首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
研究了微波消解酸溶和过氧化钠碱熔两种测定岩石样品中锆、铌、铪、钽前处理方法,利用电感耦合等离子体质谱法进行测定。对所选用不同种类的岩石国家标准物质样品进行了条件实验,结果表明:采用过氧化钠碱熔法处理岩石样品后,锆、铌、铪、钽的测量值准确度高,且相对标准偏差(RSD,n=10)小于6%,该方法更适用于岩石样品中锆、铌、铪、钽的测定。  相似文献   

2.
The complete dissolution of representative test portions of powdered rock samples for the determination of the mass fractions of trace elements by ICP‐MS relies either on aggressive and time‐consuming acid digestions or fusion/sintering with appropriate fluxes. Here, we evaluate a microwave oven dissolution method that employs a solution of NH4HF2 and HNO3. The entire procedure occurs in a closed vessel system and takes up to 4 h. In hundreds of digestions, the precipitation of fluorides was never observed. Replicate decomposition of 100 mg of twenty‐one international reference materials (RMs) of igneous rocks, and also one of a shale presented mostly satisfactory recoveries of forty‐one trace elements. Important exceptions were Zr and Hf in G‐2 and GSP‐2 (mean recoveries of ca. 70%), although for four other felsic rock RMs, the digestion was complete. For ultramafic rock RMs, we present Cr results that indicate quantitative dissolution of Cr‐bearing phases. We discuss the findings and conclude that advances in sample preparation of geological materials for instrumental analysis would benefit from a better understanding of how specific characteristics, such as composition and crystallinity of certain minerals, may affect their reactivity.  相似文献   

3.
We present a revised alkali fusion method for the determination of trace elements in geological samples. Our procedure is based on simple acid digestion of powdered low‐dilution (flux : sample ≈ 2 : 1) glass beads where large sample dilution demanded by high total dissolved solids, a main drawback of conventional alkali fusion, could be circumvented. Three geological reference materials (G‐3 granite, GSP‐2 granodiorite and SGD‐1a gabbro) decomposed by this technique and routine tabletop acid digestion were analysed for thirty trace elements using a quadrupole ICP‐MS. Results by conventional acid digestion distinctly showed poor recoveries of Zr, Hf and rare earth elements due to incomplete dissolution of resistant minerals. On the other hand, results obtained by our method were in reasonable agreement with reference data for most analytes, indicating that refractory minerals were efficiently dissolved and volatile loss was insignificant.  相似文献   

4.
We have developed a rapid and accurate method to determine Zr, Nb, Hf and Ta (denoted as HFSE) in geological samples by inductively coupled plasma-mass spectrometry fitted with a flow injection system (FI-ICP-MS). The method involves sample decomposition by HF followed by HF dissolution of HFSE coprecipitated with insoluble M and Ca fluoride residues formed during the initial HF attack. This HF solution was directly nebulized into an ICP mass spectrometer. An external calibration curve method and an isotope dilution method (ID) were applied for the determination of Nb and Ta, and of Zr and Hf, respectively. Recovery yields of HFSE were > 96% for peridotite, basalt and andesite compositions, apart from Zr and Hf for peridotite (> 85%). No matrix effects for either signal intensities of HFSE or isotope ratios of Zr and Hf were observed in basalt, andesite and peridotite solutions down to a dilution factor of 100. Detection limits in silicate rocks were 40, 2, 1 and 0.1 ng g-1 for Zr, Nb, Hf and Ta, respectively. This technique required only 0.1 ml of sample solution, and thus is suitable for analysing small and/or precious samples such as meteorites, mantle peridotites and their mineral separates. We also present newly determined data for the Zr, Nb, Hf and Ta concentrations in USGS silicate reference materials DTS-1, PCC-1, BCR-1, BHVO-1 and AGV-1, GSJ reference materials JB-1, -2, -3, JA-1, -2 and -3, and the Smithsonian reference Allende powder.  相似文献   

