首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Real‐time testing with dynamic substructuring is a novel experimental technique capable of assessing the behaviour of structures subjected to dynamic loadings including earthquakes. The technique involves recreating the dynamics of the entire structure by combining an experimental test piece consisting of part of the structure with a numerical model simulating the remainder of the structure. These substructures interact in real time to emulate the behaviour of the entire structure. Time integration is the most versatile method for analysing the general case of linear and non‐linear semi‐discretized equations of motion. In this paper we propose for substructure testing, L‐stable real‐time (LSRT) compatible integrators with two and three stages derived from the Rosenbrock methods. These algorithms are unconditionally stable for uncoupled problems and entail a moderate computational cost for real‐time performance. They can also effectively deal with stiff problems, i.e. complex emulated structures for which solutions can change on a time scale that is very short compared with the interval of time integration, but where the solution of interest changes on a much longer time scale. Stability conditions of the coupled substructures are analysed by means of the zero‐stability approach, and the accuracy of the novel algorithms in the coupled case is assessed in both the unforced and forced conditions. LSRT algorithms are shown to be more competitive than popular Runge–Kutta methods in terms of stability, accuracy and ease of implementation. Numerical simulations and real‐time substructure tests are used to demonstrate the favourable properties of the proposed algorithms. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

2.
In this paper, Rosenbrock‐based algorithms originally developed for real‐time testing of linear systems with dynamic substructuring are extended for use on nonlinear systems. With this objective in mind and for minimal overhead, both two‐ and three‐stages linearly implicit real‐time compatible algorithms were endowed with the Jacobian matrices requiring only one evaluation at the beginning of each time step. Moreover, these algorithms were improved with subcycling strategies. In detail, the paper briefly introduces Rosenbrock‐based L‐Stable Real‐Time (LSRT) algorithms together with linearly implicit and explicit structural integrators, which are now commonly used to perform real‐time tests. Then, the LSRT algorithms are analysed in terms of linearized stability with reference to an emulated spring pendulum, which was chosen as a nonlinear test problem, because it is able to exhibit a large and relatively slow nonlinear circular motion coupled to an axial motion that can be set to be stiff. The accuracy analysis on this system was performed for all the algorithms described. Following this, a coupled spring‐pendulum example typical of real‐time testing is analysed with respect to both stability and accuracy issues. Finally, the results of representative numerical simulations and real‐time substructure tests, considering nonlinearities both in the numerical and the physical substructure, are explored. These tests were used to demonstrate how the LSRT algorithms can be used for substructuring tests with strongly nonlinear components. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
Real‐time substructuring is a method of dynamically testing a structure without experimentally testing a physical model of the entire system. Instead the structure can be split into two linked parts, the region of particular interest, which is tested experimentally, and the remainder which is tested numerically. A transfer system, such as a hydraulic actuator or a shaking table, is used to impose the displacements at the interface between the two parts on the experimental substructure. The corresponding force imposed by the substructure on the transfer system is fed back to the numerical model. Control of the transfer system is critical to the accuracy of the substructuring process. A study of two controllers used in conjunction with the University of Bristol shaking table is presented here. A proof‐of‐concept one degree‐of‐freedom mass–spring–damper system is substructured such that a portion of the mass forms the experimental substructure and the remainder of the mass plus the spring and the damper is modelled numerically. Firstly a linear controller is designed and tested. Following this an adaptive substructuring strategy is considered, based on the minimal control synthesis algorithm. The deleterious effect of oil‐column resonance common to shaking tables is examined and reduced through the use of filters. The controlled response of the experimental specimen is compared for the two control strategies. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

