首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 25 毫秒
1.
针对波浪能转换装置(WEC)研究重点主要集中在能量捕获效率方面,而忽略其附带的消波功能的问题。基于Open FOAM程序,建立垂荡浮子式波浪能发电装置与桩式约束的浮式防波堤的集成系统(OBC-FB)。主要研究WEC中的重要组件动力输出系统(PTO)对集成系统波能捕获效率及消波性能的影响。分析流体黏性影响下线性PTO系统的最优PTO阻尼特性。开发非线性电磁阻尼模型与线性PTO系统性能进行比较。结果显示,考虑黏性影响下线性的最优PTO阻尼系数略大于无黏的理论值;适当增大PTO阻尼系数可以获得更大的波能捕获宽度比(CWR),从而可以保证装置单位特征尺寸的波能转换效率更高,同时可以在更宽波况范围保证消波性能;相较于线性PTO阻尼系统,非线性电磁PTO阻尼系统可以更好地兼顾波能捕获效率和消波性能。因此,在OBC-FB集成系统的优化设计中,PTO阻尼系统是一个重要的优化参数。  相似文献   

2.
Raft-type wave energy converter (WEC) is a multi-mode wave energy conversion device, using the relative pitch motion to drive its hydraulic power take-off (PTO) units for capturing energy from the ocean waves. The hydraulic PTO unit as its energy conversion module plays a significant role in storing large qualities of energy and making the output power smooth. However, most of the previous investigations on the raft-type WECs treat the hydraulic PTO unit as a linear PTO unit and do not consider the dynamics of the hydraulic circuit and components in their investigations. This paper is related to a two-raft-type WEC consisting of two hinged rafts and a hydraulic PTO unit. The aim of this paper is to make an understanding of the dynamics of the hydraulic PTO unit and how these affect the performance of the two-raft-type WEC. Therefore, a combined hydrodynamic and hydraulic PTO unit model is proposed to investigate and optimize the performance of the two-raft-type WEC; and based on the simulation of the combined model, the relationships between the optimal power capture ability, the optimal magnitude of the hydraulic PTO force and the wave states are numerically revealed. Results show that an approximately square wave type hydraulic PTO force is produced by the hydraulic PTO unit, which causes the performance of the two-raft-type WEC not to be sinusoidal and the energy capturing manner different from that of the device using a linear PTO unit; moreover, there is an optimal magnitude of the hydraulic PTO force for obtaining an optimal power capture ability, which can be achieved by adjusting the parameters of the hydraulic PTO unit; in regular waves, the optimal power capture ability as well as the optimal magnitude of the hydraulic PTO force normalized by the wave height presents little relationship with the wave height, mainly depends on the wave period; in irregular waves, the trends of the optimal power capture ability and the normalized optimal magnitude of the hydraulic PTO force against the peak wave periods at different significant wave heights are generally identical and show a good correlation. All means that the hydraulic PTO unit of the two-raft-type WEC can be tuned to the wave states, and these would provide a valuable guidance for the optimal design of its hydraulic PTO unit.  相似文献   

3.
波浪能发电装置的波能转换通常分为两级能量转换:第一级能量转换是波浪作用下波浪能装置部件发生相对运动驱动PTO做功捕获波浪能;第二级能量转换为将捕获的波浪能转换为电能。其中一级波浪能转换系统的优化设计是提高波浪能装置能量转换效率的重要手段和关键技术。波浪作用下波浪能装置的运动与PTO做功运动相互耦合和影响,本文通过对不同波浪要素环境下、不同PTO阻尼下波浪能装置的频域运动模拟,以迎波宽度比为尺度对波浪能装置的一级能量转换系统进行优化设计,获得波浪能装置的最优做功阻尼,为实型装置负载加载设计提供设计依据,提高波浪能装置能量转化效率。鹰式一号波浪能装置的实海况运动证明,通过对一级能量转换系统的优化设计,能够有效提高装置的发电效率和提高装置对波浪响应频带宽度。  相似文献   