5.
Complete dissolution is essential to obtain accurate analytical results using ICP-MS. In this study, decomposition techniques (i.e. acid digestions using Savillex Teflon vials, a high pressure digestion system and microwave oven, a combined lithium tetraborate fusion - HF/HNO3 acid decomposition and sodium peroxide sinter) for the total dissolution of different types of geological reference materials have been investigated. Savillex Teflon vial HF/HNO3 digestion is effective for basaltic samples. The high pressure HF/HClO4 digestion (PicoTrace TC-805 digestion system, Bovenden, Germany) allows dissolution of basalts and ironstones. Granites and magnetite-rich samples can be dissolved using a high pressure HF/H2SO4 method. Geological samples cannot be effectively attacked by microwave acid digestion. A combined lithium tetraborate fusion - HF/HNO3 acid digestion method allows complete dissolution of many different types of geological materials; however, this method precludes the determination of volatile elements due to the high fusion temperature (1000 °C). A sodium peroxide sinter method at 480 °C has the potential for the rapid determination of Y, Sc and REE in different types of geological materials. However, the lack of ultra-pure reagents precludes the use of lithium tetraborate fusion and sodium peroxide sinter methods for the measurement of geological samples with low trace element abundances.  相似文献   

6.
Data on thirty-four minor and trace elements including all rare earth elements (REE) are reported for two kimberlitic international reference materials (SARM-39, MINTEK, RSA and MY-4, IGEM, Russia) by inductively coupled plasma-mass spectrometry (ICP-MS), some of them for the first time. Four digestion techniques (open acid, closed vessel acid, microwave and lithium metaborate fusion digestion) were used for the decomposition of samples for analysis by ICP-MS. Three other reference materials (USGS BHVO-1, CRPG BR-1 and ANRT UB-N) were analysed simultaneously using the same analytical methodology to assess the precision and accuracy of the determinations. The data obtained in this study compare well with working values wherever such values are available for comparison. Though open acid digestion was found to be very rapid, effective and convenient for the determination of several trace elements in kimberlitic samples, recoveries for heavy rare earth elements (HREE) were lower than the respective recoveries obtained by the other decomposition techniques used. The precision obtained was better than ± 6% RSD in the majority of cases with comparable accuracy. Chondrite-normalised plots of each RM for all the digestion techniques were smooth. The new data reported on the two kimberlitic reference materials make these samples useful for future geochemical studies of kimberlitic rocks.  相似文献   

7.
A new digestion procedure and chemical separation technique has been developed for measurement of Lu/Hf and Hf isotope ratios that does not require high‐pressure bombs or use of HF or HClO4 acids. Samples are digested in dilute HCl or HNO3 after flux‐fusion at 110 0 °C in the presence of lithium metaborate. High field strength elements (HFSE) and rare earth elements (REE) are separated from this solution by co‐precipitation with iron hydroxide. The dissolved precipitate (in 2 mol l?1 HCl) is loaded directly onto a standard cation exchange column which separates remaining sample matrix from the heavy REE (Lu+Yb), and the middle‐light REE and HFSE (Hf). The middle‐light REE and individual HFSE are then separated (10.5, 9 and 6 mol l?1 HCl) using a miniaturized column containing TEVA spec resin which provides a REE‐, Ti‐ and Zr‐free Hf cut. This chemical separation scheme can also be readily adapted for isotopic analysis of the Sm‐Nd system and/or the other HFSE (Ti, Zr). Total procedural blanks for this technique are < 10 0 pg and < 2 pg for Hf and Lu, respectively, even when digesting large (0.5 g) samples. We present data from replicate digestions of international rock reference materials which demonstrate this technique routinely reproduces Lu/Hf ratios to < 0.2% (2s) and 176 Hf/177 Hf isotope ratios to < 30 ppm (2s). Moreover, the technique is matrix‐independent and has been successfully applied to analysis of diverse materials including basalts, meteorites, komatiites, kimberlites and carbonatites. The relative simplicity of this technique, coupled with the ease of digestion (and sample‐spike equilibration) of large difficult‐to‐dissolve samples, and the speed (2 days) with which samples can be digested and processed through the chemical separation scheme makes it an attractive new method for preparing samples for Lu‐Hf isotopic investigation.  相似文献   

