首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Wave Energy Converters (WECs) have excellent potential as a source of renewable energy that is yet to be commercially realised. Recent attention has focused on the installation of Oscillating Water Column (OWC) devices as a part of harbor walls to provide advantages of cost–sharing structures and proximity of power generation facilities to existing infrastructure. In this paper, an incompressible three–dimensional CFD model is constructed to simulate a fixed Multi–Chamber OWC (MC–OWC) device. The CFD model is validated; the simulation results are found to be in good agreement with experimental results obtained from a scale physical model tested in a wave tank. The validated CFD model is then used for a benchmark study of 96 numerical tests. These investigate the effects of the PTO damping caused by the power take–off (PTO) system on device performance. The performance is assessed for a range of regular wave heights and periods. The results demonstrate that a PTO system with an intermediate damping can be used for all chambers in the MC–OWC device for most wave period ranges, except for the long wave periods. These require a higher PTO damping. An increased incident wave height reduces the device capture width ratio, but there is a noticeable improvement for long wave periods.  相似文献   

2.
The wave power extraction by a cylindrical oscillating water column (OWC) device with a quadratic power take-off (PTO) model was studied experimentally and theoretically. In the experiment, a scaled model OWC was tested in a wave flume, with an orifice being used to simulate a quadratic PTO mechanism. In the theoretical analysis, the quadratic PTO model was linearized based on Lorenz's principle of equivalent work, which allows us to perform a frequency domain analysis using an eigen-function matching method. The effects of higher harmonic components and the spatial non-uniformity of the surface velocity inside the chamber were discussed. A semi-analytical model was proposed to understand the viscous loss affecting the measured capture length. Our treatment of the quadratic PTO model was validated by comparing quasi-linear theoretical capture length and the laboratory measurement. Our results also showed that the effects of spatial non-uniformity and viscous loss could be noticeable for shorter waves.  相似文献   

3.
The oscillating water column (OWC) device is in a leading position for wave power extraction but has not achieved fully commercial at the current stage. In addition to enhancing the OWC performance, installing OWCs on floating breakwaters, which owns the merits of both cost-sharing and offshore power supply, is a practicality with high economic viability. In this study, a series of wave-flume experiments were conducted in regular waves to examine the wave power extraction of a floating box-type breakwater with dual pneumatic chambers. The flow characteristics of the orifices used to simulate the PTOs was pre-calibrated through another series of experiments, so the power extraction in this study can be obtained with only the pressure measurement. The effects of wave period, chamber draft, water depth and arrangement of chambers on the power extraction were examined. Our experimental results showed that the power extraction was mainly due to the water column oscillation inside the chamber, and differentiation in the designed natural periods of dual chambers could widen the efficiency bandwidth of power extraction. The front chamber always played the main role in power extraction and its natural period should be designed against the dominating period of the wave spectrum; in contrast, the power extraction of the rear chamber was only a supplement and its natural period should be designed against longer waves which were more easily transmitted, thus a PTO of small power capacity maybe more realistic. It was also worth noting that the water column oscillation was more dependent on the wave period rather than controlled by the wave scattering under different water depths.  相似文献   

4.
An Oscillating Water Column (OWC) device can output energy through reciprocating or unidirectional airflow. The unidirectional airflow is helpful to utilize a simple and high-efficiency unidirectional air turbine. The pentagonal BBDB proposed by us based on OWC principle can be regarded as a floating Oscillating Body and its Power Take-Off (PTO) consists of a chamber, a water column, a turbine and a generator. The Capture Width Ratio (CWR) of the pentagonal BBDB model with the reciprocating and unidirectional airflow was studied in this paper. The wave flume test results indicate the mean CWR of the pentagonal BBDB model with reciprocating airflow can reach up to 121.91% and the mean CWR of the model with unidirectional airflow could reach 100.94% during the whole wave cycle in regular waves. For irregular waves, the mean CWR of the model with the unidirectional airflow is as high as 62.83% during the whole wave cycle. Hopefully, the combination of the pentagonal BBDB with the check valve to output power during the air exhalation and conventional high-efficiency unidirectional turbine will improve the total efficiency of the BBDB.  相似文献   

