首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A retrofitting technology using precast steel reinforced concrete (PSRC) panels is developed to improve the seismic performance of old masonry buildings. The PSRC panels are built up as an external PSRC wall system surrounding the existing masonry building. The PSRC walls are well connected to the existing masonry building, which provides enough confinement to effectively improve the ductility, strength, and stiffenss of old masonry structures. The PSRC panels are prefabricated in a factory, significantly reducing the situ work and associated construction time. To demonstrate the feasibility and mechanical effectivenss of the proposed retrofitting system, a full-scale five-story specimen was constructed. The retrofitting process was completed within five weeks with very limited indoor operation. The specimen was then tested in the lateral direction, which could potentially suffer sigifnicant damage in a large earthquake. The technical feasibility, construction workability, and seismic performance were thoroughly demonstrated by a full-scale specimen construction and pseudo-dynamic tests.  相似文献   

2.
首先介绍了CFRP加固受损钢筋混凝土柱的数值模拟方法,通过OpenSees软件进行了建模分析,数值模拟结果与试验结果的对比验证了该数值模型的有效性;其次,对一6层钢筋混凝土框架以受极罕遇地震影响进行预损,采用损伤指数和折减系数的方法建立震损钢筋混凝土框架的分析模型,并选择5种不同的CFRP加固方案对其进行加固;最后,对CFRP加固的震损RC框架进行增量动力分析。定量的评价了CFRP加固震损RC框架的抗整体性倒塌能力和抗倒塌安全储备。结果表明:CFRP加固能有效提高震损钢筋混凝土框架结构的抗震性能。加固部位的选择对加固效果的影响很大,在所选用的5种CFRP加固方案中,对底层及第2层的梁柱进行加固的方案对提高震损钢筋混凝土框架的抗整体性倒塌能力效果最佳。  相似文献   

3.
This study describes the seismic performance of an existing five storey reinforced concrete building which represents the typical properties of low-rise non-ductile buildings in Turkey. The effectiveness of shear walls and the steel bracings in retrofitting the building was examined through nonlinear static and dynamic analyses. By using the nonlinear static analysis, retrofitted buildings seismic performances under lateral seismic load were compared with each other. Moreover, the performance points and response levels of the existing and retrofitting cases were determined by way of the capacity-spectrum method described in ATC-40 (1996). For the nonlinear dynamic analysis the records were selected torepresent wide ranges of duration and frequency content. Considering the change in the stiffness and the energy dissipation capacities, the performance of the existing and retrofitted buildings were evaluated in terms of story drifts and damage states. It was found that each earthquake record exhibited its own peculiarities, dictated by frequency content, duration, sequence of peaks and their amplitude. The seismic performance of retrofitted buildings resulted in lower displacements and higher energy dissipation capacity depending mainly on the properties of the ground motions and the retrofitting strategies. Moreover, severe structural damage (irreparable or collapse) was observed for the existing building. However, buildings with retrofit alternatives exhibited lower damage levels changing from no damage to irreparable damage states.  相似文献   

4.
Building structures damaged by a seismic event may be exposed to the risk of aftershocks or another event within a certain period. In this paper, the seismic assessment of damaged piloti‐type RC buildings was carried out to evaluate probabilistic retrofitting effects under successive earthquakes. First, a framework to evaluate the effectiveness of retrofitting was proposed, and then the proposed methodology was demonstrated with a structure retrofitted with buckling‐restrained braces (BRBs). For consideration of realistic successive earthquakes, past records measured at the same station were combined. Within the framework, a series of nonlinear time history analyses were performed for an as‐is model subjected to single earthquake, a damaged model subjected to successive earthquakes, and a damaged model retrofitted with BRBs subjected to successive earthquakes. In addition, fragility analysis was systematically applied in the framework for evaluation of effectiveness of the retrofitting strategy. The proposed framework was capable of quantifying the influence of successive earthquakes and evaluating the effectiveness of BRB retrofitting by considering the severity of the first earthquake damage and the hysteresis behavior of the retrofit element. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
Large number of vulnerable reinforced concrete (RC) buildings exists in earthquake prone areas. These low cost residential and/or commercial buildings, which are three to seven-stories high, usually do not receive essential engineering services during the construction phase. Finding cheap, easily applicable and occupant friendly retrofitting techniques are extremely important to reduce the seismic risk of these buildings. As an attempt to this, a particular type of high strength clay brick is studied to evaluate its potential for the structural retrofitting. A set of experiment was conducted to assess the important mechanical characteristics of the infill walls made from these bricks. Also the performance of two RC frames retrofitted with these walls, having different connection details between the wall and RC members was examined experimentally. The analytical nonlinear static analyses of these specimens have been performed using SeismoStruct to achieve some model parameters for representing the “infill wall model” in the program. Adaptive pushover and nonlinear time history analyses were conducted to investigate the performance of a six storey representative RC frame retrofitted with these walls. Evaluation of the results obtained in these analyses prove that this retrofitting technique introduces important strength and stiffness increments to the structure, regarding its seismic demands, which are similar to the results obtained from the experiments.  相似文献   

