首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Static and dynamic lateral load tests were carried out on model aluminium single piles embedded in soft clay to study its bending behaviour. Model aluminium piles with length to diameter ratios of 10, 20, 30 and 40 were used. Static lateral load tests were conducted on piles by rope and pulley arrangement upto failure and load–deflection curves were obtained. Dynamic lateral load tests were carried out for different magnitudes of load ranging from 7 to 30 N at wide range of frequencies from 2 to 50 Hz. The load transferred to the pile, pile head displacement and the strain variation along the pile length were measured using a Data Acquisition System. Safe static lateral load capacity for all piles is interpreted from load–deflection curves. Dynamic characteristics of the soil–pile system were arrived from the acquired experimental data. The soil–pile system behaves predominantly in nonlinear fashion even at low frequency under dynamic load. The displacement amplitude under dynamic load is magnified by 4.5–6.5 times the static deflection for all piles embedded in soft clay. But, the peak magnification factor reduces with an increase in the magnitude of lateral load mainly because of increase of hysteretic damping at very soft consistency. The maximum BM occurs at the fundamental frequency of the soil–pile system. Even the lower part of the pile affects the pile head response to the inertial load applied at the pile head. The maximum dynamic BM is magnified by about 1.5 times the maximum static BM for model piles in tested consistency of clay. The maximum dynamic BM occurs at a depth of about 1.5 times the depth of maximum static BM for model piles, which indicates an increase of active pile length under dynamic load.  相似文献   

2.
Presented in this paper are results of two centrifuge tests on single piles installed in unimproved and improved soft clay (a total of 14 piles), with the relative pile–soil stiffness values varying nearly two orders of magnitude, and subjected to cyclic lateral loading and seismic loading. This research was motivated by the need for better understanding of lateral load behavior of piles in soft clays that are improved using cement deep soil mixing (CDSM). Cyclic test results showed that improving the ground around a pile foundation using CDSM is an effective way to improve the lateral load behavior of that foundation. Depending on the extent of ground improvement, elastic lateral stiffness and ultimate resistance of a pile foundation in improved soil increased by 2–8 times and 4–5 times, respectively, from those of a pile in the unimproved soil. While maximum bending moments and shear forces within piles in unimproved soil occurred at larger depths, those in improved soil occurred at much shallower depths and within the improved zone. The seismic tests revealed that, in general, ground improvement around a pile is an effective method to reduce accelerations and dynamic lateral displacements during earthquakes, provided that the ground is improved at least to a size of 13D × 13D × 9D (length × width × depth), where D is the outside diameter of the pile, for the pile–soil systems tested in this study. The smallest ground improvement used in these tests (9D × 9D × 6D), however, proved ineffective in improving the seismic behavior of the piles. The ground improvement around a pile reduces the fundamental period of the pile–soil system, and therefore, the improved system may produce larger pile top accelerations and/or displacements than the unimproved system depending on the frequency content of the earthquake motion.  相似文献   

3.
Dynamic experiments were carried out on instrumented model aluminium single piles embedded in clay of different consistencies to study its bending behaviour under lateral loads. Piles with different length to diameter ratios were used. Dynamic lateral load of different magnitudes ranging from 7 to 30 N at wide range of frequencies from 2 to 50 Hz were applied. The load transferred to the pile, pile head displacement and the strain variation along the pile length were measured using a dedicated data acquisition system. Static lateral load tests were also performed to investigate the magnification of dynamic response of piles in clay. It is found that the maximum bending moment due to dynamic load is magnified by about 1.5–4 times in comparison to the static load for short piles but about 9 times for long piles. Depth of fixity and effective pile length is also largely amplified under dynamic loads, thus indicating that a pile which behaves as a flexible pile under static load, may not exhibit flexible behaviour under dynamic load.  相似文献   