5.
针对波浪能转换装置(WEC)研究重点主要集中在能量捕获效率方面,而忽略其附带的消波功能的问题。基于Open FOAM程序,建立垂荡浮子式波浪能发电装置与桩式约束的浮式防波堤的集成系统(OBC-FB)。主要研究WEC中的重要组件动力输出系统(PTO)对集成系统波能捕获效率及消波性能的影响。分析流体黏性影响下线性PTO系统的最优PTO阻尼特性。开发非线性电磁阻尼模型与线性PTO系统性能进行比较。结果显示,考虑黏性影响下线性的最优PTO阻尼系数略大于无黏的理论值;适当增大PTO阻尼系数可以获得更大的波能捕获宽度比(CWR),从而可以保证装置单位特征尺寸的波能转换效率更高,同时可以在更宽波况范围保证消波性能;相较于线性PTO阻尼系统,非线性电磁PTO阻尼系统可以更好地兼顾波能捕获效率和消波性能。因此,在OBC-FB集成系统的优化设计中,PTO阻尼系统是一个重要的优化参数。  相似文献   

6.
Oscillating Water Column (OWC) is one of the pioneer devices in harnessing wave energy; however, it is not fully commercialized perhaps due to the complicated hydrodynamic behavior. Previous studies are significantly devoted to OWC devices located in nearshore and coastal regions where incident wave energy would experience dissipation more than offshore. In this paper, a 1:15 scaled fixed offshore OWC model is tested in a large towing tank of National Iranian Marine Laboratory. Wave spectrum shape effect on the efficiency of the OWC model is addressed. Moreover, the paper investigates the effects of the geometric and hydrodynamic factors on OWC device efficiency and uncovers new points in nonlinear interaction occurring inside the chamber; i.e. sloshing. The results indicate that shape of the spectrum inside the chamber is affected by the type of incident wave spectrum, especially for long waves. Pierson–Moskowitz spectrum leaded to higher efficiency rather than JONSWAP spectrum at longer incident wave periods. According to efficiency analysis, increasing wave height may lead to air leakage from the chamber followed by vortex generation, which is a reason for decreasing the efficiency of the OWC device. Furthermore, no shift in the resonant period of the OWC model, due to wave height increase, was observed at the opening ratios equal or smaller than 1.28%. Spectral analysis of water fluctuation inside the OWC chamber illustrates two modes of sloshing. The first mode can be seen at short period waves while the second mode is visible at long period waves. The sloshing modes approximately vanish by increasing draft value.  相似文献   

7.
Eddy current brakes provide a versatile way of simulating the power take-off system (PTO) in model testing of small scale wave energy converters (WECs). This type of PTO simulator is based on the principle that a conductive material moving in a magnetic field generates a braking force proportional to its velocity. A bottom-hinged pitching plate WEC model has been designed using an eddy current brake as a PTO simulator. A dedicated electric current source unit was developed to provide a controllable and reliable level of DC current intensity to feed the magnetic field generating coils. Using a real-time data acquisition and control, this unit can be used to impose non-linear damping PTO characteristic curves in several types of WEC models based on eddy current brakes. In the present case, this current source has been used to simulate a constant damping PTO on a small scale pitching WEC model that has been tested in the IST wave flume. Two different cases were considered: one corresponding to a surface piercing plate and another to a fully submerged plate. Experimental results are presented for plate motion and for non-dimensional capture width.  相似文献   

8.
Raft-type wave energy converter (WEC) is a multi-mode wave energy conversion device, using the relative pitch motion to drive its hydraulic power take-off (PTO) units for capturing energy from the ocean waves. The hydraulic PTO unit as its energy conversion module plays a significant role in storing large qualities of energy and making the output power smooth. However, most of the previous investigations on the raft-type WECs treat the hydraulic PTO unit as a linear PTO unit and do not consider the dynamics of the hydraulic circuit and components in their investigations. This paper is related to a two-raft-type WEC consisting of two hinged rafts and a hydraulic PTO unit. The aim of this paper is to make an understanding of the dynamics of the hydraulic PTO unit and how these affect the performance of the two-raft-type WEC. Therefore, a combined hydrodynamic and hydraulic PTO unit model is proposed to investigate and optimize the performance of the two-raft-type WEC; and based on the simulation of the combined model, the relationships between the optimal power capture ability, the optimal magnitude of the hydraulic PTO force and the wave states are numerically revealed. Results show that an approximately square wave type hydraulic PTO force is produced by the hydraulic PTO unit, which causes the performance of the two-raft-type WEC not to be sinusoidal and the energy capturing manner different from that of the device using a linear PTO unit; moreover, there is an optimal magnitude of the hydraulic PTO force for obtaining an optimal power capture ability, which can be achieved by adjusting the parameters of the hydraulic PTO unit; in regular waves, the optimal power capture ability as well as the optimal magnitude of the hydraulic PTO force normalized by the wave height presents little relationship with the wave height, mainly depends on the wave period; in irregular waves, the trends of the optimal power capture ability and the normalized optimal magnitude of the hydraulic PTO force against the peak wave periods at different significant wave heights are generally identical and show a good correlation. All means that the hydraulic PTO unit of the two-raft-type WEC can be tuned to the wave states, and these would provide a valuable guidance for the optimal design of its hydraulic PTO unit.  相似文献   

