首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
Effect of depth of soil stratum on estimated inelastic displacement of three typical structures, viz. a four storey building, a continuous bridge, and a tower, is studied and adequacy of the site amplification models of the current design codes and available empirical relationships is examined. The structures are assumed to be located on well-defined sites with varying bedrock depths, and effect of depth on elastic response spectrum, site amplification factor, displacement modification factor and inelastic displacement is studied, numerically, for two values of PGA. It is observed that soil depth has a significant effect on elastic as well as inelastic response of the structures; however, the effect of soil amplification on inelastic response is not as pronounced as in case of elastic response. Therefore, use of empirical site amplification models based on elastic response may be too conservative, for estimating inelastic response.  相似文献   

2.
This paper outlines a methodology to assess the seismic drift of reinforced concrete buildings with limited structural and geotechnical information. Based on the latest and the most advanced research on predicting potential near-field and far field earthquakes affecting Hong Kong, the engineering response spectra for both rock and soil sites are derived. A new step-by-step procedure for displacement-based seismic hazard assessment of building structures is proposed to determine the maximum inter-storey drift demand for reinforced concrete buildings. The primary information required for this assessment is only the depth of the soft soil above bedrock and the height of the building. This procedure is further extended to assess the maximum chord rotation angle demand for the coupling beam of coupled shear wall or frame wall structures, which may be very critical when subjected to earthquake forces. An example is provided to illustrate calibration of the assessment procedure by using actual engineering structural models.  相似文献   

3.
Studied in this paper is the inelastic seismic behaviour of asymmetric-plan buildings using the histories of base shear and torque. The first step in understanding this behaviour is to construct the base shear and torque surface (BST) for the building, which represents all combinations of shear and torque that applied statically lead to collapse of the structure. Several factors controlling the shape of this surface, such as strength eccentricity and bidirectional ground motion, are identified. Also, their effects on the building responses are studied considering several structural configurations. The results obtained show that the BST surface, in conjunction with the base-shear and torque histories, provides a useful conceptual framework for understanding the behaviour of asymmetric systems. Furthermore, using these surfaces, relevant aspects of the behaviour and design of such buildings become apparent even before dynamic analysis of the structure.  相似文献   

4.
孙静  薛小杰 《地震工程学报》2019,41(6):1665-1670
为优化绿色钢结构建筑的安全性能与环保性能,基于一40层框架-支撑钢结构建筑实例进行抗震性能与环保性能分析。根据实际建筑参数构建该绿色钢结构建筑剖面图,基于时程分析法记录不同地震波作用下建筑水平位移随时间变化情况,基于Pushover分析法分析方钢管混凝土组合异形柱在罕见地震中的基底剪力和弹塑性变形,基于对比实验方法验证其环保优越性,并得出以下结论:建筑的方钢管混凝土组合异形柱符合国家抗震性能要求,整体建筑的抗震性能随楼层的增加而减弱;与钢筋混凝土结构、砖混结构相比,钢结构能有效节约施工水电用量、降低施工噪声,是一种抗震性强、环保性能优的绿色建筑形式。  相似文献   