4.
为了研究软岩地基桥桩的荷载传递性状、破坏机理,并获取在该地质条件下更为可靠的桩基计算参数,对秦巴山区软岩地基3根钻孔灌注试桩进行竖向静载试验。结果表明:秦巴山区软岩地基桥桩试桩荷载沉降曲线呈陡降型,实测竖向极限承载力为20 500kN,桩的破坏方式为桩身材料强度破坏;淤泥质亚黏土地层中的碎石起到一定的骨架作用,增强了此地层桩极限侧阻力,发挥极限侧阻力所需的桩土(岩)相对位移为4~8mm;强风化砾岩表现为加工软化型,发挥极限侧阻力所需的桩土(岩)相对位移为3~8mm;中风化砂砾岩表现为明显的加工硬化型,所需的桩岩相对位移大,且桩极限侧阻力的特征点不明显;淤泥质亚黏土地层桩侧阻力占总荷载的60%~70%,随着桩顶荷载的逐步加大,该地层桩侧阻力所占比例不断下降,而嵌岩段桩侧阻力所占比例逐渐上升,达到55%~65%,嵌岩段桩侧阻力沿桩深的分布曲线表现出非线性的特征;试桩为端承摩擦桩,桩端阻力约占桩顶荷载的20%左右,且未充分发挥,在上部结构允许的沉降范围内,适当增加桩端的沉降有利于端阻力的发挥;桩侧阻力先于端阻力发挥,建议单桩承载力设计时分别采用不同的端阻力和侧阻力安全系数。  相似文献   

5.
The influence of vertical loads on the lateral response of group piles installed in sandy soil and connected together by a concrete cap is studied through finite elements analyses. The analyses focus on the five piles in the middle row of 3 × 5 pile groups. The vertical load is applied by enforcing a vertical displacement equivalent to 2% of the pile diameter through the pile cap prior to the application of the lateral loads. The results have shown that the lateral resistance of the leading pile (pile 1) does not appear to vary considerably with the vertical load. However, the vertical load leads to 23%, 36%, 64%, and 82% increase in the lateral resistance of piles 2–5, respectively. The increase in the lateral pressures in the sand deposit is the major driving factor to contribute the change in the lateral resistance of piles, depending on the position of the pile in the group. The distribution of lateral loads among piles in the group tends to be more uniform when vertical loads were considered leading to a more economical pile foundation design.  相似文献   

6.
黄俊杰  王薇  苏谦  李婷  王迅 《岩土力学》2018,39(5):1653-1661
为了分析素混凝土桩复合地基支承路堤沉降变形特征和失稳破坏机制,建立了3组不同桩间距的素混凝土桩复合地基支承路堤离心试验模型及其数值模型。结果表明:在路堤填土自重、轨道和车辆荷载作用下,改变桩间距对素混凝土桩复合地基支承路堤沉降变形、桩体应变、加筋垫层和桩体破坏模式具有显著的影响;当桩间距不大于4倍桩径时,加筋垫层整体基本保持完好,路堤下素混凝土桩复合地基沉降能逐渐趋于稳定,而桩间距达到6倍桩径后,桩顶刺穿加筋垫层,加筋垫层对桩土变形协调和传递荷载作用失效,素混凝土桩复合地基支承路堤沉降持续增大;当桩间距达到4倍桩径时,素混凝土桩最大应变值发生随上部荷载的增大反而减小的突变现象,最靠近坡脚的素混凝土桩最先产生弯曲破坏而不是剪切破坏,当桩间距增大至6倍桩径时,桩体弯曲破坏逐渐往路堤中心方向发展。  相似文献   

7.
A total of 27 piles were installed at the Engineering and Physical Science Research Council soft clay test site at Bothkennar, Scotland using the continuous-flight-auger boring technique. Twelve of the piles of different lengths and diameters were tested in axial compression, using the others as reaction piles. Various testing programmes were employed to investigate relationships between axial load, movement and rate of movement. Strain measurements were facilitated by installing exten"someters in the piles, thus enabling the distributions of load and shaft resistance down each pile to be evaluated. Shaft resistances were found to be approximately constant even though the clay is known to increase in strength with depth. Peak shaft resistances were found to be dependent on rate of movement while ultimate shaft resistances were dependent only on magnitude of movement.  相似文献   

8.
The plastic tube cast-in-place concrete pile (TC pile) with a small diameter consists of pre-driven plastic tube filled with concrete. Based on the case of TC pile-reinforced embankment on soft ground, and according to the monitoring data of the TC pile-reinforced embankment system, the treatment effect and reinforcement characteristics for this system were analyzed. The field monitoring results indicates that the critical height of embankment is about 1.1 times the pile net spacing, and the small-spacing arranged TC piles can be applied to low embankment engineering; the load share rate can reflect the degree of soil arching more better and steadily and exceeds 70 % at the end of monitoring period; the settlements of pile cap and soil between piles mainly occurs in the embankment construction period; the different settlement between pile cap and soil approaches the maximum and then reduces gradually when the embankment height is about 2.2 times the pile net spacing. The variation of layered settlement and pore water pressure illustrates that the embankment settlement is mainly caused by the compression of soils within pile length, which is about 90 % of the total settlement; the influence depth of pore water pressure is about 1/3 pile length.  相似文献   

