1.
The ‘Appropriate Sampling for Optimised Measurement’ (ASOM) approach considers measurement to be the focus of the sampling process, and sampling to be only the first part of the measurement process. To achieve ASOM, the uncertainty of measurements, including its contribution from sampling, needs to be estimated and optimised in order to achieve fitness‐for‐purpose. Such samples are then ‘sufficiently’ representative. The ‘Theory of Sampling’ (TOS) focuses on the processes of primary sampling and sample preparation and assumes that samples are ‘representative’ if they are correctly prepared by nominally ‘correct’ protocols. It defines around ten sampling ‘errors’, which are either modelled or minimised to improve sampling quality. It is argued that the ASOM approach is more effective in achieving appropriate measurement quality than in applying TOS to just the first part of the measurement process. The comparison is made less effective by the different objectives, scopes, terminology and assumptions of the two approaches. ASOM can be applied to in situ materials that are too variable to be modelled accurately, or where sources of uncertainty are unsuspected. The proposed integration of ASOM with TOS (Esbensen and Wagner 2014, Trends in Analytical Chemistry, 57, 93–106) is therefore effectively impossible. However, some TOS procedures can be useful within the ASOM approach.  相似文献   

2.
Measurements taken to characterise environmental contamination contain uncertainty, which is generated by both field sampling and chemical analyses. Recently devised techniques have been applied for the first time to estimate this uncertainty in the commercial monitoring and assessment of contaminated land. The uncertainty reduces the reliability of the classification of the land that is made following a site investigation. The possible misclassification of areas of land, as a result of measurement uncertainty, can lead to substantial financial penalties, resulting from litigation or unnecessary remediation. Previous studies have developed methods for the estimation and financial optimisation of measurement uncertainty. These methods have now been applied to a series of six contrasting site investigations, which were conducted by various commercial organisations. The previous uses of these sites included a gas works, a tin mine and railway sidings. The measurement uncertainty was successfully estimated for each of the six investigations, showing its applicability to a wide range of different sampling methods, such as trial pits, window sampling and augering. The measurement uncertainty ranged widely between sites from 25% to 158%, indicating that investigations can differ widely in their reliability. The field sampling tended to generate the largest component of the measurement uncertainty when compared to the contribution from the chemical analysis. The Optimised Contaminated Land Investigation (OCLI) method was applied to each site, with the initial aim of estimating the financial losses that could be incurred as a result of misclassifying the land, due to the uncertainty. It showed that the expectation of loss value per sampling location ranged from only £58 at one site to over £ 11 000 at another. The optimal level of uncertainty that produced the minimal financial loss was then calculated for each site. It provided a reduction in the expectation of loss for the whole site of over £ 10 000 at two of the sites and over £90 000 at two others. These findings demonstrate that implementing concepts of uncertainty can have practical benefits in environmental monitoring, and can enable improvements to be made in the quality of sampling and hence of measurements in general.  相似文献   

3.
Four silicate glasses were prepared by the fusion of about 1 kg powder each of a basalt, syenite, soil and andesite to provide reference materials of natural composition for microanalytical work. These glasses are referred to as ‘Chinese Geological Standard Glasses’ (CGSG) ‐1, ‐2, ‐4 and ‐5. Micro and bulk analyses indicated that the glasses are well homogenised with respect to major and trace elements. Some siderophile/chalcophile elements (e.g., Sn, Pt, Pb) may be heterogeneously distributed in CGSG‐5. This paper provides the first analytical data for the CGSG reference glasses using a variety of analytical techniques (wet chemistry, XRF, EPMA, ICP‐AES, ICP‐MS, LA‐ICP‐MS) performed in nine laboratories. Most data agree within uncertainty limits of the analytical techniques used. Discrepancies in the data for some siderophile/chalcophile elements exist, mainly because of possible heterogeneities of these elements in the glasses and/or analytical problems. From the analytical data, preliminary reference and information values for fifty‐five elements were calculated. The analytical uncertainties [2 relative standard error (RSE)] were estimated to be between about 1% and 20%.  相似文献   