4.
Experimental techniques for testing dynamically substructured systems are currently receiving attention in a wide range of structural, aerospace and automotive engineering environments. Dynamic substructuring enables full‐size, critical components to be physically tested within a laboratory (as physical substructures), while the remaining parts are simulated in real‐time (as numerical substructures). High quality control is required to achieve synchronization of variables at the substructuring interfaces and to compensate for additional actuator system(s) dynamics, nonlinearities, uncertainties and time‐varying parameters within the physical substructures. This paper presents the substructuring approach and associated controller designs for performance testing of an aseismic, base‐isolation system, which is comprised of roller‐pendulum isolators and controllable, nonlinear magnetorheological dampers. Roller‐pendulum isolators are typically mounted between the protected structure and its foundation and have a fundamental period of oscillation far‐removed from the predominant periods of any earthquake. Such semi‐active damper systems can ensure safety and performance requirements, whereas the implementation of purely active systems can be problematic in this respect. A linear inverse dynamics compensation and an adaptive controller are tailored for the resulting nonlinear synchronization problem. Implementation results favourably compare the effectiveness of the adaptive substructuring method against a conventional shaking‐table technique. A 1.32% error resulted compared with the shaking‐table response. Ultimately, the accuracy of the substructuring method compared with the response of the shaking‐table is dependent upon the fidelity of the numerical substructure. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
Real‐time substructure testing is a novel method of testing structures under dynamic loading. The complete structure is separated into two substructures, one of which is tested physically at large scale and in real time, so that time‐dependent non‐linear behaviour of the substructure is realistically represented. The second substructure represents the surrounding structure, which is modelled numerically. In the current formulation this numerical substructure is assumed to remain linear. The two substructures interact in real‐time so that the response of the complete structure, incorporating the non‐linear behaviour of the physical substructure, is accurately represented. This paper presents several improvements to the linear numerical modelling of substructures for use in explicit time‐stepping routines for real‐time substructure testing. An extrapolation of a first‐order‐hold discretization is used which increases the accuracy of the numerical model over more direct explicit methods. Additionally, an integral form of the equation of motion is used in order to reduce the effects of noise and to take into account variations of the input over a time‐step. In order to take advantage of this integral form, interpolation of the model output is performed in order to smooth the output. The improvements are demonstrated using a series of substructure tests on a simple portal frame. While the testing approach is suitable for cases in which the physical substructure behaves non‐linearly, the results presented here are for fully linear systems. This enables comparisons to be made with analytical solutions, as well as with the results of tests based on the central difference method. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

6.
This paper presents a new method, called the equivalent force control method, for solving the nonlinear equations of motion in a real‐time substructure test using an implicit time integration algorithm. The method replaces the numerical iteration in implicit integration with a force‐feedback control loop, while displacement control is retained to control the motion of an actuator. The method is formulated in such a way that it represents a unified approach that also encompasses the effective force test method. The accuracy and effectiveness of the method have been demonstrated with numerical simulations of real‐time substructure tests with physical substructures represented by spring and damper elements, respectively. The method has also been validated with actual tests in which a Magnetorheological damper was used as the physical substructure. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

7.
In this paper we consider the concept of modelling dynamical systems using numerical–experimental substructuring. This type of modelling is applicable to large or complex systems, where some part of the system is difficult to model numerically. The substructured model is formed via the adaptive minimal control synthesis (MCS) algorithm. The aim of this paper is to demonstrate that substructuring can be carried out in real time, using the MCS algorithm. Thus, we reformulate the MCS algorithm into a substructuring form. We introduce the concepts of a transfer system, and carry out numerical simulations of the substructuring process using a coupled three mass example. These simulations are compared with direct simulations of a three mass system. In addition we consider the stability of the substructuring algorithm, which we discuss in detail for a class of second‐order transfer systems. A numerical–experimental system is considered, using a small‐scale experimental system, for which the substructuring algorithm is implemented in real time. Finally we discuss these results, with particular reference to the future application of this method to modelling large‐scale structures subject to earthquake excitation. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

8.
Real‐time hybrid simulation combines experimental testing of physical substructure(s) and numerical simulation of analytical substructure(s), and thus enables the complete structural system to be considered during an experiment. Servo‐hydraulic actuators are typically used to apply the command displacements to the physical substructure(s). Inaccuracy and instability can occur during a real‐time hybrid simulation if the actuator delay due to servo‐hydraulic dynamics is not properly compensated. Inverse compensation is a means to negate actuator delay due to inherent servo‐hydraulic actuator dynamics during a real‐time hybrid simulation. The success of inverse compensation requires the use of a known accurate value for the actuator delay. The actual actuator delay however may not be known before the simulation. An estimation based on previous experience has to be used, possibly leading to inaccurate experimental results. This paper presents a dual compensation scheme to improve the performance of the inverse compensation method when an inaccurately estimated actuator delay is used in the method. The dual compensation scheme modifies the predicted displacement from the inverse compensation procedure using the actuator tracking error. Frequency response analysis shows that the dual compensation scheme enables the inverse compensation method to compensate for actuator delay over a range of frequencies when an inaccurately estimated actuator delay is utilized. Real‐time hybrid simulations of a single‐degree‐of‐freedom system with an elastomeric damper are conducted to experimentally demonstrate the effectiveness of the dual compensation scheme. Exceptional experimental results are shown to be achieved using the dual compensation scheme without the knowledge of the actual actuator delay a priori. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
This paper presents novel predictor–corrector time‐integration algorithms based on the Generalized‐α method to perform pseudo‐dynamic tests with substructuring. The implicit Generalized‐α algorithm was implemented in a predictor–one corrector form giving rise to the implicit IPC–ρ∞ method, able to avoid expensive iterative corrections in view of high‐speed applications. Moreover, the scheme embodies a secant stiffness formula that can closely approximate the actual stiffness of a structure. Also an explicit algorithm endowed with user‐controlled dissipation properties, the EPC–ρb method, was implemented. The resulting schemes were tested experimentally both on a two‐ and on a six‐degrees‐of‐freedom system, using substructuring. The tests indicated that the numerical strategies enhance the fidelity of the pseudo‐dynamic test results even in an environment characterized by considerable experimental errors. Moreover, the schemes were tested numerically on severe non‐linear substructured multiple‐degrees‐of‐freedom systems reproduced with the Bouc–Wen model, showing the reliability of the seismic tests under these conditions. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