6.
The collapse of stone masonry is one of the greatest causes of death in major earthquake events around the world. This paper investigates a recently developed retrofitting technology specifically aimed at preventing or prolonging the collapse of stone masonry buildings under strong earthquakes. This technology uses common polypropylene packaging straps to form a mesh, which is then used to prevent or prolong collapse. This paper examines the findings from static and dynamic testing of the proposed retrofit. It is shown that the proposed technique effectively prevents brittle masonry collapse and the loss of debris.  相似文献   

7.
为研究碳纤维布加固严重破坏砌体墙的有效性,开展了4片严重破坏墙体的碳纤维布加固试验,研究了试件在低周反复荷载作用下的试验性能,考查了其破坏形态和破坏特征,对比分析了墙体的承载力、延性和耗能能力等性能。研究表明:采用粘贴碳纤维布加固严重破坏墙体的方法是可行且有效的;加固后墙体的抗剪承载力、变形性能都较原墙墙体有明显提高;碳纤维布布置方法不同,对墙体的约束效果不同;碳纤维布破坏时其应变远小于其极限抗拉应变,建议碳纤维布加固严重破坏墙体时无须使用高强度的碳纤维布。  相似文献   

8.
Yang  Cantian  Xie  Linlin  Li  Aiqun  Zeng  Demin  Jia  Junbo  Chen  Xi  Chen  Min 《地震工程与工程振动(英文版)》2020,19(4):839-853

The improvement of the seismic resilience of existing reinforced-concrete (RC) frame buildings, which is essential for the seismic resilience of a city, has become a critical issue. Although seismic isolation is an effective method for improving the resilient performance of such buildings, target-oriented quantitative improvements of the resilient performance of these buildings have been reported rarely. To address this gap, the seismic resilience of two existing RC frame buildings located in a high seismic intensity region of China were assessed based on the Chinese Standard for Seismic Resilience Assessment of Buildings. The critical engineering demand parameters (EDPs) affecting the seismic resilience of such buildings were identified. Subsequently, the seismic resilience of buildings retrofitted with different isolation schemes (i.e., yield ratios) were evaluated and compared, with emphasis on the relationships among yield ratios, EDPs, and levels of seismic resilience. Accordingly, to achieve the highest level of seismic resilience with respect to the Chinese standard, a yield ratio of 3% was recommended and successfully applied to the target-oriented design for the seismic-resilience improvement of an existing RC frame building. The research outcome can provide an important reference for the resilience-based retrofitting of existing RC frame buildings using seismic isolation in urban cities.

  相似文献   

9.
The 2014 magnitude 6.5 Ludian earthquake caused a death toll of 617, many landslides and tens of thousands of collapsed buildings. A field investigation to evaluate the damage to buildings was carried out immediately after the occurrence of the earthquake. Severely damaged aseismic buildings, which were basically observed in the downtown of Longtoushan Town, were carefully examined one by one with the aim to improve design codes. This paper summarizes the damage observed to the investigated aseismic buildings in both the structural and local levels. A common failure mode was observed that most of the aseismic buildings, such as RC frame structures and confined masonry structures, were similarly destroyed by severe damage or complete collapse of the first story. The related strong ground motion, which was recorded at the nearby station, had a short duration of less than 20 s but a very large PGA up to 1.0 g. The RC frames based on the new design codes still failed to achieve the design target for "strong column, weak beam". Typical local failure details, which were related to the interaction between RC columns and infill walls and between constructional columns and masonry walls, are summarized with preliminary analyses.  相似文献   

10.
The outline and typical characteristics of damages to building in Jiangyou city and Anxian county (intensity Ⅷ), Mianyang city and Deyang city (intensity Ⅶ) are introduced in the paper. The damage ratios, based on the sample statistics of multi-story brick buildings together with multi-story brick buildings with RC frame at first story (BBF), are presented. Then some typical damages, such as horizontal cricks of brick masonry buildings, Ⅹ-shaped cricks on the walls under windows, the damages to columns, beams and infill walls of frame buildings and the damage to half circle-shaped masonry walls, are discussed.  相似文献   

