首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The natural river water certified reference material SLRS‐5 (NRC‐CNRC) was routinely analysed in this study for major and trace elements by ten French laboratories. Most of the measurements were made using ICP‐MS. Because no certified values are assigned by NRC‐CNRC for silicon and 35 trace element concentrations (rare earth elements, Ag, B, Bi, Cs, Ga, Ge, Li, Nb, P, Rb, Rh, Re, S, Sc, Sn, Th, Ti, Tl, W, Y and Zr), or for isotopic ratios, we provide a compilation of the concentrations and related uncertainties obtained by the participating laboratories. Strontium isotopic ratios are also given.  相似文献   

2.
We report on an improved method for determining trace element abundances in seawater and other natural waters. The analytical procedure involves co‐precipitation on iron hydroxides after addition of a Tm spike, and measurement by inductively coupled plasma‐sector field mass spectrometry (ICP‐SFMS). The validity of the method was assessed through a series of co‐precipitation experiments, using ultra‐diluted solutions of a certified rock reference material (BIR‐1). Results obtained for four natural water reference materials (NASS‐5, CASS‐4, SLEW‐3, SLRS‐4) are in agreement with published working values for rare earth elements, yttrium, vanadium and, when available, for hafnium, zirconium, thorium and scandium. A set of proposed values with uncertainties typically better than 8% RSD is proposed for Hf, Zr and Th.  相似文献   

3.
The natural river water certified reference material SLRS-4 (NRC-CNRC, National Research Council-Conseil National de Recherches Canada) has been routinely analysed for major and trace elements by six French laboratories. Most measurements were made using inductively coupled plasma-mass spectrometry. For silicon and thirty one trace elements (rare earth elements, Ag, B, Br, Cs, Ga, Ge, Li, P, Pd, Rb, Se, Th, Ti, Tl, W, Y and Zr), no certified values are assigned by NRC-CNRC. We propose some compilation values and related uncertainties according to the results obtained by the different laboratories.  相似文献   

4.
The natural river water reference material SLRS‐6 (NRC‐CNRC) is the newest batch of a quality control material routinely used in many international environmental laboratories. This work presents a nine‐laboratory compilation of measurements of major and trace element concentrations and their related uncertainties, unavailable in the NRC‐CNRC certificate (B, Cs, Li, Ga, Ge, Hf, Nb, P, Rb, Rh, Re, S, Sc, Se, Si, Sn, Th, Ti, Tl, W, Y, Y, Zr and REEs). Measurements were mostly made using inductively coupled plasma‐mass spectrometry. The results are compared with equivalent data for the last batch of the material, SLRS‐5, measured simultaneously with SLRS‐6 in this study. In general, very low concentrations, close to the quantification limits, were found in the new batch. The Sr isotopic ratio is also reported.  相似文献   

5.
The preparation and characterisation of three nickel ores and two nickel concentrate certified reference materials are described in this paper. The samples of nickel ore and nickel concentrate were collected from the Hongqiling nickel deposit in Jilin province. The raw materials were crushed and passed through a 2.0‐mm sieve. The rough samples were then ground for 48 hr in a high‐alumina ball mill to a final size of < 0.074 mm. Homogeneity of the samples was tested by X‐ray fluorescence spectrometry (WD‐XRF) and inductively coupled plasma‐atomic emission spectrometry (ICP‐AES). The relative standard deviations (RSD) of results on mass fraction measurements by WD‐XRF were < 1.0% m/m for eighteen components. F‐tests showed that all five samples were homogeneous. Nineteen laboratories contributed with measurement results (2127 in total) for the certification of mass fractions for twenty‐three elements and compounds. Twenty‐three components in the nickel ores and twenty components in the nickel concentrates were characterised as certified values, while the Ni mass fractions ranges from 0.1 to 9.02% m/m in these certified reference materials. These five samples were approved as national certified reference materials by the National Organisation of Reference Materials of China in 2012.  相似文献   