10.
Real‐time hybrid testing is a promising technique for experimental structural dynamics, in which the structure under consideration is split into a physical test of key components and a numerical model of the remainder. The physical test and numerical analysis proceed in parallel, in real time, enabling testing of critical elements at large scale and at the correct loading rate. To date most real‐time hybrid tests have been restricted to simple configurations and have used approximate delay compensation schemes. This paper describes a real‐time hybrid testing approach in which non‐linearity is permitted in both the physical and numerical models, and in which multiple interfaces between physical and numerical substructures can be accommodated, even when this results in very stiff coupling between actuators. This is achieved using a Newmark explicit numerical solver, an advanced adaptive controller known as MCSmd and a multi‐tasking strategy. The approach is evaluated through a series of experiments on discrete mass–spring systems. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

11.
Real‐time dynamic substructuring is an experimental technique for testing the dynamic behaviour of complex structures. It involves creating a hybrid model of the entire structure by combining an experimental test piece—the substructure—with a numerical model describing the remainder of the system. The technique is useful when it is impractical to experimentally test the entire structure or complete numerical modelling is insufficient. In this paper, we focus on the influence of delay in the system, which is generally due to the inherent dynamics of the transfer systems (actuators) used for structural testing. This naturally gives rise to a delay differential equation (DDE) model of the substructured system. With the case of a substructured system consisting of a single mass–spring oscillator we demonstrate how a DDE model can be used to understand the influence of the response delay of the actuator. Specifically, we describe a number of methods for identifying the critical time delay above which the system becomes unstable. Because of the low damping in many large structures a typical situation is that a substructuring test would operate in an unstable region if additional techniques were not implemented in practice. We demonstrate with an adaptive delay compensation technique that the substructured mass–spring oscillator system can be stabilized successfully in an experiment. The approach of DDE modelling also allows us to determine the dependence of the critical delay on the parameters of the delay compensation scheme. Using this approach we develop an over‐compensation scheme that will help ensure stable experimental testing from initiation to steady state operation. This technique is particularly suited to stiff structures or those with very low natural damping as regularly encountered in structural engineering. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

12.
Real‐time hybrid simulation (RTHS) is a powerful cyber‐physical technique that is a relatively cost‐effective method to perform global/local system evaluation of structural systems. A major factor that determines the ability of an RTHS to represent true system‐level behavior is the fidelity of the numerical substructure. While the use of higher‐order models increases fidelity of the simulation, it also increases the demand for computational resources. Because RTHS is executed at real‐time, in a conventional RTHS configuration, this increase in computational resources may limit the achievable sampling frequencies and/or introduce delays that can degrade its stability and performance. In this study, the Adaptive Multi‐rate Interface rate‐transitioning and compensation technique is developed to enable the use of more complex numerical models. Such a multi‐rate RTHS is strictly executed at real‐time, although it employs different time steps in the numerical and the physical substructures while including rate‐transitioning to link the components appropriately. Typically, a higher‐order numerical substructure model is solved at larger time intervals, and is coupled with a physical substructure that is driven at smaller time intervals for actuator control purposes. Through a series of simulations, the performance of the AMRI and several existing approaches for multi‐rate RTHS is compared. It is noted that compared with existing methods, AMRI leads to a smaller error, especially at higher ratios of sampling frequency between the numerical and physical substructures and for input signals with high‐frequency content. Further, it does not induce signal chattering at the coupling frequency. The effectiveness of AMRI is also verified experimentally. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
基于虚拟振动台的实时耦联动力仿真试验   总被引:1,自引:1,他引:0  
实时耦联动力试验(RTDHT)是一种将物理模型试验与数值求解计算实时耦联在一起的新型结构动力试验方法.本文采用SIMULINK对液压伺服振动台系统进行了仿真,建立虚拟振动台模型对真实振动台进行离线调试.并提出基于虚拟振动台进行实时耦联动力仿真试验,从而对真实实时耦联动力试验进行指导的思想.仿真结果表明,虚拟振动台可以很好地仿真真实振动台的动力特性,离线调试结果应用于真实振动台能够得到优良的控制性能;基于虚拟振动台的实时耦联动力仿真试验能够反映真实实时耦联动力试验中存在的时滞以及由此而可能导致的系统失稳问题.采用预测补偿算法对时滞进行了补偿,结果表明补偿算法消除了时滞的影响,试验系统稳定且试验结果与数值计算结果吻合得较好.基于虚拟振动台对实时耦联动力试验进行研究,既能对真实试验提出指导又可避免试验系统失稳对设备的损害,是一种实用且必要的研究手段.  相似文献   