11.
Thousands of buildings were damaged by the devastating Chi‐Chi earthquake on September 21, 1999. Of all the public buildings, school buildings are the most vulnerable to earthquake damage, and the retrofitting of existing school buildings becomes a stringent issue. In addition to cost effectiveness, the impact of retrofitting methods on the functions of the school buildings needs to be considered. This paper therefore proposes the retrofitting of school buildings by adding sandwich columns onto partition brick walls. The sandwich column is divided into two parts and is added to the two sides of the partition brick wall held with pairs of U‐shaped bars. The retrofit does not require the removal of windows or doors in the longitudinal direction making the proposed method cost effective and minimizes the impact on the function of the school buildings. Five full‐scale specimens without and with retrofitting were designed and fabricated for testing based on the partition brick wall frames of the existing school buildings. The specimens were subjected to cyclic loading in the out‐of‐plane direction through a loading frame so that the columns deformed with double curvatures. The experimental results verified the feasibility of the proposed retrofit method. The data showed that the lateral strength of the retrofitted specimen doubled that which was not and that the residual strength of the retrofitted specimen was just as high as the ultimate strength of the specimen without retrofitting. The analytical results in lateral strength yielded conservative figures compared with experimental measurements. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
The Himalayan region is one of the major seismic areas in the world. However, similar to many other seismically active locations, there are substantial numbers of unreinforced masonry(URM) buildings; the majority of which have not been designed for seismic loads. Past seismic events have shown that such buildings are highly vulnerable to earthquakes. Retrofitting of these URM buildings is an important concern in earthquake mitigation programs. Most government school buildings in rural areas of northern India are constructed of unreinforced masonry. These school buildings are socially important structures and serve as a crucial resource for rehabilitation during any disaster. The effectiveness of ferrocement(FC) to create a URM-FC composite is described in this study by estimating the performance and fragility of a URM school building before and after a retrofit. Analytical models, based on the equivalent frame method, are developed and used for nonlinear static analysis to estimate the enhancement in capacity. The capacity enhancement due to retrofitting is presented in terms of the maximum PGA sustained and damage probabilities at the expected level of earthquake hazard.  相似文献   

13.
综述了用于提高填充墙钢筋混凝土(RC)框架结构抗震性能和改善结构损伤模式的几类加固措施,从工艺、加固效果和破坏形式3个角度进行了分析.在建筑结构设计过程中,填充墙通常被视为一种典型的脆性非均质非结构构件,忽视了填充墙与RC框架之间的相互作用.地震调查报告表明,在结构遭受地震作用时,填充墙通常先于钢筋混凝土框架发生破坏,...  相似文献   

14.
Experimental tests have shown that unreinforced masonry (URM) infill walls are affected by simultaneous loading in their in-plane and out-of-plane directions, but there have been few attempts to represent this interaction in nonlinear time history analysis of reinforced concrete (RC) buildings with URM infill walls. In this paper, a recently proposed macro-model that accounts for this interaction is applied to the seismic analysis of RC framed structures with URM infill walls representative of Mediterranean building stock and practices. Two RC framed structures that are representative of low and mid-rise residential buildings are analysed with a suite of a bidirectional ground motions, scaled to three different intensities. During the analyses, the in-plane/out-of-plane interaction is monitored, showing that cracking of the infills occurs predominantly by in-plane actions, while failure occurs due to a combination of in-plane and out-of-plane displacements, with the out-of-plane component usually playing the dominant role. Along the frame height, the bottom storeys are generally the most damaged, especially where thin infill walls are used. These results are consistent with observations of damage to URM infill walls in similar buildings during recent earthquakes.  相似文献   