6.
Isotope dilution (ID) mass spectrometry is a primary method of analysis suited for the accurate and precise measurement of several trace elements in geological matrices. Here we present mass fractions and respective uncertainties for Cr, Cu, Ni, Sn, Sr and Zn in 10 silicate rock reference materials (BCR‐2, BRP‐1, BIR‐1, OU‐6, GSP‐2, GSR‐1, AGV‐1, RGM‐1, RGM‐2 and G‐3) obtained by the double ID technique and measuring the isotope ratios with an inductively coupled plasma‐mass spectrometer equipped with collision cell. Test portions of the samples were dissolved by validated procedures, and no further matrix separation was applied. Addition of spikes was designed to achieve isotope ratios close to unity to minimise error magnification factors, according to the ID theory. Radiogenic ingrowth of 87Sr from the decay of 87Rb was considered in the calculation of Sr mass fractions. The mean values of our results mostly agree with reference values, considering both uncertainties at the 95% confidence level, and also with ID data published for AGV‐1. Considering all results, the means of the combined uncertainties were < 1% for Sr, approximately 2% for Sn and Cu, 4% for Cr and Ni and almost 6% for Zn.  相似文献   

7.
Two Co‐rich seamount crust reference materials, MCPt‐1 and MCPt‐2, were prepared using ultra‐fine particle size milling technique and characterised for the platinum‐group elements (PGEs). The raw material for these two reference materials was collected separately from the Magellan seamounts of the western Pacific Ocean and the seamounts of the central Pacific Ocean by Russian and Chinese scientists. First, they were ground by ball mill to a ?200 mesh powder, then further processed by ultra‐fine jet mill and well‐mixed. The particle size distributions of the samples were tested by a laser particle analyser; the average particle size was 1.8 and 1.5 μm (equal to about 2000 mesh) respectively. The homogeneity of six major and minor elements in these two materials was tested at the milligram level of sampling mass by high‐precision wavelength dispersive X‐ray fluorescence (XRF) spectrometry and at the microgram level of sampling mass by electron probe microanalyser. The homogeneity of more than forty trace elements, including Pt, was tested at the microgram level of sampling mass by LA‐ICP‐MS. Except for Rh, all PGEs were determined by isotope dilution‐ICP‐MS. Platinum in MCPt‐1 and MCPt‐2 was characterised as certified values, whereas the other five PGEs in MCPt‐1 and MCPt‐2 were reported as reference values. In addition, the information values of sixty‐two major, minor and trace elements were obtained by XRF, ICP‐AES and ICP‐MS. The minimum sampling mass for the determination of PGEs was 1 g, while the minimum sampling mass for the determination of the other elements was 2–5 mg.  相似文献   

8.
A method for the determination of total sulfur in geological materials by inductively coupled plasma‐optical emission spectrometry (ICP‐OES) is described. We show that good results were obtained using this method even for sample types with very low (< 20 μg g?1) sulfur concentration (e.g., peridotite). Sulfur was determined in fifteen geological reference materials with different sulfur contents. For reference materials with certified sulfur contents, the ICP‐OES method gave results in excellent agreement with certified values, and uncertainties better than 4% RSD. ICP‐OES results for sulfur in other reference materials yielded RSDs better than 10%, where S concentrations were > 100 μg g?1 (except for diabase W‐2a, 16% RSD). Reference materials with lower sulfur contents (< 40 μg g?1) showed much higher RSDs (17–18%). Except for RMs with certified values for sulfur, most data obtained by the combustion infrared detection method generally showed higher concentrations than those measured by ICP‐OES and a better RSD (≤ 8% for all materials except DTS‐2b).  相似文献   

9.
Development of new techniques, enabling simultaneous determination of large numbers of elements in environmental samples, can force analysts to use certified reference materials that do not contain all the elements of interest. In this paper, the mass fractions of forty‐six major and trace elements, including rare earth elements (REE), are presented in one soil (NCS DC 77302 also known as GBW 07410) and five sediment (Metranal‐1, IAEA 405, MESS‐3, NCS DC 73309 also known as GBW 07311 and NCS DC 75301 also known as GBW 07314) certified reference materials determined by high resolution inductively coupled plasma‐mass spectrometry. The selected certified materials represent a spectrum of geological matrices often analysed in environmental studies. Measured elements include certified elements, elements listed with information values as well as new elements absent from certificates, including REEs and some other elements. REE + Y mass fractions in the river sediment reference material Metranal‐1 are reported for the first time. The results obtained are in agreement with available certified or information values.  相似文献   