5.
In cities and urban areas, building structures located at close proximities inevitably interact under dynamic loading by direct pounding and indirectly through the underlying soil. Majority of the previous adjacent building pounding studies that have taken the structure–soil–structure interaction (SSSI) problem into account have used simple lumped mass–spring–dashpot models under plane strain conditions. In this research, the problem of SSSI‐included pounding problem of two adjacent symmetric in plan buildings resting on a soft soil profile excited by uniaxial earthquake loadings is investigated. To this end, a series of SSSI models considering one‐directional nonlinear impact elements between adjacent co‐planar stories and using a method for direct finite element modeling of 3D inelastic underlying soil volume has been developed to accurately study the problem. An advanced inelastic structural behavior parameter, the seismic damage index, has been considered in this study as the key nonlinear structural response of adjacent buildings. Based on the results of SSSI and fixed base case analyses presented herein, two main problems are investigated, namely, the minimum building separation distance for pounding prevention and seismic pounding effects on structural damage in adjacent buildings. The final results show that at least three times, the International Building Code 2009 minimum distance for building separation recommended value is required as a clear distance for adjacent symmetric buildings to prevent the occurrence of seismic pounding. At the International Building Code‐recommended distance, adjacent buildings experienced severe seismic pounding and therefore significant variations in storey shear forces and damage indices. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
The study of the torsional response of buildings in the inelastic range of behaviour is of great interest since the ability of structures to resist strong earthquakes mainly relies on their ductility and capacity for energy dissipation. Furthermore, an examination of the performance of structures during past earthquakes demonstrates that plan-asymmetric buildings suffered greater damage due to torsional response. The paper deals with this subject by analysing a model which idealizes a one-storey building with resisting elements oriented along two perpendicular directions. In addition to the parameters of the elastic behaviour, the inelastic system response depends on full yield capacity and plan-wise strength distribution. The influence of the criterion adopted for the design of resisting elements on local ductility demand and damage has been evaluated by parametric analysis. In particular, a comparison has been carried out between systems with equal design levels for all elements and systems with design levels dependent on the element location. For a given elastic behaviour and total capacity, the strength distributions in plan have been defined which minimize ductility demand and structural damage. Finally, based on these findings, responses from models designed according to several seismic codes have been compared.  相似文献   

7.
The collapse of the Olive View Hospital Psychiatric Day Clinic is studied using three biaxial force-deflection models to represent the columns of the building. These models are: shear collapse, elastic and inelastic. The biaxial models for shear and inelastic behaviour are new developments and are useful for non-linear structural dynamic studies. In the present study, the shear collapse model is intended to represent the actual prototype behaviour. The inelastic model, which is based on a hardening rule of plasticity, is used to study the performance of a hypothetical structure with the same storey shear capacity as the prototype but which exhibits ductile behaviour. The prototype structure had a base storey shear capacity of 25 per cent, and actually failed by shearing of all of the first floor columns. In the present study, the shear collapse model predicted this behaviour even with the El Centro accelerogram as input. This result may have far-reaching significance because many low-rise reinforced concrete buildings which were designed according to recent codes have similar storey shear capacity coefficients and column properties. According to this study, such buildings may collapse even in a moderate earthquake. In the inelastic representation, the structure was found to have a base storey shear capacity of 80 per cent when moment hinging was assumed to occur at the top and bottom of the columns. Even with this high strength capacity, the permanent offset computed from the inelastic model corresponded to a ductility factor of 5 when the Pacoima Dam accelerogram was used as input. On the basis of damage to other structures observed on the site, it seems likely that ground motion of about the Pacoima Dam intensity occurred at Olive View. From this it is concluded that a low-rise ductile frame concrete building, even with this high shear force capacity, may not prove satisfactory for hospital use when subjected to strong ground motion.  相似文献   

8.
Throughout the world, buildings are reaching the end of their design life and develop new pathologies that decrease their structural capacity. Usually the ageing process is neglected in seismic design or seismic risk assessment but may become important for older structures, especially, if they are intended to be in service even after they exceed their design life. Thus, a simplified methodology for seismic performance evaluation with consideration of performance degradation over time is presented, based on an extension of the SAC/FEMA probabilistic framework for estimating mean annual frequencies of limit state exceedance. This is applied to an example of an older three-storey asymmetric reinforced concrete building, in which corrosion has just started to propagate. The seismic performance of the structure is assessed at several successive times and the instantaneous and overall seismic risk is estimated for the near collapse limit state. The structural capacity in terms of the maximum base shear and the maximum roof displacement is shown to decrease over time. Consequently, the time-averaged mean annual frequency of violating the near-collapse limit state increases for the corroded building by about 10% in comparison to the typical case where corrosion is neglected. However, it can be magnified by almost 40% if the near-collapse limit state is related to a brittle shear failure, since corrosion significantly affects transverse reinforcement, raising important questions on the seismic safety of the existing building stock.  相似文献   