4.
Compared with solar and wind energy, wave energy is a kind of renewable resource which is enormous and still under development. In order to utilize the wave energy, various types of wave energy converters (WECs) have been proposed and studied. And oscillating-body WEC is widely used for offshore deployment. For this type of WEC, the oscillating motion of the floater is converted into electricity by the power take off (PTO) system, which is usually mathematically simplified as a linear spring and a damper. The linear PTO system is characteristic of frequency-dependent response and the energy absorption is less powerful for off resonance conditions. Thus a nonlinear snap through PTO system consisting of two symmetrically oblique springs and a linear damper is applied. A nonlinear parameter γ is defined as the ratio of half of the horizontal distance between the two oblique springs to the original length of both springs. JONSWAP spectrum is utilized to generate the time series of irregular waves. Time domain method is used to establish the motion equation of the oscillating-body WEC in irregular waves. And state space model is applied to replace the convolution term in the time domain motion equation. Based on the established motion equation, the motion response of both the linear and nonlinear WEC is numerically calculated using 4th Runge–Kutta method, after which the captured power can be obtained. Then the influences of wave parameters such as peak frequency, significant wave height, damping coefficient of the PTO system and the nonlinear parameter γ on the power capture performance of the nonlinear WEC is discussed in detail. Results show that compared with linear PTO system, the nonlinear snap through PTO system can increase the power captured by the oscillating body WEC in irregular waves.  相似文献   

5.
Wave Energy Converters (WECs) have excellent potential as a source of renewable energy that is yet to be commercially realised. Recent attention has focused on the installation of Oscillating Water Column (OWC) devices as a part of harbor walls to provide advantages of cost–sharing structures and proximity of power generation facilities to existing infrastructure. In this paper, an incompressible three–dimensional CFD model is constructed to simulate a fixed Multi–Chamber OWC (MC–OWC) device. The CFD model is validated; the simulation results are found to be in good agreement with experimental results obtained from a scale physical model tested in a wave tank. The validated CFD model is then used for a benchmark study of 96 numerical tests. These investigate the effects of the PTO damping caused by the power take–off (PTO) system on device performance. The performance is assessed for a range of regular wave heights and periods. The results demonstrate that a PTO system with an intermediate damping can be used for all chambers in the MC–OWC device for most wave period ranges, except for the long wave periods. These require a higher PTO damping. An increased incident wave height reduces the device capture width ratio, but there is a noticeable improvement for long wave periods.  相似文献   

6.
This paper presents a nonlinear frequency domain model and uses this to assess the performance of a wave energy converter (WEC) array with a nonlinear power take-off (PTO). In this model, the nonlinear PTO forces are approximated by a truncated Fourier series, while the dynamics of the WEC array are described by a set of linear motion equations in the frequency domain, and the hydrodynamic coefficients are obtained with the boundary element method. A single heave absorber is firstly investigated to establish the accuracy of the new model in capturing the nonlinear behaviour of the pumping system. Subsequently, simulations of a 2D array with 18 WECs and a pillar in the centre (representing the tower of a wind turbine) are carried out to understand wave interference effects. Several optimisation strategies are proposed to improve the overall performance of the WEC array. These results demonstrate a computationally effective method for accounting for nonlinear effects in large WEC arrays. The proposed approach may potentially be applied for developing control algorithms for the adaptability of a 2D array to incoming wave excitation.  相似文献   

7.
The hydrodynamic performance of a bottom-hinged flap wave energy converter(WEC) is investigated through a frequency domain numerical model.The numerical model is verified through a two-dimensional analytic solution,as well as the qualitative analysis on the dynamic response of avibrating system.The concept of "optimum density" of the bottom-hinged flap is proposed,and its analytic expression is derived as well.The frequency interval in which the optimum density exists is also obtained.The analytic expression of the optimum linear damping coefficient is obtained by a bottom-hinged WEC.Some basic dynamic properties involving natural period,excitation moment,pitch amplitude,and optimum damping coefficient are analyzed and discussed in detail.In addition,this paper highlights the analysis of effects on the conversion performance of the device exerted by some important parameters.The results indicate that "the optimum linear damping period of 5.0 s" is the most ideal option in the short wave sea states with the wave period below 6.0 s.Shallow water depth,large flap thickness and low flap density are advised in the practical design of the device in short wave sea states in order to maximize power capture.In the sea state with water depth of 5.0 m and wave period of 5.0 s,the results of parametric optimization suggest a flap with the width of 8.0 m,thickness of 1.6 m,and with the density as little as possible when the optimum power take-off(PTO) damping coefficient is adopted.  相似文献   