4.
We report technical and data treatment methods for making accurate, high‐precision measurements of 18O/16O in Ca–Mg–Fe garnet utilising the Cameca IMS 1280 multi‐collector ion microprobe. Matrix effects were similar to those shown by previous work, whereby Ca abundance is correlated with instrumental mass fractionation (IMF). After correction for this effect, there appeared to be no significant secondary effect associated with Mg/Fe2+ for routine operational conditions. In contrast, investigation of the IMF associated with Mn‐ or Cr‐rich garnet showed that these substitutions are significant and require a more complex calibration scheme. The Ca‐related calibration applied to low‐Cr, low‐Mn garnet was reproducible across different sample mounts and under a range of instrument settings and therefore should be applicable to similar instruments of this type. The repeatability of the measurements was often better than ± 0.2‰ (2s), a precision that is similar to the repeatability of bulk techniques. At this precision, the uncertainties due to spot‐to‐spot repeatability were at the same magnitude as those associated with matrix corrections (± 0.1–0.3‰) and the uncertainties in reference materials (± 0.1–0.2‰). Therefore, it is necessary to accurately estimate and propagate uncertainties associated with these parameters – in some cases, uncertainties in reference materials or matrix corrections dominate the uncertainty budget.  相似文献   

5.
Trace elements from samples of bauxite deposits can provide useful information relevant to the exploration of the ore‐forming process. Sample digestion is a fundamental and critical stage in the process of geochemical analysis, which enables the acquisition of accurate trace element data by ICP‐MS. However, the conventional bomb digestion method with HF/HNO3 results in a significant loss of rare earth elements (REEs) due to the formation of insoluble AlF3 precipitates during the digestion of bauxite samples. In this study, the digestion capability of the following methods was investigated: (a) ‘Mg‐addition’ bomb digestion, (b) NH4HF2 open vessel digestion and (c) NH4F open vessel digestion. ‘Mg‐addition’ bomb digestion can effectively suppress the formation of AlF3 and simultaneously ensure the complete decomposition of resistant minerals in bauxite samples. The addition of MgO to the bauxite samples resulted in (Mg + Ca)/Al ratios ≥ 1. However, adding a large amount of MgO leads to significant blank contamination for some transition elements (V, Cr, Ni and Zn). The NH4HF2 or NH4F open vessel digestion methods can also completely digest resistant minerals in bauxite samples in a short period of time (5 hr). Unlike conventional bomb digestion with HF/HNO3, the white precipitates and the semi‐transparent gels present in the NH4HF2 and NH4F digestion methods could be efficiently dissolved by evaporation with HClO4. Based on these three optimised digestion methods, thirty‐seven trace elements including REEs in ten bauxite reference materials (RMs) were determined by ICP‐MS. The data obtained showed excellent inter‐method reproducibility (agreement within 5% for REEs). The relative standard deviation (% RSD) for most elements was < 6%. The concentrations of trace elements in the ten bauxite RMs showed agreement with the limited certified (Li, V, Cr, Cu, Zn, Ga, Sr, Zr and Pb) and information values (Co, Ba, Ce and Hf) available. New trace element data for the ten RMs are provided, some of which for the first time.  相似文献   

6.
A simple, rapid method for the determination of Re and Os concentrations and isotope compositions using isotope dilution multi‐collector inductively coupled plasma‐mass spectrometry (ID‐MC‐ICP‐MS) combined with Carius tube digestion and sparging introduction of Os was developed. For Os measurement, four channeltron ion counters to detect different Os isotopes were used simultaneously, which led to a drastic reduction in the measurement time. Rhenium isotopes were measured by means of eight Faraday cups with solution nebulisation and an ultrasonic membrane desolvator. The representative 188Os count rate of an Os standard solution containing 50 pg of total Os was approximately 110000–120000 cps at the onset of measurement; the Re intensity of our in‐house 10 pg g?1 standard solution reached 1820 V/μg g?1 with a sample uptake rate of 95–99 μl min?1. These values indicate that the sensitivity of the method was sufficient even for samples with low Re and Os concentrations, such as chert. As the temporal variations of the amplification efficiency of the ion counters differed from one another, we adopted a sample‐calibrator bracketing method to correct the measured Re and Os isotope ratios. The Re and Os concentrations via the isotope dilution method and the 187Os/188Os ratios of two sedimentary rock reference materials (JMS‐2 and JCh‐1) on the basis of the isotope ratios determined by the MC‐ICP‐MS and by negative thermal ionisation mass spectrometry (N‐TIMS) were comparable within their ranges. Based on Os isotope measurement of the IAG reference material [Durham Romil Os (DROsS)], the average difference from the recommended value and precision of Os isotope measurements by the sparging method in combination with multi‐ion‐counters were 0.72% and 0.76% [1RSD (%), n = 29], respectively. The precisions in the 187Os/188Os ratios [1RSD (%)] of JMS‐2, JCh‐1 and DROsS were 0.35–0.71, 1.56–3.31 and 0.99–1.28%, respectively, which depended on their Os ion intensities. No systematic difference was observed between the Re and Os geochemical compositions of JCh‐1 and JMS‐2 obtained by means of digestion with inverse aqua regia and CrO3‐H2SO4 solutions, suggesting that either acid solution can be used for the sparging method of sedimentary rock samples. As CrO3‐H2SO4 solution is believed to liberate predominantly the hydrogenous Re and Os fraction from organic‐rich sediment, the sparging method combined with CrO3‐H2SO4 digestion and multi‐ion‐counters in the mass spectrometry is expected to be a powerful tool for reconstructing the secular change in marine Os isotope compositions with high sample throughput.  相似文献   