9.
This paper presents a detailed study on feasibility of un‐bonded fiber reinforced elastomeric isolator (U‐FREI) as an alternative to steel reinforced elastomeric isolator (SREI) for seismic isolation of un‐reinforced masonry buildings. Un‐reinforced masonry buildings are inherently vulnerable under seismic excitation, and U‐FREIs are used for seismic isolation of such buildings in the present study. Shake table testing of a base isolated two storey un‐reinforced masonry building model subjected to four prescribed input excitations is carried out to ascertain its effectiveness in controlling seismic response. To compare the performance of U‐FREI, same building is placed directly on the shake table without isolator, and fixed base (FB) condition is simulated by restraining the base of the building with the shake table. Dynamic response characteristic of base isolated (BI) masonry building subjected to different intensities of input earthquakes is compared with the response of the same building without base isolation system. Acceleration response amplification and peak response values of test model with and without base isolation system are compared for different intensities of table acceleration. Distribution of shear forces and moment along the height of the structure and response time histories indicates significant reduction of dynamic responses of the structure with U‐FREI system. This study clearly demonstrates the improved seismic performance of un‐reinforced masonry building model supported on U‐FREIs under the action of considered ground motions. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
The investigation reported in this paper studies the effects of soil–structure interaction (SSI) on the seismic response and damage of building–foundation systems. A simple structural model is used for conducting a parametric study using a typical record obtained in the soft soil area of Mexico City during the 1985 earthquake. Peak response parameters chosen for this study were the roof displacement relative to the base and the hysteretic energy dissipated by the simple structural model. A damage parameter is also evaluated for investigating the SSI effects on the seismic damage of buildings. The results indicate that in most cases of inelastic response, SSI effects can be evaluated considering the rigid‐base case and the SSI period. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

11.
靳晓燕 《地震工程学报》2018,40(4):678-683,697
为了提高带钢避难建筑的抗震性能,对高强度地震下带钢避难建筑实施抗震设计。设置高强度地震下带钢避难所的抗震设防要求,给出不同地震情况下地震避难所设防加速度值以及地震避难所地震影响系数最高值,通过SAP2000分析软件对带钢地震避难建筑结构实施动力弹塑性时程研究,选择合理的塑性铰参数值,通过在建筑周围设置钢支撑的策略对带钢避难建筑实施设计,分析高强度地震下的带钢避难建筑的抗震性能。实验结果说明,采用所提设计方法下的带钢避难建筑在大震情况下的反应优,延性较强,在不同地震波作用下的水平方向位移角满足抗震设防规范。  相似文献   

12.
利用等位移原则估计高层结构的非弹性地震反应(一)   总被引:2,自引:0,他引:2  
高层建筑非弹性地震反应估计是当前结构抗震研究迫切希望解决的课题。本文概略介绍了常用非弹性地震反应分析方法在高层结构分析中应用的主要问题,从而引出利用等位移原则(对于长周期体系,弹性与非弹性地震位移反应近似相等)进行高层结构非弹性地震反应估计研究的原因,并以长周期单自由度和多自由度体系弹性与非弹性地震反应之间关系的有关研究结果论述了其可行性。  相似文献   

13.
将参数化建模的方法引入减震结构的分析与设计中,通过预设目标和迭代优化计算,以天水市某高层住宅消能减震结构为例,寻找最优的阻尼器布置方案。为评估和验证该消能减震结构的抗震性能,分别采用Perform 3D和ETABS等软件分析结构在多遇和罕遇地震作用下的结构响应,分析结果表明:小震作用下,消能减震结构的楼层位移、层间位移角、楼层弯矩及楼层剪力均减小6.5%以上,达到了设计要求;大震作用下,结构框架柱、框架梁、剪力墙和阻尼器能够满足既定的性能要求,层间位移角满足规范限值,能够达到“大震不倒”的设计目标,研究结果为实际工程预设减震目标和阻尼器优化布置提供参考。  相似文献   