8.
The double-body heave wave energy converter(WEC) is one of the most conducive devices to absorb the wave energy from relative motion while the law of which is not well understood. This paper makes an in-depth study on this wave energy converter, by means of the combination of theoretical analysis and physical model experiment. The hydrodynamic characteristics and energy capture of the double-buoy under constant and linear Power Take-Off(PTO) damping are investigated. Influences of absolute mass and mass ratio are discussed in the theoretical model.Relative displacement amplitude and average power output are tested in the experiment to analyze the effect of the wave period and outer buoy's mass, while the capture width ratio(CWR) is also calculated. Results show that the wave period and mass of the buoys have a significant effect on the converter. Different forms of PTO damping have no influence on the optimal wave period and mass ratio of this device. It is recommended to select the double-buoy converter with a mass ratio of 0.80 and to place it in an area with the frequent wave period close to the natural period of the outer buoy to achieve the optimal energy capture.  相似文献   

9.
This paper extends the theory on capture width, a commonly used performance indicator for a wave energy converter (WEC). The capture width of a linear WEC is shown to depend on two properties: the spectral power fraction (a property introduced in this paper), which depends entirely on the sea state, and the monochromatic capture width, which is determined by the geometry of the WEC and the chosen power take off (PTO) coefficients. Each of these properties is examined in detail. Capture width is shown to be a measure of how well these two properties coincide. A study of the effects of PTO control on the capture width suggests that geometry control, a form of control that has not been the focus of much academic research, despite its use in the wave energy industry, deserves more attention. The distinction between geometry control and PTO control is outlined. While capture width is a valuable design tool, its limitations must be recognised. The assumptions made in the formulation of capture width are listed, and its limitations as a tool for estimating annual power capture of a WEC are discussed.  相似文献   

10.
This paper describes a dual-stroke acting hydraulic power take-off (PTO) system employed in the wave energy converter (WEC) with an inverse pendulum. The hydraulic PTO converts slow irregular reciprocating wave motions to relatively smooth, fast rotation of an electrical generator. The design of the hydraulic PTO system and its control are critical to maximize the generated power. A time domain simulation study and the laboratory experiment of the full-scale beach test are presented. The results of the simulation and laboratory experiments including their comparison at full-scale are also presented, which have validated the rationality of the design and the reliability of some key components of the prototype of the WEC with an inverse pendulum with the dual-stroke acting hydraulic PTO system.  相似文献   

11.
When hydraulic power take off (PTO) is used to convert the mechanical energy of a wave energy converter (WEC) into a more useful form of energy, the PTO force needs to be controlled. Continuous controlled variation of the PTO force can be approximated by a set of discrete values. This can be implemented using either variable displacement pumps or several hydraulic cylinders or several high pressure accumulators with different pressure levels. This pseudo-continuous control could lead to a complex PTO with a lot of components. A simpler way for controlling this hydraulic PTO is declutching control, which consists in switching on and off alternatively the wave energy converter's PTO. This can be achieved practically using a simple by-pass valve. In this paper, the control law of the valve is determined by using the optimal command theory. It is shown that, theoretically when considering a wave activated body type of WEC, declutching control can lead to energy absorption performance at least equivalent to that of pseudo-continuous control. The method is then applied to the case of the SEAREV wave energy converter, and it is shown than declutching control can even lead to a higher energy absorption, both in regular and irregular waves.  相似文献   

12.
This paper presents the use of a modular raft Wave Energy Converter (WEC)-type attachment at the fore edge of a rectangular Very Large Floating Structure (VLFS) for extracting wave energy while reducing hydroelastic responses of the VLFS under wave action. The proposed modular attachment comprises multiple independent auxiliary pontoons (i.e. modules) that are connected to the fore edge of the VLFS with hinges and linear Power Take-Off (PTO) systems. For the hydroelastic analysis, the auxiliary pontoons and the VLFS are modelled by using the Mindlin plate theory while the linear wave theory is used for modelling the fluid motion. The analysis is performed in the frequency domain using the hybrid Finite Element-Boundary Element (FE-BE) method. Parametric studies are carried out to investigate the effects of pontoon length, PTO damping coefficient, gap between auxiliary pontoons, and incident wave angle on the power capture factor as well as reductions in the hydroelastic responses of the VLFS with the modular attachment. It is found that in oblique waves, the modular attachment comprising multiple narrow pontoons outperforms the corresponding rigid attachment that consists of a single wide pontoon with respect to the power capture factor and the reduction in the deflection of the VLFS. In addition, it is possible to have a considerable gap between pontoons without significantly compromising the effectiveness of the modular attachment.  相似文献   