7.
This study reports precise and accurate data for rare earth elements (REE) measured on eight geological reference materials, five enriched in REE (BE‐N, BHVO‐2, BR, BR‐24 and RGM‐1) and three very depleted in REE (BIR‐1, UB‐N and DTS‐2). Data were acquired by quadrupole ICP‐MS after isolation of the REE using an ion‐exchange chromatography procedure. All the measured REE abundances were similar within ≈ 5% (10% for the most REE‐depleted sample DTS‐2) to the high‐quality measurements previously published in the literature. We also show that by using an internal Tm spike, the reproducibility of the data was improved to ~ 1%. Applying this technique to the analysis of ultra‐depleted rock samples (sub ng g?1), we show that significant improvements were obtained relative to the routine trace element measurement method. The chondrite‐normalised patterns were smooth instead of displaying irregularities. Although the classical method gives excellent results on REE‐rich samples, we believe that our technique improves the precision and accuracy of measurements for highly REE‐depleted rocks.  相似文献   

8.
Measurements of sulfur stable isotope ratios (34S/32S) have suffered from technical difficulties in analysing low‐S materials reducing their use despite their undeniable scientific interest. The measurement of 34S/32S ratios is a powerful tool for deciphering problems such as determining the sources of environmental pollutants, to detect adulteration, tracking the evolution of the redox state of the oceans and quantifying the role of the bacterial activity in sulfide minerals genesis. We have used a high‐precision method of sulfur isotope determination using a new type of elemental analyser based on ‘purge and trap’ technology. This new technique demonstrates the high quality of 34S/32S measurements for samples with S concentrations lower than 1% m/m. International calibrated references of diverse sulfur‐bearing materials were used to calibrate two low (< 1%) S‐bearing phosphorites used as compositional reference material for future use as isotopic references: BCR 32 and NBS 120c. δ34SCDT values of, respectively, 18.2‰ (1s = 0.3; n = 23) and 18.3‰ (1s = 0.4; n = 20) are proposed for these. Calibration of both phosphorites with international reference materials led to calculation of a mean standard error close to 0.4‰. The demonstration of a capability to reliably measure S isotope ratios in low‐S phosphate minerals or rocks opens up new fields of palaeoenvironmental reconstructions.  相似文献   

9.
The International Atomic Energy Agency (IAEA) organised a proficiency test (PT), IAEA‐CU‐2010‐02, for the determination of elements in sewage sludge. The PT sample was analysed by semi‐absolute standardless k0‐instrumental neutron activation analysis (k0‐INAA). Results for seven elements (As, Co, Cr, Fe, Hg, Se, Zn) were submitted to the IAEA by our laboratory. All of our results were scored ‘acceptable’ by the ‘result evaluation criteria’ adopted by the IAEA. The same analytical methodology produced quantitative results for twenty‐six additional elements. In total, thirty‐six elements were determined with uncertainty varying from 4 to 11%. This paper presents the provisional mass fractions of twenty‐six additional elements (Ag, Al, Br, Ca, Ce, Cl, Dy, Eu, Ga, Hf, I, K, La, Mg, Mn, Na, Rb, Sb, Sc, Sm, Ta, Tb, Th, V, U, W) not reported by the IAEA. The analytical methodology was discussed with important sources of spectral, nuclear and fission‐product interferences. It was shown that the important components of uncertainties were the k0 factor, Q0 factor, detector efficiency, mass and counting statistics. The methodology was validated by analysing the IAEA‐S7 reference material.  相似文献   