10.
We report an improved procedure for the determination of the platinum‐group elements (PGE) and Re, and Os isotopes from a single sample aliquot by isotope dilution (ID) using inductively coupled plasma‐mass spectrometry (ICP‐MS) and negative thermal ionisation mass spectrometry (N‐TIMS), respectively. A two‐stage column method was used to purify PGE‐Re from their sample matrix and interfering elements (e.g., Mo, Zr and Hf) after Os had been separated by CCl4 solvent extraction. The first column separation step used cation exchange resin (AG50W‐X8) to concentrate PGE‐Re and some potential interfering elements (e.g., Mo, Zr and Hf). In the second step, N‐benzoyl‐N‐phenylhydroxylamine (BPHA) extraction resin was used to separate PGE‐Re from the remaining interfering elements, which all remained strongly absorbed to the resin. The method was used to determine the PGE and rhenium, and Os isotope ratios in a range of geochemical reference materials (TDB‐1, WGB‐1, BHVO‐2 and UB‐N). The obtained results agree well with those previously published. This new method enables PGE‐Re abundances and Os isotopic ratios to be determined on the same sample digestion, and circumvents the problems created by sample heterogeneity when comparing PGE and Re‐Os isotope data.  相似文献   

11.
Here we report uranium and thorium isotopic ratios and elemental concentrations measured in solid reference materials from the USGS (BHVO‐2G, BCR‐2G, NKT‐1G), as well as those from the MPI‐DING series (T1‐G, ATHO‐G). Specifically created for microanalysis, these naturally‐sourced glasses were fused from rock powders. They cover a range of compositions, elemental concentrations and expected isotopic ratios. The U‐Th isotopic ratios of two powdered source materials (BCR‐2, BHVO‐2) were also characterised. These new measurements via multi‐collector thermal ionisation mass spectrometry and multi‐collector inductively coupled plasma‐mass spectrometry can now be used to assess the relative performance of techniques and facilitate comparison of U‐Th data amongst laboratories in the geoscience community for in situ and bulk analyses.  相似文献   

12.
A procedure for determining a wide range of chalcophile and siderophile elements in typical crustal rocks using standard addition and ICP‐SFMS (inductively coupled plasma sector field mass spectrometry) is presented. New results for Ga, Ge, Mo, Ag, Cd, In, Sn, Sb, W, Tl and Bi abundances in USGS whole‐rock reference materials AGV‐2, BHVO‐1, BIR‐1, G‐2, GSP‐1 and W‐2 are reported using this analytical procedure. Intermediate precision of means based on multiple dissolved aliquots of each USGS reference material was 10% RSD or better for Ga, Ge, In and Sn in all, and similarly good for Ag, Cd, Sb, Tl and Bi in most reference materials. Poorer intermediate precision of Mo and W measurements in several reference materials is probably due to higher analytical blanks on these elements and powder heterogeneity due to a sulfide‐related nugget effect in the specific case of Mo in GSP‐1. Results for all elements fell within the range of available published data with the exception of Ag, which yielded systematically higher concentrations than found in the literature for five of the six reference materials, likely reflecting interference from unresolved polyatomic species.  相似文献   

13.
To test whether the silicate reference glasses BAM‐S005‐A and BAM‐S005‐B from BAM (The Federal Institute for Materials Research and Testing, Germany) are suitable materials for microanalysis, we investigated the homogeneity of these reference glasses using the microanalytical techniques EPMA, LA‐ICP‐MS and SIMS. Our study indicated that all major and most trace elements are homogeneously distributed at micrometre sampling scale in both types of glass. However, some trace elements (e.g., Cs, Cl, Cr, Mo and Ni) seem to be inhomogeneously distributed. We also determined the composition of BAM‐S005‐A and BAM‐S005‐B. The EPMA data of major elements confirmed the information values specified by the certificate. With the exception of Sr, Ba, Ce and Pb, our trace element data by LA‐ICP‐MS were also in agreement with the certified values within the stated uncertainty limits. The reasons for the discrepancy in these four elements are still unclear. In addition, we report new data for twenty‐two further trace elements, for which the concentrations were not certified. Based on our investigation, we suggest that both of these materials are suitable for many microanalytical applications.  相似文献   