14.
We present a comparison of methods for the analysis of the numerical substructure in a real‐time hybrid test. A multi‐tasking strategy is described, which satisfies the various control and numerical requirements. Within this strategy a variety of explicit and implicit time‐integration algorithms have been evaluated. Fully implicit schemes can be used in fast hybrid testing via a digital sub‐step feedback technique, but it is shown that this approach requires a large amount of computation at each sub‐step, making real‐time execution difficult for all but the simplest models. In cases where the numerical substructure poses no harsh stability condition, it is shown that the Newmark explicit method offers advantages of speed and accuracy. Where the stability limit of an explicit method cannot be met, one of the several alternatives may be used, such as Chang's modified Newmark scheme or the α‐operator splitting method. Appropriate methods of actuator delay compensation are also discussed. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

15.
In real‐time hybrid simulations (RTHS) that utilize explicit integration algorithms, the inherent damping in the analytical substructure is generally defined using mass and initial stiffness proportional damping. This type of damping model is known to produce inaccurate results when the structure undergoes significant inelastic deformations. To alleviate the problem, a form of a nonproportional damping model often used in numerical simulations involving implicit integration algorithms can be considered. This type of damping model, however, when used with explicit integration algorithms can require a small time step to achieve the desired accuracy in an RTHS involving a structure with a large number of degrees of freedom. Restrictions on the minimum time step exist in an RTHS that are associated with the computational demand. Integrating the equations of motion for an RTHS with too large of a time step can result in spurious high‐frequency oscillations in the member forces for elements of the structural model that undergo inelastic deformations. The problem is circumvented by introducing the parametrically controllable numerical energy dissipation available in the recently developed unconditionally stable explicit KR‐α method. This paper reviews the formulation of the KR‐α method and presents an efficient implementation for RTHS. Using the method, RTHS of a three‐story 0.6‐scale prototype steel building with nonlinear elastomeric dampers are conducted with a ground motion scaled to the design basis and maximum considered earthquake hazard levels. The results show that controllable numerical energy dissipation can significantly eliminate spurious participation of higher modes and produce exceptional RTHS results. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
Marginal wharves are key components in providing functionality of port facilities. Ports are central components of the US economy. Earthquake damage to a port can disrupt the economic stability. Therefore, port facilities must be able to quickly return to full operation shortly after a seismic event. Prior studies have shown that integrity of marginal wharves may be compromised by excessive soil movement and structural damage. The latter is often localized at pile‐to‐wharf connections and in the pile body buried within the soil. Recent research has resulted in an improved connection design that mitigates damage. This study was undertaken to evaluate the full seismic performance of marginal wharves including both conventional and damage‐resisting connections. A series of finite element models of a representative pile‐supported wharf facility were created. The models varied in their moment‐resisting pile‐to‐wharf connections. A total‐stress analysis approach was used to capture the soil response along with py, tz, and Qz soil–structure interaction springs. Validated connection interface elements were integrated with non‐linear frame elements to simulate the marginal wharf structure and substructure. Non‐linear static pushover and dynamic time history analyses, for three different hazard levels, were performed. The results of the numerical simulations were used to assess the performance of the marginal wharf including estimates of crane damage and port downtime. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
A variant of the Rosenbrock‐W integration method is proposed for real‐time dynamic substructuring and pseudo‐dynamic testing. In this variant, an approximation of the Jacobian matrix that accounts for the properties of both the physical and numerical substructures is used throughout the analysis process. Only an initial estimate of the stiffness and damping properties of the physical components is required. It is demonstrated that the method is unconditionally stable provided that specific conditions are fulfilled and that the order accuracy can be maintained in the nonlinear regime without involving any matrix inversion while testing. The method also features controllable numerical energy dissipation characteristics and explicit expression of the target displacement and velocity vectors. The stability and accuracy of the proposed integration scheme are examined in the paper. The method has also been verified through hybrid testing performed of SDOF and MDOF structures with linear and highly nonlinear physical substructures. The results are compared with those obtained from the operator splitting method. An approach based on the modal decomposition principle is presented to predict the potential effect of experimental errors on the overall response during testing. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