8.
A simple, rapid and precise method is described for determining trace elements by laser ablation (LA)-ICP-MS analysis in bulk geological materials that have been prepared as lithium borate glasses following standard procedures for XRF analysis. This approach reliably achieves complete sample digestion and provides for complementary XRF and LA-ICP-MS analysis of a full suite of major and trace elements from a single sample preparation. Highly precise analysis is enabled by rastering an ArF excimer laser (λ= 193nm) across fused samples to deliver a constant sample yield to the mass spectrometer without inter-element fractionation effects during each analysis. Capabilities of the method are demonstrated by determination of twenty five trace elements (Sc, Ti, V, Ga, Rb, Sr, Y, Zr, Nb, Cs, Ba, REE, Hf, Ta, Pb, Th and U) in a diverse range of geological reference materials that includes peridotites, basalts, granites, metamorphic rocks and sediments. More than 90% of determinations are indistinguishable from published reference values at the 95% confidence level. Systematic bias greater than 5% is observed for only a handful of elements (Zr, Nb and U) and may be attributed in part to inaccurate calibration values used for the NIST SRM 612 glass in the case of Zr and Nb. Detection limits for several elements, most notably La, are compromised at ultra-trace levels by impurities in the lithium borate flux but can be corrected for by subtracting appropriate procedural blanks. Reliable Pb analysis has proved problematic due to variable degrees of contamination introduced during sample polishing prior to analysis and from Pt-crucibles previously used to fuse Pb-rich samples. Scope exists for extending the method to include internal standard element/isotope spiking, particularly where integrated XRF analysis is not available to characterise major and trace elements in the fused lithium borate glasses prior to LA-ICP-MS analysis.  相似文献   

9.
Abstract. An improved alkali fusion method followed by HF-HNO3-HC1O4 treatment is performed for simultaneous determination of 23 trace elements (Sr, Y, Zr, Nb, Ba, Hf, Ta, Th, U, and REE) by ICP-MS in rock reference materials: basaltic rocks (JB-2, JB-3) and granitic rocks (JG-la, JG-2, JG-3). Our improved method offers several advantages including: (1) suppression of whitish precipitates probably composed of insoluble fluorides by addition of HCIO4, (2) simple and reliable preparation procedure, (3) instrument calibration which enables straightforward simultaneous multi-elemental analysis, and (4) the very low background levels by using pure lithium tetraborate flux. We obtained the analytical results with a reproducibility of mostly <2 % (1) for the basaltic rocks and <7 % for the granitic rocks. The higher relative standard deviation (RSD) values for granitic rocks may be attributed to sample heterogeneity of coarse-grained granitic rocks. The analytical results of the granitic rocks demonstrate that Zr and Hf abundances are consistent with the compiled values and that REE concentrations agree well with recently published data, suggesting that the Li2B4O7 fusion method applied in the present study is suitable for the analysis of the granitic rocks.  相似文献   