9.
The performance of an oscillating water column (OWC) wave energy converter depends on many factors, such as the wave conditions, the tidal level and the coupling between the chamber and the air turbine. So far most studies have focused on either the chamber or the turbine, and in some cases the influence of the tidal level has not been dealt with properly. In this work a novel approach is presented that takes into account all these factors. Its objective is to develop a virtual laboratory which enables to determine the pneumatic efficiency of a given OWC working under specific conditions of incident waves (wave height and period), tidal level and turbine damping. The pneumatic efficiency, or efficiency of the OWC chamber, is quantified by means of the capture factor, i.e. the ratio between the absorbed pneumatic power and the available wave energy. The approach is based on artificial intelligence—in particular, artificial neural networks (ANNs). The neural network architecture is chosen through a comparative study involving 18 options. The ANN model is trained and, eventually, validated based on an extensive campaign of physical model tests carried out under different wave conditions, tidal levels and values of the damping coefficient, representing turbines of different specifications. The results show excellent agreement between the ANN model and the experimental campaign. In conclusion, the new model constitutes a virtual laboratory that enables to determine the capture factor of an OWC under given wave conditions, tidal levels and values of turbine damping, at a lower cost and in less time than would be required for conventional laboratory tests.  相似文献   

10.
波浪与带窄缝方箱作用共振现象的数值模拟   总被引:1,自引:1,他引:0  
By introducing a source term into the Laplace equation, a two-dimensional fully nonlinear time-domain numerical wave flume (NWF) is developed to investigate the resonance induced by the interaction bet...  相似文献   

11.
The motion and the drift force of a floating OWC (oscillating water column) wave energy device in regular waves are studied taking account of the oscillating surface-pressure due to the pressure drop across the duct of the air chamber. The potential problem inside the chamber is formulated by making use of the Green integral equation associated with the Rankine-type Green function while the outer problem with the Kelvin-type Green function. The added mass, wave damping and excitation coefficients as well as the motion and drift force of the OWC device are calculated for various values of parameter related to the pressure drop.  相似文献   

12.
基于推板造波理论和摇板造波理论,在Open FOAM平台上采用重叠网格技术建立黏性数值波浪水槽,并使用一种结合SIMPLE算法和PISO算法的PIMPLE算法对数值模型进行求解。利用开发的数值模型通过数值收敛性测试和网格独立性测试分别重点研究了时间步长、库朗数和网格尺寸对数值精度和计算效率的影响。并对比研究了此数值模型分别嵌入层流模型和湍流模型的计算精度和计算效率。实现的规则波和二阶有限振幅波与理论结果和试验结果吻合,验证了此黏性数值波浪水槽的造波和主动消波功能。基于二维数值波浪水槽,进一步研究了三维数值造波,数值计算结果与理论结果吻合良好。研究结果不仅验证了重叠网格在二维和三维两相流体域中求解运动物体与流场交互的可靠性和正确性,而且为使用此黏性数值波浪水槽解决更复杂的海洋工程问题提供了依据。  相似文献   

13.
A pile-supported OWC breakwater is a novel marine structure in which an oscillating water column (OWC) is integrated into a pile-supported breakwater, with a dual function: generating carbon-free energy and providing shelter for port activities by limiting wave transmission. In this work we investigate the hydrodynamics of this novel structure by means of an analytical model based on linear wave theory and matched eigenfunction expansion method. A local increase in the back-wall draft is adopted as an effective strategy to enhance wave power extraction and reduce wave transmission. The effects of chamber breadth, wall draft and air chamber volume on the hydrodynamic performance are examined in detail. We find that optimizing power take-off (PTO) damping for maximum power leads to both satisfactory power extraction and wave transmission, whereas optimizing for minimum wave transmission penalizes power extraction excessively; the former is, therefore, preferable. An appropriate large enough air chamber volume can enhance the bandwidth of high extraction efficiency through the air compressibility effect, with minimum repercussions for wave transmission. Meanwhile, the air chamber volume is found to be not large enough for the air compressibility effect to be relevant at engineering scales. Finally, a two-level practical optimization strategy on PTO damping is adopted. We prove that this strategy yields similar wave power extraction and wave transmission as the ideal optimization approach.  相似文献   