14.
With implications for the origin of ore deposits, redox state of the atmosphere, and effects of volcanic outgassing, understanding the sulfur cycle is vital to our investigation of Earth processes. However, the paucity of sulfur concentration measurements in silicate rocks and the lack of well‐calibrated reference materials with concentrations relevant to the rocks of interest have hindered such investigations. To aid in this endeavour, this study details a new method to determine sulfur concentration via high mass resolution solution inductively coupled plasma‐mass spectrometry (ICP‐MS). The method is based on an aqua regia leach, involving relatively rapid sample preparation and analysis, and uses small test portion masses (< 50 mg). We utilised two independently prepared standard solutions to calibrate the analyses, resulting in 4% accuracy, and applied the method to eight geochemical reference materials. Measurements were reproducible to within ~ 10%. Sulfur concentrations and isotopes of six reference materials were measured additionally by elemental analyser‐combustion‐isotope ratio mass spectrometry to independently evaluate the accuracy of the ICP‐MS method. Reference materials that yielded reproducible measurements identical to published values from other laboratories (JGb‐1, JGb‐2 and MAG‐1) are considered useful materials for the measurement of sulfur. Reference materials that varied between studies but were reproducible for a given test portion perhaps suffer from sample heterogeneity and are not recommended as sulfur reference materials.  相似文献   

15.
Four silicate glasses were prepared by the fusion of about 1 kg powder each of a basalt, syenite, soil and andesite to provide reference materials of natural composition for microanalytical work. These glasses are referred to as ‘Chinese Geological Standard Glasses’ (CGSG) ‐1, ‐2, ‐4 and ‐5. Micro and bulk analyses indicated that the glasses are well homogenised with respect to major and trace elements. Some siderophile/chalcophile elements (e.g., Sn, Pt, Pb) may be heterogeneously distributed in CGSG‐5. This paper provides the first analytical data for the CGSG reference glasses using a variety of analytical techniques (wet chemistry, XRF, EPMA, ICP‐AES, ICP‐MS, LA‐ICP‐MS) performed in nine laboratories. Most data agree within uncertainty limits of the analytical techniques used. Discrepancies in the data for some siderophile/chalcophile elements exist, mainly because of possible heterogeneities of these elements in the glasses and/or analytical problems. From the analytical data, preliminary reference and information values for fifty‐five elements were calculated. The analytical uncertainties [2 relative standard error (RSE)] were estimated to be between about 1% and 20%.  相似文献   

16.
We present a revised alkali fusion method for the determination of trace elements in geological samples. Our procedure is based on simple acid digestion of powdered low‐dilution (flux : sample ≈ 2 : 1) glass beads where large sample dilution demanded by high total dissolved solids, a main drawback of conventional alkali fusion, could be circumvented. Three geological reference materials (G‐3 granite, GSP‐2 granodiorite and SGD‐1a gabbro) decomposed by this technique and routine tabletop acid digestion were analysed for thirty trace elements using a quadrupole ICP‐MS. Results by conventional acid digestion distinctly showed poor recoveries of Zr, Hf and rare earth elements due to incomplete dissolution of resistant minerals. On the other hand, results obtained by our method were in reasonable agreement with reference data for most analytes, indicating that refractory minerals were efficiently dissolved and volatile loss was insignificant.  相似文献   

17.
A simple, rapid method for the determination of Re and Os concentrations and isotope compositions using isotope dilution multi‐collector inductively coupled plasma‐mass spectrometry (ID‐MC‐ICP‐MS) combined with Carius tube digestion and sparging introduction of Os was developed. For Os measurement, four channeltron ion counters to detect different Os isotopes were used simultaneously, which led to a drastic reduction in the measurement time. Rhenium isotopes were measured by means of eight Faraday cups with solution nebulisation and an ultrasonic membrane desolvator. The representative 188Os count rate of an Os standard solution containing 50 pg of total Os was approximately 110000–120000 cps at the onset of measurement; the Re intensity of our in‐house 10 pg g?1 standard solution reached 1820 V/μg g?1 with a sample uptake rate of 95–99 μl min?1. These values indicate that the sensitivity of the method was sufficient even for samples with low Re and Os concentrations, such as chert. As the temporal variations of the amplification efficiency of the ion counters differed from one another, we adopted a sample‐calibrator bracketing method to correct the measured Re and Os isotope ratios. The Re and Os concentrations via the isotope dilution method and the 187Os/188Os ratios of two sedimentary rock reference materials (JMS‐2 and JCh‐1) on the basis of the isotope ratios determined by the MC‐ICP‐MS and by negative thermal ionisation mass spectrometry (N‐TIMS) were comparable within their ranges. Based on Os isotope measurement of the IAG reference material [Durham Romil Os (DROsS)], the average difference from the recommended value and precision of Os isotope measurements by the sparging method in combination with multi‐ion‐counters were 0.72% and 0.76% [1RSD (%), n = 29], respectively. The precisions in the 187Os/188Os ratios [1RSD (%)] of JMS‐2, JCh‐1 and DROsS were 0.35–0.71, 1.56–3.31 and 0.99–1.28%, respectively, which depended on their Os ion intensities. No systematic difference was observed between the Re and Os geochemical compositions of JCh‐1 and JMS‐2 obtained by means of digestion with inverse aqua regia and CrO3‐H2SO4 solutions, suggesting that either acid solution can be used for the sparging method of sedimentary rock samples. As CrO3‐H2SO4 solution is believed to liberate predominantly the hydrogenous Re and Os fraction from organic‐rich sediment, the sparging method combined with CrO3‐H2SO4 digestion and multi‐ion‐counters in the mass spectrometry is expected to be a powerful tool for reconstructing the secular change in marine Os isotope compositions with high sample throughput.  相似文献   

