首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 921 毫秒
1.
Halogen contents for the widely distributed reference glasses BHVO‐2G, BIR‐1G, BCR‐2G, GSD‐1G, GSE‐1G, NIST SRM 610 and NIST SRM 612 were investigated by pyrohydrolysis combined with ion chromatography, total reflection X‐ray fluorescence analysis, instrumental neutron activation analysis, the noble gas method, electron probe microanalysis and laser ablation‐inductively coupled plasma‐mass spectrometry. Glasses BHVO‐2G, GSD‐1G and GSE‐1G have halogen contents that can be reproduced at the 15% level by all bulk techniques and cover a significant range in halogen mass fractions for F (~ 20–300 μg g?1), Cl (~ 70–1220 μg g?1) and Br (~ 0.2–285 μg g?1) and I (~ 9–3560 ng g?1). The BIR‐1G glass has low F (< 15 μg g?1), Cl (~ 20 μg g?1), Br (15 ng g?1) and I (3 ng g?1). The halogen contents for the silica‐rich NIST SRM 610 and 612 glasses were poorly reproduced by the different techniques. The relatively high Cl, Br and I abundances in glasses GSD‐1G and GSE‐1G mean that these glasses are well suited for calibrating spatially resolved micro‐analytical studies on silicate glasses, melt and fluid inclusions. Combined EPMA and laser ablation‐inductively coupled plasma‐mass spectrometry data for glass GSE‐1G demonstrate homogeneity at the 10% level for Cl and Br.  相似文献   

2.
The lack of analytical techniques for halogens in geological materials is mainly due to the loss of analytes during sample preparation. This study describes a rapid bulk rock digestion method (NH4F digestion) for determination of the abundances of Cl, Br and I in geological materials by SF-ICP-MS. During high temperature (200–240 °C) digestion, NH3 released from the decomposition of molten NH4F can effectively prevent the loss of halogens released from geological samples. Chlorine, Br and I were not lost during NH4F digestion at 220 °C for 0.25–6 h. The limits of quantitation for NH4F digestion were 2.8, 0.018 and 0.003 μg g-1 Cl, Br and I, respectively. Most results for halogens in geological reference materials by NH4F digestion were in agreement with their certified values, confirming that the high-performance rapid bulk rock NH4F digestion has sufficient digestion capability to extract Cl, Br and I from rocks, sediments and soils. In comparison, results obtained following acid digestion showed that HNO3 + HF digestion could effectively extract Br and I from soil and sediment samples, and that HNO3 acid digestion is only suitable to use for the determination of Br and I in soil samples.  相似文献   

3.
A method for the determination of total sulfur in geological materials by inductively coupled plasma‐optical emission spectrometry (ICP‐OES) is described. We show that good results were obtained using this method even for sample types with very low (< 20 μg g?1) sulfur concentration (e.g., peridotite). Sulfur was determined in fifteen geological reference materials with different sulfur contents. For reference materials with certified sulfur contents, the ICP‐OES method gave results in excellent agreement with certified values, and uncertainties better than 4% RSD. ICP‐OES results for sulfur in other reference materials yielded RSDs better than 10%, where S concentrations were > 100 μg g?1 (except for diabase W‐2a, 16% RSD). Reference materials with lower sulfur contents (< 40 μg g?1) showed much higher RSDs (17–18%). Except for RMs with certified values for sulfur, most data obtained by the combustion infrared detection method generally showed higher concentrations than those measured by ICP‐OES and a better RSD (≤ 8% for all materials except DTS‐2b).  相似文献   

4.
This article presents new boron concentrations for nine geochemical reference materials (GS‐N, FK‐N, GL‐O, BX‐N, DT‐N, AN‐G, GH, Mica‐Fe, Mica‐Mg). After extraction by a modified pyrohydrolysis technique, boron concentrations were measured by ICP‐MS. The blank levels for the whole procedure were 0.091 ± 0.020 ng ml?1 or 14 ± 5 ng of boron in total. The method was first validated by measuring nine reference materials with known boron concentrations. The determined boron concentrations are all within the range of recommended or published values, which means that the yields were 100%, and show precisions below 10% for samples containing over 2 μg g?1 of boron.  相似文献   