14.
史华 《地震工程学报》2017,39(6):1024-1028
城市所处的地震危险性环境和城市建筑物的易损性是影响复杂网络建筑物强震环境下抗毁能力的关键因素。由于现阶段对建筑物抗震抗毁能力的评定仍存在一定困难,对建筑物震害程度测评只能通过强震之后建筑物受破坏的程度进行评估,且评估结果不够精准,因此提出基于复杂网络的建筑物抗震能力的评估方法。考虑到地震中的危险性因素,以地面峰值加速度为参数对强震环境下复杂网络建筑物抗毁性进行测评和分析,在此基础上提出对复杂网络下建筑物的防震抗毁能力进行评估的相对建筑物抗震性能指数,并结合建筑物抗震能力评估标准确定其抗震能力水平;再进行仿真实验加以测量,并结合震害经验,证实该方法的有效性。  相似文献   

15.
Seismic hazard levels lower than those for design of new buildings have been permitted for seismic evaluation and retrofit of existing buildings due to the relatively short remaining lifespans. The seismic hazard reduction enables costeffective seismic evaluation and retrofit of existing buildings with limited structural capacity. The current study proposes seismic hazard reduction factors for Korea, one of low to moderate seismicity regions. The seismic hazard reduction factors are based on equal probabilities of non-exceedance within different remaining building lifespans. A validation procedure is proposed to investigate equality of seismic risk in terms of ductility-based limit states using seismic fragility assessment of nonlinear SDOF systems, of which retrofit demands are determined by the displacement coefficient method of ASCE 41-13 for different target remaining building lifespans and corresponding reduced design earthquakes. Validation result shows that the use of seismic hazard reduction factors can be permitted in conjunction with appropriate lower bounds of the remaining building lifespans.  相似文献   

16.
The accurate analysis of the seismic response of isolated structures requires incorporation of the flexibility of supporting soil.However,it is often customary to idealize the soil as rigid during the analysis of such structures.In this paper,seismic response time history analyses of base-isolated buildings modelled as linear single degree-of-freedom(SDOF) and multi degree-of-freedom(MDOF) systems with linear and nonlinear base models considering and ignoring the flexibility of supporting soil are conducted.The flexibility of supporting soil is modelled through a lumped parameter model consisting of swaying and rocking spring-dashpots.In the analysis,a large number of parametric studies for different earthquake excitations with three different peak ground acceleration(PGA) levels,different natural periods of the building models,and different shear wave velocities in the soil are considered.For the isolation system,laminated rubber bearings(LRBs) as well as high damping rubber bearings(HDRBs) are used.Responses of the isolated buildings with and without SSI are compared under different ground motions leading to the following conclusions:(1) soil flexibility may considerably influence the stiff superstructure response and may only slightly influence the response of the flexible structures;(2) the use of HDRBs for the isolation system induces higher structural peak responses with SSI compared to the system with LRBs;(3) although the peak response is affected by the incorporation of soil flexibility,it appears insensitive to the variation of shear wave velocity in the soil;(4) the response amplifications of the SDOF system become closer to unit with the increase in the natural period of the building,indicating an inverse relationship between SSI effects and natural periods for all the considered ground motions,base isolations and shear wave velocities;(5) the incorporation of SSI increases the number of significant cycles of large amplitude accelerations for all the stories,especially for earthquakes with low and moderate PGA levels;and(6) buildings with a linear LRB base-isolation system exhibit larger differences in displacement and acceleration amplifications,especially at the level of the lower stories.  相似文献   