10.
A field filtration method for the concentration and separation of suspended particulate matter (SPM) from freshwater systems and the subsequent determination of minor, trace and ultra trace elements (As, Ba, Be, Cd, Co, Cr, Cs, Cu, Ga, Hf, Mo, Nb, Ni, Pb, Rb, Sb, Sc, Sn, Sr, Ta, Th, Tl, U, V, W, Zn and Zr) is validated with respect to detection limits, precision and bias. The validation comprises the whole procedure including filtration, sample digestion and instrumental analysis. The method includes two digestion procedures (microwave acid digestion and alkali fusion) in combination with inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma quadrupole mass spectrometry (ICP-QMS). Total concentrations of these 27 trace and minor elements have been determined in suspended particulate matter (SPM) from lake and river water with low levels of suspended solids (<2 mg L−1 DW), and a wide range of element concentrations. The precision of the method including filtration, digestion and instrumental determination ranges between 8% and 18% RSD for most elements on a dry weight basis. Higher recovery after acid digestion is found for some elements, probably because of volatilization or retention losses in the fusion procedure. Other elements show higher recovery after fusion, which is explained by more efficient decomposition of refractory mineral phases relative to the non-total acid digestion. Non-detectable concentrations of some elements are reported due to small differences between blank filter levels and the amounts of elements present on the filters after sampling. The method limits of detection range between 0.7 ng and 2.65 μg, as estimated from the blank filter samples. These detection limits are 10–550 times higher compared to the corresponding instrumental limits of detection. The accuracy and bias of the overall analytical procedure was assessed from replicate analysis of certified reference materials. A critical evaluation of the instrumental capabilities of the ICP-QMS instrumentation in comparison with a double focusing sector field plasma mass spectrometry technique (ICP-SFMS) is also included. It was found that a modified microwave acid digestion procedure in combination with ICP-SFMS could replace ICP-AES determinations and fusion digestions for most of the investigated elements. Guidelines and limitations for this time- and labour- efficient procedure, offering accurate results for the majority of elements studied are discussed.  相似文献   

11.
In this paper we describe a flux‐free fusion technique for the highly precise LA‐ICP‐MS bulk analysis of geological samples. For this purpose we have developed an automated iridium‐strip heater with temperature and melt time control. To optimise the homogeneity of the fused glasses and to reduce possible depletion of volatile elements during melting, we undertook experiments with basaltic rock and glass powders using different melting temperatures (1300–1700 °C) and melting times (5‐80 s). Major and trace element microanalysis was performed using EPMA and LA‐ICP‐MS. Homogeneous glasses were obtained for temperatures ≥ 1500 °C and melting times ≥ 10 s. High loss (20‐90%) of highly volatile elements (e.g., Cs, Ge, Sn, Pb) was observed for high melting temperatures (≥ 1600 °C) and long melting times (80 s). Standard melting conditions (1600 °C, 10 s) represent a compromise, as the glasses were homogeneous with respect to major and trace elements and, at the same time, were not depleted in elements with condensation temperatures (at a pressure of 10?4 bar) higher than about 900 K (e.g., Zr, Hf, Ba, Sr, REE, U, Mo, Ni, Rb, Ga). Several international geological reference materials with SiO2 ranging between 47% m/m and 59% m/m were prepared using our standard melting conditions (1600 °C, 10 s) and subsequently analysed by LA‐ICP‐MS. These samples also include the new Brazilian basaltic reference material BRP‐1. Matrix‐matched calibration of the LA‐ICP‐MS data was performed using the basaltic reference glasses KL2‐G, ML3B‐G, BCR‐2G and BHVO‐2G. Most analytical data agreed within uncertainty at the 95% confidence level with the GeoReM preferred values published in the GeoReM database for reference materials of geological and environmental interest. To demonstrate routine bulk LA‐ICP‐MS analyses of geochemical and cosmochemical samples using the whole rock fusion technique, we also present trace element data for ocean island basalts from Lanai (Hawaii) and of Martian meteorites.  相似文献   