5.
Fluorine, chlorine, bromine, iodine and sulfur were determined in seventeen geological reference materials after extraction by pyrohydrolysis. Fluorine, Cl and S (as sulfate ions) were determined in the extraction solution by ion chromatography with detection limits of around 0.2 mg l−1. Bromine and I were measured by ICP-MS with detection limits of 1 μg l−1 for Br and 0.1 μg l−1 for I. For rock samples, using normal extraction conditions (500 mg of sample and 100 ml of final solution) detection limits were 40 mg kg−1 for F and Cl, 15 mg kg−1 for S, 0.2 mg kg−1 for Br and 0.02 mg kg−1 for I. These detection limits may be improved by increasing the amount of sample and hence the concentration of the final solution. Water was also determined using an extraction technique based on H2O degassing, reduction on zinc at 1000 °C and H2 manometry. Our results for fluorine, chlorine, sulfur and water are in good agreement with literature data. Very few reference materials have recommended values for bromine and especially for iodine. Among the analysed samples, three are new reference materials: BHVO-2, BCR-2 and AGV-2.  相似文献   

6.
A method to determine F and Cl in silicate materials by employing pyrohydrolysis and ion chromatography (IC) is described. Pyrohydrolysis involved mixing a pulverised sample (∼ 40 mg) with V2O5 (∼ 160 mg) and heating to 1100 °C under a wet oxygen flow in a quartz tube. Recovery yields of F and Cl were ∼ 97% using a NaF + NaCl standard solution. Detection limits of the pyrohydrolysis-IC method for silicate samples were 0.36 and 0.69 μg g-1 for F and Cl, respectively. Fluorine and Cl concentrations were determined in the reference materials JB-2, JB-3 and JA-1 from the GSJ; BCR-2, BHVO-1, BHVO-2, AGV-1 and AGV-2 from the USGS; and NIST SRM 610, 612 and 614 glasses. Precisions (RSD) for determinations of F were 1–13% (except NIST SRM 614) and 2–19% for Cl, and were dependent on the concentration and blank correction. Most results obtained in this study were in good agreement with those of previous studies. In comparison, the Na2CO3 + ZnO fusion method at 900 °C showed that the yields of F and Cl by alkaline fusion systematically decreased with fusion duration time. The yields were 84% and 83% for JB-3, inferring that F and Cl were lost in this alkaline fusion.  相似文献   

7.
A selective and sensitive method for the extraction and spectrophotometric determination of gold with N,N′‐6,7,9,10,17,18,20,21‐octahydrodibenzo[b,k][1,4,7,10,13,16] hexaoxacyclo‐octadecine‐2,13–diylbis(2‐chloroacetamide) (ODBOCA) is described. The ODBOCA–Au(III) complex was extracted from a slightly acidic aqueous solution (pH 5) into a chloroform layer and then the absorbance of the extract was measured using a UV–Vis spectrophotometer with 1.0 cm quartz cells at 540 nm. An enrichment factor of 200 was achieved. In the chloroform medium at 540 nm, the molar absorptivity and Sandell’s sensitivity were 4.12 × 103 l mol?1 cm?1 and 0.048 μg cm?2, respectively. Beer’s law was obeyed in the range of 0.5–15 μg ml?1 in the measured solution. The relative standard deviation for ten replicate samples at the 1.0 μg ml?1 level was 3.0%. The limit of detection, based on 3s, was 0.5 μg l?1 in the original sample. The effects of pH, ligand concentration and shaking time were studied. The ratio of the metal ion to ligand molecules in the complex was found to be 1:2 according to the Job Method. The effects of interference by a number of metal ions were investigated. The method was verified with certified reference materials and spiked tests, and quantitative recovery values were obtained. The method was fast, accurate, selective and precise, and was applied to the determination of gold in water and ore with good results.  相似文献   