18.
We report homogeneity tests on large natural apatite crystals to evaluate their potential as U reference materials for apatite fission‐track (AFT) thermochronology by laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS). The homogeneity tests include the measurements of major element concentrations by electron probe microanalysis (EPMA), whereas for U concentration, isotope dilution (ID) ICP‐MS and laser ablation (LA) ICP‐MS were employed. Two apatite crystals are potential reference materials for LA‐ICP‐MS analysis: a 1 cm3 fraction of a Durango crystal (7.5 μg g?1 U) and a 1 cm3 Mud Tank crystal (6.9 μg g?1 U). The relative standard deviation (1 RSD) of the U concentration determined by ID‐ICP‐MS of both apatite crystals was ≤ 1.5%, whereas 1 RSD for the LA‐ICP‐MS results was better than 4%, providing sufficient homogeneity for fission‐track dating. The results on the U homogeneity for two different apatite samples are an important step towards establishing in situ dating routines for AFT analysis by LA‐ICP‐MS.  相似文献   

19.
The aim of this study was to improve the quality of laser ablation inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) determination of phosphorus in crystalline quartz. Over the last decade, the Geological Survey of Norway has routinely performed trace element determinations on quartz from both operating and potential quartz deposits by LA‐ICP‐MS. The determined phosphorus concentrations were, with but few exceptions, consistently within the range of 10 to 30 μg g?1, results that seemed to be both too high and too consistent. The multi‐material calibration curve obtained from a suite of reference materials (NIST SRM 610, 612, 614, 1830, BAM No. 1 amorphous SiO2 glass) did not define a precise regression line. Published phosphorus concentrations for the reference materials are poorly constrained and the observed dispersions along the multi‐material calibration curve suggest that some of the reference values may be inaccurate. Furthermore, the calibration curve did not pass through the origin of the [(cps 31P/cps 30Si) · cone. Si] vs. P concentration diagram; thus, in addition to the uncertainties of the literature values of phosphorus, it is difficult to define the calibration curve. Three reference materials (NIST SRM 614, 1830, synthetic quartz KORTH) were sent for phosphorus accelerator implantation, providing an independent and accurate (± 3%) approach for determining phosphorus concentrations in crystalline quartz. The intrinsic phosphorus concentrations of the three implanted samples plus those for NIST SRM 610 and 612 were determined by secondary ion mass spectrometry (SIMS), yielding new phosphorus values for NIST SRM 610, 612, 614 and 1830. Using these new values resulted in a better defined LA‐ICP‐MS calibration curve. However, the source of the ICP‐MS related background could not be defined, such that it must still be empirically corrected for.  相似文献   

20.
We report a measurement procedure to determine simultaneously the major cation concentrations (Na, Ca, K and Mg) of seawater‐derived solutions by inductively coupled plasma‐atomic emission spectrometry. The best results were obtained when the IAPSO (‘standard’) seawater reference material was diluted by thirty times with Milli‐Q® water. We obtained an average reference value rK (the ratio of the mass fraction of potassium to that of chlorine, i.e., (g kg?1)/(g kg?1)) for IAPSO seawater of 0.0205 ± 0.0006 (2.9% RSD), not significantly different from 0.0206 ± 0.0005 (2.4% RSD) for seawater composition reported in the literature. The measured Na, Ca and Mg concentrations correspond to rNa, rCa and rMg values of 0.5406 ± 0.0026 (0.5% RSD), 0.02192 ± 0.00048 (2.2% RSD) and 0.06830 ± 0.00047 (0.7% RSD), respectively, in line with previous values measured by wet‐chemistry and atomic absorption spectrophotometry or wet‐chemical titration. Our measurement procedure was used successfully on synthetic seawater solutions and high‐temperature hydrothermal fluids.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号