10.
A range of independently characterised reference materials (RMs) for LA‐ICP‐MS, used for the determination of the platinum‐group elements (PGE) and Au in a sulfide matrix, were analysed and compared: 8b, PGE‐A, NiS‐3, Po727‐T1, Po724‐T and the Lombard meteorite. The newly developed RM NiS‐3 was used as the RM for the calibration of all LA‐ICP‐MS analyses and the measured concentrations of the other RMs compared against their published concentrations. This data were also used to assess the consistency of concentrations calibrated against the different RMs. It was found that Po727‐T1 and 8b produced results that were comparable, within uncertainty, for all elements. Po727‐T1 also produced consistent results with NiS‐3 for all elements. All other RMs showed differences for some elements, especially Ru in Po724‐T, and Os, Ir and Au in PGE‐A. The homogeneity of the PGE and Au in each RM was assessed, by comparing the precision of multiple LA‐ICP‐MS spot analyses with the average uncertainty of the signal. Po724‐T, Po727‐T1 and the Lombard meteorite were found to be homogeneous for all elements, but 8b, PGE‐A and NiS‐3 were heterogeneous for some elements. This is the first direct comparison between a range of independently characterised PGE and Au LA‐ICP‐MS RMs.  相似文献   

11.
A model is presented for estimating the value of information of sampling programs for contaminated soil. The purpose is to calculate the optimal number of samples when the objective is to estimate the mean concentration. A Bayesian risk–cost–benefit decision analysis framework is applied and the approach is design-based. The model explicitly includes sample uncertainty at a complexity level that can be applied to practical contaminated land problems with limited amount of data. Prior information about the contamination level is modelled by probability density functions. The value of information is expressed in monetary terms. The most cost-effective sampling program is the one with the highest expected net value. The model was applied to a contaminated scrap yard in Göteborg, Sweden, contaminated by metals. The optimal number of samples was determined to be in the range of 16–18 for a remediation unit of 100 m2. Sensitivity analysis indicates that the perspective of the decision-maker is important, and that the cost of failure and the future land use are the most important factors to consider. The model can also be applied for other sampling problems, for example, sampling and testing of wastes to meet landfill waste acceptance procedures.  相似文献   

12.
We document the development of a suite of carbonate mineral reference materials for calibrating SIMS determinations of δ18O in samples with compositions along the dolomite–ankerite solid solution series [CaMg(CO3)2–CaFe(CO3)2]. Under routine operating conditions for the analysis of carbonates for δ18O with a CAMECA IMS 1280 instrument (at WiscSIMS, University of Wisconsin‐Madison), the magnitude of instrumental bias along the dolomite–ankerite series decreased exponentially by ~ 10‰ with increasing Fe content in the dolomite structure, but appeared insensitive to minor Mn substitution [< 2.6 mol% Mn/(Ca+Mg+Fe+Mn)]. The compositional dependence of bias (i.e., the sample matrix effect) was calibrated using the Hill equation, which relates bias to the Fe# of dolomite–ankerite [i.e., molar Fe/(Mg+Fe)] for thirteen reference materials (Fe# = 0.004–0.789); for calibrations employing either 10 or 3 μm diameter spot size measurements, this yielded residual values ≤ 0.3–0.4‰ relative to CRM NBS 19 for most reference materials in the suite. Analytical precision was ± 0.3‰ (2s, standard deviations) for 10‐μm spots and ± 0.7‰ (2s) for 3‐μm spots, based on the spot‐to‐spot repeatability of a drift monitor material that ‘bracketed’ each set of ten sample‐spot analyses. Analytical uncertainty for individual sample analyses was approximated by a combination of precision and calibration residual values (propagated in quadrature), suggesting an uncertainty of ± 0.5‰ (2s) for 10‐μm spots and ± 1‰ (2s) for 3‐μm spots.  相似文献   