8.
We report a measurement procedure to determine simultaneously the major cation concentrations (Na, Ca, K and Mg) of seawater‐derived solutions by inductively coupled plasma‐atomic emission spectrometry. The best results were obtained when the IAPSO (‘standard’) seawater reference material was diluted by thirty times with Milli‐Q® water. We obtained an average reference value rK (the ratio of the mass fraction of potassium to that of chlorine, i.e., (g kg?1)/(g kg?1)) for IAPSO seawater of 0.0205 ± 0.0006 (2.9% RSD), not significantly different from 0.0206 ± 0.0005 (2.4% RSD) for seawater composition reported in the literature. The measured Na, Ca and Mg concentrations correspond to rNa, rCa and rMg values of 0.5406 ± 0.0026 (0.5% RSD), 0.02192 ± 0.00048 (2.2% RSD) and 0.06830 ± 0.00047 (0.7% RSD), respectively, in line with previous values measured by wet‐chemistry and atomic absorption spectrophotometry or wet‐chemical titration. Our measurement procedure was used successfully on synthetic seawater solutions and high‐temperature hydrothermal fluids.  相似文献   

9.
A specific method for the determination of bromine and iodine species in drinking water was developed by using high performance liquid chromatography‐ICP‐MS. An ICS‐A23 ion chromatography column was chosen for the separation of species, with the mobile phase being 0.03 mol l?1 ammonium carbonate at a flow rate of 0.8 ml min?1. The detection limits for BrO3?, Br?, IO3? and I? were 0.032, 0.063, 0.008 and 0.012 μg l?1, respectively. Spectroscopic interferences were only observed in blank samples and mainly resulted from the argon‐potassium polyatomic ion (40Ar39K+). However, this interference was negligible because of the elution and complete separation from that of iodinate under optimised conditions. The method developed was successfully applied to twenty‐two samples of drinking water obtained from a supermarket. Results indicated that 36.4% of the samples had BrO3? concentrations exceeding the Chinese national limit for drinking water of 10 μg l?1.  相似文献   

10.
The effects of acute and chronic exposure to tributyltin (TBT) were examined in bioassays using horseshoe crab (Limulus polyphemus) embryos and “trilobite” larvae. Larvae had>95% survival after 24-h exposure to nominal concentrations of 1–500 μg l?1 TBT. Survival was also high following 48-h and 72-h exposure to ≤100 μg l?1 TBT; >50% mortality was seen only after 48-h and 72-h exposure to 500 μg l?1 TBT. Estimated median lethal concentrations (LC50) were >1000 μg l?1, 742 μg l?1, and 594 μg l?1 for 24-h, 48-h, and 72-h exposure, respectively. Much higher toxicity LC50=42 μg l?1) was seen following chronic exposure of larvae to TBT. Acute exposure to TBT significantly increased the time required by larvae to molt into the first-tailed stage. LC50 for horseshoe crab embryos exposed to TBT were 44 μg l?1, 20 μg l?1, and 14 μg l?1 for 24, 48, and 72 h acute exposure, indicating that this earlier developmental stage was about 30–40 fold more susceptible to TBT than larvae. Horseshoe crabs are highly tolerant of TBT in comparison to early developmental stages of other marine arthropods. The ability of horseshoe crab embryos and larvae to survive in the presence of organotin pollution suggests the possibility of bioaccumulation and movement into the estuarine food chain via shorebirds, gulls, and fish.  相似文献   