13.
14.
This paper concerns the design of feedback control systems to maximize power generation of a wave energy converter (WEC) in a random sea. In the literature on WEC control, most of the proposed feedback controllers fall into three categories. Many are static; i.e., they extract power by imposing an equivalent damping or resistive load on the power take-off (PTO) devices. Others are dynamic and are designed to maximize power generation at all frequencies, which results in an anticausal feedback law. Other dynamic control design methods are causal, and are tuned to achieve the anticausal performance at only a single frequency. By contrast, this paper illustrates that the determination of the true optimal causal dynamic controller for a WEC can be found as the solution to a nonstandard linear quadratic Gaussian (LQG) optimal control problem. The theory assumes that the control system must make power generation decisions based only on present and past measurements of the generator voltages and/or velocities. It is shown that unlike optimal anticausal control, optimal causal control requires knowledge of the stationary spectral characteristics of the random sea state. Additionally, it is shown that the efficiency of the generator factors into the feedback synthesis. The theory is illustrated on a linear dynamical model for a buoy-type WEC with significant resonant modes in surge and pitch, and equipped with three spatially-distributed generators.  相似文献   

15.
浮式防波堤与振荡浮子式波浪能转换装置集成是一种较为合理的波浪能开发利用方式,基于方箱式浮式防波堤—波浪能转换集成系统和幕帘式防波堤的研究成果,提出了一种新型方箱—垂直挡浪板式浮式防波堤—波浪能转换集成系统,建立数学模型对该集成系统的水动力特性和能量输出特性进行研究。模型基于N-S方程,采用紧致插值曲线(CIP)方法结合浸没边界法(IBM)求解。运用数值模型探究在一定波浪条件下,动力输出系统(PTO)阻尼力的大小以及挡浪板对集成系统的水动力特性和能量转换特性的影响,得到如下结论:集成系统的俘获宽度比随PTO阻尼力的增大呈现先增大后减小的趋势,在阻尼力F_(PTO)=150 N时达到最大;相对于方箱型集成系统,增设0.1 m挡浪板后可使其最大俘获宽度比η_e提高33%左右;此外,集成系统的俘获宽度比随挡浪板长度增加而增大,增长趋势逐渐变缓,在挡浪板长度S_p=0.5 m时达到最大,此时俘获宽度比η_e=0.563 1。  相似文献   

16.
The dynamic response of the mooring line will be a dominant factor to consider in their use for the station keeping of a wave energy converter (WEC). Due to the relatively small size of WECs and their being moored in relatively shallow waters the effect of waves, tide and current can be of greater significance than for other floating offshore systems. Axial line stretching and high-frequency ‘top-end’ dynamics can importantly modify damping and top-end loading.If a ‘farm’ of devices is to be considered then limitations in sea space may necessitate that the devices be relatively densely packed. This will mean that the ‘footprint’ of the mooring should be constrained, to ensure that the moorings from each device do not interfere and this will have great significance for the loading experienced by the line. One must also consider how the mooring system might change the response of the WEC and so alter its ability to extract power from the waves. Unlike a typical offshore system, the design of moorings for a WEC device must consider reliability and survivability, and the need to ensure efficient energy conversion.The design and operation of a chain mooring for a WEC is considered here. Generic experimental measurements of mooring line damping were conducted in the Heriot-Watt University wave basin at a scale of 1:10. The measurements were conducted on a single mooring line for surge motions and include the study of axial stretching and high top-end dynamics. The laboratory procedures were designed to resemble tests undertaken earlier at ‘full’ scale in 24 m water depth. The measurements were also compared with numerical studies. The experimental findings for WEC devices, supports the conclusion that dynamic mooring line motion will be an important variable, needing to be considered carefully within the design.  相似文献   