13.
This study is Part II of a series that documents the development of a suite of calibration reference materials for in situ SIMS analysis of stable isotope ratios in Ca‐Mg‐Fe carbonates. Part I explored the effects of Fe2+ substitution on SIMS δ18O bias measured from the dolomite–ankerite solid solution series [CaMg(CO3)2–CaFe(CO3)2], whereas this complementary work explores the compositional dependence of SIMS δ13C bias (calibrated range: Fe# = 0.004–0.789, where Fe# = molar Fe/(Mg+Fe)). Under routine operating conditions for carbonate δ13C analysis at WiscSIMS (CAMECA IMS 1280), the magnitude of instrumental bias increased exponentially by 2.5–5.5‰ (session‐specific) with increasing Fe‐content in the dolomite structure, but appeared insensitive to minor Mn substitution [< 2.6 mole % Mn/(Ca+Mg+Fe+Mn)]. The compositional dependence of bias (i.e., the matrix effect) was expressed using the Hill equation, yielding calibration residual values ≤ 0.3‰ relative to CRM NBS‐19 for eleven carbonate reference materials (6‐μm‐diameter spot size measurements). Based on the spot‐to‐spot repeatability of a drift monitor material that ‘bracketed’ each set of ten sample‐spot analyses, the analytical precision was ± 0.6–1.2‰ (2s, standard deviations). The analytical uncertainty for individual sample analyses was approximated by combining the precision and calibration residual values (propagated in quadrature), suggesting an uncertainty of ± 1.0–1.5‰ (2s).  相似文献   

14.
Geochemical reference materials (RMs) for microbeam techniques are typically characterised by averages and dispersion statistics (e.g., standard deviation, variance) that are calculated for a number of measurements (beam shots). It is proposed that the mapping of RMs will add spatial information that better characterises the grouping and magnitudes of the heterogeneities and provides the information necessary to define a minimum analytical mass. A simple mathematical solution is proposed, which can be easily computed and understood. The analogous notions to sill and range from geostatistics are applied to the minimum analytical mass versus the relative standard deviation. To assess grouping and magnitudes of the heterogeneities, a ‘proximity number’ is computed for each average value ± ‘n’ standard deviations (magnitude). Different chemical anomalies have been simulated to demonstrate the behaviour of the proximity number. To further test the proposed spatial geochemistry concept, sulfide‐ and oxide‐bearing RMs have been selected because many are crippled with nugget effect. They have been mapped with a micro‐XRF apparatus, and results are presented for CHR‐Bkg, CHR‐Pt+, MASS‐1, MASS‐3, WMS‐1 and WMS‐1a. MASS‐1 and MASS‐3 are the most suitable RMs for microbeam techniques. Spatial geochemistry offers a new approach to better characterise reference materials.  相似文献   

15.
A two‐step Th isolation protocol, involving micro‐columns of TRU‐Spec extraction chromatography material and AG1 resin, was evaluated. The MC‐ICP‐MS procedure included 232Th tailing characterisation and correction, and calibrator bracketing using an in‐house standard solution (ThS1) to correct for instrumental mass bias and Faraday cup to secondary electron multiplier relative gain. Repeated analyses of reference solutions (UCSC Th ‘A’, WUN, OU Th ‘U’, IRMM‐36) were consistent with published data. Six reference materials (A‐THO, BCR‐2, AGV‐2, BHVO‐2, BE‐N and BIR‐1) were processed. The average 230Th/232Th values obtained for these samples are in excellent agreement with published data. In addition, we report the first 230Th/232Th values for BE‐N and BIR‐1. The intermediate precisions for rock samples ranged from ± 0.24 to ± 0.49% (2 RSD) and were similar to those achieved for synthetic solutions, thereby supporting the overall validity of the chemical separation, data acquisition and reduction procedures. Counting statistics on the 230Th isotope was the most significant source of uncertainty. The intermediate precision of the mean 230Th/232Th for the Th‐depleted BIR‐1 (5.64 × 10?6 ± 0.27%, 2 RSD) is in the range of the analyses of other reference materials analysed in this study.  相似文献   

16.
A proposal is set out for the information and details that should accompany the publication of geochemical data in the research literature. This proposal is based on the principle that sufficient detail must be included both to allow independent replication of the results and for reviewers to confirm that data are fit‐for‐purpose in supporting the way in which they have been interpreted. In particular, it is recommended that all analytical measurements should be accompanied by an estimate of uncertainty that includes both field sampling and laboratory contributions together with a statement that summarises the way published data conform to the principles of traceability.  相似文献   