17.
成都平原粘性土动力学参数统计分析   总被引:4,自引:3,他引:1  
成都平原地震构造环境主要受近场中强地震和外围大地震的影响。成都平原内的第四系分布广泛,主要为河流相的砂卵石层夹粘土、粉土层。这种地层在土层地震反应计算时往往会产生一个峰值,具有显著的放大作用。本文共收集了107组土动力学参数的实验资料,统计分析了粉质粘土和粘土两种粘性土的实测土动力学参数,给出了它们在不同深度的动剪切模量比和阻尼比的统计值。然后,选取1个典型钻孔,建立了土层地震反应分析模型,分别运用本文"统计值"、"十五结果"、"规范值"、"推荐值"进行地震土层反应计算,从反应谱形状、地表峰值加速度和反应谱特征周期等方面,验证了本文"统计值"的适用性和针对性,结果表明在盆地内使用"规范值"和"推荐值"时应谨慎,不然可能会对工程的抗震设防产生不利的影响。本文的"统计值"比"规范值"和"推荐值"更适用于成都平原地区,对各类工程建设的场地地震安全性评价具有一定的借鉴和参考价值。  相似文献   

18.
This paper presents a simplified method of evaluating the seismic performance of buildings. The proposed method is based on the transformation of a multiple degree of freedom (MDOF) system to an equivalent single degree of freedom (SDOF) system using a simple and intuitive process. The proposed method is intended for evaluating the seismic performance of the buildings at the intermediate stages in design, while a rigorous method would be applied to the final design. The performance of the method is evaluated using a series of buildings which are assumed to be located in Victoria in western Canada, and designed based on the upcoming version of the National Building Code of Canada which is due to be published in 2005. To resist lateral loads, some of these buildings contain reinforced concrete moment resisting frames,while others contain reinforced concrete shear walls. Each building model has been subjected to a set of site-specific seismic spectrum compatible ground motion records, and the response has been determined using the proposed method and the general method for MDOF systems. The results from the study indicate that the proposed method can serve as a useful tool for evaluation of seismic performance of buildings, and carrying out performance based design.  相似文献   

19.
In this study, the multi‐intensity seismic response of code‐designed conventional and base‐isolated steel frame buildings is evaluated using nonlinear response history analysis. The results of hazard and structural response analysis for three‐story braced‐frame buildings are presented in this paper. Three‐dimensional models for both buildings are created and seismic response is assessed for three scenario earthquakes. The response history analysis results indicate that the design objectives are met and the performance of the isolated building is superior to the conventional building in the design event. For the Maximum Considered Earthquake, isolation leads to reductions in story drifts and floor accelerations relative to the conventional building. However, the extremely high displacement demands of the isolation system could not be accommodated under normal circumstances, and creative approaches should be developed to control displacements in the MCE. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
The seismic performance of tuned mass dampers (TMDs) on structures undergoing inelastic deformations may largely depend on the ground motion intensity. By estimating the impact of each seismic intensity on the overall cost of future seismic damages, lifecycle cost (LCC) proves a rational metric for evaluating the benefits of TMDs on inelastic structures. However, no incorporation of this metric into an optimization framework is reported yet. This paper presents a methodology for the LCC‐optimal design of TMDs on inelastic structures, which minimizes the total seismic LCC of the combined building‐TMD system. Its distinctive features are the assumption of a mass‐proportional TMD cost model, the adoption of an iterative suboptimization procedure, and the initialization of the TMD frequency and damping ratios according to a conventional linear TMD design technique. The methodology is applied to the seismic improvement of the SAC‐LA benchmark buildings, taken as representative of standard steel moment‐resisting frame office buildings in LA, California. Results show that, despite their limited performance at the highest intensity levels, LCC‐optimal TMDs considerably reduce the total LCC, to an extent that depends on both the building vulnerability and the TMD unit cost. They systematically present large mass ratios (around 10%) and frequency and damping ratios close to their respective linearly designed optima. Simulations reveal the effectiveness of the proposed design methodology and the importance of adopting a nonlinear model to correctly evaluate the cost‐effectiveness of TMDs on ordinary structures in highly seismic areas.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号