9.
The plugging of pipe piles is an important phenomenon, which is not adequately accounted for in the current design recommendations. An open-ended pipe pile is said to be plugged when the soil inside the pile moves down with the pile, resulting in the pile becoming effectively closed-ended. Plugging is believed to result in an increase in the horizontal stresses between the pile and the surrounding soil, which results in an increase in skin friction. A total number of 60 model pile tests are carried out to investigate the behavior of plugs on the pile load capacity and the effects of plug removal. Different parameters are considered, such as pile diameter–to–length ratio, types of installation in sands of different densities, and removal of the plug in three stages (50, 75, and 100 %) with respect to the length of plug. The changes in the soil plug length and incremental filling ratio (IFR) with the penetration depth during pile driving show that the open-ended piles are partially plugged from the outset of the pile driving. The pile reached a fully plugged state for pressed piles in loose and medium sand and partially plugged (IFR = 10 %) in dense sand. For driven piles, the IFR is about 30 % in loose sand, 20 % in medium sand, and 30 % in dense sand. The pile load capacity increases with increases in the length of the plug length ratio (PLR). The rate of increase in the value of the pile load capacity with PLR is greater in dense sand than in medium and loose sand. Based on test results, new empirical relation for the estimation of the load carrying capacity of open-ended piles based on the IFR is proposed.  相似文献   

10.
大厚度黄土地基中大直径长桩、超长桩的应用急剧增多,但黄土地基中超长桩的承载变形机理、侧阻和端阻的发挥性状与普通桩差别较大。采用研制的黄土相似材料填筑模型,分别进行超长单桩和群桩竖向抗压静载试验,分析桩顶荷载作用下荷载-沉降、桩身轴力、桩侧阻力、桩端土体塑性区发展变化规律。研究结果表明:超长单桩在竖向荷载作用下,荷载主要由桩侧阻力承担,桩侧阻力由上向下逐步发挥,属纯摩擦桩,单桩破坏形式为刺入破坏,桩端土体塑性变形影响范围约为1.1 d。与单桩相比,超长群桩基础桩端承载力有较大幅度的提高,桩身轴力衰减深度范围有所减小,侧阻力沿桩身逐渐增大,桩端土层的影响范围约为1.25 d,与超长单桩的影响范围较为接近。本文的研究方法和结果可为大厚度黄土地区超长桩基的承载特性研究提供参考。  相似文献   

11.
A three-dimensional finite-element analysis was carried out using ABAQUS to evaluate the squeezing effects of a prestressed high-strength concrete (PHC) pipe pile, including land upheaval, lateral soil displacement, and soil stress field with depth-varying during pile-sinking. Field data used in the analysis were obtained from the settlement building project in Hefei City, Anhui Province, China. In coastal areas of China, PHC pipe piles are normally used for reinforcement of soft foundation. The changes of displacement with the increase of soil depth and radial distance during pile-sinking are simulated for both soft foundation and soft clay with an underlying gravel layer. The numerical simulation results show that there is little difference in land upheaval with soil depth during pile-sinking, and the obvious land upheaval occurs within 0.8 m from the center of the pile. The lateral soil displacement is evident within the area of 1.0 m from the axis of the PHC, decreases with the increase of radial distance during pile-sinking, and becomes negligible beyond 4.0 m. The existence of the gravel layer helps reduce soil squeezing substantially, and the soil squeezing effects during pile-sinking have less influence on the surrounding area of foundation with a gravel layer than that in a soft foundation soil without gravel layer.  相似文献   

12.
In the present study, the end bearing capacity of screw and straight pipe pile under similar pile tip area and ground conditions were investigated. The effect of increasing overburden pressure was also considered in this research. Pile load tests on close-ended screw and straight pipe piles were conducted in the small scale. Dry Toyoura sand was used to develop the model ground. The sand was compacted at relative density of 70, 80 and 92 %. It was observed that in case of straight pipe pile, load settlement curve plunges downward without increase in load around settlement equals to 10 % of pile tip diameter, whereas in case of screw pile, the load settlement curve plunges around settlement equals to 15 % of pile tip diameter. Moreover, the screw piles having helix-to-shaft diameter ratio 2–4.1 showed 2–12 times higher end bearing capacity than straight pipe piles with similar pile shaft diameter. It was also observed from the test results that the end bearing capacity of single-helix screw pile was in average 16.25 % less than straight pipe pile with similar pile tip area and ground conditions irrespective of the effect of increasing overburden pressure.  相似文献   