15.
This paper presents results from a numerical investigation into the seismic retrofit of a soft story frame using a novel gapped‐inclined brace (GIB) system. The GIB system consists of a pinned brace and a gap element that is added to the first story columns of the frame. The inclusion of GIB elements in addition to increasing the lateral capacity of columns at the first story increases the post‐yield stiffness ratio of the system and reduces the P‐delta effects on the columns, while not increasing the first story lateral resistance or stiffness. This allows for the isolating benefits of the soft story to protect the upper floors of the structure from damage while avoiding excessive deformations and reducing the propensity for collapse. A six‐story RC frame with masonry infills on all floors except for the first floor is studied. The dynamic response of the retrofitted building using the GIB system is investigated numerically and is compared with the response of the original un‐retrofitted building and the same building in which masonry infills are added to the first story to mitigate the soft story response. Results from the nonlinear time‐history analyses indicate that the GIB system could provide a reliable seismic retrofit mechanism for soft story buildings, which greatly reduces the likelihood of collapse by increasing the displacement capacity of the soft storey and by reducing P‐delta effects, while minimizing the overall damage and losses in the building by taking advantages of the isolation that is provided by the soft story to the rest of the structure located above. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
为研究在结构前纵墙底层部位增设翼柱对底商多层砌体房屋抗倒塌性能的影响,分别设计了一个1/5缩尺比例的普通底商多层砌体房屋及增设翼柱的砌体房屋模型分别进行振动台试验研究,对比分析各模型的破坏过程、加速度放大系数、相对位移及典型位置应变等参数。结果表明,在同样的地震动输入下,带有翼柱的底商多层砌体房屋破坏程度、层间相对位移及层间位移角均明显低于普通底商多层砌体房屋,带有翼柱的底商多层砌体房屋抗倒塌性能显著提高。  相似文献   

17.
Recent major earthquakes around the world have evidenced that research in earthquake engineering must be directed to the vulnerability assessment of existing constructions lacking appropriate seismic resisting characteristics. Their retrofit or replacement should be made in order to reduce vulnerability, and consequent risk, to currently accepted levels. In this work, the efficiency of ductile steel eccentrically-braced systems in the seismic retrofitting of existing reinforced concrete (RC) buildings is studied. The retrofit technique studied consists in a bracing system with an energy dissipation device, designed to dissipate energy by shear deformation. The numerical model was calibrated with cyclic test results on a full-scale structure. The models used for the RC frame and masonry represent their real behavior and influence in the global structural response. The steel bracing system was modeled with strut rigid elements. The model for the energy dissipater device reproduces rigorously the behavior of the shear-link observed in the cyclic tests, namely in terms of shear, drift and energy dissipation. With the calibrated numerical model, a series of non-linear dynamic analyses were performed, for different earthquake input motions, intending to study: the influence of the retrofitting system in the response of bare and infilled structures; the influence of the location and strength of the retrofitting system.  相似文献   

18.
One of the main challenges in earthquake risk mitigation is the assessment of existing buildings not designed according to modern codes and the development of effective techniques to strengthen these structures. Particular attention should be given to RC frame structures with masonry infill panels, as demonstrated by their poor performance in recent earthquakes in Europe. Understanding the seismic behaviour of masonry‐infilled RC frames presents one of the most difficult problems in structural engineering. Analytical tools to evaluate infill–frame interaction and the failure mechanisms need to be further studied. This research intends to develop a simplified macro‐model that takes into account the out‐of‐plane behaviour of the infill panels and the corresponding in‐plane and out‐of‐plane interaction when subjected to seismic loadings. Finally, a vulnerability assessment of an RC building will be performed in order to evaluate the influence of the out‐of‐plane consideration in the building response. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
This paper discusses on the shaking table test results of two 1:4 scale model of two-story masonry structure typically used in constructing low-rise residential buildings. This test is performed to provide a better understanding of the seismic behavior of the PP-band (polypropylene band) mesh retrofitted adobe masonry house. The test structure is subjected to a series of different levels of harmonic motion that applied along the longitudinal direction. The results of the shaking table tests on building models show that the PP-band retrofitting technique can enhance the safety of masonry buildings, even during severe ground motion.  相似文献   

20.
In a seismically active region, structures may be subjected to multiple earthquakes, due to mainshock–aftershock phenomena or other sequences, leaving no time for repair or retrofit between the events. This study quantifies the aftershock vulnerability of four modern ductile reinforced concrete (RC) framed buildings in California by conducting incremental dynamic analysis of nonlinear MDOF analytical models. Based on the nonlinear dynamic analysis results, collapse and damage fragility curves are generated for intact and damaged buildings. If the building is not severely damaged in the mainshock, its collapse capacity is unaffected in the aftershock. However, if the building is extensively damaged in the mainshock, there is a significant reduction in its collapse capacity in the aftershock. For example, if an RC frame experiences 4% or more interstory drift in the mainshock, the median capacity to resist aftershock shaking is reduced by about 40%. The study also evaluates the effectiveness of different measures of physical damage observed in the mainshock‐damaged buildings for predicting the reduction in collapse capacity of the damaged building in subsequent aftershocks. These physical damage indicators for the building are chosen such that they quantify the qualitative red tagging (unsafe for occupation) criteria employed in post‐earthquake evaluation of RC frames. The results indicated that damage indicators related to the drift experienced by the damaged building best predicted the reduced aftershock collapse capacities for these ductile structures. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号