17.
《Coastal Engineering》2005,52(8):709-725
Wave decay in a rubble mound breakwater has been analysed theoretically for various types of damping functions (linear, quadratic and polynomial). The applicability of these damping functions for wave decay in the landward part of the breakwater core has been investigated in large scale model tests. The properties of the rock materials that have been used in the model tests have been determined to provide a rational basis for the damping coefficients. The analysis is based on detailed measurements of wave conditions and pressure distributions inside the breakwater. The theoretical approaches have been validated and where necessary extended by empirical means. The wave decay inside the breakwater can be reasonably approximated by the commonly applied linear damping model (resulting in exponential wave height attenuation). An extended polynomial approach provides a slightly better fit to the experimental results and reflects more clearly the governing physical processes inside the structure.  相似文献   

18.
Several Wave Energy Converters (abbreviated as WECs) have intensively been studied and developed during the last decade and currently small farms of WECs are getting installed. WECs in a farm are partly absorbing, partly redistributing the incident wave power. Consequently, the power absorption of each individual WEC in a farm is affected by its neighbouring WECs. The knowledge of the wave climate around the WEC is needed to predict its performance in the farm. In this paper a technique is developed to implement a single and multiple WECs based on the overtopping principle in a time-dependent mild-slope equation model. So far, the mild-slope equations have been widely used to study wave transformations around coastal and offshore structures, such as breakwaters, piles of windmills and offshore platforms. First the limitations of the WEC implementation are discussed through a sensitivity analysis. Next the developed approach is applied to study the wave height reduction behind a single WEC and a farm. The wake behind an isolated WEC is investigated for uni- and multidirectional waves; it is observed that an increase of the directional spread leads to a faster wave redistribution behind the WEC. Further the wake in the lee of multiple WECs is calculated for two different farm lay-outs, i.e. an aligned grid and a staggered grid, by adapting the performance of each WEC to its incident wave power. The evolved technique is a fast tool to find the optimal lay-out of WECs in a farm and to study the possible influence on surrounding activities in the sea.  相似文献   

19.
A point-absorber-type Wave-Energy Converter (WEC) consisting of a floating vertical inner cylinder and an annular outer cylinder that slides along the inner one is considered. The two cylinders heave differently under wave excitation, and wave energy can be harnessed from the relative heave motion between the two cylinders using a Permanent Magnet Linear Generator (PMLG) as the Power Take-Off unit. A mooring cable is attached to the bottom of the inner cylinder. This paper aims to examine the effect of the stiffness of the mooring cable on the performance of the coaxial-cylinder WEC system. The two limiting cases of no mooring cable (freely floating inner and outer cylinders) and an infinitely stiff mooring cable (fixed inner cylinder) were also considered. To perform the analysis, hydrodynamic and interference coefficients of the two heaving cylinders were computed semi-analytically using the method of matched eigenfunction expansions. Experimentally determined viscous corrections on damping were also included in the model in order to have more realistic predictions. The performance of the system in terms of motion responses and capture width were predicted and discussed for both regular and irregular waves. The results of the analysis indicate that both the freely floating design and the design with rigidly moored inner cylinder are viable. The two limiting cases show similar optimal performances, albeit with very different optimal generator damping. However, an ill-chosen mooring-cable stiffness may cause the inner and the outer cylinders to have the same resonance frequency, eliminating the relative heave motion and leading to almost no energy extraction. This situation needs to be avoided when designing the mooring system for a coaxial-cylinder WEC.  相似文献   

20.
基于成本共享理念的波浪能发电装置(WEC)的开发与设计为降低建设成本提供了新的研究思路,应用计算流体力学方法对在透空箱式防波堤前附加垂荡浮子的集成装置进行数值模拟研究,主要研究了流体黏性和非线性PTO系统以及浮子形状对此类集成装置能量转换效率的影响。结果表明,此类集成装置可以获得较高的波能捕获宽度比(CWR),最高可达0.7,可以较好地利用反射波波能。共振区间上受黏性影响较大,相比于线性无黏理论解,CWR下降明显;实现了2种非线性PTO系统的模拟,有待于进一步的优化未获得更高的CWR值;浮子形状优化效果明显,采用圆底形浮子受黏性影响更小,可以获得更大的CWR值。此种集成模型的模拟和研究可以为新型防波堤设计和现有防波堤的改造提供思路和参考。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号