13.
This paper presents both experimental study and numerical simulation to investigate the effects of an innovative sacrificial piles concept to reduce local scour surrounding service piles. These sacrificial piles are placed upstream of the pile groups, which serves to change the flow field and reduce the erosive force before it reaches the service piles. Four types of pile group arrangements were considered in the experimental and simulation analyses, including single pile, double pile in tandem arrangements, double pile with side-by-side arrangements, and pile array of 2 × 2 arrangements. Scaled experiments were conducted in flume for each group of design, and local scour around piles with and without sacrificial piles was monitored. It was found that the sacrificial piles effectively reduced the development of local scour surrounding the service piles, especially at their heels. The results also showed that the use of sacrificial piles reduced the time required for the scour depth to reach the equilibrium conditions than those without the sacrificial piles. To corroborate the experimental observation, numerical simulation with three-dimensional computational fluid dynamics model has also been carried out with commercial code with verified erosion model. The development of dynamic scour process and maximum scour depth were obtained by the computational simulations. Comparison of experimental and computational results both indicates that the use of sacrificial pile is effective in reducing the scour depth. The extent of reduction in the maximum scour depth varied with the arrangement of sacrificial piles.  相似文献   

14.
牛富生  许建聪  马亢 《岩土力学》2014,35(7):1899-1906
结合某黄土斜坡桥梁桩基工程,对同一坡度相近位置的两根桩基开展现场试验,研究其在不同竖向荷载工况下的桩身上、下坡面两侧的轴力、桩侧摩阻力及桩侧土压力的传递规律与分布特征。试验表明:桩基荷载传递具有明显的区域性,第1区域是从桩顶至约3倍桩径深度处,此区域上坡面桩侧轴力较下坡面相应位置小,且其轴力随深度递减幅度及侧摩阻力发挥程度均较下坡面桩侧大;第2区域是从约3倍桩径至10倍桩径深度处,桩身上坡面一侧竖向受力减小幅度小于桩基下坡面一侧,但此时下坡面桩侧摩阻力发挥幅度大于桩基上坡面一侧;第3区域是从约10倍桩径直至桩端,该区桩身两侧轴力差异不大,摩阻力发挥幅度相近,荷载平衡协调且向下传递稳定。针对斜坡桥梁桩基上、下坡面两侧所受土压力的不均匀性,对设计桩基竖向承载力进行了一定程度地折减,并对计算公式作了相应修正,研究结论可供类似工程参考、借鉴。  相似文献   

15.
An analysis of axially and torsionally loaded piles is presented in which the pile is treated as an elastic bar supported on two series of interacting non-linear axial and torsional springs. The characteristics of these springs depend on the soil properties and the diameter of the pile as well as on the interaction between the axial and torsional response. Predicted pile responses are compared to the results of model tests conducted on piles installed in a soft clay bed and loaded with combined axial and torsional loads. Both experimental results and theoretical predictions show that a torque applied to the pile head affects significantly the settlement and the axial bearing capacity of the pile.  相似文献   

16.
Although the loads applied on piles are usually a combination of both vertical and lateral loads, very limited experimental research has been done on the response of pile groups subjected to combined loads. Due to pile–soil–pile interaction in pile groups, the response of a pile group may differ substantially from that of a single pile. This difference depends on soil state and pile spacing. This paper presents results of experiments designed to investigate pile interaction effects on the response of pile groups subjected to both axial and lateral loads. The experiments were load tests performed on model pile groups (2 × 2 pile groups) in calibration chamber sand samples. The model piles were driven into the sand samples prepared with different relative densities using a sand pluviator. The combined load tests were performed on the model pile groups subjected to different axial load levels, i.e., 0 (pure lateral loading), 25, 50, and 75% of the ultimate axial load capacity of the pile groups, defined as the load corresponding to a settlement of 10% of the model pile diameter. The combined load test results showed that the bending moment and lateral deflection at the head of the piles increased substantially for tests performed in the presence of axial loads, suggesting that the presence of axial loads on groups of piles driven in sand is detrimental to their lateral capacity.  相似文献   