11.
Trace amounts of three halogens (chlorine, bromine and iodine) in seventeen U.S. Geological Survey (USGS) geochemical reference materials were determined by radiochemical neutron activation analysis (RNAA). The materials analysed were AGV‐2 (andesite), BCR‐2, BHVO‐2 and BIR‐1a (basalts), CLB‐1 (coal), COQ‐1 (carbonatite), DGPM‐1 (disseminated gold ore), DNC‐1a (dolerite), DTS‐2b (dunite), GSP‐2 (granodiorite), Nod‐A‐1 and Nod‐P‐1 (manganese nodules), QLO‐1a (quartz latite), SBC‐1 (marine shale), SDC‐1 (mica schist), SGR‐1b (shale rock) and W‐2a (diabase). The chlorine, bromine and iodine contents were determined to be 5.64 mg kg?1 (BIR‐1a) to 4410 mg kg?1 (Nod‐A‐1), 0.039 mg kg?1 (BIR‐1a) to 52.1 mg kg?1 (CLB‐1), and 0.041 mg kg?1 (BIR‐1a) to 599 mg kg?1 (CLB‐1), respectively. The RNAA data of the three halogens were compared with the corresponding data in the literature.  相似文献   

12.
A rapid and inexpensive method was developed for the determination of trace silver in polymetallic ore samples by use of eggshell membrane (ESM), a natural biomaterial, as the solid‐phase extraction (SPE) adsorbent coupled with flame atomic absorption spectrometry (FAAS). The ESM was used for the separation/pre‐concentration of silver, and the parameters affecting sensitivity, such as pH, sample flow rate, eluent volume and eluent flow rate, were carefully investigated. ESM was found to be an effective solid phase extractant for the adsorption of trace silver over a wide range of acidity from 0.02 to 0.50 mol l?1 HNO3. The sample solution in 0.4 mol l?1 HNO3 was pumped through an ESM microcolumn at the rate of 1.0 ml min?1. Silver was absorbed, and then eluted with a solution of 1.0% m/v thiourea–0.5% v/v HCl. Under these optimal conditions, ESM exhibited a good enrichment efficiency for silver with a dynamic adsorption capacity of 1.7 mg g?1. The proposed method was applied to the FAAS determination of trace silver in polymetallic ores and geological reference materials, GSO‐2, 3 and 5, and GSD‐11, GSD‐12, and the determined values were in good agreement with certified values.  相似文献   

13.
An in situ, medium‐resolution LA‐ICP‐MS method was developed to measure the abundances of the first‐row transition metals, Ga and Ge in a suite of geological materials, namely the MPI‐DING reference glasses. The analytical protocol established here hinged on maximising the ablation rate of the ultraviolet (UV) laser system and the sensitivity of the ICP‐MS, as well minimising the production of diatomic oxides and argides, which serve as the dominant sources of isobaric interferences. Non‐spectral matrix effects were accounted for by using multiple external calibrators, including NIST SRM 610 and the USGS basaltic glasses BHVO‐2G, BIR‐1G and BCR‐2G, and utilising 43Ca as an internal standard. Analyses of the MPI‐DING reference glasses, which represent geological matrices ranging from basaltic to rhyolitic in composition, included measurements of concentrations as low as < 100 μg g?1 and as high as > 104 μg g?1. The new data reported here were found to statistically correlate with the ‘preferred’ reference values for these materials at the 95% confidence level, though with significantly better precision, typically on the order of ≤ 3% (2sm). This analytical method may be extended to any matrix‐matched geological sample, particularly oceanic basalts, silicate minerals and meteoritic materials.  相似文献   