17.
The IAG conducts two programmes, the GeoPT ? proficiency test and a certification programme that are closely interconnected. Both support the quality control/quality assurance activities of geochemical laboratories. Each derives an estimate of ‘true value’ for a number of samples, but arrives at that estimate, and its uncertainty, differently. This review discusses the history of the two programmes and compares the ‘true values’ and their uncertainties obtained through each. It then considers ‘fitness‐for‐purpose’ issues related to both GeoPT ? and certification uncertainties. Issues related to potential modification of the IAG protocol for certification are also considered.  相似文献   

18.
With implications for the origin of ore deposits, redox state of the atmosphere, and effects of volcanic outgassing, understanding the sulfur cycle is vital to our investigation of Earth processes. However, the paucity of sulfur concentration measurements in silicate rocks and the lack of well‐calibrated reference materials with concentrations relevant to the rocks of interest have hindered such investigations. To aid in this endeavour, this study details a new method to determine sulfur concentration via high mass resolution solution inductively coupled plasma‐mass spectrometry (ICP‐MS). The method is based on an aqua regia leach, involving relatively rapid sample preparation and analysis, and uses small test portion masses (< 50 mg). We utilised two independently prepared standard solutions to calibrate the analyses, resulting in 4% accuracy, and applied the method to eight geochemical reference materials. Measurements were reproducible to within ~ 10%. Sulfur concentrations and isotopes of six reference materials were measured additionally by elemental analyser‐combustion‐isotope ratio mass spectrometry to independently evaluate the accuracy of the ICP‐MS method. Reference materials that yielded reproducible measurements identical to published values from other laboratories (JGb‐1, JGb‐2 and MAG‐1) are considered useful materials for the measurement of sulfur. Reference materials that varied between studies but were reproducible for a given test portion perhaps suffer from sample heterogeneity and are not recommended as sulfur reference materials.  相似文献   

19.
Excellent agreement was noted in the concentration of major and trace elements in five NIST (National Institute for Science and Technology) soil reference materials (NIST SRM 2586, 2587, 2709a, 2710a and 2711a) between measurement results from wavelength dispersive‐XRF and ICP‐MS from two independent laboratories, and NIST certificate of analysis and literature data. We describe the variability in concentrations of up to forty‐nine elements (plus loss on ignition) and provide values for up to twenty‐one elements previously uncharacterised by NIST in these soil RMs. The additional characterisation provided in this investigation can be utilised to reduce the measurement bias of custom calibration routines and improve the quality of control checks developed using these NIST RMs.  相似文献   

20.
A statistical evaluation of the results of geochemical analyses of geothermal waters during interlaboratory comparison programmes of the International Association of Geochemistry and Cosmochemistry (IAGC) and International Atomic Energy Agency (IAEA) was performed to estimate the uncertainty of measurement of pH, electrical conductivity, Na+, K+, Ca2+, Mg2+, Li+, Cl?, HCO3?, SO42?, SiO2 and B. The uncertainty of measurement was found to increase exponentially with decrease in value (concentration) for all the parameters except for pH, electrical conductivity and SiO2 and was of the same order of magnitude as the concentrations for values of less than 1 μ ml?1. There was an overall uncertainty of ± 2.5% in the measurement of pH and ± 30% in SiO2. For all the other chemical species the uncertainty data were modelled by exponential curves. The sample IAEA14 was prepared by dissolving commercial reagents (i.e., represents a solution of known composition). Thus, the calculated values are considered to be the conventional true values for each chemical parameter. The difference between the measured mean of the data submitted by participating laboratories and the conventional true value for each parameter (i.e., bias of submitted measurements) for the species Na+, K+, Ca2+, Mg2+, Cl? and SO42? was ‐3.5, ‐1.1, ‐13.3, ‐53.6, ‐12.6 and ‐86.6%, respectively. The observed bias was of the same order of magnitude as statistical fluctuations (1s) for Na+ and K+, but significantly higher for Ca2+, Mg2+, Cl? and SO42?. Two methods, uncertainty interval and GUM (“guide to the expression of uncertainty of measurement”) were used to propagate uncertainty in the pH calculation of geothermal reservoir fluid. The application of the methods is illustrated by considering the IAEA10 and IAEA11 samples analysed in the interlaboratory comparisons as separated geothermal waters at atmospheric pressure.  相似文献   