12.
We report an improved procedure for the determination of the platinum‐group elements (PGE) and Re, and Os isotopes from a single sample aliquot by isotope dilution (ID) using inductively coupled plasma‐mass spectrometry (ICP‐MS) and negative thermal ionisation mass spectrometry (N‐TIMS), respectively. A two‐stage column method was used to purify PGE‐Re from their sample matrix and interfering elements (e.g., Mo, Zr and Hf) after Os had been separated by CCl4 solvent extraction. The first column separation step used cation exchange resin (AG50W‐X8) to concentrate PGE‐Re and some potential interfering elements (e.g., Mo, Zr and Hf). In the second step, N‐benzoyl‐N‐phenylhydroxylamine (BPHA) extraction resin was used to separate PGE‐Re from the remaining interfering elements, which all remained strongly absorbed to the resin. The method was used to determine the PGE and rhenium, and Os isotope ratios in a range of geochemical reference materials (TDB‐1, WGB‐1, BHVO‐2 and UB‐N). The obtained results agree well with those previously published. This new method enables PGE‐Re abundances and Os isotopic ratios to be determined on the same sample digestion, and circumvents the problems created by sample heterogeneity when comparing PGE and Re‐Os isotope data.  相似文献   

13.
We present a revised method for the determination of concentrations of rare earth (REE) and other trace elements (Y, Sc, Zr, Ba, Hf, Th) in geological samples. Our analytical procedure involves sample digestion using alkaline fusion (NaOH-Na2O2) after addition of a Tm spike, co-precipitation on iron hydroxides, and measurement by sector field-inductively coupled plasma-mass spectrometry (SF-ICP-MS). The procedure was tested successfully for various rock types (i.e., basalt, ultramafic rock, sediment, soil, granite), including rocks with low trace element abundances (sub ng g−1). Results obtained for a series of nine geological reference materials (BIR-1, BCR-2, UB-N, JP-1, AC-E, MA-N, MAG-1, GSMS-2, GSS-4) are in reasonable agreement with published working values.  相似文献   

14.
微波消化在磷矿石样品制备中的应用   总被引:4,自引:2,他引:4  
曹槐  尹建国 《岩矿测试》1996,15(1):58-60
以微波HNO_3消化分解磷矿石试样,用ICP-AES进行多元素同时测定。该方法经磷矿石标准样品验证后,用于云南省九个地区磷矿中Ca、P、Fe、Al、Mg和K六种元素的分析,结果与经典酸分解方法制备样品的分析结果相符;同一样品平行测定9次,其各元素的相对标准偏差(RSD)在1.58%~4.41%。  相似文献   

15.
We present a new method for the decomposition of silicate rocks by flux‐free fusion in preparation for whole‐rock trace element determination (Sc, Rb, Sr, Y, Zr, Nb, Cs, Ba, rare earth elements and Hf) that is especially applicable to zircon‐bearing felsic rocks. The method was verified by analyses of RMs of mafic (JB‐1a, JB‐2, JGb‐1) and felsic rocks (JG‐3, JR‐3, JSd‐1, GSP‐2, G‐2). Pellets of powdered sample (up to 500 mg) without flux were weighed and placed in a clean platinum crucible. The samples were then fused in a Siliconit® tube furnace and quenched to room temperature. The optimum condition for the fusion of granitic rock was determined to be heating for 2–3 min at 1600 °C. The fused glass in the platinum crucible after heating was decomposed using HF and HClO4 in a Teflon® beaker. Decomposed and diluted sample solutions were analysed using a quadrupole inductively coupled plasma‐mass spectrometer. Replicate analyses (n = 4 or 5) of the RMs revealed that analytical uncertainties were generally < 3% for all elements except Zr and Hf (~ 6%) in JG‐3. These higher uncertainties may be attributed to sample heterogeneity. Our analytical results for the RMs agreed well with recommended concentrations and recently published concentrations, indicating complete decomposition of our rock samples during fusion.  相似文献   

16.
高岭土作为重要的铝硅酸盐,其微量元素的含量决定着高岭土产品的性能指标.高岭土的三种国家标准物质成分GBW03121、GBW03122、GBW03122a中均未含有As、Sb等10种微量元素的标准值,在高岭土的检测中只能采用近似的岩石标准物质作为监控物质,对高岭土组分的准确分析有一定影响.本文通过微波消解技术,对比了硝酸...  相似文献   