14.
《Applied Geochemistry》2002,17(3):259-284
Groundwaters from Quaternary loess aquifers in northern La Pampa Province of central Argentina have significant quality problems due to high concentrations of potentially harmful elements such as As, F, NO3-N, B, Mo, Se and U and high salinity. The extent of the problems is not well-defined, but is believed to cover large parts of the Argentine Chaco-Pampean Plain, over an area of perhaps 106 km2. Groundwaters from La Pampa have a very large range of chemical compositions and spatial variability is considerable over distances of a few km. Dissolved As spans over 4 orders of magnitude (<4–5300 μg l−1) and concentrations of F have a range of 0.03–29 mg l−1, B of 0.5–14 mg l−l, V of 0.02–5.4 mg l−1, NO3–N of <0.2–140 mg l−1, Mo of 2.7–990 μg l−1 and U of 6.2–250 μg l−1. Of the groundwaters investigated, 95% exceed 10 μg As l−1 (the WHO guideline value) and 73% exceed 50 μg As l−1 (the Argentine national standard). In addition, 83% exceed the WHO guideline value for F (1.5 mg l−1), 99% for B (0.5 mg l−1), 47% for NO3-N (11.3 mg l−1), 39% for Mo (70 μg l−1), 32% for Se (10 μg l−1) and 100% for U (2 μg l−1). Total dissolved solids range between 730 and 11400 mg l−1, the high values resulting mainly from evaporation under ambient semi-arid climatic conditions. The groundwaters are universally oxidising with high dissolved-O2 concentrations. Groundwater pHs are neutral to alkaline (7.0–8.7). Arsenic is present in solution predominantly as As(V). Groundwater As correlates positively with pH, alkalinity (HCO3), F and V. Weaker correlations are also observed with B, Mo, U and Be. Desorption of these elements from metal oxides, especially Fe and Mn oxides under the high-pH conditions is considered an important control on their mobilisation. Mutual competition between these elements for sorption sites on oxide minerals may also have enhanced their mobility. Weathering of primary silicate minerals and accessory minerals such as apatite in the loess and incorporated volcanic ash may also have contributed a proportion of the dissolved As and other trace elements. Concentrations of As and other anions and oxyanions appear to be particularly high in groundwaters close to low-lying depressions which act as localised groundwater-discharge zones. Concentrations up to 7500 μg l−1 were found in saturated-zone porewaters extracted from a cored borehole adjacent to one such depression. Concentrations are also relatively high where groundwater is abstracted from close to the water table, presumably because this zone is a location of more active weathering reactions. The development of groundwaters with high pH and alkalinity results from silicate and carbonate reactions, facilitated by the arid climatic conditions. These factors, together with the young age of the loess sediments and slow groundwater flow have enabled the accumulation of the high concentrations of As and other elements in solution without significant opportunity for flushing of the aquifer to enable their removal.  相似文献   

15.
Two large pegmatitic crystals of sodic pyroxene (aegirine) and sodic amphibole (arfvedsonite) from the agpaitic igneous Ilímaussaq Complex, south Greenland were found to be suitable as reference materials for in situ Li isotope determinations. Lithium concentrations determined by SIMS and micro‐drilled material analysed by MC‐ICP‐MS generally agreed within analytical uncertainty. The arfvedsonite crystal was homogeneous with [Li] = 639 ± 51 μg g?1 (2s, n = 69, MC‐ICP‐MS and SIMS results). The aegirine crystal shows strongly developed sector zoning, which is a common feature of aegirines. Using qualitative element mapping techniques (EPMA), the homogeneous core of the crystal was easily distinguished from the outermost sectors of the crystals. The core had a mean [Li] of 47.6 ± 3.6 μg g?1 (2s, n = 33) as determined by SIMS. The seven micro‐drilled regions measured by solution MC‐ICP‐MS returned slightly lower concentrations (41–46 μg g?1), but still overlap with the SIMS data within uncertainty. Based on MC‐ICP‐MS and SIMS analyses, the variation in δ7Li was about 1‰ in each of the two crystals, which is smaller than that in widely used glass reference materials, making these two samples suitable to serve as reference materials. There was, however, a significant offset between the results of MC‐ICP‐MS and SIMS. The latter deviated from the MC‐ICP‐MS results by ?6.0 ± 1.9‰ (2s) for the amphibole and by ?3.9 ± 1.9‰ (2s) for the aegirine. This indicates the presence of a significant matrix effect in SIMS determinations of Li isotopes for amphibole and pyroxene relative to the basalt glasses used for calibration. Based on the MC‐ICP‐MS results, mean δ7Li values of +0.7 ± 1.2‰ (2s, n = 10) for the arfvedsonite crystal and of ?3.7 ± 1.2‰ (2s, n = 7) for the core of the aegirine crystal were calculated. Adopting these values, SIMS users can correct for the specific IMF (instrumental mass fractionation) of the ion probe used. We propose that these two crystals serve as reference materials for in situ Li isotope determinations by SIMS and pieces of these two crystals are available from the first author upon request.  相似文献   