17.
The laboratory model tests and numerical analyses have been performed on reinforced granular piles installed in very soft clay. The granular piles were reinforced with geosynthetic in the form of vertical encasement, horizontal strips and combined vertical-horizontal reinforcement. The short term-displacement control model tests were carried out either only a granular pile loaded or with an entire area loaded. The laboratory results in the form of vertical load intensity-settlement behaviour were compared with that obtained from FEM software, PLAXIS 3D. The results indicated significant improvement in ultimate load intensity and stiffness of treated ground due to inclusion of geosynthetic.  相似文献   

18.
为探讨在粉土及粉质黏土中桩端阻力随贯入深度的变化规律,通过在试验桩P1的桩端安装轮辐压力传感器,以及在试验桩P1、P2距桩端200 mm处安装光纤光栅(FBG)传感器,采用两种不同的测试技术全程监测了两根闭口预应力高强度混凝土(PHC)管桩现场贯入过程中的桩端阻力。试验结果表明:桩端阻力与土层的变化密切相关,土层越硬,桩端阻力越大,当桩端从粉质黏土层进入粉土层时,桩端阻力明显增大,粉土中的桩端阻力达到粉质黏土层的2倍;整个贯入过程中,同一土层不同位置的差异性对桩端阻力也存在较大影响,在距离地面1.50 m处,P1和P2桩FBG传感器桩端阻力的差值达到了89.29 kN,而在距离地面3.50~4.50 m处,两桩的桩端阻力则相差较小。  相似文献   

19.
我国长江中下游沿岸地基中分布有较厚的砂土层,砂土层是桩基的良好持力层。该地区砂性土埋藏浅,厚度大,往往夹杂粉土或粉质黏土,一般随深度增大,砂土变密实。已有研究成果中,针对桩身穿过多层砂土条件下桩基承载力的研究较少。砂土地基中打入桩试验结果表明,砂性土的状态对打入式预制桩的施工产生很大的影响,在松散或稍密的砂性土中沉桩一般比较容易,而在中密或密实的砂性土中则较为困难。本文通过某电厂工程灌注桩现场静载试验,研究了砂土地基中桩身沉降随荷载变化规律,分析了桩身轴力随地层深度变化特征及不同土层的桩侧摩阻力。设计钻孔灌注桩桩径为800mm,桩长为47.2m,桩身混凝土强度等级为C35,桩身穿过9层土层,由现场3根桩静载试桩结果可知,荷载与沉降关系呈非线性,Q-s曲线分为弹性阶段、弹塑性阶段和整体破坏3个阶段, 15m深度以下的粉细砂层侧摩阻力对桩身轴力影响较大, 15m以上粉质黏土和淤泥质土对桩轴力影响较小。根据Q-s曲线确定单桩极限载荷约为4800~5400kN,平均值为5201kN,可满足设计要求,地基中下部砂土层承载力较大,砂土侧摩阻力大于黏性土的侧摩阻力,最大可达到70kPa。所得结论可为该类地基进一步的理论研究及工程设计提供有益的参考。  相似文献   

20.
软黏土中PHC管桩打入过程中土塞效应研究   总被引:1,自引:1,他引:0  
谢永健  王怀忠  朱合华 《岩土力学》2009,30(6):1671-1675
当开口管桩打入土层中,土体进入桩内形成土塞,土塞效应对桩的打入特性和承载能力具有重要影响。基于上海典型软土地基中长PHC桩的现场试验,统计分析3个不同场地共44根桩打桩过程中的土塞数据,探讨软土地基中PHC桩打桩过程中土塞长度与内径之比、土塞增量与桩打入深度增量之比(IFR)随打入桩长与内径之比变化的规律,并线性拟合出土塞增量与桩打入深度增量之比与土塞高度和桩打入深度之比(PLR)的经验公式。研究表明,大部分PHC桩在打桩过程中,土塞部分闭塞,桩从浅部较硬土层打入较软土层,IFR值减小,土塞闭塞作用大;桩从较软土层打入深部较硬土层,IFR值逐渐增大,土塞闭塞作用小,且土塞长度增量与桩打入深度增量之比与土塞长度与桩打入深度之比基本呈线性关系。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号