62% to 90.36% m/m and MgO from 0.08% to 41.03% m/m. Accuracy and precision of our data were assessed by the analyses of duplicate samples and USGS rock RMs. Barium isotopic compositions for all RMs were in agreement with each other within uncertainty. The variation of δ138/134Ba in these RMs was up to 0.7‰. The shale reference sample, affected by a high degree of chemical weathering, had the highest δ138/134Ba (0.37 ± 0.03‰), while the stream sediment obtained from a tributary draining carbonate rocks was characterised by the lowest δ138/134Ba (?0.30 ± 0.05‰). Geochemical RMs play a fundamental role in the high‐precision and accurate determination of Ba isotopic compositions for natural samples with similar matrices. Analyses of these RMs could provide universal comparability for Ba isotope data and enable assessment of accuracy for interlaboratory data.  相似文献   

16.
Chalcopyrite is an important sulfide mineral in many types of ore deposits, but matrix‐matched chalcopyrite reference materials for microanalysis are lacking. A new natural chalcopyrite‐bearing specimen (HTS4‐6) was analysed in this study to investigate its potential as a reference material for microbeam sulfur isotope ratio measurement. Detailed textural examination and major element determination showed that the HTS4‐6 chalcopyrite grains have no growth rim or zoning. A total of 607 sulfur isotope ratio spot measurements with secondary ion mass spectrometry (SIMS) conducted on the cruciform sections, and over 120 randomly selected grains yielded highly consistent sulfur isotope ratio. The intermediate measurement precision for four measurement sessions of the 34S/32S measurement results was better than 0.39‰ (2s). Randomly selected chalcopyrite grains of HTS4‐6 were further analysed by LA‐MC‐ICP‐MS, which gave a mean δ34S value of +0.58 ± 0.38‰ (2s, n = 95). The maximum variance (expressed as intermediate precision from SIMS and LA‐MC‐ICP‐MS measurements) is not worse than 0.39‰ (the SIMS value), indicating that HTS4‐6 chalcopyrite is a potential reference material for in situ microbeam sulfur isotope measurements. The mean δ34S value determined by gas source isotope ratio mass spectrometry (GS‐IRMS) is +0.63 ± 0.16‰ (2s, n = 23), consistent with that derived by LA‐MC‐ICP‐MS, and can represent the recommended value for this potential reference material.  相似文献   

17.
This study uses MC‐ICP‐MS for the precise analysis of the stable tin isotopic composition in ore minerals of tin (cassiterite, stannite), tin metal and tin bronze. The ultimate goal is to determine the provenance of tin in ancient metal objects. We document the isotope compositions of reference materials and compare the precision of different isotope ratios and the accuracy of different procedures of mass fractionation correction. These data represent a base with which isotopic data of future studies can be directly compared. The isotopic composition of cassiterite and stannite can be determined after reduction to tin metal and bronze, respectively. Both metals readily dissolve in HCl, but while the solutions of tin metal can be directly measured, the bronze solutions must be purified with an anion exchanger. The correction of the mass bias is best performed with an internal Sb standard and an empirical regression method. A series of Sn isotope determinations on commercially available mono‐element Sn solutions as well as reference bronze materials and tin minerals show fractionations ranging from about ?0.09‰ to 0.05‰/amu. The combined analytical uncertainty (2s) was determined by replicate dissolutions of reference materials of bronze (BAM 211, IARM‐91D) and averages at about 0.005‰/amu.  相似文献   

18.
A double‐spike method in combination with MC‐ICP‐MS was applied to obtain molybdenum (Mo) mass fractions and stable isotope compositions in a suite of sedimentary silicate (marine, lake, stream, estuarine, organic‐rich sediment, shales, slate, chert) and carbonate reference materials (coral, dolomite, limestones, carbonatites), and a manganese nodule reference material, poorly characterised for stable Mo isotope compositions. The Mo contents vary between 0.076 and 364 μg g?1, with low‐Mo mass fractions (< 0.29 μg g?1) found almost exclusively in carbonates. Intermediate Mo contents (0.73–2.70 μg g?1) are reported for silicate sediments, with the exception of chert JCh‐1 (0.24 μg g?1), organic‐rich shale SGR‐1b (36.6 μg g?1) and manganese nodule NOD‐A‐1 (364 μg g?1). The Mo isotope compositions (reported as δ98Mo relative to NIST SRM 3134) range from ?1.77 to 1.03‰, with the intermediate precision varying between ± 0.01 and ± 0.12‰ (2s) for most materials. Low‐temperature carbonates show δ98Mo values ranging from 0.21 to 1.03‰ whereas δ98Mo values of ?1.77 and ?0.17‰ were obtained for carbonatites CMP‐1 and COQ‐1, respectively. Silicate materials have δ98Mo values varying from ?1.56 to 0.73‰. The range of δ98Mo values in reference materials may thus reflect the increasingly important relevance of Mo isotope investigations in the fields of palaeoceanography, weathering, sedimentation and provenance, as well as the magmatic realm.  相似文献   

19.
We present the first measurements of vanadium (V) stable isotopes for six reference materials – USGS PCC‐1, BHVO‐2, BCR‐2, BIR‐1a, GSP‐2 and AGV‐2 – plus the widely available carbonaceous chondrite Allende. We present standard addition and matrix spiking tests to assess the robustness and reproducibility of our data. Standard addition utilised an enriched 50V solution designated VISSOX (Vanadium Isotope Standard Solution OXford). We further assessed the veracity of the method by spiking collected sample matrices with the same amount of a V standard solution, whose isotopic composition was defined as 0‰. Standard addition and matrix spiking tests recorded no appreciable artificial isotope fractionation. We estimate that the best currently attainable long‐term reproducibility of stable 51V/50V isotope measurements in complex matrices is 0.15‰, which is in the same order as the reproducibility achievable with standard solutions. Finally, a large range of ~ 1.2‰ in stable V isotopic composition was documented, with ~ 0.5‰ of that variation in high temperature igneous materials alone. The range and resolving power of V stable isotopes, with respect to igneous material, compared favourably with the magnitude of fractionation reported for other non‐traditional stable isotope systems, which bodes well for the utility of this new system.  相似文献   

20.
GasBench Ⅱ-IRMS水平衡氢氧同位素分析方法研究   总被引:10,自引:5,他引:5  
考察了参考气信号强度、样品水体积和水平衡时间对水平衡氢、氧同位素组成分析的影响,建立了GasBench Ⅱ-IRMS连续流稳定同位素质谱仪、CO2-H2O平衡在线连续分析水样中氧同位素组成、疏水铂催化H2-H2O平衡在线连续分析水样中氢同位素组成的分析方法。分析实验室和标准水样,测量值在误差允许范围内与推荐值一致;实验室水标准氢同位素组成分析精度(1σ)为1‰,氧同位素组成分析精度(1σ)为0.1‰。方法能减少样品的损失,提高分析速度和稳定性。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号