16.
Pressed powder pellets and fused beads or glass disks are routinely used in X‐ray fluorescence spectrometry for the determination of major and trace elements, respectively, in geological materials. In order to evaluate the performance of these two sample preparation methods, we determined Ni and Cr concentrations of fourteen RMs from Japan, France and South Africa, and eighty‐five igneous and three sedimentary rock samples from Mexico in both powder pellets and glass beads. We also computed new values of statistical parameters for RMs from an outlier‐based multiple‐test method and compared them with the literature mean and confidence limit values. The results showed that the multiple‐test method provided more reliable central tendency and dispersion parameters for RMs than those obtained previously from the two or three standard deviation method, or from robust methods. The powder pellet and fused bead sample preparation methods provided consistent results for Ni and Cr at concentration levels > 50 μg g?1 in this application; for lower concentration levels, however, these methods showed somewhat greater differences. For quantitative comparisons, both ordinary and weighted least‐squares linear regression models were used to show that the two sample preparation methods provided generally unbiased results.  相似文献   

17.
Geological reference materials (RMs) with variable compositions and NIST SRM 612 were analysed by isotope dilution mass spectrometry for bulk rock concentrations of chalcogen elements (sulfur, selenium and tellurium), rhenium and platinum‐group elements (PGEs: Ru, Pd, Os, Ir and Pt), including the isotope amount ratios of 187Os/188Os. All concentrations were obtained from the same aliquot after HCl‐HNO3 digestion in a high pressure asher at 320 °C. Concentrations were determined after chemical separation by negative TIMS, ICP‐MS and hydride generation ICP‐MS (Se, Te). As in previous studies, concentrations of the PGEs in most RMs were found to be highly variable, which may be ascribed to sample heterogeneity at the < 1 g level. In contrast, S, Se and Te displayed good precision (RSD < 5%) in most RMs, suggesting that part of the PGE budget is controlled by different phases, compared with the chalcogen budget. The method may minimise losses of volatile chalcogens during the closed‐system digestion and indicates the different extent of heterogeneity of chalcogens, Re and PGEs in the same sample aliquot. OKUM, SCo‐1, MRG‐1, DR‐N and MAG‐1 are useful RMs for the chalcogens. NIST SRM 612 displays homogenous distribution of S, Se, Te, Pt and Pd in 30 mg aliquots, in contrast with micro‐scale heterogeneity of Se, Pd and Pt.  相似文献   