14.
15.
点吸收式波能转换装置是具有较好应用前景的一种波浪能开发利用装置,其参数设计直接影响到波浪能开发利用的可行性与有效性。作者针对青岛斋堂岛目标海域海况,通过数值模拟首先应用单因素敏感性分析法分析了双浮子点吸收式波能转换装置的结构尺寸、锚固形式、波流夹角、PTO阻尼、PTO刚度等参数对装置俘能功率的独立影响规律。之后考虑多参数的综合影响,通过运用稳健设计方法,以上述参数为控制因子并确定合理的变动水准,将俘能功率作为评价标准,选取合理的正交实验L矩阵,得到了不同参数组合情况下的装置俘能功率并进行统计分析。结果表明,浮子尺寸、PTO阻尼、波流夹角对装置俘能功率影响较大,而PTO刚度、锚链与铅垂线夹角、锚链与波浪在水平面内的夹角对俘能功率影响不明显。提出的参数研究方法可为其他海域点吸收式波能转换装置参数设计提供参考。  相似文献   

16.
陈文  滕斌 《海洋工程》2014,32(6):59-67
基于势流理论,建立波浪与摆式波能转换装置作用的三维频域分析模型。应用数值模型对两种质量的摆式波能转换装置进行水动力分析,在考虑粘性阻尼作用的条件下,计算传动系统的最优扭阻系数。在最佳工况下,开展了波浪频率对摆板运动响应和俘获能量影响的系统研究,给出了波浪最佳频率范围、摆板振幅、能量俘获效率以及摆板表面的波动压强。  相似文献   

17.
Investigation on the Oscillating Buoy Wave Power Device   总被引:4,自引:0,他引:4  
SU  Yongling 《中国海洋工程》2002,16(1):141-149
An oscillating buoy wave power device (OD) is a device extracting wave power by an oscillating buoy. Being excited by waves, the buoy heaves up and down to convert wave energy into electricity by means of a mechanical or hydraulic device. Compared with an Oscillating Water Column (OWC) wave power device, the OD has the same capture vvidth ratio as the OWC does, but much higher secondary conversion efficiency. Moreover, the chamber of the OWC, which is the most expensive and difficult part to be built, is not necessary for the OD, so it is easier to construct an OD. In this paper, a nu-merical calculation is conducted for an optimal design of the OD firstly, then a model of the device is built and, a model test is carried out in a wave tank. The results show that the total efficiency of the OD is much higher than that of the OWC and that the OD is a promising wave power device.  相似文献   

18.
本文对振荡水柱波能装置的水柱做了时域计算,研究了内水柱在气室处于封闭状态、有阻尼状态和无阻尼状态下的动力响应。得出了相应的波浪载荷,并对波能装置的几种保护措施作了探讨。数值结果表明,带有阻尼的气室不能有效地阻止内水柱的运动,将使结构承受危险载荷的打击;全封闭的气室能有效地阻止内水柱的运动,但可能使气室里产生高压;收缩口与破浪锥联合作用,可以消耗水柱的动能,大大地减少载荷,是一种有前途的保护措施。  相似文献   

19.
基于成本共享理念的波浪能发电装置(WEC)的开发与设计为降低建设成本提供了新的研究思路,应用计算流体力学方法对在透空箱式防波堤前附加垂荡浮子的集成装置进行数值模拟研究,主要研究了流体黏性和非线性PTO系统以及浮子形状对此类集成装置能量转换效率的影响。结果表明,此类集成装置可以获得较高的波能捕获宽度比(CWR),最高可达0.7,可以较好地利用反射波波能。共振区间上受黏性影响较大,相比于线性无黏理论解,CWR下降明显;实现了2种非线性PTO系统的模拟,有待于进一步的优化未获得更高的CWR值;浮子形状优化效果明显,采用圆底形浮子受黏性影响更小,可以获得更大的CWR值。此种集成模型的模拟和研究可以为新型防波堤设计和现有防波堤的改造提供思路和参考。  相似文献   

20.
The hydrodynamic functioning of an oscillating water column (OWC) in the presence of an underwater tri-dimensional mound (UTDM) through large-scale ocean engineering basin experiments is described. Experiments are carried out with both regular and irregular waves and are compared to numerical models. The analysis is based on the measurements of the wave amplification in the water column for the OWC performance and on surface deformation upwave and over the UTDM for the wave transformation due to both UTDM and OWC. A significant increase of the capture-width ratio due to wave focusing above the mound is observed experimentally. This wave focusing is also well described numerically with a refraction–diffraction model. The wave amplification in the water column for both regular and irregular waves is compared to results from a linear potential model based on an integral matching method. Linear behaviour of the hydrodynamic response of the device is verified for both open and partially closed conditions, in particular for irregular waves.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号