When subjected to long‐period ground motions, high‐rise buildings' upper floors undergo large responses. Furniture and nonstructural components are susceptible to significant damage in such events. This paper proposes a full‐scale substructure shaking table test to reproduce large floor responses of high‐rise buildings. The response at the top floor of a virtual 30‐story building model subjected to a synthesized long‐period ground motion is taken as a target wave for reproduction. Since a shaking table has difficulties in directly reproducing such large responses due to various capacity limitations, a rubber‐and‐mass system is proposed to amplify the table motion. To achieve an accurate reproduction of the floor responses, a control algorithm called the open‐loop inverse dynamics compensation via simulation (IDCS) algorithm is used to generate a special input wave for the shaking table. To implement the IDCS algorithm, the model matching method and the H method are adopted to construct the controller. A numerical example is presented to illustrate the open‐loop IDCS algorithm and compare the performance of different methods of controller design. A series of full‐scale substructure shaking table tests are conducted in E‐Defense to verify the effectiveness of the proposed method and examine the seismic behavior of furniture. The test results demonstrate that the rubber‐and‐mass system is capable of amplifying the table motion by a factor of about 3.5 for the maximum velocity and displacement, and the substructure shaking table test can reproduce the large floor responses for a few minutes. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
Real‐time pseudodynamic (PSD) and hybrid PSD test methods are experimental techniques to obtain the response of structures, where restoring force feedback is used by an integration algorithm to generate command displacements. Time delays in the restoring force feedback from the physical test structure and/or the analytical substructure cause inaccuracies and can potentially destabilize the system. In this paper a method for investigating the stability of structural systems involved in real‐time PSD and hybrid PSD tests with multiple sources of delay is presented. The method involves the use of the pseudodelay technique to perform an exact mapping of fixed delay terms to determine the stability boundary. The approach described here is intended to be a practical one that enables the requirements for a real‐time testing system to be established in terms of system parameters when multiple sources of delay exist. Several real‐time testing scenarios with delay that include single degree of freedom (SDOF) and multi‐degree of freedom (MDOF) real‐time PSD/hybrid PSD tests are analyzed to illustrate the method. From the stability analysis of the real‐time hybrid testing of an SDOF test structure, delay‐independent stability with respect to either experimental or analytical substructure delay is shown to exist. The conditions that the structural properties must satisfy in order for delay‐independent stability to exist are derived. Real‐time hybrid PSD testing of an MDOF structure equipped with a passive damper is also investigated, where observations from six different cases related to the stability plane behavior are summarized. Throughout this study, root locus plots are used to provide insight and explanation of the behavior of the stability boundaries. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
This paper presents the development and validation of a real‐time hybrid simulation (RTHS) system for efficient dynamic testing of high voltage electrical vertical‐break disconnect switches. The RTHS system consists of the computational model of the support structure, the physical model of the insulator post, a small shaking table, a state‐of‐the‐art controller, a data acquisition system and a digital signal processor. Explicit Newmark method is adopted for the numerical integration of the governing equations of motion of the hybrid structure, which consists of an insulator post (experimental substructure) and a spring‐mass‐dashpot system representing the support structure (analytical substructure). Two of the unique features of the developed RTHS system are the application of an efficient feed‐forward error compensation scheme and the ability to use integration time steps as small as 1 ms. After the development stage, proper implementation of the algorithm and robustness of the measurements used in the calculations are verified. The developed RTHS system is further validated by comparing the RTHS test results with those from a conventional shaking table test. A companion paper presents and discusses a parametric study for a variety of geometrical and material configurations of these switches using the developed RTHS system. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号