18.
A simple, rapid method for the determination of Re and Os concentrations and isotope compositions using isotope dilution multi‐collector inductively coupled plasma‐mass spectrometry (ID‐MC‐ICP‐MS) combined with Carius tube digestion and sparging introduction of Os was developed. For Os measurement, four channeltron ion counters to detect different Os isotopes were used simultaneously, which led to a drastic reduction in the measurement time. Rhenium isotopes were measured by means of eight Faraday cups with solution nebulisation and an ultrasonic membrane desolvator. The representative 188Os count rate of an Os standard solution containing 50 pg of total Os was approximately 110000–120000 cps at the onset of measurement; the Re intensity of our in‐house 10 pg g?1 standard solution reached 1820 V/μg g?1 with a sample uptake rate of 95–99 μl min?1. These values indicate that the sensitivity of the method was sufficient even for samples with low Re and Os concentrations, such as chert. As the temporal variations of the amplification efficiency of the ion counters differed from one another, we adopted a sample‐calibrator bracketing method to correct the measured Re and Os isotope ratios. The Re and Os concentrations via the isotope dilution method and the 187Os/188Os ratios of two sedimentary rock reference materials (JMS‐2 and JCh‐1) on the basis of the isotope ratios determined by the MC‐ICP‐MS and by negative thermal ionisation mass spectrometry (N‐TIMS) were comparable within their ranges. Based on Os isotope measurement of the IAG reference material [Durham Romil Os (DROsS)], the average difference from the recommended value and precision of Os isotope measurements by the sparging method in combination with multi‐ion‐counters were 0.72% and 0.76% [1RSD (%), n = 29], respectively. The precisions in the 187Os/188Os ratios [1RSD (%)] of JMS‐2, JCh‐1 and DROsS were 0.35–0.71, 1.56–3.31 and 0.99–1.28%, respectively, which depended on their Os ion intensities. No systematic difference was observed between the Re and Os geochemical compositions of JCh‐1 and JMS‐2 obtained by means of digestion with inverse aqua regia and CrO3‐H2SO4 solutions, suggesting that either acid solution can be used for the sparging method of sedimentary rock samples. As CrO3‐H2SO4 solution is believed to liberate predominantly the hydrogenous Re and Os fraction from organic‐rich sediment, the sparging method combined with CrO3‐H2SO4 digestion and multi‐ion‐counters in the mass spectrometry is expected to be a powerful tool for reconstructing the secular change in marine Os isotope compositions with high sample throughput.  相似文献   

19.
The strong spectral interference between Br‐ and Al‐induced X‐ray lines hampers the utilisation of electron probe microanalysis (EPMA) for measuring Br mass fractions in Al‐bearing minerals and glasses. Through measuring Br‐free Al‐bearing materials, we established an EPMA method to quantify the overlap from AlKα on BrLβ, which can be expressed as a linear function of the Al2O3 content. The count rate of the BrLβ peak signal was enhanced by high beam currents and long measurement times. Application of this EPMA method to Al‐ and Br‐bearing materials, such as sodalite and scapolite, and to five experimental glasses yielded Br mass fractions (in the range of 250–4000 μg g?1) that are consistent with those measured by microbeam synchrotron X‐ray fluorescence (μ‐SXRF) spectrometry. The EPMA method has an estimated detection limit of ~ 100–300 μg g?1. We propose that this method is useful for measuring Br mass fractions (hundreds to thousands of μg g?1) in Al‐bearing minerals and glasses, including those produced in Br‐doped experiments. In addition, the natural marialitic scapolite (ON70) from Mpwapwa (Tanzania) containing homogeneously distributed high mass fractions of Br (2058 ± 56 μg g?1) and Cl (1.98 ± 0.03% m/m) is an ideal reference material for future in situ analyses.  相似文献   

20.
A method for the simultaneous determination of Cd with In, Tl and Bi by isotope dilution‐internal standardisation (ID‐IS) ICP‐QMS using the same aliquot for rare earth element and other trace element determinations was developed. Samples mixed with an enriched 149Sm spike were decomposed using a HF‐HClO4 mixture, which was evaporated and then diluted with HNO3. After determination of Sm by ID‐ICP‐QMS and Cd, In, Tl and Bi concentrations were determined using the 149Sm intensity as an internal standard. The interference of MoO+ on Cd+ was corrected using the MoO+/Mo+ ratio separately measured using a Mo standard solution, and the validity of the externally determined oxide‐forming ratio correction was evaluated. The MoO+/Mo+ ratios measured using the standard solution and samples were ~ 0.0002 and < 0.002, respectively. Detection limits for Cd, In, Tl and Bi in silicate samples were at levels of < 1 ng g?1 with a total uncertainty of < 7%. Cadmium in the carbonaceous chondrites, Orgueil (CI1), Murchison (CM2) and Allende (CV3) as well as Cd, In, Tl and Bi in the reference materials, JB‐2, JB‐3, JA‐1, JA‐2, JA‐3, JP‐1 (GSJ), BHVO‐1, AGV‐1, PCC‐1 and DTS‐1 (USGS) and NIST SRM 610, 612, 614 and 616 were determined to show the applicability of this method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号