17.
报道了利用一次溶样和同一化学流程分离富集地质样品中铂族元素(Pt、Pd、Os、Ir和Ru)和Re的方法.该化学流程包括以下几个步骤:(1) Carius管溶样法分解岩石样品中富集铂族元素的矿物;(2)四氯化碳萃取法分离出Os;(3)微蒸馏法进一步纯化Os;(4)阳离子交换树脂法将铂族元素(Pt、Pd、Ir和Ru)以及R...  相似文献   

18.
高温、高压封闭压力酸溶可有效分解岩石、土壤、沉积物等地质样品,采用电感耦合等离子体质谱法(ICP-MS)进行测定,大部分元素可得到满意的回收率;但Zr、Hf、REEs、Rb、Th、U等元素用硝酸复溶困难,测定结果不准确。本文对传统的封闭压力酸溶方法进行改进,用盐酸复溶提取代替硝酸复溶提取,ICP-MS法测定岩石、土壤、沉积物等国家一级标准物质中Li、Be、Cr、Mn、Co、Ni、Cu、Zn、Ga、Rb、Sr、Mo、Cd、In、Cs、Ba、Ti、Zr、Nb、Sn、Sb、W、Hf、Ta、Tl、Pb、Bi、Th、U以及稀土元素(REEs)等46个元素。将原方法中的称样量25 mg加大至100 mg,溶样时间由12 h延长至48 h,有效地解决了取样代表性及HNO3复溶提取时Rb、Sr、REEs等元素测定结果偏低的问题。分析结果表明,除元素As和V在电感耦合等离子体质谱测定中存在Cl的干扰不能准确测定之外,其他44个元素的测定值与标准值基本一致。改进后的方法测定下限为0.01~0.85μg/g,精密度(RSD,n=10)为0.73%~13.1%,准确度小于<10%。方法准确、可靠,适用于各种不同种类地质样品的分析。  相似文献   

19.
用电感耦合等离子体质谱法(ICP-MS)测定地质样品中的稀土及难熔元素,混合酸敞开酸溶法和碱熔融法是两种主要的溶样方法。但地质样品组分复杂,元素之间存在相互共生的现象,对于特殊元素、特殊样品用传统酸溶法会造成部分元素消解不完全,使测定结果不准确;而碱熔法的操作过程繁琐,且溶液盐度高,易产生基体干扰和堵塞仪器进样系统。本文改进了传统四酸和五酸体系,采用氢氟酸-硝酸-硫酸敞开酸溶体系,用国家一级标准物质制作标准曲线测定15种稀土元素,方法准确度(ΔlgC)为0.001~0.027。同时改进了偏硼酸锂碱熔法,样品用偏硼酸锂碱熔提取,加入氢氧化钠调节溶液至碱性条件,所测元素与偏硼酸锂共沉淀后过滤分离熔剂,再用硝酸复溶测定15种稀土元素及铌钽锆铪。两种溶样方法的测定值与认定值的相对误差为1.09%~9.30%。将混合酸敞开酸溶法测定稀土元素、偏硼酸锂碱熔法测定铌钽锆铪的结果与其他实验室密闭酸溶法相比,两组数据的相对偏差为0.13%~15.32%。本实验表明,混合酸敞开酸溶法适用于测定地质样品中的稀土元素,偏硼酸锂碱熔法不仅适用于测定地质样品中的稀土元素及铌钽锆铪,也适用于测定如古老高压变质岩石及铝含量高的样品中的铌钽锆铪。  相似文献   

20.
采用丹宁棉对地质样品溶液中的铌、钽、锆、铪进行分离富集,将写信后的丹宁棉在600℃灼烧30min,灰分用发射光谱法同时测定四元素。检出限与通常的发射光谱法相比降低约2个数量级,经国家级标准物质检验,结果与标准值相符,精密度试验,各元素的RSD(n=20)为2.6%-7.9%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号